Technical Manual

Technical Manual
Ex i Power supply ENT-DC-30
ENT-DC-30, TDOCT-4038_ENG, 2015-01
Pepperl+Fuchs GmbH Mannheim
Table of Content
1 Important Information ....................................................................................................................................... 1 1.1 General instructions .................................................................................................................................. 1 1.2 Safety instructions ..................................................................................................................................... 2 1.3 Symbols used in this manual .................................................................................................................... 3 2 Initial Operation ................................................................................................................................................ 4 3 ENT-DC Power Supply ..................................................................................................................................... 5 3.1 Operation ................................................................................................................................................... 5 3.2 Specifications ............................................................................................................................................ 6 3.3 Pin Assignment ......................................................................................................................................... 8 3.4 Wiring ......................................................................................................................................................11 3.4.1 Block Diagram ..................................................................................................................................11 3.4.2 Jumpers main circuit board ..............................................................................................................12 3.4.3 Jumpers additional circuit board ......................................................................................................14 3.4.4 RS 485 bus termination ...................................................................................................................15 3.4.5 Fuses ...............................................................................................................................................16 3.4.6 S-ENT/PC-25 Connecting Cable ENT-DC-2.0 to PC (25 pin D-Sub)..............................................16 3.4.7 S-ENT/PC-9 Connecting Cable ENT-DC-30 to PC (9 pin D-Sub) ...................................................17 3.4.8 S-ENT/MOUSE-9 Connecting Cable for Mouse ENT-DC-30 to PC (9 pin D-Sub) .........................17 3.4.9 DATL-A 4-10 Terminal Connection (1 feed circuit) ..........................................................................18 3.4.10 DATL-A 7-10 Terminal Connection (2 feed circuits) ........................................................................18 3.4.11 DATL-A 8-10 Terminal Connection (3 feed circuits) ........................................................................19 3.4.12 DATL-A 4-3 Connecting cable ENT-DC to EXOM-DRAGON .........................................................19 3.4.13 Potential Equalization / Grounding ..................................................................................................20 3.5 Housing ...................................................................................................................................................21 3.6 Instructions for Installation ......................................................................................................................23 3.7 Rating plates ...........................................................................................................................................24 4 Applied harmonized standards of the applicable directives ...........................................................................24 5 Order designations .........................................................................................................................................25 5.1 Exi Power supply ENT-DC ......................................................................................................................25 5.2 Connectors ..............................................................................................................................................26 6 Index ...............................................................................................................................................................27 7 Appendix EEx Certification .............................................................................................................................28 1 Important Information
1.1 General instructions
Copyright  2014 by Pepperl+Fuchs GmbH
All rights reserved
The publisher reserves the right to alter the information and data contained in this manual without prior notice.
Unless otherwise indicated, the company names as well as other names and data used in the examples are
purely fictitious.
The publisher may have registered patents or pending patent applications for subject matter covered in the
manual. This manual does not give you license to these patents.
Limited warranty:
No warranty is provided for the accuracy of the information contained in this manual. As mistakes cannot be
entirely avoided despite taking the greatest of care, we would be grateful to receive information about any errors
you may discover. The publisher disclaims all legal responsibility or liability for errors as well as for subsequent
damages and claims.
Publisher:
Pepperl-Fuchs GmbH
Lilienthalstr. 200
68307 Mannheim Deutschland
www.pepperl-fuchs.com
Tel. 0621-776-0
Fax 0621-776-1000
E-Mail: [email protected]
TDOCT-4038_ENG / 2015-01
1
1.2 Safety instructions
 These devices are only allowed to be installed and operated by trained and qualified
personnel who have received suitable instruction in their use.
 These devices represent state-of-art technology. They are only allowed to be connected to
systems that have been approved by Pepperl+Fuchs GmbH.
 Never open the devices yourself. They are only allowed to be opened by authorized
Pepperl+Fuchs GmbH personnel.
Pepperl+Fuchs GmbH is not liable for any resulting damages.
 The devices are not allowed to be modified or otherwise altered in any way.
Pepperl+Fuchs GmbH is not liable for any resulting damages.
 Please study the “Technical Manual ” carefully prior to starting up the devices.
 The most recent version of the “Technical Manual” is always valid. It is available on the
Support page of our web site (Internet address: http://www.pepperl-fuchs.com).
 The operating voltage of the devices must not exceed the limits indicated in the
"Technical Manual" under Technical data.
In the event of failure to comply, Pepperl+Fuchs GmbH is not liable for any resulting
damages.
 The relevant specifications for hazardous areas (e.g. EN 50178, EN 60079,
EN 50014 - 50039) and accident prevention regulations (e.g. UVV) must be observed.
 Only connect circuits to the device when the voltage of these circuits does not exceed the
values of a safety extra-low voltage (SELV) or a protective extra-low voltage (PELV).
 The device must be installed and operated only in surrounding enclosures that

comply with the requirements for surrounding enclosures according to
IEC/EN 60079-0,

are rated with the degree of protection IP54 according to IEC/EN 60529
Alternatively, it is permitted to install and operate the device in a monitored environment
that ensures a pollution degree 2 according to IEC/EN 60664-1.
 The installation instructions in accordance with IEC/EN 60079-14 must be observed.
 Close all unused connections with the corresponding covers to ensure the degree of
protection
 The technical data specified for the hazardous area corresponds to the certified values for
the European EEx approval. The user is responsible for ensuring that the devices are
suitable for their intended application and for the prevailing ambient conditions. No
warranty can be given by Pepperl+Fuchs GmbH in this connection.
Data subject to change without notice
TDOCT-4038_ENG / 2015-01
2
1.3 Symbols used in this manual
Warning:
The indicated specifications may not be modified.
Non-compliance may result in dangerous situations
and damages.
Caution:
Careful installation: do not replace electrical fuses
with fuses from different manufacturers. Noncompliance may result in dangerous situations and
damages.
Danger:
The product may possibly be negatively impacted or
damaged by foreign influences.
Non-hazardous
area:
Assembly and installation only in non-hazardous
areas.
Power supply cables for the hazardous areas zone 1
and zone 2 only with cable type DATL-A.
Danger:
Hazardous area
( Zone 1+2 )
All safety regulations as well as compliance
certificates for hazardous areas must be observed.
In addition, all regulations (VDE) published by the
respective authorities for the application of the
devices in hazardous areas (zone 1 and 2) must be
complied with at all times.
Additional Info:
Information and notices that must be observed
additionally.
Pressure load:
Significant mechanical pressure or impact loads
may result in damages.
TDOCT-4038_ENG / 2015-01
3
2 Initial Operation
This description for initial operation refers to those issues that must be considered with respect to the power
supply ENT-DC. Information with respect to operation of the peripherals connected to the ENT-DC power
supply can be found in the appropriate manual.
For operation proceed as follows:
 Switch off system or machine.
 Make sure that the assembly area is non-hazardous during the initial operation in case voltages are wired or
devices will be opened that are not intrinsically safe.
 Connect Exi power supply ENT-DC. Refer to the chapter “Wiring” for the appropriate connections.
 Connect protective ground wire to the power supply ENT-DC.
Warning
The protective ground wire runs along the housing. The
housing itself must be grounded. The wire for
connecting to ground must have a cross section of at
least 2.5 mm² and should be as short as possible.
 Connect power supply.
 Verify all functions.
 Switch on system or machine.
 Verify functions of the entire system or machine.
Warning
In case the ENT-DC has not been connected correctly
or its configuration is incorrect, malfunctioning of your
system/machine is possible.
Warning
The power supply ENT-DC is exclusively designed to
be integrated into a different machine. Operation may
not be initiated until conformity of the final product with
regulation 89/336/EC and 89/392/EC has been
established and the unit has been approved by a
specialist according to EN 60079 and EN 50014
respectively.
TDOCT-4038_ENG / 2015-01
4
3 ENT-DC Power Supply
The Exi power supply ENT-DC can be used in safe areas as a power supply for components in zone 1 and
zone 2. The ENT-DC provides up to 3 feed circuits and one 20 mA CL-interface. The ENT-DC can used to feed
all hazardous components which meet the interface specifications of the ENT-DC.
The most important data in brief:
Approval
Classification in accordance
[EEx ib] IIC
 II (2) G [EEx ib] IIC
with ATEX 95 RL94/9 EG:
DMT 03 ATEX E 011 X
Housing
Material
Protection type
Full, top hat rail, and 19" flush type housing
aluminum
IP 20
Number of feed circuits
Exi voltage Uamax
Exi current Ikmax
Exi power Pamax
1 - 3 feed circuits
7 V .. 9 V (according to configuration)
220 mA ..350 mA (according to configuration)
1.1 W .. 1.4 W (according to configuration)
Connections
connectors / terminal screws
3.1 Operation
To warrant sufficient ventilation, the ENT-DC must be set up as described under “Assembly” in chapter 3.6. The
slots for ventilation on the unit may not be covered so that heat dissipation is warranted.
TDOCT-4038_ENG / 2015-01
5
3.2 Specifications
Approval:
Protection type
Approval
Protection category:
[EEx ib] IIC
DMT 03 ATEX E 011 X
IP 20
Housing:
Material
Dimensions
Weight
Aluminum
refer to chapter “Housing”
app. 1.0 kg
Environmental conditions during operation:
Temperature range
0 °C - + 50 °C
Humidity
max. 85 % non-condensating (48 h stress test)
Warning
The ENT-DC may only be set up and operated in a
non-hazardous area.
Environmental conditions storage:
Temperature range
X1 data interface:
Data
Baudrate
Connector
Voltage Un
X2 interface power supply:
Voltage Un
Drawing of current
-20 °C - +70 °C
20 mA CL active/passive, zero potential
RS232
19.200 Baud (38.000 Baud on request)
9-pin D-Sub integrated jack, pin contacts
≤ |±15| V DC
24 V DC ±10%
1 feed circuit: app. 380 mA continuous current
2 feed circuits: appear. 550 mA continuous current
3 feed circuits: appear. 720 mA continuous current
Fuse SI 1
is safety relevant. Always use the correct fuse type.
2A slow blowing (type H 1500 A)
Connector
2 x 2-pin integrated jack / pin contacts, for CONNECTOR-K02-381-O
TDOCT-4038_ENG / 2015-01
6
X3 Exi interface:
Data
Voltage supply
Connector
20 mA CL active/active switched to plus
Version
Ua [V] Ia [mA] Pa [W]
...-1..-...
8
280
1.2
...-2..-...
8.5
280
1.2
...-3..-...
9
280
1.2
...-4..-...
9
290
1.3
...-5..-...
9
300
1.4
...-6..-...
8,5
240
1,2
2 x 4-pin integrated jack / pin contacts, for CONNECTOR-K04-508-S
Note
Additional output according to the approval described in
the appendix can be provided upon request.
X4, X5 Exi interface (only for 19" versions -19K, -19E):
Signals according to X3 Exi-interface
Connector
96-pin spring contact strip DIN 41612 (not all springs equipped)
TDOCT-4038_ENG / 2015-01
7
3.3 Pin Assignment
For the top hat rail and full housing version of the ENT-DC-2 all connections are made in the front. For the 19"version connections can be made in the front and in the rear. All connections can be reached from the front and
the back.
The connections X2, X3 and X4 are carried out as terminal screw-/plug-in terminals. The connection X1
constitutes a D-Sub jack. If the power supply operates with one feed circuit the connection X3 has four contacts.
If 2 or 3 feed circuits are in use the connection X3 has 8 contacts.
Front elevation:
1 feed circuit:
ENT-DC
X3
.1
.2
2 or 3 feed circuits:
ENT-DC
X3
.1
.2
LED Us1
.3
.4
LED Us2
..6
6
.7
LED Us1
.3
.4
X1
.5
LED Us3
.8
X1
X4
LED Tx
LED Rx
TTY
RS232
X2
.1
.3
.1
.2
J5
LED Tx
.2
.4
LED Rx
X2
.1
.3
.2
.4
.3
J5
RS485 TTY RS232
Interface X1
Data interface for safe area (PC)
9-pin D-Sub jack with pins
X1.1
X1.2
X1.3
X1.4
X1.5
X1.6
X1.7
X1.8
X1.9
TxTx+
Rx+
Rx+12V
TxD
RxD
nc
GND
(20 mA CL interface)
(20 mA CL interface)
(20 mA CL interface)
(20 mA CL interface)
(max. 50 mA)
(RS232 interface)
(RS232 interface)
X2.1
X2.2
X2.3
X2.4
PA
+ 24V DC
PA
GND
(RS232 interface)
Interface X2
Supply interface (24 VDC)
4-pin terminal block 0.5 mm² - 2.5 mm²
TDOCT-4038_ENG / 2015-01
8
Interface X3
Data- / supply interface hazardous area
2 x 4-pin terminal screw-/plug-in terminal
X3.1
X3.2
X3.3
X3.4
X3.5
X3.6
X3.7
X3.8
Rx
Tx
Us1
GND
Us2
GND
GND
Us3
X4.1
X4.2
X4.3
GND
RS485 A
RS485 B
(only assigned if 2 feed circuits)
(only assigned if 2 feed circuits)
(only assigned if 2 feed circuits)
(only assigned if 2 feed circuits)
Interface X4 on front
Optional data interface RS 485 to safe area
3-pin termianl screw-/plug-in terminal
TDOCT-4038_ENG / 2015-01
9
Rear elevation:
19E with 1 feed circuit:
19K with 1 or 2 feed circuits:
X4 .d .b .z
19K with 3 feed circuits:
X4 .d .b .z
X4 .d .b .z
.2
.4
.6
.2
.4
.6
.28
.30
.32
.28
.30
.32
.30
.28
.2
.4
.6
.28
.30
.32
X5 .z .b .d
Interface X4 DIN jack
Combi-interface 1. and 2. feed circuit
X4.d.2 Us2 (Exi)
X4.d.6 Us1 (Exi)
X4.b.4 GND (Exi)
X4.b.6 Tx20 (Exi)
X4.z.2 GND (Exi)
X4.z.4 GND (Exi)
X4.z.6 Rx20 (Exi)
X4.d.28 RxX4.d.30 Rx+
X4.d.32 Vdd
X4.b.28 TxD
X4.b.30 Tx+
X4.b.32 +24 V
X4.z.28 RxD
X4.z.30 TxX4.z.32 GND
X5.z.30 GND (Exi)
X5.z.28 GND (Exi)
X5.b.30 GND (Exi)
X5.b.28 Us3 (Exi)
X5.d.30 GND (Exi)
X5.d.28 Us3 (Exi)
F-strip (96 pin, not all contacts equipped)
Interface X5
Combi interface 3. feed circuit
F-strip (96 pin, not all contacts equipped)
Note
For the 19" installation and 3 feed circuits a second
F-strip is located in the rear of the housing. The second
F-strip is turned for installation purposes.
TDOCT-4038_ENG / 2015-01
10
3.4 Wiring
All connections for the ENT-DC are made in the front.
All clamps are also directed to the 19” header for the 19" flush type version. Hence connections can be made in
the rear or combined in front and rear.
Note
If connections are made in the front and rear the same
signals should not be assigned in the front and rear at
the same time. Proper operation of the ENT-DC may be
endangered in this case. (Issues with respect to safety
are not impacted).
3.4.1 Block Diagram
X4.d.28
X 1.4
22R
Rx -
HCPL 4200
S1* / J5
XOR
J1
1
X4.d.30
X 1.3
J4 / J4'*
GND
1
1
+
20mA
X4.b.30
X 1.1
Tx -
X 1.2
Tx +
X 1.7
RxD RS232
X 1.6
TxD RS232
HCPL 4100
S1* / J6
GND
Tx
X 3.2
X4.b.6
Rx
X 3.1
X4.z.6
Exi
20mA
Rx +
J2
X4.z.30
=1
+
+
GND
XOR
=1
Exi
XOR
X4.z.28
X4.b.28
=1
XOR
J8
=1
J3 / J3'*
J7
+
1
+ 5V
X 4.3
X 4.2
X 4.1
B RS485
A RS485
J9*
SW1*
GND
1k
150R
J8*
1k
0V
0V
RTS
Us_vr
X4.d.32
X 1.5
X 1.9
+12V 50mA max.
0V
X4.b.32
X4.z.32
X 2.2
X 2.4
+24V DC
SI 1
GND
Exi
Us 3
Us2
Us1
GND
GND
GND
X 3.8
X 3.5
X 3.3
X 3.7
X 3.6
X 3.4
X 5.b.28
X 4.d.2
X 4.d.6
X 4.z.2
X 4.z.4
X 4.b.4
The jumper settings shown in the diagram reflect delivery status!
TDOCT-4038_ENG / 2015-01
11
3.4.2 Jumpers main circuit board
J7
J8
J1 J2
1
1
1
1
1
J3
J4
J5
J6
1
Note
The jumpers J5 and J6 are designed as wiper switches
on the front panel for the ENT-DC-30 versions -19K, HS, and -AB.
On the -19E version the jumpers must be placed on the
circuit board.
TDOCT-4038_ENG / 2015-01
12
J1
20 mA CL interface to PC / PLC
J2
20 mA CL interface to PC / PLC
receiving
branch
passive
a
b
c
d
e
sending branch
passive
a
b
c
d
e
receiving
branch
active
1
)
sending branch
active
1
)
a
b
c
d
e
a
b
c
d
e
For ENTDC-30-100-xx2**
1 feed circuit without RS 485
J3
logic level (X1) RS232
J4
logic level (X1) RS232 and 20 mA CL
J5 (switch front panel)
Rx (X1) RS232 or 20 mA CL
J6 (switch front panel)
Tx (X1) RS232 or 20 mA CL
J7
TxD RS232 via 19" header
J8
RxD RS232 via 19" header
c
b a
c
b a
c
b a
c
b a
a
b
a
b
negated
normal
1
)
b a
c
b a
c
b a
c
b a
negated
normal
1
)
20 mA CL
RS232
1
)
20 mA CL
RS232
1
)
sending branch
activated
1
)
receiving
branch
activated
1
)
c
a
b
a
b
sending branch
not activated
receiving
branch
not activated
1
) reflect factory status!
** with all other versions placed on the additional circuit board.
TDOCT-4038_ENG / 2015-01
13
3.4.3 Jumpers additional circuit board
1
J9
J3’
1
1234
J8
J4’
1
ON
SW 1
SW1 prolongation of sender activation
DIP 1
DIP 2
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
OFF
*) factory status
DIP 3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
J3’
logic level (X1) RS232
J4’
logic level (X1) RS232 and 20 mA CL
Prolognation time
0,06 ms (153600 Baud)
0,12 ms (76800 Baud)
0,25 ms (38400 Baud)
0,49 ms (19200 Baud)
0,97 ms (9600 Baud) *)
1,95 ms (4800 Baud)
3,90 ms (2400 Baud)
7,81 ms (1200 Baud)
c
b a
c
b a
normal
1
)
normal
1
)
negated
c
b a
c
b a
negated
J8
Look at RS 485 bus termination
J9
Look at RS 485 bus termination
TDOCT-4038_ENG / 2015-01
14
3.4.4 RS 485 bus termination
For the ENT-DC-30 is an active bus data fixing necessary. In every ENT-DC-30 there is the possibility for an
appropiate termination. For this the jumper J8 has to be put on position 2-3 and J9 put on position 1-2. The
ENT-DC-30 which are in the midth of the bus the termination has not to be done ( J8 in position 1-2 and J9 in
position 2-3 *)
* factory status
bus termination
A
B
A
J4 a J4 a
b
GND
open
B
2
A
J4 a J4 a
b
b
SK-485
1
2
3
J8
1 2
B
b
RS232 / 20mA CL
5V
GND
3
open
bus termination
A
J4 a J4 a
b
5V
GND
RS232 / 20mA CL
SK -485
1
open
A
B
J4 a J4 a
b
b
RS232 / 20mA CL
5V
B
J4 a J4 a
b
b
RS232 / 20mA CL
GND
SK-485
5V
b
RS232 / 20mA CL
GND
5V
SK -485
SK- 48
3
:Termination
J9
1 2
3
:NORMAL
J9
J8
1
J9
1
J8
J3’
1234
J4’
1
ON
SW 1
TDOCT-4038_ENG / 2015-01
15
3.4.5 Fuses
SI 1
2 A slow blowing (type H 1500 A )
Warning
The fuse SI 1 is safety relevant. Always use the correct
type fuse.
The fuse SI 1 is melted by an internal protection circuit of the ENT-DC if the supply voltage (24 VDC) increases
to values above 32 V. This feature is safety relevant to protect the internal circuit from overloads.
Warning
The fuses SI 2 through SI 4 (round fine-wire fuses) may
not be removed nor replaced.
A defect in these fuses is unlikely.
3.4.6 S-ENT/PC-25 Connecting Cable ENT-DC-2.0 to PC (25 pin D-Sub)
Cable for loading of projects from PC to a terminal (TERMEX) and for communication between TERMEX and
PC.
PC
25pin D-Sub male
ENT-DC
9pin D-Sub female
2
3
1 Tx2 Tx+
RTS 4
CTS 5
6 TxD
7 RxD
DSR 6
9 GND
GND 7
DTR 20
housing
TxD
RxD
TDOCT-4038_ENG / 2015-01
16
3.4.7 S-ENT/PC-9 Connecting Cable ENT-DC-30 to PC (9 pin D-Sub)
Cable for loading of projects from PC to a terminal (TERMEX) and for communication between TERMEX and
PC.
PC
9pin D-Sub female
RxD
2
ENT-DC
9pin D-Sub female
1 Tx-
TxD 3
DTR 4
2 Tx+
6 TxD
GND 5
DSR 6
7 RxD
9 GND
RTS 7
CTS 8
housing
3.4.8 S-ENT/MOUSE-9 Connecting Cable for Mouse ENT-DC-30 to PC (9 pin D-Sub)
Cable required for mouse connection (EXTA-M.) to COM-port.
PC
9pin D-Sub female
RxD
TxD
ENT-DC
9pin D-Sub female
2
3
1 Tx2 Tx+
DTR 4
GND 5
6 TxD
7 RxD
DSR 6
9 GND
RTS 7
CTS 8
housing
TDOCT-4038_ENG / 2015-01
17
3.4.9 DATL-A 4-10 Terminal Connection (1 feed circuit)
ENT-DC-3.0
1
2
3
4
X3
.1
.2
.3
.4
DATL-A 4-10
connector:
1x STECKER-K04-508-S
X3
.1 Rx
.2 Tx
.3 Us1
.4 GND
X1
.1 Tx
.2 Rx
.3 Us1
.4 GND
.5 nu
.6 nu
.7 nu
.8 nu
1 2 3 4
PA
X1 .1 .2 .3 .4 .5 .6 .7 .8
Terminal
TERMEX 2xx / 3xx
One connector (STECKER-K04-508-S) is part of the power supply. For this reason a DATL-A 4-0 can be used
(without connector).
3.4.10 DATL-A 7-10 Terminal Connection (2 feed circuits)
ENT-DC-3.0
X3
.1
.2
.3
.4
X3
.1 Rx
.2 Tx
.3 Us1
.4 GND
1
2
3
4
.5
.6
.7
.8
5
6
7
8
.5
.6
.7
.8
Us2
GND
GND
nu
connector:
2x STECKER-K04-508-S
DATL-A 7-10
X1
.1 Tx
.2 Rx
.3 Us1
.4 GND
.5 Us2
.6 GND
.7 GND
.8 nu
1 2 3 4 5 6 7
PA
X1 .1 .2 .3 .4 .5 .6 .7 .8
Terminal
TERMEX 2xx / 3xx
Two connectors (STECKER-K04-508-S) are part of the power supply. For this reason a DATL-A 7-0 can be
used (without connector).
TDOCT-4038_ENG / 2015-01
18
3.4.11 DATL-A 8-10 Terminal Connection (3 feed circuits)
ENT-DC-3.0
X3
.1
.2
.3
.4
X3
.1 Rx
.2 Tx
.3 Us1
.4 GND
1
2
3
4
.5
.6
.7
.8
DATL-A 8-10
5
6
7
8
.5
.6
.7
.8
Us2
GND
GND
Us3
connector:
2x STECKER-K04-508-S
X1
.1 Tx
.2 Rx
.3 Us1
.4 GND
.5 Us2
.6 GND
.7 GND
.8 Us3
1 2 3 4 5 6 7 8
PA
X1 .1 .2 .3 .4 .5 .6 .7 .8
Terminal
TERMEX 2xx / 3xx
Two connectors (STECKER-K04-508-S) are part of the power supply. For this reason a DATL-A 8-0 can be
used (without connector).
3.4.12 DATL-A 4-3 Connecting cable ENT-DC to EXOM-DRAGON
For fix mounting
Plug connector with socket hub
Clamping assembly
female
(Tx)
1
A
Rx
(Rx)
2
B
Tx
(Us)
3
C
Us
(GND) 4
D
GND
TDOCT-4038_ENG / 2015-01
19
3.4.13 Potential Equalization / Grounding
The ENT-DC must be connected to a potential equalization at a PA-clamp (X2.1 X2.3). If 19" flush-type versions
are used potential equalization is accomplished through a screw connection with the 19" rack. The 19" rack
must be connected with PA.
The intrinsically safe interface X3 may not be connected to potential equalization in the safe area which means
that the shield of the line from the hazardous area may not be applied in the safe area. Refer to regulation VDE
0165.
The data line to interface X1 must be shielded due to interference reasons. The shield must be applied on the
ENT-DC side on PA. (PA via connector housing / jack).
It is not necessary to shield the supply line (24V) to interface X2. An optional shield can be placed onto PA via
X2.1.
Safe Area
Hazardous Area
ENT-DC
X3
.1
.2
.3
Exi-line
.4
Exi Terminal
X1
PC
power
supply
24V DC
X2
.1
.3
.2
.4
Warning
Compensating currents are generated by potential
shifting which may cause electrical sparks.
For this reason the shield of the hazardous line must be
put in place in the hazardous area and not in the safe
area.
ENT-DC
PC
TxD
RxD
GND
power supply
+24V
24V DC
GND
TDOCT-4038_ENG / 2015-01
Warning
RS232 connection
RxD
TxD
GND
polarity
inversion !
+24V
GND
Polarity inversion of the supply
voltage!
Normally GND is connected to the PC
housing. If a power supply is
grounded and polarity has been
inverted a short circuit will occur on
the data interface of the ENT-DC
which can destroy PC and ENT-DC.
20
3.5 Housing
Top hat rail housing (1, 2, or 3 feed circuits)
68,2
168
ENT-DC
X3
.1
LED Us2
.2
.5
.6
LED Us1
.3
.7
.4
.8
LED Us3
X1
X4
108
.1
.2
LED Tx
.3
LED Rx
X2
J5
.1
.2
.3
.4
RS485 TTY RS232
Mounting rail TS35
(hat profile)
all measurements in mm
Full housing (1, 2, or 3 feed circuits)
190
68,2
ENT-DC
ENT-DC
X3
X3
.1
.2
.3
.4
LED Us2
LED Us1
.5
.6
.7
.8
LED Us3
X1
X4
108
.1
.2
LED Tx
.3
LED Rx
X2
.1
.3
132 148
J5
.2
.4
RS485 TTY RS232
52,2
3
168
all measurements in mm
TDOCT-4038_ENG / 2015-01
21
19E Slide-in card (1 feed circuit)
7 TE
ENT-DC
X3
.1
.2
LED Us1
.3
.4
X1
3 HE
LED Tx
LED Rx
X2
.1
.2
.3
.4
19" row connector
19K Slide-in cassette (1, 2, or 3 feed circuits)
14 TE
ENT-DC
X3
.1
.2
LED Us2
LED Us1
.3
.5
.6
.7
.4
LED Us3
.8
X1
X4
3 HE
.1
.2
LED Tx
LED Rx
X2
.3
J5
.1
.2
.3
.4
RS485 RS232 TTY
RS485 TTY RS232
19" row connector
TDOCT-4038_ENG / 2015-01
22
3.6 Instructions for Installation
Attention
To avoid heat traps in the ENT-DC-30 a minimum
distance to other components is required.
The ENT-DC-30 must be installed so that the cooling
fins either point up or down.
 Other components can be placed closely to the sides of the ENT-DC-30.
 A minimum distance of  30 mm to other components must be maintained above and below the ENT-DC.
 This minimum distance holds for all housing versions -19K, -19E, -HS, -AB
Minim um distanc e 30m m
ENT-DC
X3
.1
.1
.2
.3
.
.6
6
.7
.7
.4
LED Us3 .8
.2
LED Us1
X1
LED Tx
ENT-DC-30
ENT-DC
X3
.5
LED Us2
.1
.2
.3
.
.6
6
.7
.4
LED Us3 .8
LED Us1
X1
LEDRx
X2
.1
.2
.3
.4
X6
X4
X4
.1
.2
.1
.2
.3
J5
RS485 TTY RS232
LEDTx
LEDRx
X2
.1
.2
.3
.4
.3
J5
RS485 TTY RS232
ENT-DC
X3
.5
LED Us2
.1
.2
.3
..6
6
.7
.7
.4
LED Us3 .8
LED Us1
X1
ENT-DC-30
ENT-DC
X3
.5
LED Us2
.1
.2
.3
.
.6
6
.7
.4
LED Us3 .8
LED Us1
X1
X6
.1
.2
LED Tx
LEDRx
X2
.1
.2
.3
.4
.3
J5
RS485 TTY RS232
LEDTx
LEDRx
X2
.1
.2
.3
.4
ENT-DC
X3
.5
LED Us2
LED Us2
.5
.3
.
.6
6
.7
.7
.4
LED Us3 .8
LED Us1
X1
X4
X4
.1
.2
.1
.2
.3
J5
RS485TTY RS232
LED Tx
LEDRx
X2
.1
.2
.3
.4
.3
J5
RS485 TTY RS232
Minim um distanc e 30m m
Attention
A minimum distance of 50 mm contour measure must
be maintained between terminals in the safe and
terminals in the hazardous area.
This restriction holds true for connections in front and
back.
TDOCT-4038_ENG / 2015-01
23
3.7 Rating plates
Warning
The information contained on the nameplate constitutes
maximum values for hazardous areas. The electrical
maximum values must be maintained otherwise the
devices will not function properly. Refer to the chapter
“Specifications”.
Example rating plate (depending upon variant):
POWEX
X 1.4
DMT 03 ATEX E 011 X
HCPL 4200
S1* / J5
XOR
J1
Ex-i Speisegerät / Supply ENT-DC-30-100-HS-2


II 2 G [EEx ib] IIC
22R
Rx -
1
X 1.3
Rx +
0°C t u +50°C
Fertigungs-Nr. / Serial number.
0608170384-01
Fertigungsjahr / Year of manufacture: 2006
Part No.
193958-0003
=1
+
J4 / J4'*
GND
J2
1
+
20mA
X 1.1
Tx -
X 1.2
Tx +
X 1.7
RxD RS232
X 1.6
TxD RS232
1
HCPL 4100
S1* / J6
GND
Tx
X 3.2
Rx
X 3.1
Exi
20mA
+
GND
XOR
=1
Exi
XOR
=1
XOR
J8
=1
J3 / J3'*
J7
+
+ 5V
X 4.3
X 4.2
X 4.1
J7
a
b
J8
a
b
J4
1k
150R
J8*
1k
0V
0V
RTS
J1 J2
a
b
c
d
e
J3
SW1*
GND
Us_vr
TP3
TP2
TP1
B RS485
A RS485
J9*
1
J5
a
b
c
d
e
J6
c b a c b a c b a c b a
X 1.5
X 1.9
+12V 50mA max.
0V
Us 3
Us2
Us1
X 2.2
X 2.4
+24V DC
GND
GND
GND
GND
SI 1
Exi
X
X
X
X
X
X
3.8
3.5
3.3
3.7
3.6
3.4
4 Applied harmonized standards of the applicable directives
This is an addition to Pepperl+Fuchs Declaration of Conformity in accordance with EN 45014:1998 in the
appendix.
Directives
EC-directives
94/9EC (ATEX)
TDOCT-4038_ENG / 2015-01
Applied harmonized standards
EN 50014:1997
EN 50020:1994
24
5 Order designations
Interface
Housing
ENT-DC
3.
Supply
circuit
2.
Supply
circuit
1.
Supply
circuit
Type
5.1 Exi Power supply ENT-DC
Type
ENT-DC-30 IS Power Supply & Data Interface
1. Supply circuit
1 Ua = 8 la = 280 Pa = 1,2
2 Ua = 8,5 la = 280 Pa = 1,2
3 Ua = 9 la = 280 Pa = 1,2
4 Ua = 9 la = 290 Pa = 1,3
5 Ua = 9 la = 300 Pa = 1,4
6 Ua= 8,5 la = 240 Pa = 1,2 Long Range
7 Ua= 8,5 la = 240 Pa = 1,2
2. Supply circuit
0 Not configured
1 Ua = 8 la = 280 Pa = 1,2
2 Ua = 8,5 la = 280 Pa = 1,2
3 Ua = 9 la = 280 Pa = 1,2
4 Ua = 9 la = 290 Pa = 1,3
5 Ua = 9 la = 300 Pa = 1,4
6 Ua= 8,5 la = 240 Pa = 1,2 Long Range
7 Ua= 8,5 la = 240 Pa = 1,2
3. Supply circuit
0 Not configured
1 Ua = 8 la = 280 Pa = 1,2
2 Ua = 8,5 la = 280 Pa = 1,2
3 Ua = 9 la = 280 Pa = 1,2
4 Ua = 9 la = 290 Pa = 1,3
5 Ua = 9 la = 300 Pa = 1,4
6 Ua= 8,5 la = 240 Pa = 1,2 Long Range
7 Ua= 8,5 la = 240 Pa = 1,2
Housing ENT-DC
HS DIN rail mountable
AB Separate housing
19K 19'' slide in unit, IP 20 casing
19E 19'' slide in unit, no casing
Interface
2
3
TDOCT-4038_ENG / 2015-01
TTY, RS232
TTY, RS232, RS485
25
Table Ex-values of feed circuits (X = 0 : not used)
X
1
2
3
4
5
6
7
Ua [V]
8
8,5
9
9
9
8,5
8,5
Ia [mA]
280
280
280
290
300
240
240
Pa [W]
1,2
1,2
1,2
1,3
1,4
1,2
1,2
Distance of the devices to ...
230 m
230 m
230 m
230 m
230 m
440 m
230 m
To the type code there may be attached further not safety-relevant markings.
5.2 Connectors
For interface X1:
CONNECTOR-SUB-D-09W
(2 ENT-DC required)
For interface X2:
CONNECTOR-K02-381-O
(2 ENT-DC required)
For interface X3
CONNECTOR-K03-508-S
(2 ENT-DC required)
For interface X4
JACK-F96
(only versions -19K, -19E)
For interface X5
JACK-F96
(only version -19K with 3 feed circuits)
TDOCT-4038_ENG / 2015-01
26
6 Index
Block Diagram 12
Data interface 9
Environmental conditions 7
Exi interface 8
Fuses 17
Grounding 21
Housing 6, 7, 22
Slide-in card 23
Slide-in cassette 23
Support 2
Warning 4, 5, 7, 17, 21, 25
Wiring 5, 12
TDOCT-4038_ENG / 2015-01
27
7 Appendix EEx Certification
CERTIFIED TRANSLATION
Ex
DEKRA
Addendum L
(Amendment in accordance with Directive 94l9lEU Annex III Clause 6)
to EC Type Examination Certificate
DMT 03 ATEX E 011 X
Equipment:
Power Supply Unit Type ENT-DC-30-***-*'.*
Manufacturer:
Pepperl+Fuchs GmbH
Address:
D
-
68307 Mannheim
EXTEC Oesterle GmbH
Formerly
D
-
73730 Esslingen
Description
The power supply unit can also be operated with modified Um values for the non-intrinsically safe supply circuit and the nonintrinsically safe signal circuits.
The basic safety and health requirements of the modihed version are satisfied through conformance with
EN 50014:1997 + Al - A2
EN 50020:1994
General requirements
Intrinsic safety'i'
The power supply unit was manufactured in accordance with EN 50014:1997 + Al - A2 General requirements, among other
things, so this equipment continues to conform to the basic requirements of Directive 94l9lEU.
The marking on the device must contain the following information:
Ex
II
(2)G [EEx ib] IIC
Parameters
Non-intrinsically safe supply circuit and non-intrinsically safe signal circuits
(connector X4, terminals 28 - 32 as well as connectors X2 and Xl)
Rated voltage
Um
Max. voltage
DC
24
AC
2s3
V
V
Page I of2 ofDMT 03 ATEX E 01 I X / Nl
This certificate may only be passed on to others without change.
DEKRA EXAM GmbH, Dinnendahlstrasse 9,D-44809 Bochum, Phone +49 (0)234/3696-105, Fax +49 (0)23413696-110, e-mail [email protected]
(Until May 3 I, 2003: Deutsche Montan Technologie GmbH, Arn Technologiepark l, D-45307 Essen)
¡LLlSp
LEGAL CERTIFICATION
Y
a
I hereby certify that this is a complete and correct translation of the original
document drawn up in the German languale
Dâte:
ZS.aT. Õ? D
7LLI
(jl
/4*-
;.:
David Allison
Officially appointed and sworn document translator for the English language at the
Regional Court of Stuttgart in Baden-Württemberg, Federal Republic of Germany.
'!'(;t...,¡.i
I
CERTIFIED TRANSLATION
DEKRA
Special conditions for safe usaee / instructions for use
Unchanged
Test Report
BVS PP 03.2006 EU, dated February 21,2008
DEKRA EXAM GmbH
Bochum, February 21, 2008
(Signature illegible)
(Signature illegible)
Certification body
Department
Page2of2 of DMT03 ATEXE0II X/Nl
This certificate may only be passed on to others without change
DEKRA EXAM GmbH, Dinnendahlstrasse 9, D-44809 Bochurn, Phone +49 (0)23413696-105, Fax +49 (0)23413696-110, e-mail [email protected]
(Until May 31,2003: Deutsche Montan Technologie GmbH, Am Technologiçark 1, D45307 Essen)
¡LL I S6 lV
LEGAL CERTIFICATION
a
I hereby certify that this is a complete and correct translation of the original
document drawn up in the German language
Date: 2
1.
o3.
O
I
?/rL
David Allison
Officially appointed and sworn document tianslator for the English language at the
Regional Court of Stuttgart in Baden-Württemberg, Federal Republic of Germany.
LU
(9
a
è
ENI