Technical Manual Ex i Power supply ENT-DC-30 ENT-DC-30, TDOCT-4038_ENG, 2015-01 Pepperl+Fuchs GmbH Mannheim Table of Content 1 Important Information ....................................................................................................................................... 1 1.1 General instructions .................................................................................................................................. 1 1.2 Safety instructions ..................................................................................................................................... 2 1.3 Symbols used in this manual .................................................................................................................... 3 2 Initial Operation ................................................................................................................................................ 4 3 ENT-DC Power Supply ..................................................................................................................................... 5 3.1 Operation ................................................................................................................................................... 5 3.2 Specifications ............................................................................................................................................ 6 3.3 Pin Assignment ......................................................................................................................................... 8 3.4 Wiring ......................................................................................................................................................11 3.4.1 Block Diagram ..................................................................................................................................11 3.4.2 Jumpers main circuit board ..............................................................................................................12 3.4.3 Jumpers additional circuit board ......................................................................................................14 3.4.4 RS 485 bus termination ...................................................................................................................15 3.4.5 Fuses ...............................................................................................................................................16 3.4.6 S-ENT/PC-25 Connecting Cable ENT-DC-2.0 to PC (25 pin D-Sub)..............................................16 3.4.7 S-ENT/PC-9 Connecting Cable ENT-DC-30 to PC (9 pin D-Sub) ...................................................17 3.4.8 S-ENT/MOUSE-9 Connecting Cable for Mouse ENT-DC-30 to PC (9 pin D-Sub) .........................17 3.4.9 DATL-A 4-10 Terminal Connection (1 feed circuit) ..........................................................................18 3.4.10 DATL-A 7-10 Terminal Connection (2 feed circuits) ........................................................................18 3.4.11 DATL-A 8-10 Terminal Connection (3 feed circuits) ........................................................................19 3.4.12 DATL-A 4-3 Connecting cable ENT-DC to EXOM-DRAGON .........................................................19 3.4.13 Potential Equalization / Grounding ..................................................................................................20 3.5 Housing ...................................................................................................................................................21 3.6 Instructions for Installation ......................................................................................................................23 3.7 Rating plates ...........................................................................................................................................24 4 Applied harmonized standards of the applicable directives ...........................................................................24 5 Order designations .........................................................................................................................................25 5.1 Exi Power supply ENT-DC ......................................................................................................................25 5.2 Connectors ..............................................................................................................................................26 6 Index ...............................................................................................................................................................27 7 Appendix EEx Certification .............................................................................................................................28 1 Important Information 1.1 General instructions Copyright 2014 by Pepperl+Fuchs GmbH All rights reserved The publisher reserves the right to alter the information and data contained in this manual without prior notice. Unless otherwise indicated, the company names as well as other names and data used in the examples are purely fictitious. The publisher may have registered patents or pending patent applications for subject matter covered in the manual. This manual does not give you license to these patents. Limited warranty: No warranty is provided for the accuracy of the information contained in this manual. As mistakes cannot be entirely avoided despite taking the greatest of care, we would be grateful to receive information about any errors you may discover. The publisher disclaims all legal responsibility or liability for errors as well as for subsequent damages and claims. Publisher: Pepperl-Fuchs GmbH Lilienthalstr. 200 68307 Mannheim Deutschland www.pepperl-fuchs.com Tel. 0621-776-0 Fax 0621-776-1000 E-Mail: [email protected] TDOCT-4038_ENG / 2015-01 1 1.2 Safety instructions These devices are only allowed to be installed and operated by trained and qualified personnel who have received suitable instruction in their use. These devices represent state-of-art technology. They are only allowed to be connected to systems that have been approved by Pepperl+Fuchs GmbH. Never open the devices yourself. They are only allowed to be opened by authorized Pepperl+Fuchs GmbH personnel. Pepperl+Fuchs GmbH is not liable for any resulting damages. The devices are not allowed to be modified or otherwise altered in any way. Pepperl+Fuchs GmbH is not liable for any resulting damages. Please study the “Technical Manual ” carefully prior to starting up the devices. The most recent version of the “Technical Manual” is always valid. It is available on the Support page of our web site (Internet address: http://www.pepperl-fuchs.com). The operating voltage of the devices must not exceed the limits indicated in the "Technical Manual" under Technical data. In the event of failure to comply, Pepperl+Fuchs GmbH is not liable for any resulting damages. The relevant specifications for hazardous areas (e.g. EN 50178, EN 60079, EN 50014 - 50039) and accident prevention regulations (e.g. UVV) must be observed. Only connect circuits to the device when the voltage of these circuits does not exceed the values of a safety extra-low voltage (SELV) or a protective extra-low voltage (PELV). The device must be installed and operated only in surrounding enclosures that comply with the requirements for surrounding enclosures according to IEC/EN 60079-0, are rated with the degree of protection IP54 according to IEC/EN 60529 Alternatively, it is permitted to install and operate the device in a monitored environment that ensures a pollution degree 2 according to IEC/EN 60664-1. The installation instructions in accordance with IEC/EN 60079-14 must be observed. Close all unused connections with the corresponding covers to ensure the degree of protection The technical data specified for the hazardous area corresponds to the certified values for the European EEx approval. The user is responsible for ensuring that the devices are suitable for their intended application and for the prevailing ambient conditions. No warranty can be given by Pepperl+Fuchs GmbH in this connection. Data subject to change without notice TDOCT-4038_ENG / 2015-01 2 1.3 Symbols used in this manual Warning: The indicated specifications may not be modified. Non-compliance may result in dangerous situations and damages. Caution: Careful installation: do not replace electrical fuses with fuses from different manufacturers. Noncompliance may result in dangerous situations and damages. Danger: The product may possibly be negatively impacted or damaged by foreign influences. Non-hazardous area: Assembly and installation only in non-hazardous areas. Power supply cables for the hazardous areas zone 1 and zone 2 only with cable type DATL-A. Danger: Hazardous area ( Zone 1+2 ) All safety regulations as well as compliance certificates for hazardous areas must be observed. In addition, all regulations (VDE) published by the respective authorities for the application of the devices in hazardous areas (zone 1 and 2) must be complied with at all times. Additional Info: Information and notices that must be observed additionally. Pressure load: Significant mechanical pressure or impact loads may result in damages. TDOCT-4038_ENG / 2015-01 3 2 Initial Operation This description for initial operation refers to those issues that must be considered with respect to the power supply ENT-DC. Information with respect to operation of the peripherals connected to the ENT-DC power supply can be found in the appropriate manual. For operation proceed as follows: Switch off system or machine. Make sure that the assembly area is non-hazardous during the initial operation in case voltages are wired or devices will be opened that are not intrinsically safe. Connect Exi power supply ENT-DC. Refer to the chapter “Wiring” for the appropriate connections. Connect protective ground wire to the power supply ENT-DC. Warning The protective ground wire runs along the housing. The housing itself must be grounded. The wire for connecting to ground must have a cross section of at least 2.5 mm² and should be as short as possible. Connect power supply. Verify all functions. Switch on system or machine. Verify functions of the entire system or machine. Warning In case the ENT-DC has not been connected correctly or its configuration is incorrect, malfunctioning of your system/machine is possible. Warning The power supply ENT-DC is exclusively designed to be integrated into a different machine. Operation may not be initiated until conformity of the final product with regulation 89/336/EC and 89/392/EC has been established and the unit has been approved by a specialist according to EN 60079 and EN 50014 respectively. TDOCT-4038_ENG / 2015-01 4 3 ENT-DC Power Supply The Exi power supply ENT-DC can be used in safe areas as a power supply for components in zone 1 and zone 2. The ENT-DC provides up to 3 feed circuits and one 20 mA CL-interface. The ENT-DC can used to feed all hazardous components which meet the interface specifications of the ENT-DC. The most important data in brief: Approval Classification in accordance [EEx ib] IIC II (2) G [EEx ib] IIC with ATEX 95 RL94/9 EG: DMT 03 ATEX E 011 X Housing Material Protection type Full, top hat rail, and 19" flush type housing aluminum IP 20 Number of feed circuits Exi voltage Uamax Exi current Ikmax Exi power Pamax 1 - 3 feed circuits 7 V .. 9 V (according to configuration) 220 mA ..350 mA (according to configuration) 1.1 W .. 1.4 W (according to configuration) Connections connectors / terminal screws 3.1 Operation To warrant sufficient ventilation, the ENT-DC must be set up as described under “Assembly” in chapter 3.6. The slots for ventilation on the unit may not be covered so that heat dissipation is warranted. TDOCT-4038_ENG / 2015-01 5 3.2 Specifications Approval: Protection type Approval Protection category: [EEx ib] IIC DMT 03 ATEX E 011 X IP 20 Housing: Material Dimensions Weight Aluminum refer to chapter “Housing” app. 1.0 kg Environmental conditions during operation: Temperature range 0 °C - + 50 °C Humidity max. 85 % non-condensating (48 h stress test) Warning The ENT-DC may only be set up and operated in a non-hazardous area. Environmental conditions storage: Temperature range X1 data interface: Data Baudrate Connector Voltage Un X2 interface power supply: Voltage Un Drawing of current -20 °C - +70 °C 20 mA CL active/passive, zero potential RS232 19.200 Baud (38.000 Baud on request) 9-pin D-Sub integrated jack, pin contacts ≤ |±15| V DC 24 V DC ±10% 1 feed circuit: app. 380 mA continuous current 2 feed circuits: appear. 550 mA continuous current 3 feed circuits: appear. 720 mA continuous current Fuse SI 1 is safety relevant. Always use the correct fuse type. 2A slow blowing (type H 1500 A) Connector 2 x 2-pin integrated jack / pin contacts, for CONNECTOR-K02-381-O TDOCT-4038_ENG / 2015-01 6 X3 Exi interface: Data Voltage supply Connector 20 mA CL active/active switched to plus Version Ua [V] Ia [mA] Pa [W] ...-1..-... 8 280 1.2 ...-2..-... 8.5 280 1.2 ...-3..-... 9 280 1.2 ...-4..-... 9 290 1.3 ...-5..-... 9 300 1.4 ...-6..-... 8,5 240 1,2 2 x 4-pin integrated jack / pin contacts, for CONNECTOR-K04-508-S Note Additional output according to the approval described in the appendix can be provided upon request. X4, X5 Exi interface (only for 19" versions -19K, -19E): Signals according to X3 Exi-interface Connector 96-pin spring contact strip DIN 41612 (not all springs equipped) TDOCT-4038_ENG / 2015-01 7 3.3 Pin Assignment For the top hat rail and full housing version of the ENT-DC-2 all connections are made in the front. For the 19"version connections can be made in the front and in the rear. All connections can be reached from the front and the back. The connections X2, X3 and X4 are carried out as terminal screw-/plug-in terminals. The connection X1 constitutes a D-Sub jack. If the power supply operates with one feed circuit the connection X3 has four contacts. If 2 or 3 feed circuits are in use the connection X3 has 8 contacts. Front elevation: 1 feed circuit: ENT-DC X3 .1 .2 2 or 3 feed circuits: ENT-DC X3 .1 .2 LED Us1 .3 .4 LED Us2 ..6 6 .7 LED Us1 .3 .4 X1 .5 LED Us3 .8 X1 X4 LED Tx LED Rx TTY RS232 X2 .1 .3 .1 .2 J5 LED Tx .2 .4 LED Rx X2 .1 .3 .2 .4 .3 J5 RS485 TTY RS232 Interface X1 Data interface for safe area (PC) 9-pin D-Sub jack with pins X1.1 X1.2 X1.3 X1.4 X1.5 X1.6 X1.7 X1.8 X1.9 TxTx+ Rx+ Rx+12V TxD RxD nc GND (20 mA CL interface) (20 mA CL interface) (20 mA CL interface) (20 mA CL interface) (max. 50 mA) (RS232 interface) (RS232 interface) X2.1 X2.2 X2.3 X2.4 PA + 24V DC PA GND (RS232 interface) Interface X2 Supply interface (24 VDC) 4-pin terminal block 0.5 mm² - 2.5 mm² TDOCT-4038_ENG / 2015-01 8 Interface X3 Data- / supply interface hazardous area 2 x 4-pin terminal screw-/plug-in terminal X3.1 X3.2 X3.3 X3.4 X3.5 X3.6 X3.7 X3.8 Rx Tx Us1 GND Us2 GND GND Us3 X4.1 X4.2 X4.3 GND RS485 A RS485 B (only assigned if 2 feed circuits) (only assigned if 2 feed circuits) (only assigned if 2 feed circuits) (only assigned if 2 feed circuits) Interface X4 on front Optional data interface RS 485 to safe area 3-pin termianl screw-/plug-in terminal TDOCT-4038_ENG / 2015-01 9 Rear elevation: 19E with 1 feed circuit: 19K with 1 or 2 feed circuits: X4 .d .b .z 19K with 3 feed circuits: X4 .d .b .z X4 .d .b .z .2 .4 .6 .2 .4 .6 .28 .30 .32 .28 .30 .32 .30 .28 .2 .4 .6 .28 .30 .32 X5 .z .b .d Interface X4 DIN jack Combi-interface 1. and 2. feed circuit X4.d.2 Us2 (Exi) X4.d.6 Us1 (Exi) X4.b.4 GND (Exi) X4.b.6 Tx20 (Exi) X4.z.2 GND (Exi) X4.z.4 GND (Exi) X4.z.6 Rx20 (Exi) X4.d.28 RxX4.d.30 Rx+ X4.d.32 Vdd X4.b.28 TxD X4.b.30 Tx+ X4.b.32 +24 V X4.z.28 RxD X4.z.30 TxX4.z.32 GND X5.z.30 GND (Exi) X5.z.28 GND (Exi) X5.b.30 GND (Exi) X5.b.28 Us3 (Exi) X5.d.30 GND (Exi) X5.d.28 Us3 (Exi) F-strip (96 pin, not all contacts equipped) Interface X5 Combi interface 3. feed circuit F-strip (96 pin, not all contacts equipped) Note For the 19" installation and 3 feed circuits a second F-strip is located in the rear of the housing. The second F-strip is turned for installation purposes. TDOCT-4038_ENG / 2015-01 10 3.4 Wiring All connections for the ENT-DC are made in the front. All clamps are also directed to the 19” header for the 19" flush type version. Hence connections can be made in the rear or combined in front and rear. Note If connections are made in the front and rear the same signals should not be assigned in the front and rear at the same time. Proper operation of the ENT-DC may be endangered in this case. (Issues with respect to safety are not impacted). 3.4.1 Block Diagram X4.d.28 X 1.4 22R Rx - HCPL 4200 S1* / J5 XOR J1 1 X4.d.30 X 1.3 J4 / J4'* GND 1 1 + 20mA X4.b.30 X 1.1 Tx - X 1.2 Tx + X 1.7 RxD RS232 X 1.6 TxD RS232 HCPL 4100 S1* / J6 GND Tx X 3.2 X4.b.6 Rx X 3.1 X4.z.6 Exi 20mA Rx + J2 X4.z.30 =1 + + GND XOR =1 Exi XOR X4.z.28 X4.b.28 =1 XOR J8 =1 J3 / J3'* J7 + 1 + 5V X 4.3 X 4.2 X 4.1 B RS485 A RS485 J9* SW1* GND 1k 150R J8* 1k 0V 0V RTS Us_vr X4.d.32 X 1.5 X 1.9 +12V 50mA max. 0V X4.b.32 X4.z.32 X 2.2 X 2.4 +24V DC SI 1 GND Exi Us 3 Us2 Us1 GND GND GND X 3.8 X 3.5 X 3.3 X 3.7 X 3.6 X 3.4 X 5.b.28 X 4.d.2 X 4.d.6 X 4.z.2 X 4.z.4 X 4.b.4 The jumper settings shown in the diagram reflect delivery status! TDOCT-4038_ENG / 2015-01 11 3.4.2 Jumpers main circuit board J7 J8 J1 J2 1 1 1 1 1 J3 J4 J5 J6 1 Note The jumpers J5 and J6 are designed as wiper switches on the front panel for the ENT-DC-30 versions -19K, HS, and -AB. On the -19E version the jumpers must be placed on the circuit board. TDOCT-4038_ENG / 2015-01 12 J1 20 mA CL interface to PC / PLC J2 20 mA CL interface to PC / PLC receiving branch passive a b c d e sending branch passive a b c d e receiving branch active 1 ) sending branch active 1 ) a b c d e a b c d e For ENTDC-30-100-xx2** 1 feed circuit without RS 485 J3 logic level (X1) RS232 J4 logic level (X1) RS232 and 20 mA CL J5 (switch front panel) Rx (X1) RS232 or 20 mA CL J6 (switch front panel) Tx (X1) RS232 or 20 mA CL J7 TxD RS232 via 19" header J8 RxD RS232 via 19" header c b a c b a c b a c b a a b a b negated normal 1 ) b a c b a c b a c b a negated normal 1 ) 20 mA CL RS232 1 ) 20 mA CL RS232 1 ) sending branch activated 1 ) receiving branch activated 1 ) c a b a b sending branch not activated receiving branch not activated 1 ) reflect factory status! ** with all other versions placed on the additional circuit board. TDOCT-4038_ENG / 2015-01 13 3.4.3 Jumpers additional circuit board 1 J9 J3’ 1 1234 J8 J4’ 1 ON SW 1 SW1 prolongation of sender activation DIP 1 DIP 2 ON ON OFF ON OFF ON OFF OFF ON ON OFF ON OFF ON OFF OFF *) factory status DIP 3 ON ON ON ON OFF OFF OFF OFF J3’ logic level (X1) RS232 J4’ logic level (X1) RS232 and 20 mA CL Prolognation time 0,06 ms (153600 Baud) 0,12 ms (76800 Baud) 0,25 ms (38400 Baud) 0,49 ms (19200 Baud) 0,97 ms (9600 Baud) *) 1,95 ms (4800 Baud) 3,90 ms (2400 Baud) 7,81 ms (1200 Baud) c b a c b a normal 1 ) normal 1 ) negated c b a c b a negated J8 Look at RS 485 bus termination J9 Look at RS 485 bus termination TDOCT-4038_ENG / 2015-01 14 3.4.4 RS 485 bus termination For the ENT-DC-30 is an active bus data fixing necessary. In every ENT-DC-30 there is the possibility for an appropiate termination. For this the jumper J8 has to be put on position 2-3 and J9 put on position 1-2. The ENT-DC-30 which are in the midth of the bus the termination has not to be done ( J8 in position 1-2 and J9 in position 2-3 *) * factory status bus termination A B A J4 a J4 a b GND open B 2 A J4 a J4 a b b SK-485 1 2 3 J8 1 2 B b RS232 / 20mA CL 5V GND 3 open bus termination A J4 a J4 a b 5V GND RS232 / 20mA CL SK -485 1 open A B J4 a J4 a b b RS232 / 20mA CL 5V B J4 a J4 a b b RS232 / 20mA CL GND SK-485 5V b RS232 / 20mA CL GND 5V SK -485 SK- 48 3 :Termination J9 1 2 3 :NORMAL J9 J8 1 J9 1 J8 J3’ 1234 J4’ 1 ON SW 1 TDOCT-4038_ENG / 2015-01 15 3.4.5 Fuses SI 1 2 A slow blowing (type H 1500 A ) Warning The fuse SI 1 is safety relevant. Always use the correct type fuse. The fuse SI 1 is melted by an internal protection circuit of the ENT-DC if the supply voltage (24 VDC) increases to values above 32 V. This feature is safety relevant to protect the internal circuit from overloads. Warning The fuses SI 2 through SI 4 (round fine-wire fuses) may not be removed nor replaced. A defect in these fuses is unlikely. 3.4.6 S-ENT/PC-25 Connecting Cable ENT-DC-2.0 to PC (25 pin D-Sub) Cable for loading of projects from PC to a terminal (TERMEX) and for communication between TERMEX and PC. PC 25pin D-Sub male ENT-DC 9pin D-Sub female 2 3 1 Tx2 Tx+ RTS 4 CTS 5 6 TxD 7 RxD DSR 6 9 GND GND 7 DTR 20 housing TxD RxD TDOCT-4038_ENG / 2015-01 16 3.4.7 S-ENT/PC-9 Connecting Cable ENT-DC-30 to PC (9 pin D-Sub) Cable for loading of projects from PC to a terminal (TERMEX) and for communication between TERMEX and PC. PC 9pin D-Sub female RxD 2 ENT-DC 9pin D-Sub female 1 Tx- TxD 3 DTR 4 2 Tx+ 6 TxD GND 5 DSR 6 7 RxD 9 GND RTS 7 CTS 8 housing 3.4.8 S-ENT/MOUSE-9 Connecting Cable for Mouse ENT-DC-30 to PC (9 pin D-Sub) Cable required for mouse connection (EXTA-M.) to COM-port. PC 9pin D-Sub female RxD TxD ENT-DC 9pin D-Sub female 2 3 1 Tx2 Tx+ DTR 4 GND 5 6 TxD 7 RxD DSR 6 9 GND RTS 7 CTS 8 housing TDOCT-4038_ENG / 2015-01 17 3.4.9 DATL-A 4-10 Terminal Connection (1 feed circuit) ENT-DC-3.0 1 2 3 4 X3 .1 .2 .3 .4 DATL-A 4-10 connector: 1x STECKER-K04-508-S X3 .1 Rx .2 Tx .3 Us1 .4 GND X1 .1 Tx .2 Rx .3 Us1 .4 GND .5 nu .6 nu .7 nu .8 nu 1 2 3 4 PA X1 .1 .2 .3 .4 .5 .6 .7 .8 Terminal TERMEX 2xx / 3xx One connector (STECKER-K04-508-S) is part of the power supply. For this reason a DATL-A 4-0 can be used (without connector). 3.4.10 DATL-A 7-10 Terminal Connection (2 feed circuits) ENT-DC-3.0 X3 .1 .2 .3 .4 X3 .1 Rx .2 Tx .3 Us1 .4 GND 1 2 3 4 .5 .6 .7 .8 5 6 7 8 .5 .6 .7 .8 Us2 GND GND nu connector: 2x STECKER-K04-508-S DATL-A 7-10 X1 .1 Tx .2 Rx .3 Us1 .4 GND .5 Us2 .6 GND .7 GND .8 nu 1 2 3 4 5 6 7 PA X1 .1 .2 .3 .4 .5 .6 .7 .8 Terminal TERMEX 2xx / 3xx Two connectors (STECKER-K04-508-S) are part of the power supply. For this reason a DATL-A 7-0 can be used (without connector). TDOCT-4038_ENG / 2015-01 18 3.4.11 DATL-A 8-10 Terminal Connection (3 feed circuits) ENT-DC-3.0 X3 .1 .2 .3 .4 X3 .1 Rx .2 Tx .3 Us1 .4 GND 1 2 3 4 .5 .6 .7 .8 DATL-A 8-10 5 6 7 8 .5 .6 .7 .8 Us2 GND GND Us3 connector: 2x STECKER-K04-508-S X1 .1 Tx .2 Rx .3 Us1 .4 GND .5 Us2 .6 GND .7 GND .8 Us3 1 2 3 4 5 6 7 8 PA X1 .1 .2 .3 .4 .5 .6 .7 .8 Terminal TERMEX 2xx / 3xx Two connectors (STECKER-K04-508-S) are part of the power supply. For this reason a DATL-A 8-0 can be used (without connector). 3.4.12 DATL-A 4-3 Connecting cable ENT-DC to EXOM-DRAGON For fix mounting Plug connector with socket hub Clamping assembly female (Tx) 1 A Rx (Rx) 2 B Tx (Us) 3 C Us (GND) 4 D GND TDOCT-4038_ENG / 2015-01 19 3.4.13 Potential Equalization / Grounding The ENT-DC must be connected to a potential equalization at a PA-clamp (X2.1 X2.3). If 19" flush-type versions are used potential equalization is accomplished through a screw connection with the 19" rack. The 19" rack must be connected with PA. The intrinsically safe interface X3 may not be connected to potential equalization in the safe area which means that the shield of the line from the hazardous area may not be applied in the safe area. Refer to regulation VDE 0165. The data line to interface X1 must be shielded due to interference reasons. The shield must be applied on the ENT-DC side on PA. (PA via connector housing / jack). It is not necessary to shield the supply line (24V) to interface X2. An optional shield can be placed onto PA via X2.1. Safe Area Hazardous Area ENT-DC X3 .1 .2 .3 Exi-line .4 Exi Terminal X1 PC power supply 24V DC X2 .1 .3 .2 .4 Warning Compensating currents are generated by potential shifting which may cause electrical sparks. For this reason the shield of the hazardous line must be put in place in the hazardous area and not in the safe area. ENT-DC PC TxD RxD GND power supply +24V 24V DC GND TDOCT-4038_ENG / 2015-01 Warning RS232 connection RxD TxD GND polarity inversion ! +24V GND Polarity inversion of the supply voltage! Normally GND is connected to the PC housing. If a power supply is grounded and polarity has been inverted a short circuit will occur on the data interface of the ENT-DC which can destroy PC and ENT-DC. 20 3.5 Housing Top hat rail housing (1, 2, or 3 feed circuits) 68,2 168 ENT-DC X3 .1 LED Us2 .2 .5 .6 LED Us1 .3 .7 .4 .8 LED Us3 X1 X4 108 .1 .2 LED Tx .3 LED Rx X2 J5 .1 .2 .3 .4 RS485 TTY RS232 Mounting rail TS35 (hat profile) all measurements in mm Full housing (1, 2, or 3 feed circuits) 190 68,2 ENT-DC ENT-DC X3 X3 .1 .2 .3 .4 LED Us2 LED Us1 .5 .6 .7 .8 LED Us3 X1 X4 108 .1 .2 LED Tx .3 LED Rx X2 .1 .3 132 148 J5 .2 .4 RS485 TTY RS232 52,2 3 168 all measurements in mm TDOCT-4038_ENG / 2015-01 21 19E Slide-in card (1 feed circuit) 7 TE ENT-DC X3 .1 .2 LED Us1 .3 .4 X1 3 HE LED Tx LED Rx X2 .1 .2 .3 .4 19" row connector 19K Slide-in cassette (1, 2, or 3 feed circuits) 14 TE ENT-DC X3 .1 .2 LED Us2 LED Us1 .3 .5 .6 .7 .4 LED Us3 .8 X1 X4 3 HE .1 .2 LED Tx LED Rx X2 .3 J5 .1 .2 .3 .4 RS485 RS232 TTY RS485 TTY RS232 19" row connector TDOCT-4038_ENG / 2015-01 22 3.6 Instructions for Installation Attention To avoid heat traps in the ENT-DC-30 a minimum distance to other components is required. The ENT-DC-30 must be installed so that the cooling fins either point up or down. Other components can be placed closely to the sides of the ENT-DC-30. A minimum distance of 30 mm to other components must be maintained above and below the ENT-DC. This minimum distance holds for all housing versions -19K, -19E, -HS, -AB Minim um distanc e 30m m ENT-DC X3 .1 .1 .2 .3 . .6 6 .7 .7 .4 LED Us3 .8 .2 LED Us1 X1 LED Tx ENT-DC-30 ENT-DC X3 .5 LED Us2 .1 .2 .3 . .6 6 .7 .4 LED Us3 .8 LED Us1 X1 LEDRx X2 .1 .2 .3 .4 X6 X4 X4 .1 .2 .1 .2 .3 J5 RS485 TTY RS232 LEDTx LEDRx X2 .1 .2 .3 .4 .3 J5 RS485 TTY RS232 ENT-DC X3 .5 LED Us2 .1 .2 .3 ..6 6 .7 .7 .4 LED Us3 .8 LED Us1 X1 ENT-DC-30 ENT-DC X3 .5 LED Us2 .1 .2 .3 . .6 6 .7 .4 LED Us3 .8 LED Us1 X1 X6 .1 .2 LED Tx LEDRx X2 .1 .2 .3 .4 .3 J5 RS485 TTY RS232 LEDTx LEDRx X2 .1 .2 .3 .4 ENT-DC X3 .5 LED Us2 LED Us2 .5 .3 . .6 6 .7 .7 .4 LED Us3 .8 LED Us1 X1 X4 X4 .1 .2 .1 .2 .3 J5 RS485TTY RS232 LED Tx LEDRx X2 .1 .2 .3 .4 .3 J5 RS485 TTY RS232 Minim um distanc e 30m m Attention A minimum distance of 50 mm contour measure must be maintained between terminals in the safe and terminals in the hazardous area. This restriction holds true for connections in front and back. TDOCT-4038_ENG / 2015-01 23 3.7 Rating plates Warning The information contained on the nameplate constitutes maximum values for hazardous areas. The electrical maximum values must be maintained otherwise the devices will not function properly. Refer to the chapter “Specifications”. Example rating plate (depending upon variant): POWEX X 1.4 DMT 03 ATEX E 011 X HCPL 4200 S1* / J5 XOR J1 Ex-i Speisegerät / Supply ENT-DC-30-100-HS-2 II 2 G [EEx ib] IIC 22R Rx - 1 X 1.3 Rx + 0°C t u +50°C Fertigungs-Nr. / Serial number. 0608170384-01 Fertigungsjahr / Year of manufacture: 2006 Part No. 193958-0003 =1 + J4 / J4'* GND J2 1 + 20mA X 1.1 Tx - X 1.2 Tx + X 1.7 RxD RS232 X 1.6 TxD RS232 1 HCPL 4100 S1* / J6 GND Tx X 3.2 Rx X 3.1 Exi 20mA + GND XOR =1 Exi XOR =1 XOR J8 =1 J3 / J3'* J7 + + 5V X 4.3 X 4.2 X 4.1 J7 a b J8 a b J4 1k 150R J8* 1k 0V 0V RTS J1 J2 a b c d e J3 SW1* GND Us_vr TP3 TP2 TP1 B RS485 A RS485 J9* 1 J5 a b c d e J6 c b a c b a c b a c b a X 1.5 X 1.9 +12V 50mA max. 0V Us 3 Us2 Us1 X 2.2 X 2.4 +24V DC GND GND GND GND SI 1 Exi X X X X X X 3.8 3.5 3.3 3.7 3.6 3.4 4 Applied harmonized standards of the applicable directives This is an addition to Pepperl+Fuchs Declaration of Conformity in accordance with EN 45014:1998 in the appendix. Directives EC-directives 94/9EC (ATEX) TDOCT-4038_ENG / 2015-01 Applied harmonized standards EN 50014:1997 EN 50020:1994 24 5 Order designations Interface Housing ENT-DC 3. Supply circuit 2. Supply circuit 1. Supply circuit Type 5.1 Exi Power supply ENT-DC Type ENT-DC-30 IS Power Supply & Data Interface 1. Supply circuit 1 Ua = 8 la = 280 Pa = 1,2 2 Ua = 8,5 la = 280 Pa = 1,2 3 Ua = 9 la = 280 Pa = 1,2 4 Ua = 9 la = 290 Pa = 1,3 5 Ua = 9 la = 300 Pa = 1,4 6 Ua= 8,5 la = 240 Pa = 1,2 Long Range 7 Ua= 8,5 la = 240 Pa = 1,2 2. Supply circuit 0 Not configured 1 Ua = 8 la = 280 Pa = 1,2 2 Ua = 8,5 la = 280 Pa = 1,2 3 Ua = 9 la = 280 Pa = 1,2 4 Ua = 9 la = 290 Pa = 1,3 5 Ua = 9 la = 300 Pa = 1,4 6 Ua= 8,5 la = 240 Pa = 1,2 Long Range 7 Ua= 8,5 la = 240 Pa = 1,2 3. Supply circuit 0 Not configured 1 Ua = 8 la = 280 Pa = 1,2 2 Ua = 8,5 la = 280 Pa = 1,2 3 Ua = 9 la = 280 Pa = 1,2 4 Ua = 9 la = 290 Pa = 1,3 5 Ua = 9 la = 300 Pa = 1,4 6 Ua= 8,5 la = 240 Pa = 1,2 Long Range 7 Ua= 8,5 la = 240 Pa = 1,2 Housing ENT-DC HS DIN rail mountable AB Separate housing 19K 19'' slide in unit, IP 20 casing 19E 19'' slide in unit, no casing Interface 2 3 TDOCT-4038_ENG / 2015-01 TTY, RS232 TTY, RS232, RS485 25 Table Ex-values of feed circuits (X = 0 : not used) X 1 2 3 4 5 6 7 Ua [V] 8 8,5 9 9 9 8,5 8,5 Ia [mA] 280 280 280 290 300 240 240 Pa [W] 1,2 1,2 1,2 1,3 1,4 1,2 1,2 Distance of the devices to ... 230 m 230 m 230 m 230 m 230 m 440 m 230 m To the type code there may be attached further not safety-relevant markings. 5.2 Connectors For interface X1: CONNECTOR-SUB-D-09W (2 ENT-DC required) For interface X2: CONNECTOR-K02-381-O (2 ENT-DC required) For interface X3 CONNECTOR-K03-508-S (2 ENT-DC required) For interface X4 JACK-F96 (only versions -19K, -19E) For interface X5 JACK-F96 (only version -19K with 3 feed circuits) TDOCT-4038_ENG / 2015-01 26 6 Index Block Diagram 12 Data interface 9 Environmental conditions 7 Exi interface 8 Fuses 17 Grounding 21 Housing 6, 7, 22 Slide-in card 23 Slide-in cassette 23 Support 2 Warning 4, 5, 7, 17, 21, 25 Wiring 5, 12 TDOCT-4038_ENG / 2015-01 27 7 Appendix EEx Certification CERTIFIED TRANSLATION Ex DEKRA Addendum L (Amendment in accordance with Directive 94l9lEU Annex III Clause 6) to EC Type Examination Certificate DMT 03 ATEX E 011 X Equipment: Power Supply Unit Type ENT-DC-30-***-*'.* Manufacturer: Pepperl+Fuchs GmbH Address: D - 68307 Mannheim EXTEC Oesterle GmbH Formerly D - 73730 Esslingen Description The power supply unit can also be operated with modified Um values for the non-intrinsically safe supply circuit and the nonintrinsically safe signal circuits. The basic safety and health requirements of the modihed version are satisfied through conformance with EN 50014:1997 + Al - A2 EN 50020:1994 General requirements Intrinsic safety'i' The power supply unit was manufactured in accordance with EN 50014:1997 + Al - A2 General requirements, among other things, so this equipment continues to conform to the basic requirements of Directive 94l9lEU. The marking on the device must contain the following information: Ex II (2)G [EEx ib] IIC Parameters Non-intrinsically safe supply circuit and non-intrinsically safe signal circuits (connector X4, terminals 28 - 32 as well as connectors X2 and Xl) Rated voltage Um Max. voltage DC 24 AC 2s3 V V Page I of2 ofDMT 03 ATEX E 01 I X / Nl This certificate may only be passed on to others without change. DEKRA EXAM GmbH, Dinnendahlstrasse 9,D-44809 Bochum, Phone +49 (0)234/3696-105, Fax +49 (0)23413696-110, e-mail [email protected] (Until May 3 I, 2003: Deutsche Montan Technologie GmbH, Arn Technologiepark l, D-45307 Essen) ¡LLlSp LEGAL CERTIFICATION Y a I hereby certify that this is a complete and correct translation of the original document drawn up in the German languale Dâte: ZS.aT. Õ? D 7LLI (jl /4*- ;.: David Allison Officially appointed and sworn document translator for the English language at the Regional Court of Stuttgart in Baden-Württemberg, Federal Republic of Germany. '!'(;t...,¡.i I CERTIFIED TRANSLATION DEKRA Special conditions for safe usaee / instructions for use Unchanged Test Report BVS PP 03.2006 EU, dated February 21,2008 DEKRA EXAM GmbH Bochum, February 21, 2008 (Signature illegible) (Signature illegible) Certification body Department Page2of2 of DMT03 ATEXE0II X/Nl This certificate may only be passed on to others without change DEKRA EXAM GmbH, Dinnendahlstrasse 9, D-44809 Bochurn, Phone +49 (0)23413696-105, Fax +49 (0)23413696-110, e-mail [email protected] (Until May 31,2003: Deutsche Montan Technologie GmbH, Am Technologiçark 1, D45307 Essen) ¡LL I S6 lV LEGAL CERTIFICATION a I hereby certify that this is a complete and correct translation of the original document drawn up in the German language Date: 2 1. o3. O I ?/rL David Allison Officially appointed and sworn document tianslator for the English language at the Regional Court of Stuttgart in Baden-Württemberg, Federal Republic of Germany. LU (9 a è ENI
© Copyright 2026 Paperzz