PA C KA G E D E L E C T R I C / e l e c t r i c KCa Landmark® Rooftop Units Standard Efficiency - 60 HZ Bulletin No. 210788 June 2017 P R O D U C T S P E C I F I C AT I O N S Supersedes February 2017 ASHRAE 90.1 COMPLIANT 3 to 7.5 Tons Net Cooling Capacity - 36,200 to 90,000 Btuh Optional Electric Heat - 7.5 to 30 kW MODEL NUMBER IDENTIFICATION K C A 060 S 4 B N 1 Y Brand/Family K = Landmark® Product Line Voltage P = 208/230V-1 phase-60hz Y = 208/230V-3 phase-60hz G = 460V-3 phase-60hz J = 575V-3 phase-60hz Unit Type C = Packaged Electric Cooling w/ optional Electric Heat Minor Design Sequence 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Major Design Sequence A = 1st Generation Nominal Cooling Capacity - Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons 090 = 7.5 Tons Cooling Efficiency S = Standard Efficiency Factory Installed Electric Heat N = No Heat Blower Type D = Direct Drive B = Belt Drive Refrigerant Type 4 = R-410A FEATURES AND BENEFITS F I K N E D C M B H L G J KCA090S (Cooling with Optional Electric Heat) Shown With Optional Electric Heat, Economizer, Power Exhaust and Hinged Access Panels Landmark® rooftop units from Lennox® are the new standard for reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor environments. Landmark® rooftop units feature: • • • • • • • • • • • R-410A Refrigerant - Environmentally friendly. Single Speed Scroll Compressor - Furnished on all models. Lennox’ Environ™ Coil System (KCA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer. High Pressure Switches - Protect compressor. Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow. Direct or Belt Drive Blower Motors - Direct drive (036, 048 and 060 models). Belt drive motors (all models) to maximize air performance. Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel. Downflow or Horizontal Airflow - Easy field conversion. Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability. Common Components - Many maintenance items are standard throughout the entire product line, reducing the need to carry different parts to the job or maintain in inventory. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 2 FEATURES AND BENEFITS CONTENTS Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Dimensions - Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 37 Dimensions - Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Electrical/Electric Heat Data . . . . . . . . . . . . . . . . . . . . . . . . 28 Electric Heat Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Features And Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Model Number Identification . . . . . . . . . . . . . . . . . . . . . . . . .1 Optional Conventional Temperature Control Systems . . . . . . . . . . . 34 Options / Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Outdoor Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Specifications - Belt Drive Blower . . . . . . . . . . . . . . . . . . . . . 13 Specifications - Direct Drive Blower . . . . . . . . . . . . . . . . . . . . 12 Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Weight Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 APPROVALS AHRI Certified to AHRI Standard 210/240-2008 (3 - 5 ton models) and AHRI Standard 340/360-2007 (6 and 7.5 ton models). ETL listed. CSA listed. Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. All models are ASHRAE 90.1 compliant. ISO 9001 Registered Manufacturing Quality System. WARRANTY Limited five years on compressors. Limited three years on the Lennox’ Environ™ Coil System. Limited five years Optional High Performance Economizers. Limited one year all other covered components. COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 30°F to 125°F without any additional controls. R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit is factory pre-charged with refrigerant. See Specifications Tables. B Single Speed Scroll Compressor Scroll compressors for high performance, reliability and quiet operation. Resiliently mounted on rubber grommets for quiet operation. Compressor Crankcase Heater (Furnished on KCA072 and 090 Models) Protects against refrigerant migration that can occur during low ambient operation. C Lennox’ Environ™ Coil System (Furnished on KCA072 and 090 Models) Condenser coil features lightweight, all aluminum brazed fin construction. Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tubes and two refrigerant manifolds. Environ™ Coil System Features: • I mproved heat transfer performance due to high primary surface area (flat tubes) versus secondary surface (fins). • S maller internal volume (reduced refrigerant charge). • High durability (all aluminum construction). • Fewer brazed joints. • Compact design (reduces unit weight). • Easy maintenance/cleaning. Mounting brackets with rubber inserts secure coil to unit providing vibration dampening and corrosion protection. Conventional Fin/Tube Coil (Condenser Coil for KCA036 thru 060 Models) and Evaporator Coil (all models) Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested Evaporator coil cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity. D Refrigerant Metering Orifice Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 3 FEATURES AND BENEFITS COOLING SYSTEM (continued) High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Filter/Drier High capacity filter/drier protects the system from dirt and moisture. Freezestat Protects the evaporator coil from damaging ice build-up due to conditions such as low/no air flow, or low refrigerant charge. Condensate Drain Pan Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1. Side or bottom drain connections. Reversible to allow connection at back of unit. E Outdoor Coil Fan Motor Thermal overload protected, totally enclosed, permanently lubricated sleeve bearings (036 and 048 models) or ball bearings (060, 072 and 090 models), shaft up, wire basket mount. Outdoor Coil Fan PVC coated fan guard furnished. Required Selections Cooling Capacity Specify nominal cooling capacity of the unit. Options/Accessories Field Installed Condensate Drain Trap Field installed only. Available in copper or PVC. Compressor Crankcase Heater (Optional for KCA036 thru 060 Models Only) Protects against refrigerant migration that can occur during low ambient operation. Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. Low Ambient Kit Cycles the outdoor fan while allowing compressor operation in the cooling cycle. This intermittent fan operation allows the system to operate without icing the evaporator coil and losing capacity. Designed for use in ambient temperatures no lower than 0°F. A crankcase heater must be installed on the compressor. CABINET F Construction Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have fork slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Airflow Choice Units are shipped in downflow (vertical) configuration, can be field converted to horizontal air flow configuration without the need of a kit. G Power Entry Electrical lines can be brought through the unit base or through horizontal access knock-outs. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 4 H Exterior Panels Constructed of heavy-gauge, galvanized steel with a two-layer enamel paint finish. I Insulation All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Access panels are provided for the economizer/filter section, heating/blower section, and the compressor/controls section. NOTE - KCA072/090 models include a filler panel for proper cabinet fit for optional accessories (Economizers, Power Exhaust, Outdoor Air Dampers and Barometric Relief Dampers). Options/Accessories Factory Installed Corrosion Protection A completely flexible immersed coating with an electrodeposited dry film process. (AST ElectroFin E-Coat) Meets Mil Spec MIL-P-53084, ASTM B117 Standard Method Salt Spray Testing. Indoor Corrosion Protection:Coated coil - Painted blower housing - Painted base Outdoor Corrosion Protection: - Coated coil - Painted base J Hinged Access Panels Large access panels are hinged and have quarter-turn latches for quick and easy access to maintenance areas (economizer / filter, compressor / controls, heating / blower). Field Installed Combination Coil/Hail Guards Heavy gauge steel frame painted to match cabinet with expanded metal mesh to protect the outdoor coil from damage. FEATURES AND BENEFITS CONTROLS Unit Control All control voltage is provided via a 24V (secondary) transformer with built-in circuit breaker protection. Heat/Cool Staging - Capable of up to 1 heat / 2 cool staging with a third party DDC control system or thermostat. Low Voltage Terminal Block Provides screw terminal connections for thermostat or controller wiring. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only. Options/Accessories Field Installed Commercial Control Systems L Connection® Network Complete building automation control system for single or multi-zone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See L Connection Network Product Specifications Bulletin for details. Smoke Detector Photoelectric type, installed in supply air section, return air section or both sections. Available with power board and single sensor (supply or return) or power board and two sensors (supply and return). Power board located in unit control compartment. Thermostats Control system and thermostat options, see page 34. Aftermarket unit controller options, see Options/Accessories table. K BLOWER A wide selection of supply air blower options are available to meet a variety of air flow requirements. Motor Overload protected, equipped with ball bearings (belt drive) or sleeve bearings (direct drive). Direct drive motors are offered on 036, 048 and 060 models. Single Speed belt drive motors are offered on all models and are available in several different sizes to maximize air performance. Supply Air Blower Forward curved blades, blower wheel is statically and dynamically balanced. All belt drive motors have adjustable pulley for speed change. Ordering Information Specify direct drive or belt drive motor. For belt drive, specify motor horsepower and drive kit number when base unit is ordered. Indoor Air Quality (CO2) Sensor Monitors CO2 levels adjusts economizer dampers as needed for Demand Control Ventilation ELECTRICAL Marked & Color-Coded Wiring All electrical wiring is color-coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Required Selections Voltage Choice Specify when ordering base unit. Options/Accessories Required Selections Factory or Field Installed Supply Air Blower Order one, belt drive or direct drive (See Blower Data Table for specifications). Order one drive kit, belt drive only, see Drive Kit Specifications Table. Disconnect Switch up to 150 Amp Accessible from outside of unit, spring loaded weatherproof cover furnished. Main power to the unit is field connected to the disconnect which allows all power to be shut off for service. See Electrical/ Electric Heat Data tables for ordering information, page 28. INDOOR AIR QUALITY Air Filters Disposable 2 inch filters furnished as standard. Options/Accessories Field Installed Healthy Climate® High Efficiency Air Filters Disposable MERV 8 or MERV 13 (Minimum Efficiency Reporting Value based on ASHRAE 52.2) efficiency 2 inch pleated filters. Healthy Climate® UVC Germicidal Lamps GFI Service Outlets (2) 115V ground fault circuit interrupter (GFCI) type, non-powered, fieldwired. Field Installed L Electric Heat Helix wound nichrome elements, individual element limit controls, wiring harness. Unit fuse block is furnished as standard. See Options / Accessories tables for ordering information. GFI Weatherproof Cover Single-gang cover. Heavy-duty UV-resistant polycarbonate case construction. Hinged base cover with gasket. Helps eliminate mold and bacterial growth on the evaporator and drain pans. Improves indoor air quality and maintains efficiency of system by reducing fouling of evaporator coil. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 5 OPTIONS / ACCESSORIES ECONOMIZER OPTIONS Factory or Field Installed M Economizer (Standard and High Performance Common Features) Outdoor Air Hood is furnished. Factory installed Economizer can be ordered with two exhaust options: • Barometric Relief Dampers and Exhaust Hood. • No Exhaust. Field installed Economizer includes Barometric Relief Dampers with Exhaust Hood. Barometric Relief Dampers allow relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, bird screen furnished. Occupied/Unoccupied mode with field furnished setback thermostat. Demand Control Ventilation (DCV) ready using optional CO2 sensors. Mixed Air Sensor is furnished for field installation in the rooftop unit. Sensor is factory installed when Economizers are factory installed. Single sensible sensor is furnished with Economizer and enables economizer operation if the outdoor temperature is less than the setpoint of the control. Horizontal Economizer Conversion kit is available for field installation. Standard Economizer Features (Not for Title 24) Gear-driven action, return air and outdoor air dampers, plugin connections to unit, neoprene seals, 24-volt, fully-modulating spring return motor. Standard Economizer Control Module The Standard Economizer Control Module can be adjusted to operate based on outdoor air temperatures. Economizer Controls: • D amper Minimum Position - Can be set lower than traditional minimum air requirements resulting in cost savings. • IAQ Sensor - Signals dampers to modulate and maintain 55°F when CO2 is higher than the CO2 setpoint. • Demand Control Ventilation (DCV) LED - A steady green Demand Control Ventilation LED indicates the IAQ reading is higher than setpoint and requires more fresh air. • Free Cool LED - A steady green LED indicates outdoor air is suitable for free cooling. Free Cooling runs when outdoor air temperature is lower than the set temperature on the economizer control. NOTE: The Free Cooling default setting for outdoor air temperature sensor is 55°F. High Performance Economizer Features Approved for California Title 24 building standards. ASHRAE 90.1-2010 compliant. Gear-driven action, high torque 24-volt fully-modulating spring return damper motor, return air and outdoor air dampers, plug-in connections to unit, nylon bearings, enhanced neoprene blade edge seals and flexible stainless steel jamb seals to minimize air leakage. NOTE - High Performance Economizers are not approved for use with enthalpy controls in Title 24 applications. High Performance Economizer Control Module Module provides inputs and outputs to control economizer based on parameter settings. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 6 Module automatically detects sensors by polling to determine which sensors are installed in system. Module displays any alarm messages (fault detection and diagnostics) as an aid in troubleshooting. Non-volatile memory retains parameter settings in case of power failure. Keypad with four navigation buttons and LCD screen is furnished for setting economizer parameters. • Menu Up/Exit button returns to the main menu. • A rrow Up button moves to the previous or next parameter within the selected menu. • Arrow Down button moves to the next parameter within the selected menu. • Select (enter) button confirms parameter selection. Main Menu Structure: • STATUS (economizer and system operation status) • SETPOINTS (settings for various setpoint parameters) • SYSTEM SETUP (settings/ information about the system) • ADVANCED SETUP (freeze protection, CO2 settings, stage 3 delay and additional calibration settings) • CHECKOUT (damper positions) • ALARMS (output signal that can be configured for remote alarm monitoring) NOTE - The Free Cooling setpoint for Title 24 applications must be set based on the Climate Zone where the system is installed. See Section 140.4 “Prescriptive Requirements for Space Conditioning Systems” of the California Energy Commission’s 2013 Building Energy Efficiency Standards. Refer to Installation Instructions for complete setup information and menu parameters available. OPTIONS / ACCESSORIES ECONOMIZER OPTIONS (continued) Factory or Field Installed Single Enthalpy Temperature Control (Not for Title 24) Outdoor air enthalpy sensor enables Economizer if the outdoor enthalpy is less than the setpoint of the control. Field Installed Differential Enthalpy Control (Not for Title 24) Order two Single Enthalpy Controls. One is field installed in the return air section, the other in the outdoor air section. Allows the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. Horizontal Economizer Conversion Kit Insulated panel covers the bottom return air opening on the unit base to convert downflow Economizer to horizontal airflow. EXHAUST OPTIONS Field Installed N Power Exhaust Fan Installs internal to unit for downflow applications only with Economizer option. Provides exhaust air pressure relief. Interlocked to run when supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected. Fan is 16 in. diameter with 4 fan blades and a 1/3 hp motor. NOTE - If Power Exhaust is field installed with a factory installed Economizer, the Economizer must be ordered with the “No Exhaust” option and the Barometric Relief Dampers with Exhaust Hood must also be ordered separately for field installation. OUTDOOR AIR OPTIONS Factory or Field Installed Outdoor Air Dampers Downflow or Horizontal Single blade damper, 0 to 25% (fixed) outdoor air adjustable, installs in unit. Automatic model features fully modulating spring return damper motor with plug-in connection. Manual model features a slide damper. Maximum mixed air temperature in cooling mode: 100°F. Outdoor Air Hood is furnished. ROOF CURBS Nailer strip furnished, mates to unit, US National Roofing Contractors Approved, shipped knocked down. Hybrid Roof Curbs, Downflow Roof curb can be assembled using interlocking tabs to fasten corners together. No tools required. Curb can also be fastened together with furnished hardware. Available in 8, 14, 18, and 24 inch heights. Full Perimeter Curbs, Downflow (090 Models Only) Hybrid roof curbs can be assembled using interlocking tabs to fasten corners together. No tools required. Hybrid roof curbs can also be fastened together with furnished hardware. Available in 8, 14, 18, and 24 inch heights. Adjustable Pitch Curb Fully adjustable pitch curb provides a level platform for rooftop units allowing flexible installations on roofs with uneven or sloped angles. Maximum slope is 3/4 in. per foot in any direction. Uses interlocking tabs to fasten corners together. No tools required. Hardware is furnished to connect upper curb with lower curb. Available in 14 inch height. Adaptor Curbs (not shown) Curbs are regionally sourced. Dimensions will vary based upon the source. Contact your local sales representative for a detailed cut sheet with applicable dimensions. CEILING DIFFUSERS Ceiling Diffusers (Flush and Step-Down) Diffuser face and grilles with white powder coat finish, insulated (UL listed duct liner), diffuser box with collars for duct connection, fixed blades (flush diffusers) and double deflection blades (stepdown diffusers), provisions for suspending, internally sealed (prevents recirculation), removable return air grille, adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. NOTE - 090 models can be used on smaller 79-3/4 in. Hybrid Roof Curbs (not full perimeter) with 153/4 in. overhang at condenser end of unit. See dimension drawing on page 41. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 7 OPTIONS / ACCESSORIES Unit Model No. Item Model Catalog KCA KCA KCA KCA KCA No. No. 036 048 060 072 090 COOLING SYSTEM Compressor Crankcase Heater 208/230V-1 or 3ph - K1CCHT02A-2P 14D86 208/230V-1 or 3ph - T1CCHT01AN2P 14D83 460V-3ph - K1CCHT012A-2G 14D87 460V-3ph - T1CCHT01AN2G 14D84 Condensate Drain Trap 575V-3ph - K1CCHT02A-2J 14D88 575V-3ph - T1CCHT01AN2J 14D85 PVC - C1TRAP20AD2 76W26 Copper - C1TRAP10AD2 K1SNSR71AB1K1SNSR33AN2 X X X X X X X X X X X X X X 76W27 X X X X X 74W42 X X X X X 14D89 X X X X X Standard O O O O O R-410A O O O O O Direct Drive - 0.5 hp (208/230V-1ph, 208/230V-3ph, 460V-3ph, 575V-3ph) Factory O O Direct Drive - 0.75 hp (208/230V-1ph, 208/230V-3ph, 460V-3ph, 575V-3ph) Factory Belt Drive - 1 hp (208/230V, 460V, 575V-3ph) Standard Efficiency Factory O O O O O Belt Drive - 2 hp (208/230V, 460V, 575V-3ph) Standard Efficiency Factory O O O O O Belt Drive - 3 hp (208/230V, 460V, 575V-3ph) Standard Efficiency Factory Kit A01 - T1DRKT001-1 - 673-1010 rpm Factory Drain Pan Overflow Switch Low Ambient Kit Efficiency Refrigerant Type BLOWER - SUPPLY AIR Motors Drive Kits See Blower Data Tables for selection O O O Kit A02 - T1DRKT002-1 - 745-1117 rpm Factory Kit A03 - T1DRKT003-1 - 833-1250 rpm Factory O Kit A04 - T1DRKT004-1 - 968-1340 rpm Factory Kit A05 - T1DRKT005-1 - 897-1346 rpm Factory Kit A06 - T1DRKT006-1 - 1071-1429 rpm Factory Kit A07 - T1DRKT007-1 - 1212-1548 rpm Factory Kit A08 - T1DRKT008-1 - 1193-1591 rpm Factory Kit AA01 - T1DRKT001AP1 - 522-784 rpm Factory O O O O O O O Kit AA02 - T1DRKT002AP1 - 632-875 rpm Factory O Kit AA03 - T1DRKT003AP1 - 798-1105 rpm Factory O Kit AA04 - T1DRKT004AP1 - 921-1228 rpm Factory O C1GARD51A-1 13R98 C1GARD51AT1 13T03 CABINET Combination Coil/Hail Guards K1GARD50AP1 X X X X 13T17 X Corrosion Protection Factory O O O O O Hinged Access Panels Factory O O O O O NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 8 OPTIONS / ACCESSORIES Unit Model No. Item Model Catalog KCA KCA KCA KCA KCA No. No. 036 048 060 072 090 CONTROLS Commercial Controls BACnet L Connection® Building Automation System K0CTRL31A-1 ® --- X X X 96W14 OX OX OX X X X K0CTRL31AP1 12B99 BACnet® Thermostat with Display K0SNSR01FF1 97W23 BACnet Thermostat without Display K0SNSR00FF1 97W24 X X X K0CTRL30A-1 96W11 OX OX OX K0CTRL30AP1 12B98 ® Novar® 2051 X X OX OX X X X X OX OX K0MISC00FF1 97W25 X X X X X Smoke Detector - Supply or Return (Power board and one sensor) C1SNSR44AP1 53W78 X X X X X Smoke Detector - Supply and Return (Power board and two sensors) C1SNSR43AP1 53W79 X X X X X 14D90 OX OX OX OX OX Factory O O O O O Plenum Cable (75 ft.) ECONOMIZER Standard Economizer With Outdoor Air Hood (Sensible Control) (Not for Title 24) Standard Economizer - Includes Barometric Relief Dampers and Exhaust Hood K1ECON30A-3- Standard Economizer - No Exhaust Standard Economizer Controls (Not for Title 24) Single Enthalpy Control C1SNSR64FF1 53W64 OX OX OX OX OX Differential Enthalpy Control (order 2) C1SNSR64FF1 53W64 X X X X X K1ECON32A-2 14D91 OX OX OX OX OX Single Enthalpy Control C1SNSR60FF1 10Z75 OX OX OX OX OX Differential Enthalpy Control (order 2) C1SNSR60FF1 10Z75 X X X X X T1HECK00AN1 17W45 X X X X X Motorized C1DAMP21A-1 15D17 OX OX OX OX OX Manual C1DAMP11A-2 15D18 OX OX OX OX OX 208/230V-1 or 3ph - C1PWRE10A-1P 79W87 X X X X X 460V-3ph - C1PWRE10A-1G 79W88 X X X X X 575V-3ph - C1PWRE10A-1J 79W89 X X X X X High Performance Economizer With Outdoor Air Hood (Sensible Control) (Approved for California Title 24 Building Standards) High Performance Economizer - Includes Barometric Relief Dampers and Exhaust Hood High Performance Economizer Controls (Not for Title 24) Economizer Accessories Horizontal Economizer Conversion Kit OUTDOOR AIR Outdoor Air Dampers With Outdoor Air Hood Power EXhaust FAN Standard Static NOTE - Order Barometric Relief Dampers with Exhaust Hood below if unit is ordered with factory installed Standard Economizer with “No Exhaust” option NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 9 OPTIONS / ACCESSORIES Unit Model No. Item 1 Model Catalog KCA KCA KCA KCA KCA No. No. 036 048 060 072 090 BAROMETRIC RELIEF Barometric Relief Dampers with Exhaust Hood 74W38 X X X X X 208/230V - 3 phase O O O O O 460V - 3 phase O O O O O 575V - 3 phase O O O O O C1DAMP50A-1- ELECTRICAL Voltage 60 hz Disconnect GFI Service Outlets See Electrical/Electric Heat Tables for selection OX OX OX OX OX 15 amp non-powered, field-wired (208/230V, 460V only) LTAGFIK10/15 74M70 OX OX OX OX OX 20 amp non-powered, field-wired (575V only) C1GFCI20FF1 67E01 X X X X X C1GFCI99FF1 10C89 X X X X X 208/230V-3ph - T1EH0075AN1Y 14W35 X X X X X 460V-3ph - T1EH0075AN1G 14W39 X X X X X 575V-3ph - T1EH0075AN1J 14W43 X X X X X 208/230V-3ph - T1EH0150AN1Y 14W36 X X X X X 460V-3ph - T1EH0150AN1G 14W40 X X X X X 575V-3ph - T1EH0150AN1J 14W44 X X X X X 208/230V-3ph - T1EH0225AN1Y 14W37 X X X 460V-3ph - T1EH0225AN1G 14W41 X X X 575V-3ph - T1EH0225AN1J 14W45 X X X 208/230V-3ph - T1EH0300N-1Y 14W38 X X 460V-3ph - T1EH0300N-1G 14W42 X X 575V-3ph - T1EH0300N-1J 14W46 X X MERV 8 (16 x 20 x 2) - C1FLTR15A-1- 54W20 X X X MERV 13 (16 x 20 x 2) - T1FLTR40A-1- 52W37 X X X MERV 8 (20 x 20 x 2) - C1FLTR15D-1- 54W21 X X MERV 13 (20 x 20 x 2) - C1FLTR40D-1- 52W39 X X Weatherproof Cover for GFI ELECTRIC HEAT 7.5 kW 15 kW 22.5 kW 30 kW Indoor Air Quality Air Filters Healthy Climate® High Efficiency Air Filters Order 4 per unit Indoor Air Quality (Co2) Sensors Sensor - Wall-mount, off-white plastic cover with LCD display C0SNSR50AE1L 77N39 X X X X X Sensor - Wall-mount, black plastic case, no display, rated for plenum mounting C0SNSR53AE1L 87N54 X X X X X CO2 Sensor Duct Mounting Kit - for downflow applications C0MISC19AE1- 85L43 X X X X X Aspiration Box - for duct mounting non-plenum rated CO2 sensor (77N39) C0MISC16AE1- 90N43 X X X X X E1UVCL10AN1- 50W90 X X X X X UVC Germicidal Lamps 2 Healthy Climate® UVC Light Kit (208/230v-1ph) Required when Economizer is factory installed (no exhaust option) with field installed Power Exhaust Fan option. 2 Lamps operate on 110-230V single-phase power supply. Step-down transformer may be ordered separately for 460V and 575V units. Alternately, 110V power supply may be used to directly power the UVC ballast(s). 1 NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 10 OPTIONS / ACCESSORIES Unit Model No. Item Model Catalog KCA KCA KCA KCA KCA No. No. 036 048 060 072 090 CEILING DIFFUSERS Step-Down - Order one RTD9-65S 13K60 RTD11-95S 13K61 X X X X X X X X X FD9-65S 13K55 FD11-95S 13K56 T1TRAN10AN1 17W53 T1TRAN20N-1 17W54 8 in. height C1CURB70A-1 11F50 X X X X 1 X 14 in. height C1CURB71A-1 11F51 X X X X 1 X 18 in. height C1CURB72A-1 11F52 X X X X 1 X 24 in. height C1CURB73A-1 11F53 X X X X 1 X 8 in. height K1CURB70AP1 11S47 X 14 in. height K1CURB71AP1 11S48 X 18 in. height K1CURB72AP1 11T01 X 24 in. height K1CURB73AP1 11T06 X C1CURB55AT1 43W27 Flush - Order one Transitions (Supply and Return) - Order one X X X X X X ROOF CURBS Hybrid Roof Curbs, Downflow Hybrid Roof Curbs, Full Perimeter, Downflow Adjustable Pitch Curb 14 in. height 1 X X X X 1 X 090 models will fit smaller roof curbs with overhang. See dimension drawing. NOTE - The catalog and model numbers that appear here are for ordering field installed accessories only. OX - Field Installed or Configure to Order (factory installed) O - Configure to Order (Factory Installed) X - Field Installed. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 11 SPECIFICATIONS - DIRECT DRIVE BLOWER General Data Nominal Tonnage Model No. Efficiency Type Blower Type Cooling Performance 3 - 5 TON 3 Ton 4 Ton 5 Ton KCA036S4D KCA048S4D KCA060S4D Standard Standard Standard Multi-Speed Direct Drive Multi-Speed Direct Drive Multi-Speed Direct Drive Gross Cooling Capacity - Btuh 37,500 50,000 61,800 Net Cooling Capacity - Btuh 36,000 48,000 59,000 1200 1600 1800 Sound Rating Number (SRN)((dBA) 75 75 82 Total Unit Power - kW 3.4 4.4 5.3 SEER (Btuh/Watt) 13.0 13.0 13.0 EER (Btuh/Watt) 10.7 11.0 11.2 R-410A R-410A R-410A 7 lbs. 12 oz. 8 lbs. 12 oz. 12 lbs. 8 oz. 7.5, 15 kW 7.5, 15 kW 7.5, 15, 22.5 kW Compressor Type (one per unit) Scroll Scroll Scroll Outdoor Coil 15.6 15.6 15.6 (1) 3/8 (1) 3/8 (1) 3/8 Number of rows 1 1.5 2 Fins per inch 20 20 20 Motor - (No.) HP 1/4 1/4 1/3 Motor rpm 825 825 1075 Total Motor Input - watts 250 250 370 (1) 24 - 3 (1) 24 - 3 (1) 24 - 3 Total air volume - cfm 3700 3500 4300 Net face area - sq. ft. 7.8 7.8 7.8 Tube diameter - in. 3/8 3/8 3/8 Number of rows 3 3 4 Fins per inch 14 14 14 (1) 1 NPT (1) 1 NPT (1) 1 NPT 1 AHRI Rated Air Flow - cfm 2 1 1 Refrigerant Type Charge Furnished Electric Heat Available - See page 11 Net face area - sq. ft. Tube diameter - in. Outdoor Coil Fan Diameter - (No.) in. / No. of blades Indoor Coil Drain Connection (no.) and size - in. Indoor Blower Expansion device type Refrigerant Metering Orifice (RFC) Nominal Motor HP Wheel nominal diameter x width - in. Filters 0.5 hp 0.5 hp 0.75 hp (1) 10 x 10 (1) 10 x 10 (1) 11 x 10 Type Disposable Number and size - in. Electrical Characteristics - 60 Hz (4) 16 x 20 x 2 208/230V, 460V & 575V 3 phase 208/230V, 460V & 575V 3 phase 208/230V, 460V & 575V 3 phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 AHRI Certified to AHRI Standard 210/240: 95°F outdoor air temperature and 80°F db/67°F wb entering evaporator air; minimum external duct static pressure. 2 Sound Rating Number (SRN) rated in accordance with test conditions included in ARI Standard 270-95. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 12 SPECIFICATIONS - BELT DRIVE BLOWER General Data Nominal Tonnage Model No. Efficiency Type Blower Type Cooling Performance Gross Cooling Capacity - Btuh Net Cooling Capacity - Btuh AHRI Rated Air Flow - cfm 3 Sound Rating Number (SRN) (dBA) Total Unit Power - kW SEER (Btuh/Watt) IEER (Btuh/Watt) EER (Btuh/Watt) Refrigerant Type Charge Furnished Electric Heat Available - See page 10 Compressor Type (one per unit) Outdoor Coil Net face area - sq. ft. Tube diameter - in. Number of rows Fins / inch Outdoor Motor - (No.) HP Coil Fan Motor rpm Total Motor Input - watts Diameter - (No.) in. / No. of blades Total air volume - cfm Indoor Coil Net face area - sq. ft. Tube diameter - in. Number of rows Fins per inch Drain Connection (no.) and size - in. Expansion device type 4 Indoor Nominal Motor HP Blower Maximum Usable Motor HP & Drive Available Drive Kits Selection Nominal Motor HP Maximum Usable Motor HP Available Drive Kits Wheel nominal diameter x width - in. Type Number and size - in. Electrical Characteristics - 60 Hz Filters 3 - 7.5 TON 3 Ton KCA036S4B Standard Single Speed Belt Drive 37,500 1 36,000 1200 75 3.4 1 13.0 --1 10.7 R-410A 7 lbs. 12 oz. 7.5, 15 kW Scroll 15.6 3/8 1 20 (1) 1/4 825 250 (1) 24 - 3 3700 7.8 3/8 3 14 (1) 1 NPT 4 Ton 5 Ton 6 Ton 7.5 Ton KCA048S4B KCA060S4B KCA072S4B KCA090S4B Standard Standard Standard Standard Single Speed Single Speed Single Speed Single Speed Belt Drive Belt Drive Belt Drive Belt Drive 50,000 61,800 72,500 92,000 1 1 2 48,000 59,000 69,000 90,000 1600 1800 2450 2430 75 82 79 79 4.4 5.3 6.1 8.2 1 1 13.0 13.0 ----2 2 ----12.3 11.4 1 1 2 2 11.0 11.2 11.2 11.2 R-410A R-410A R-410A R-410A 8 lbs. 12 oz. 12 lbs. 8 oz. 7 lbs. 1 oz. 8 lbs. 8 oz. 7.5, 15 kW 7.5, 15, 22.5 kW 7.5, 15, 22.5, 30 kW Scroll Scroll Scroll Scroll 15.6 15.6 17.8 24.2 3/8 3/8 ----1.5 2 1 1 20 20 23 23 (1) 1/4 (1) 1/3 (1) 1/3 (1) 1/2 825 1075 1075 1075 250 370 370 520 (1) 24 - 3 (1) 24 - 3 (1) 24 - 3 (1) 24 - 4 3500 4300 4700 5300 7.8 7.8 9.7 9.7 3/8 3/8 3/8 3/8 3 4 4 4 14 14 14 14 (1) 1 NPT (1) 1 NPT (1) 1 NPT (1) 1 NPT Refrigerant Metering Orifice (RFC) 1 hp, 2 hp 1 hp, 2 hp 1 hp, 2 hp 1 hp, 2 hp 1 hp 1.15 hp, 2.3 hp 1.15 hp, 2.3 hp 1.15 hp, 2.3 hp 1.15 hp, 2.3 hp 1.15 hp A01 A02 A03 A04 AA01 673 - 1010 rpm 745 - 1117 rpm 833 - 1250 rpm 968 - 1340 rpm 522 - 784 rpm A05 A06 A07 A08 897 - 1346 rpm 1071 - 1429 rpm 1212 - 1548 rpm 1193 - 1591 rpm --------2 hp --------2.3 hp --------AA02 632 - 875 rpm AA03 798 - 1105 rpm --------3 hp --------3.45 hp AA04 --------921 - 1228 rpm (1) 10 x 10 (1) 10 x 10 (1) 10 x 10 (1) 10 x 10 (1) 15 x 9 Disposable Disposable (4) 16 x 20 x 2 (4) 20 x 20 x 2 208/230V, 208/230V, 208/230V, 208/230V, 208/230V, 460V & 575V 460V & 575V 460V & 575V 460V & 575V 460V & 575V 3 phase 3 phase 3 phase 3 phase 3 phase NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1, 2 AHRI Certified to AHRI Standard 1 210/240 or 2 340/360: 95°F outdoor air temperature and 80°F db/67°F wb entering evaporator air; minimum external duct static pressure. 3 Sound Rating Number (SRN) rated in accordance with test conditions included in ARI Standard 270-95. 4 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished are shown. In Canada, nominal motor hp is also maximum usable motor hp output. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on the motor nameplate. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 13 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 3 TON - KCA036S4 Outdoor Air Temperature Entering Outdoor Coil Entering 85°F 95°F 105°F 115°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 960 35.6 2.35 0.75 0.87 0.98 33.4 2.67 0.75 0.89 1 31.1 3.04 0.77 0.91 1 28.5 3.48 0.79 0.93 1 63°F 1200 37.7 2.36 0.8 0.93 1 35.3 2.68 0.81 0.95 1 32.9 3.06 0.82 0.98 1 30.2 3.49 0.84 1 1 1440 39.3 2.37 0.84 0.98 1 36.8 2.69 0.85 1 1 34.5 3.07 0.87 1 1 32 3.5 0.9 1 1 960 37.6 2.36 0.59 0.72 0.84 35.4 2.68 0.59 0.73 0.86 33.1 3.05 0.59 0.74 0.88 30.4 3.5 0.59 0.76 0.9 67°F 1200 39.8 2.38 0.62 0.78 0.91 37.5 2.7 0.62 0.79 0.92 34.9 3.07 0.63 0.8 0.94 32.1 3.5 0.64 0.82 0.97 1440 41.4 2.39 0.65 0.82 0.96 38.9 2.71 0.66 0.84 0.98 36.2 3.08 0.66 0.86 1 33.3 3.51 0.68 0.88 1 960 39.9 2.38 0.45 0.58 0.7 37.5 2.7 0.44 0.58 0.71 34.9 3.07 0.42 0.58 0.72 32.2 3.5 0.43 0.58 0.74 71°F 1200 42 2.39 0.45 0.61 0.75 39.5 2.71 0.46 0.61 0.77 36.9 3.09 0.45 0.62 0.79 34 3.52 0.45 0.63 0.81 1440 43.6 2.41 0.47 0.65 0.8 41 2.73 0.46 0.65 0.82 38.2 3.1 0.47 0.66 0.83 35.2 3.53 0.47 0.68 0.87 4 TON - KCA048S4 Outdoor Air Temperature Entering Outdoor Coil Entering 85°F 95°F 105°F 115°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 1280 47.6 3.02 0.74 0.87 0.98 44.5 3.44 0.74 0.88 1 41.2 3.89 0.75 0.9 1 37.8 4.41 0.77 0.93 1 63°F 1600 50.4 3.04 0.79 0.93 1 47.1 3.46 0.8 0.95 1 43.7 3.91 0.81 0.97 1 40 4.42 0.83 1 1 1920 52.6 3.05 0.83 0.99 1 49.1 3.47 0.85 1 1 45.7 3.93 0.87 1 1 42.3 4.45 0.89 1 1 1280 50.6 3.04 0.58 0.72 0.84 47.2 3.45 0.58 0.72 0.85 43.9 3.91 0.57 0.73 0.87 40.3 4.44 0.57 0.74 0.9 67°F 1600 53.5 3.06 0.61 0.77 0.9 50 3.48 0.61 0.78 0.92 46.4 3.94 0.62 0.8 0.95 42.5 4.45 0.62 0.81 0.98 1920 55.6 3.07 0.64 0.82 0.96 51.9 3.5 0.65 0.83 0.98 47.9 3.95 0.66 0.85 1 44 4.47 0.67 0.88 1 1280 53.7 3.06 0.43 0.57 0.69 50.2 3.48 0.43 0.57 0.7 46.6 3.93 0.42 0.57 0.71 42.8 4.46 0.41 0.57 0.72 71°F 1600 56.4 3.07 0.45 0.6 0.75 52.6 3.5 0.45 0.6 0.76 49 3.96 0.44 0.61 0.78 45 4.48 0.43 0.62 0.8 1920 58.6 3.08 0.47 0.64 0.8 54.8 3.52 0.47 0.64 0.81 50.8 3.98 0.46 0.65 0.83 46.7 4.5 0.45 0.66 0.86 5 TON - KCA060S4 Outdoor Air Temperature Entering Outdoor Coil Entering 85°F 95°F 105°F 115°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 1600 60.1 3.48 0.68 0.84 1 57 3.93 0.69 0.86 1 53.5 4.44 0.71 0.89 1 50 5.04 0.73 0.93 1 63°F 2000 63.1 3.51 0.74 0.94 1 59.8 3.96 0.76 0.97 1 56 4.47 0.78 1 1 52.6 5.06 0.81 1 1 2400 65.6 3.54 0.8 1 1 62.3 3.99 0.83 1 1 59.1 4.51 0.86 1 1 55.6 5.1 0.91 1 1 1600 63.9 3.52 0.54 0.66 0.79 60.5 3.97 0.54 0.67 0.82 57.1 4.48 0.55 0.69 0.85 53.2 5.07 0.56 0.71 0.89 67°F 2000 66.8 3.55 0.57 0.72 0.9 63.1 4 0.58 0.73 0.93 59.2 4.51 0.58 0.75 0.97 55.1 5.1 0.59 0.79 1 2400 68.9 3.58 0.6 0.78 0.99 65 4.02 0.61 0.8 1 61.1 4.54 0.63 0.84 1 56.8 5.12 0.64 0.88 1 1600 67.7 3.56 0.4 0.52 0.64 64.2 4.01 0.41 0.53 0.65 60.4 4.53 0.4 0.54 0.67 56.4 5.12 0.4 0.54 0.69 71°F 2000 70.7 3.6 0.42 0.56 0.7 67 4.05 0.42 0.57 0.71 62.8 4.56 0.42 0.57 0.73 58.5 5.15 0.42 0.59 0.76 2400 72.7 3.62 0.43 0.59 0.75 68.7 4.07 0.43 0.6 0.78 64.6 4.58 0.44 0.62 0.81 60 5.17 0.44 0.64 0.85 6 TON - KCA072S4 Outdoor Air Temperature Entering Outdoor Coil Entering 85°F 95°F 105°F 115°F Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Bulb Volume Cool Motor Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Cool Motor Cool Motor Cool Motor TemperCap. Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb ature cfm kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 1920 69.7 4.27 0.74 0.89 1 64.1 4.8 0.75 0.92 1 58.7 5.43 0.77 0.95 1 53 6.14 0.79 0.99 1 63°F 2400 73.5 4.32 0.8 0.98 1 67.7 4.84 0.82 1 1 62.6 5.47 0.85 1 1 57.5 6.2 0.88 1 1 2880 77.2 4.37 0.86 1 1 71.8 4.9 0.89 1 1 66.4 5.52 0.92 1 1 60.8 6.24 0.97 1 1 1920 74.6 4.33 0.56 0.71 0.86 68.8 4.85 0.57 0.73 0.88 63.1 5.48 0.58 0.75 0.92 57.3 6.2 0.58 0.77 0.95 67°F 2400 78.3 4.39 0.61 0.78 0.95 72.2 4.9 0.62 0.8 0.98 66 5.51 0.62 0.82 1 60 6.23 0.64 0.86 1 2880 80.9 4.42 0.64 0.84 1 74.6 4.93 0.66 0.87 1 68 5.54 0.67 0.9 1 62 6.26 0.69 0.95 1 1920 79.5 4.4 0.42 0.55 0.69 73.6 4.91 0.42 0.56 0.71 67.5 5.53 0.4 0.57 0.73 61.4 6.25 0.4 0.57 0.75 71°F 2400 83.3 4.45 0.45 0.6 0.76 76.9 4.96 0.44 0.61 0.78 70.5 5.57 0.43 0.62 0.8 64.3 6.29 0.41 0.63 0.84 2880 85.8 4.5 0.46 0.64 0.82 79.4 5.01 0.45 0.66 0.86 72.5 5.6 0.45 0.67 0.88 66.1 6.32 0.45 0.68 0.93 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 14 RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 7.5 TON - KCA090S4 Entering Total Wet Air Bulb Volume Temperature cfm 2400 63°F 3000 3600 2400 67°F 3000 3600 2400 71°F 3000 3600 Total Cool Cap. kBtuh 92.4 97.7 101.9 99.4 104.5 108.5 106.2 111.7 115.6 Outdoor Air Temperature Entering Outdoor Coil 85°F 95°F 105°F 115°F Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Total Comp. Sensible To Total Ratio (S/T) Ratio (S/T) Ratio (S/T) Ratio (S/T) Motor Cool Motor Cool Motor Cool Motor Input Cap. Input Cap. Input Cap. Input Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F kBtuh kW 75°F 80°F 85°F 5.97 0.69 0.84 0.98 85.3 6.6 0.7 0.86 1 77.8 7.32 0.7 0.88 1 69.9 8.15 0.71 0.91 1 6.04 0.75 0.92 1 90.2 6.68 0.76 0.95 1 82.5 7.4 0.78 0.98 1 74.5 8.23 0.81 1 1 6.11 0.81 1 1 94.6 6.75 0.83 1 1 87.2 7.48 0.85 1 1 79.5 8.33 0.89 1 1 6.07 0.54 0.67 0.81 91.8 6.7 0.53 0.68 0.83 84.2 7.43 0.53 0.68 0.85 75.9 8.26 0.52 0.7 0.88 6.15 0.57 0.73 0.89 96.8 6.78 0.58 0.74 0.91 88.7 7.51 0.57 0.76 0.95 79.9 8.34 0.58 0.79 0.99 6.21 0.61 0.79 0.97 100.2 6.84 0.62 0.81 0.99 92 7.57 0.62 0.84 1 82.7 8.39 0.62 0.87 1 6.17 0.4 0.53 0.65 98.5 6.81 0.38 0.52 0.66 90.6 7.54 0.37 0.52 0.67 82.2 8.38 0.36 0.52 0.68 6.26 0.41 0.57 0.71 103.8 6.9 0.4 0.57 0.72 95.1 7.63 0.4 0.57 0.74 86.3 8.46 0.38 0.58 0.77 6.33 0.44 0.6 0.77 107.2 6.96 0.43 0.61 0.79 98.6 7.69 0.42 0.62 0.82 89 8.51 0.41 0.63 0.85 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 15 BLOWER DATA - DIRECT DRIVE - KCA036, KCA048 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. External Static Pressure (in. w.g.) Air Volume (cfm) at Various Blower Speeds 208 VOLTS High Medium 230 VOLTS Low High Medium 460/575 VOLTS Low High 3 and 4 Ton Standard Efficiency (Downflow) Medium Low KCA036S and KCA048S 0.0 1938 1552 1119 2167 1772 1317 2136 1716 1212 0.1 1992 1586 1128 2167 1780 1315 2104 1728 1208 0.2 1915 1592 1137 2100 1792 1307 2052 1684 1197 0.3 1865 1536 1083 2043 1735 1266 1994 1647 1172 0.4 1813 1495 1033 1986 1678 1204 1918 1597 1134 0.5 1762 1444 976 1909 1621 1164 1861 1534 1096 0.6 1694 1391 899 1814 1535 1082 1765 1485 1059 0.7 1609 1331 817 1718 1478 1000 1689 1410 996 0.8 1471 1220 730 1603 1364 918 1613 1335 920 0.9 1368 1066 522 1488 1250 755 1498 1235 848 1.0 1108 869 402 1259 1021 640 1345 1036 763 3 and 4 Ton Standard Efficiency (Horizontal) KCA036S and KCA048S 0.0 1862 1520 1070 2082 1736 1259 2085 1745 1247 0.1 1867 1530 1069 2031 1717 1246 2070 1744 1257 0.2 1804 1485 1067 1978 1672 1227 2016 1690 1225 0.3 1741 1440 1018 1907 1627 1190 1944 1643 1192 0.4 1677 1396 968 1837 1567 1128 1890 1596 1160 0.5 1614 1329 894 1749 1492 1066 1800 1533 1111 0.6 1550 1284 844 1660 1417 1016 1727 1455 1062 0.7 1455 1195 769 1554 1327 941 1655 1377 996 0.8 1329 1106 670 1448 1237 842 1511 1283 865 0.9 1202 927 496 1307 1087 718 1403 1190 784 1.0 1012 828 385 1025 973 613 1222 1002 670 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 16 BLOWER DATA - DIRECT DRIVE - KCA060 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. External Static Pressure (in. w.g.) Air Volume (cfm) at Various Blower Speeds 208 VOLTS High 230 VOLTS Low High 460/575 VOLTS Low High 5 Ton Standard Efficiency (Downflow) Low KCA060S 0.0 2121 1644 2324 1952 2160 1750 0.1 2162 1660 2315 1991 2128 1733 0.2 2100 1704 2285 1946 2092 1712 0.3 2078 1667 2230 1928 2054 1687 0.4 2056 1646 2185 1909 2005 1652 0.5 2014 1626 2154 1873 1972 1629 0.6 1953 1592 2049 1821 1907 1583 0.7 1913 1594 1966 1787 1858 1549 0.8 1830 1519 1936 1715 1810 1515 0.9 1774 1509 1763 1650 1744 1469 1.0 1601 1319 1649 1508 1679 1400 5 Ton Standard Efficiency (Horizontal) KCA060S 0.0 2038 1611 2222 1875 2225 1885 0.1 2026 1601 2194 1866 2236 1895 0.2 1978 1590 2145 1833 2186 1853 0.3 1940 1563 2096 1800 2137 1818 0.4 1902 1537 2047 1766 2106 1799 0.5 1845 1497 1973 1716 2031 1763 0.6 1787 1470 1924 1666 2002 1711 0.7 1730 1431 1850 1616 1970 1677 0.8 1653 1378 1776 1549 1853 1607 0.9 1558 1312 1677 1449 1800 1586 1.0 1462 1257 1579 1377 1750 1418 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 17 BLOWER DATA - BELT DRIVE - KCA036 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 486 0.12 554 0.16 623 0.20 695 0.22 767 0.23 836 0.25 897 0.28 953 0.30 1000 508 0.15 576 0.19 643 0.22 713 0.24 783 0.26 848 0.28 907 0.30 961 0.33 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 1100 533 0.18 599 0.22 665 0.25 733 0.27 800 0.28 863 0.31 919 0.34 971 0.36 1200 560 0.21 625 0.25 689 0.28 755 0.30 820 0.32 879 0.34 932 0.37 983 0.40 1300 591 0.24 654 0.28 716 0.31 779 0.33 841 0.35 897 0.38 948 0.41 996 0.44 1400 631 0.26 690 0.30 748 0.34 807 0.36 864 0.39 916 0.42 964 0.46 1011 0.49 1500 676 0.28 729 0.33 782 0.36 835 0.40 887 0.43 935 0.47 981 0.50 1028 0.54 External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 1004 0.33 1055 0.35 1106 0.37 1152 0.40 1193 0.43 1232 0.46 1269 0.49 1305 0.52 1000 1011 0.36 1062 0.38 1111 0.41 1157 0.43 1199 0.47 1238 0.50 1276 0.53 1311 0.56 1100 1020 0.39 1070 0.41 1118 0.44 1163 0.47 1206 0.51 1245 0.54 1282 0.58 1318 0.61 1200 1031 0.43 1079 0.45 1127 0.48 1171 0.52 1213 0.55 1252 0.59 1289 0.62 1324 0.66 1300 1044 0.47 1091 0.49 1137 0.53 1181 0.56 1221 0.60 1259 0.64 1296 0.68 1330 0.71 1400 1058 0.51 1105 0.54 1150 0.57 1191 0.61 1231 0.65 1268 0.69 1303 0.73 1337 0.77 1500 1074 0.56 1120 0.59 1163 0.63 1203 0.67 1241 0.71 1277 0.75 1312 0.79 1345 0.82 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 HORIZONTAL External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 900 485 0.11 554 0.14 627 0.16 703 0.18 780 0.21 841 0.23 888 0.27 935 0.30 1000 509 0.13 578 0.16 649 0.19 722 0.21 796 0.23 854 0.26 900 0.29 947 0.33 1100 537 0.16 605 0.19 674 0.21 744 0.24 813 0.26 868 0.29 913 0.33 959 0.36 1200 567 0.19 633 0.22 700 0.24 768 0.27 833 0.30 884 0.33 928 0.37 974 0.40 1300 599 0.22 664 0.25 729 0.28 793 0.30 853 0.33 902 0.37 945 0.41 990 0.44 1400 634 0.26 697 0.29 758 0.31 819 0.34 875 0.38 921 0.42 964 0.46 1008 0.49 1500 669 0.30 730 0.33 789 0.36 846 0.39 897 0.42 941 0.47 983 0.51 1028 0.54 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 900 986 0.32 1039 0.35 1090 0.37 1137 0.40 1177 0.43 1214 0.46 1248 0.49 1280 0.51 1000 997 0.35 1048 0.38 1098 0.41 1143 0.44 1184 0.47 1221 0.50 1255 0.53 1287 0.56 1100 1008 0.39 1059 0.41 1107 0.44 1150 0.47 1191 0.51 1228 0.54 1263 0.57 1295 0.60 1200 1022 0.43 1071 0.45 1117 0.48 1160 0.52 1200 0.55 1237 0.59 1271 0.62 1303 0.66 1300 1037 0.47 1085 0.50 1130 0.53 1171 0.57 1210 0.60 1246 0.64 1280 0.68 1312 0.71 1400 1054 0.52 1100 0.54 1144 0.58 1183 0.62 1221 0.66 1256 0.70 1290 0.73 1321 0.77 1500 1073 0.57 1117 0.60 1159 0.64 1197 0.67 1234 0.71 1268 0.75 1301 0.79 1332 0.83 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 18 BLOWER DATA - BELT DRIVE - KCA048 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume cfm 0.10 RPM BHP 560 0.21 591 0.24 631 0.26 675 0.28 718 0.31 756 0.34 787 0.40 815 0.46 843 0.53 0.20 RPM BHP 625 0.25 654 0.28 690 0.30 729 0.33 766 0.35 799 0.39 828 0.45 855 0.51 884 0.59 0.30 RPM BHP 689 0.28 716 0.31 748 0.34 782 0.36 814 0.40 843 0.44 870 0.50 897 0.57 925 0.64 0.90 RPM BHP 1200 1031 0.43 1300 1044 0.47 1400 1058 0.51 1500 1074 0.56 1600 1092 0.61 1700 1112 0.67 1800 1133 0.73 1900 1156 0.80 2000 1178 0.87 HORIZONTAL 1.00 RPM BHP 1079 0.45 1091 0.49 1105 0.54 1120 0.59 1137 0.65 1155 0.70 1174 0.77 1193 0.84 1213 0.92 1.10 RPM BHP 1127 0.48 1137 0.53 1150 0.57 1163 0.63 1178 0.68 1193 0.75 1209 0.81 1226 0.89 1243 0.97 0.10 RPM BHP 567 0.19 599 0.22 634 0.26 669 0.30 705 0.34 741 0.38 776 0.43 812 0.48 847 0.54 0.20 RPM BHP 633 0.22 664 0.25 697 0.29 730 0.33 763 0.37 796 0.41 829 0.46 862 0.52 895 0.59 0.30 RPM BHP 700 0.24 729 0.28 758 0.31 789 0.36 819 0.40 850 0.45 880 0.51 910 0.57 941 0.64 0.90 RPM BHP 1022 0.43 1037 0.47 1054 0.52 1073 0.57 1093 0.62 1114 0.68 1136 0.75 1159 0.82 1183 0.90 1.00 RPM BHP 1071 0.45 1085 0.50 1100 0.54 1117 0.60 1136 0.66 1155 0.72 1175 0.79 1197 0.86 1218 0.95 1.10 RPM BHP 1117 0.48 1130 0.53 1144 0.58 1159 0.64 1175 0.70 1192 0.76 1210 0.83 1229 0.92 1249 1.01 1200 1300 1400 1500 1600 1700 1800 1900 2000 Air Volume cfm Air Volume cfm 1200 1300 1400 1500 1600 1700 1800 1900 2000 Air Volume cfm 1200 1300 1400 1500 1600 1700 1800 1900 2000 External Static - in. w.g. 0.40 0.50 RPM BHP RPM BHP 755 0.30 820 0.32 779 0.33 841 0.35 807 0.36 864 0.39 835 0.40 887 0.43 862 0.44 910 0.48 887 0.49 932 0.53 912 0.55 955 0.59 939 0.62 981 0.66 968 0.68 1009 0.72 External Static - in. w.g. 1.20 1.30 RPM BHP RPM BHP 1171 0.52 1213 0.55 1181 0.56 1221 0.60 1191 0.61 1231 0.65 1203 0.67 1241 0.71 1216 0.72 1253 0.76 1230 0.79 1265 0.83 1244 0.85 1278 0.90 1260 0.93 1293 0.97 1275 1.02 1307 1.06 External Static - in. w.g. 0.40 0.50 RPM BHP RPM BHP 768 0.27 833 0.30 793 0.30 853 0.33 819 0.34 875 0.38 846 0.39 897 0.42 873 0.43 921 0.48 900 0.49 945 0.53 927 0.55 970 0.60 955 0.62 996 0.66 984 0.69 1023 0.74 External Static - in. w.g. 1.20 1.30 RPM BHP RPM BHP 1160 0.52 1200 0.55 1171 0.57 1210 0.60 1183 0.62 1221 0.66 1197 0.67 1234 0.71 1212 0.74 1247 0.78 1227 0.80 1262 0.85 1245 0.88 1278 0.92 1263 0.97 1296 1.01 1282 1.06 1314 1.11 0.60 RPM BHP 879 0.34 897 0.38 916 0.42 935 0.47 955 0.52 976 0.57 999 0.63 1024 0.69 1052 0.76 0.70 RPM BHP 932 0.37 948 0.41 964 0.46 981 0.50 1000 0.55 1020 0.61 1043 0.67 1068 0.73 1095 0.79 0.80 RPM BHP 983 0.40 996 0.44 1011 0.49 1028 0.54 1046 0.59 1066 0.64 1089 0.70 1113 0.76 1138 0.83 1.40 RPM BHP 1252 0.59 1259 0.64 1268 0.69 1277 0.75 1288 0.80 1299 0.87 1311 0.94 1325 1.01 1339 1.10 1.50 RPM BHP 1289 0.62 1296 0.68 1303 0.73 1312 0.79 1321 0.84 1332 0.91 1343 0.98 1356 1.06 1370 1.14 1.60 RPM BHP 1324 0.66 1330 0.71 1337 0.77 1345 0.82 1354 0.88 1364 0.95 1375 1.02 1388 1.10 1402 1.18 0.60 RPM BHP 884 0.33 902 0.37 921 0.42 941 0.47 963 0.52 985 0.58 1009 0.64 1035 0.71 1062 0.78 0.70 RPM BHP 928 0.37 945 0.41 964 0.46 983 0.51 1004 0.56 1026 0.62 1050 0.68 1076 0.74 1103 0.81 0.80 RPM BHP 974 0.40 990 0.44 1008 0.49 1028 0.54 1048 0.59 1070 0.65 1093 0.71 1118 0.78 1144 0.85 1.40 RPM BHP 1237 0.59 1246 0.64 1256 0.70 1268 0.75 1281 0.82 1295 0.89 1311 0.97 1328 1.06 1346 1.15 1.50 RPM BHP 1271 0.62 1280 0.68 1290 0.73 1301 0.79 1313 0.86 1327 0.93 1342 1.01 1359 1.10 1377 1.20 1.60 RPM BHP 1303 0.66 1312 0.71 1321 0.77 1332 0.83 1344 0.90 1358 0.97 1373 1.05 1390 1.14 1408 1.24 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 19 BLOWER DATA - BELT DRIVE - KCA060 BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. DOWNFLOW Air Volume 0.10 cfm RPM BHP 1600 738 0.32 1700 773 0.36 1800 803 0.42 1900 831 0.48 2000 861 0.56 2100 893 0.63 2200 927 0.71 963 0.79 2300 999 0.88 2400 Air Volume 0.90 cfm RPM BHP 1600 1107 0.62 1700 1128 0.68 1800 1150 0.74 1900 1173 0.81 2000 1195 0.89 2100 1217 0.98 1238 1.08 2200 2300 1257 1.19 2400 1278 1.30 HORIZONTAL Air Volume 0.10 cfm RPM BHP 1600 752 0.30 1700 785 0.35 1800 813 0.42 1900 841 0.49 2000 871 0.56 2100 903 0.64 2200 937 0.73 2300 973 0.81 2400 1010 0.91 Air Volume 0.90 cfm RPM BHP 1600 1107 0.63 1700 1129 0.69 1800 1152 0.76 1900 1176 0.83 2000 1201 0.92 2100 1225 1.02 2200 1249 1.13 2300 1273 1.25 2400 1300 1.37 0.20 RPM BHP 785 0.36 816 0.41 844 0.47 872 0.54 903 0.61 935 0.69 969 0.76 1004 0.84 1039 0.92 0.30 RPM BHP 831 0.41 859 0.46 886 0.52 915 0.59 945 0.66 978 0.73 1011 0.81 1045 0.89 1078 0.97 1.00 RPM BHP 1151 0.66 1169 0.72 1189 0.79 1208 0.86 1228 0.94 1247 1.04 1265 1.14 1284 1.25 1305 1.36 1.10 RPM BHP 1190 0.70 1206 0.76 1223 0.83 1240 0.91 1257 0.99 1275 1.09 1293 1.19 1313 1.30 1334 1.40 0.20 RPM BHP 798 0.35 827 0.40 855 0.47 883 0.54 914 0.62 946 0.70 981 0.78 1015 0.86 1051 0.96 0.30 RPM BHP 844 0.40 871 0.46 898 0.52 926 0.60 957 0.67 990 0.75 1023 0.83 1056 0.91 1090 1.01 1.00 RPM BHP 1149 0.67 1169 0.73 1190 0.80 1212 0.89 1234 0.98 1256 1.08 1279 1.19 1303 1.31 1329 1.43 1.10 RPM BHP 1187 0.71 1204 0.78 1223 0.85 1243 0.94 1264 1.04 1285 1.14 1308 1.25 1332 1.36 1359 1.47 External Static - in. w.g. 0.40 0.50 RPM BHP RPM BHP 878 0.45 923 0.49 903 0.51 947 0.55 929 0.57 972 0.61 957 0.63 1000 0.67 988 0.70 1030 0.74 1019 0.78 1060 0.81 1052 0.85 1091 0.89 1084 0.93 1122 0.97 1115 1.02 1151 1.06 External Static - in. w.g. 1.20 1.30 RPM BHP RPM BHP 1228 0.74 1264 0.78 1242 0.80 1277 0.84 1257 0.87 1291 0.91 1273 0.95 1306 0.99 1290 1.04 1321 1.08 1306 1.14 1338 1.18 1324 1.24 1355 1.28 1344 1.34 1375 1.38 1364 1.44 1395 1.48 External Static - in. w.g. 0.40 0.50 RPM BHP RPM BHP 889 0.45 933 0.49 914 0.51 957 0.55 940 0.57 983 0.62 969 0.65 1011 0.69 1000 0.72 1040 0.76 1031 0.79 1071 0.83 1063 0.87 1102 0.91 1095 0.96 1132 1.01 1127 1.06 1164 1.11 External Static - in. w.g. 1.20 1.30 RPM BHP RPM BHP 1223 0.75 1258 0.79 1240 0.82 1274 0.86 1258 0.90 1291 0.94 1277 0.99 1309 1.03 1296 1.09 1329 1.13 1318 1.19 1349 1.24 1340 1.30 1372 1.34 1364 1.41 1396 1.45 1390 1.52 1422 1.56 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 20 0.60 RPM BHP 969 0.53 991 0.58 1016 0.64 1043 0.71 1072 0.77 1101 0.85 1131 0.93 1159 1.02 1186 1.12 0.70 RPM BHP 1014 0.57 1036 0.62 1060 0.68 1087 0.74 1115 0.81 1143 0.89 1170 0.97 1195 1.07 1219 1.18 0.80 RPM BHP 1061 0.59 1082 0.65 1106 0.71 1131 0.78 1157 0.85 1182 0.93 1206 1.02 1228 1.13 1250 1.24 1.40 RPM BHP 1298 0.82 1310 0.88 1324 0.95 1338 1.03 1353 1.12 1369 1.22 1387 1.31 1406 1.41 1427 1.51 1.50 RPM BHP 1332 0.86 1343 0.92 1356 0.99 1369 1.07 1384 1.16 1400 1.25 1418 1.35 1437 1.45 1458 1.55 1.60 RPM BHP 1364 0.90 1375 0.96 1388 1.03 1401 1.12 1416 1.20 1432 1.29 1450 1.39 1470 1.48 1492 1.58 0.60 RPM BHP 975 0.53 999 0.59 1025 0.66 1052 0.72 1081 0.79 1110 0.87 1140 0.96 1170 1.06 1200 1.18 0.70 RPM BHP 1018 0.57 1042 0.63 1067 0.69 1094 0.76 1122 0.83 1150 0.91 1178 1.01 1206 1.12 1235 1.24 0.80 RPM BHP 1062 0.60 1085 0.66 1110 0.72 1136 0.79 1162 0.87 1189 0.96 1215 1.07 1242 1.19 1269 1.31 1.40 RPM BHP 1291 0.83 1306 0.90 1323 0.99 1341 1.08 1360 1.18 1381 1.28 1403 1.38 1427 1.49 1453 1.60 1.50 RPM BHP 1323 0.87 1338 0.95 1354 1.03 1372 1.12 1391 1.22 1412 1.32 1434 1.42 1458 1.53 1484 1.64 1.60 RPM BHP 1354 0.91 1369 0.99 1385 1.07 1402 1.16 1422 1.26 1442 1.36 1465 1.46 1490 1.57 1516 1.67 BLOWER DATA - BELT DRIVE - KCA072 - DOWNFLOW BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 826 0.36 859 0.41 894 0.45 928 0.50 964 0.56 1000 0.61 1036 0.66 1072 0.70 2000 857 0.42 889 0.47 920 0.52 952 0.57 986 0.62 1020 0.68 1055 0.73 1091 0.77 2100 878 0.49 909 0.54 940 0.59 973 0.64 1006 0.70 1041 0.75 1076 0.80 1112 0.85 2200 897 0.55 929 0.61 961 0.66 994 0.72 1028 0.78 1063 0.83 1099 0.89 1134 0.93 2300 918 0.62 950 0.68 983 0.74 1017 0.80 1052 0.86 1087 0.92 1122 0.97 1157 1.02 2400 941 0.70 974 0.77 1008 0.83 1042 0.90 1077 0.96 1111 1.01 1146 1.06 1181 1.11 2500 966 0.79 1000 0.86 1034 0.93 1068 1.00 1103 1.06 1137 1.11 1171 1.16 1205 1.20 2600 994 0.90 1028 0.97 1062 1.04 1096 1.10 1130 1.16 1164 1.21 1197 1.26 1231 1.30 2700 1023 1.01 1057 1.08 1091 1.15 1125 1.22 1159 1.27 1192 1.32 1225 1.37 1258 1.41 2800 1053 1.13 1088 1.21 1122 1.27 1155 1.33 1188 1.39 1221 1.43 1253 1.48 1286 1.53 2900 1085 1.26 1119 1.33 1153 1.40 1186 1.45 1218 1.51 1250 1.55 1281 1.61 1313 1.66 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 1109 0.75 1146 0.79 1183 0.82 1221 0.86 1260 0.90 1294 0.94 1323 0.98 1349 1.02 2000 1128 0.82 1164 0.86 1201 0.89 1239 0.93 1276 0.97 1310 1.01 1336 1.06 1362 1.10 2100 1148 0.89 1185 0.93 1221 0.97 1258 1.01 1294 1.05 1325 1.09 1351 1.14 1376 1.19 2200 1170 0.97 1206 1.01 1242 1.05 1277 1.09 1311 1.14 1341 1.18 1365 1.23 1390 1.28 2300 1193 1.06 1228 1.09 1262 1.14 1295 1.19 1327 1.24 1355 1.29 1380 1.33 1406 1.37 2400 1216 1.15 1250 1.19 1282 1.24 1313 1.30 1343 1.36 1371 1.40 1396 1.44 1423 1.48 2500 1240 1.24 1273 1.29 1302 1.36 1331 1.42 1360 1.48 1388 1.52 1414 1.55 1441 1.58 2600 1265 1.34 1296 1.40 1324 1.47 1352 1.54 1381 1.60 1408 1.64 1434 1.67 1460 1.70 2700 1291 1.46 1321 1.52 1347 1.60 1374 1.67 1403 1.72 1429 1.76 1455 1.79 1481 1.82 2800 1317 1.58 1346 1.66 1372 1.74 1399 1.80 1426 1.85 1451 1.89 1477 1.92 1503 1.95 2900 1343 1.72 1371 1.80 1397 1.88 1424 1.95 1450 1.99 1475 2.02 1500 2.05 1526 2.08 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 21 BLOWER DATA - BELT DRIVE - KCA072 - HORIZONTAL BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) See page 26. 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26. See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 853 0.41 886 0.46 919 0.50 952 0.55 986 0.60 1021 0.64 1056 0.69 1091 0.73 2000 883 0.48 913 0.53 944 0.57 976 0.62 1009 0.67 1043 0.71 1078 0.76 1112 0.80 2100 906 0.56 936 0.60 967 0.65 999 0.70 1033 0.75 1067 0.79 1101 0.84 1135 0.88 2200 930 0.64 960 0.68 991 0.73 1024 0.78 1058 0.83 1092 0.88 1126 0.92 1160 0.96 2300 954 0.72 985 0.77 1017 0.82 1051 0.87 1085 0.92 1119 0.96 1152 1.00 1186 1.04 2400 981 0.81 1013 0.86 1046 0.91 1079 0.96 1113 1.00 1146 1.05 1180 1.09 1213 1.13 2500 1010 0.91 1042 0.96 1075 1.00 1109 1.05 1142 1.09 1175 1.14 1207 1.18 1239 1.23 2600 1040 1.01 1073 1.05 1106 1.10 1139 1.14 1171 1.19 1203 1.23 1235 1.28 1266 1.33 2700 1072 1.10 1104 1.15 1137 1.20 1169 1.24 1201 1.29 1232 1.34 1263 1.40 1293 1.46 2800 1105 1.21 1137 1.25 1168 1.30 1200 1.35 1231 1.40 1261 1.46 1291 1.52 1321 1.59 2900 1138 1.32 1169 1.37 1200 1.42 1231 1.47 1261 1.53 1291 1.60 1321 1.66 1350 1.73 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 External Static - in. w.g. Air Volume cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1900 1126 0.77 1163 0.81 1200 0.85 1237 0.88 1273 0.92 1306 0.96 1339 1.00 1371 1.04 2000 1148 0.84 1183 0.88 1220 0.92 1257 0.96 1291 1.00 1323 1.04 1354 1.08 1385 1.12 2100 1170 0.92 1206 0.96 1242 1.00 1277 1.04 1310 1.08 1340 1.13 1371 1.17 1401 1.21 2200 1195 1.00 1230 1.04 1265 1.08 1299 1.13 1330 1.18 1359 1.23 1388 1.27 1418 1.31 2300 1220 1.08 1254 1.13 1288 1.17 1320 1.23 1350 1.28 1378 1.34 1406 1.38 1435 1.42 2400 1245 1.18 1278 1.22 1311 1.28 1341 1.33 1370 1.40 1397 1.45 1425 1.50 1454 1.54 2500 1271 1.28 1303 1.33 1334 1.39 1363 1.45 1391 1.52 1418 1.57 1446 1.62 1474 1.66 2600 1297 1.39 1328 1.45 1357 1.52 1385 1.58 1412 1.64 1439 1.70 1467 1.74 1495 1.78 2700 1323 1.52 1353 1.58 1382 1.65 1409 1.72 1435 1.77 1462 1.82 1490 1.86 1517 1.90 2800 1351 1.65 1380 1.72 1407 1.78 1434 1.85 1460 1.90 1486 1.95 1513 1.99 1541 2.02 2900 1379 1.79 1407 1.86 1434 1.92 1460 1.98 1485 2.04 1511 2.08 1538 2.12 1565 2.15 0.90 1.00 1.10 1.20 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 22 1.30 1.40 1.50 1.60 BLOWER DATA - BELT DRIVE - KCA090 - DOWNFLOW BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. External Static - in. w.g. Air Volume 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2400 553 0.65 585 0.71 617 0.78 649 0.85 680 0.91 711 0.98 740 1.04 769 1.10 796 1.15 821 1.21 2500 570 0.71 602 0.78 633 0.84 665 0.91 695 0.97 725 1.04 753 1.10 781 1.16 807 1.22 832 1.27 2600 588 0.77 619 0.84 650 0.91 680 0.97 710 1.04 739 1.10 767 1.16 793 1.22 818 1.28 842 1.33 2700 607 0.84 637 0.91 667 0.97 697 1.04 726 1.11 753 1.17 780 1.23 806 1.29 830 1.35 854 1.40 2800 626 0.91 655 0.97 684 1.04 713 1.11 741 1.18 768 1.24 794 1.30 819 1.36 842 1.42 866 1.47 2900 646 0.98 674 1.05 702 1.11 730 1.18 757 1.25 783 1.32 808 1.38 832 1.44 855 1.49 878 1.54 3000 666 1.06 693 1.12 721 1.19 747 1.26 774 1.33 799 1.40 823 1.46 846 1.52 868 1.57 891 1.62 3100 686 1.14 713 1.21 739 1.28 765 1.35 790 1.41 814 1.48 838 1.55 860 1.61 882 1.66 904 1.70 3200 707 1.22 732 1.29 758 1.36 783 1.43 807 1.50 830 1.57 853 1.64 874 1.70 896 1.75 918 1.79 3300 727 1.31 752 1.38 776 1.46 800 1.53 823 1.60 846 1.67 868 1.73 889 1.79 911 1.84 932 1.89 3400 747 1.41 771 1.48 794 1.55 817 1.63 840 1.70 862 1.77 883 1.83 904 1.89 925 1.94 947 1.98 3500 767 1.51 790 1.58 812 1.66 835 1.73 856 1.80 878 1.87 899 1.93 920 1.99 940 2.04 961 2.08 3600 786 1.61 808 1.69 830 1.77 852 1.84 873 1.91 894 1.98 915 2.04 935 2.09 955 2.14 975 2.19 External Static - in. w.g. Air Volume 0.90 1.00 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2400 846 1.25 870 1.29 895 1.33 920 1.37 947 1.41 972 1.45 996 1.50 1018 1.55 1039 1.61 1059 1.67 2500 856 1.31 880 1.35 905 1.39 930 1.43 956 1.47 980 1.52 1003 1.57 1024 1.63 1044 1.69 1064 1.76 2600 866 1.38 891 1.42 915 1.46 940 1.50 965 1.54 988 1.59 1010 1.65 1031 1.71 1050 1.78 1069 1.84 2700 878 1.44 902 1.48 926 1.52 950 1.57 974 1.61 997 1.67 1018 1.73 1037 1.80 1056 1.87 1075 1.93 2800 889 1.51 913 1.55 937 1.59 961 1.64 984 1.69 1006 1.75 1026 1.82 1044 1.89 1063 1.96 1081 2.03 2900 902 1.58 925 1.63 949 1.67 972 1.72 994 1.78 1015 1.84 1034 1.91 1052 1.99 1069 2.06 1087 2.13 3000 914 1.66 938 1.71 961 1.75 983 1.81 1004 1.87 1024 1.94 1042 2.01 1059 2.09 1076 2.16 1093 2.23 3100 927 1.75 950 1.79 972 1.84 994 1.90 1014 1.96 1033 2.04 1050 2.11 1067 2.19 1083 2.27 1100 2.34 3200 941 1.84 963 1.88 984 1.94 1005 2.00 1024 2.07 1042 2.14 1059 2.23 1075 2.31 1091 2.39 1107 2.46 3300 954 1.93 976 1.98 996 2.04 1016 2.10 1035 2.18 1052 2.26 1067 2.35 1083 2.43 1098 2.51 1114 2.59 3400 968 2.03 989 2.08 1008 2.14 1027 2.22 1045 2.30 1061 2.38 1076 2.47 1091 2.57 1106 2.65 1121 2.73 3500 982 2.13 1001 2.19 1020 2.26 1038 2.33 1054 2.42 1070 2.51 1084 2.61 1099 2.71 1113 2.79 1128 2.87 3600 995 2.24 1014 2.30 1031 2.38 1048 2.46 1064 2.55 1079 2.65 1093 2.76 1107 2.86 1121 2.95 1136 3.03 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 23 BLOWER DATA - BELT DRIVE - KCA090 - HORIZONTAL BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL AND AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 - Any factory installed options air resistance (economizer, wet coil, etc.) 2 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.) See page 26 for blower motors and drives and wet coil and options/accessory air resistance data. External Static - in. w.g. Air Volume 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2400 596 0.79 626 0.82 657 0.85 688 0.89 718 0.92 749 0.96 778 1.01 806 1.06 833 1.11 858 1.16 2500 616 0.85 645 0.88 676 0.91 706 0.95 736 0.99 765 1.03 794 1.08 821 1.13 847 1.18 871 1.23 2600 636 0.91 665 0.94 695 0.98 724 1.02 754 1.06 782 1.10 809 1.15 836 1.20 861 1.25 885 1.30 2700 657 0.97 685 1.01 714 1.04 743 1.08 771 1.13 799 1.17 826 1.22 851 1.27 875 1.32 899 1.37 2800 677 1.03 706 1.07 734 1.11 762 1.16 790 1.20 816 1.25 842 1.30 867 1.35 890 1.40 913 1.45 2900 698 1.10 726 1.14 754 1.19 781 1.23 808 1.28 834 1.33 859 1.38 883 1.43 906 1.48 928 1.54 3000 720 1.17 747 1.22 774 1.26 801 1.31 826 1.36 851 1.41 876 1.46 899 1.52 921 1.57 943 1.63 3100 741 1.25 768 1.30 794 1.35 820 1.40 845 1.45 869 1.50 893 1.56 915 1.61 937 1.67 959 1.73 3200 763 1.34 789 1.39 815 1.44 840 1.49 864 1.54 888 1.60 910 1.66 932 1.72 954 1.78 975 1.84 3300 785 1.43 811 1.48 836 1.53 860 1.59 883 1.65 906 1.71 928 1.77 950 1.83 970 1.90 991 1.96 3400 807 1.53 832 1.58 856 1.64 880 1.70 903 1.76 925 1.82 946 1.88 967 1.95 987 2.02 1007 2.09 3500 830 1.63 854 1.69 877 1.75 900 1.81 922 1.88 944 1.94 964 2.01 985 2.08 1004 2.15 1024 2.23 3600 852 1.74 876 1.81 898 1.87 921 1.94 942 2.01 963 2.07 983 2.15 1002 2.22 1022 2.29 1041 2.37 External Static - in. w.g. Air Volume 0.90 1.00 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 cfm RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2400 883 1.21 907 1.25 931 1.30 955 1.35 979 1.40 1003 1.45 1027 1.51 1050 1.57 1072 1.63 1094 1.69 2500 895 1.28 919 1.32 942 1.37 966 1.42 990 1.48 1013 1.53 1036 1.59 1059 1.65 1081 1.71 1102 1.78 2600 908 1.35 931 1.40 955 1.45 978 1.50 1001 1.56 1024 1.62 1046 1.68 1068 1.74 1089 1.80 1110 1.87 2700 922 1.43 945 1.48 967 1.53 990 1.59 1013 1.65 1035 1.71 1056 1.77 1078 1.84 1099 1.90 1119 1.96 2800 936 1.51 958 1.56 980 1.62 1003 1.68 1025 1.74 1046 1.80 1067 1.87 1088 1.93 1109 2.00 1129 2.06 2900 950 1.60 972 1.66 994 1.72 1016 1.78 1037 1.84 1058 1.91 1079 1.97 1099 2.04 1119 2.11 1139 2.17 3000 965 1.69 986 1.76 1008 1.82 1029 1.88 1050 1.95 1070 2.02 1091 2.08 1110 2.15 1130 2.22 1149 2.28 3100 980 1.80 1001 1.86 1022 1.93 1043 2.00 1063 2.07 1083 2.13 1103 2.20 1122 2.27 1141 2.33 1160 2.40 3200 995 1.91 1016 1.98 1036 2.05 1057 2.12 1077 2.19 1096 2.26 1116 2.33 1134 2.39 1153 2.46 1171 2.52 3300 1011 2.03 1031 2.11 1051 2.18 1071 2.25 1091 2.32 1110 2.39 1129 2.45 1147 2.52 1165 2.59 1183 2.65 3400 1027 2.16 1047 2.24 1067 2.31 1086 2.38 1105 2.45 1124 2.52 1142 2.59 1160 2.66 1178 2.72 1196 2.78 3500 1043 2.30 1063 2.38 1082 2.45 1101 2.52 1120 2.59 1138 2.66 1156 2.73 1174 2.80 1191 2.86 1208 2.92 3600 1060 2.45 1079 2.52 1098 2.60 1117 2.67 1135 2.74 1153 2.81 1170 2.87 1188 2.94 1205 3.00 1222 3.06 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 24 BLOWER DATA BELT DRIVE KIT SPECIFICATIONS - 036-072 Model Motor HP No. of No. Nominal Maximum Speeds A01 036 0.75 0.86 1 673-1010 1 1.15 1 673-1010 1.5 1.7 1 673-1010 2 2.3 1 673-1010 048 0.75 0.86 1 --1 1.15 1 --1.5 1.7 1 --2 2.3 1 --060 0.75 0.86 1 --1 1.15 1 --1.5 1.7 1 --2 2.3 1 --072 1 1.5 1 --2 2.3 1 --- A02 --------745-1117 745-1117 745-1117 745-1117 ------------- Drive Kits and RPM Range A03 A04 A05 A06 A07 A08 ----897-1346 ----------897-1346 ----------897-1346 ----------897-1346 ------------1071-1429 ----------1071-1429 ----------1071-1429 ----------1071-1429 ----833-1250 ------1212-1548 --833-1250 ------1212-1548 --833-1250 ------1212-1548 --833-1250 ------1212-1548 ----968-1340 ------1193-1591 --968-1340 ------1193-1591 NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished are shown. In Canada, nominal motor hp is also maximum usable motor hp. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on the motor nameplate. BELT DRIVE KIT SPECIFICATIONS - 090 Model Motor HP No. of No. Nominal Maximum Speeds 090 1 2 3 1.15 2.3 3.45 1 1 1 AA01 522-784 ----- Drive Kits and RPM Range AA02 AA03 ----632-875 798-1105 ----- AA04 ----921-1228 NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor hp required. Maximum usable hp of motors furnished are shown. In Canada, nominal motor hp is also maximum usable motor hp. If motors of comparable hp are used, be sure to keep within the service factor limitations outlined on the motor nameplate. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 25 BLOWER DATA OPTIONS / ACCESSORIES AIR RESISTANCE FOR 036-072 MODELS - in. w.g. Air Volume cfm 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 036-048 0.01 0.02 0.03 0.04 0.05 0.06 0.08 0.09 0.10 0.11 0.13 0.14 Wet Indoor Coil 060 0.01 0.02 0.04 0.05 0.06 0.07 0.09 0.10 0.12 0.13 0.15 0.16 Economizer 072 0.01 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0.12 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.05 0.05 0.06 0.06 0.06 Electric Heat 0.01 0.03 0.06 0.09 0.12 0.15 0.18 0.20 0.22 0.24 0.26 0.28 Filters MERV 8 0.04 0.04 0.04 0.04 0.04 0.05 0.05 0.05 0.05 0.05 0.05 0.05 MERV 13 0.05 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 OPTIONS / ACCESSORIES AIR RESISTANCE FOR 090 MODELS - in. w.g. Air Volume cfm Wet Indoor Coil 2400 2600 2800 3000 3200 3400 3600 0.08 0.09 0.10 0.11 0.12 0.14 0.15 Economizer 0.05 0.06 0.06 0.06 0.06 0.06 0.06 POWER EXHAUST FAN PERFORMANCE Return Air System Static Air Volume Exhausted Pressure - in. w.g. cfm 0.00 2000 0.05 1990 0.10 1924 0.15 1810 0.20 1664 0.25 1507 0.30 1350 0.35 1210 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 26 Electric Heat 0.22 0.24 0.26 0.28 0.30 0.32 0.34 Filters MERV 8 0.05 0.05 0.05 0.05 0.06 0.06 0.06 MERV 13 0.08 0.08 0.08 0.08 0.09 0.09 0.10 BLOWER DATA CEILING DIFFUSERS AIR RESISTANCE (in. w.g.) RTD9-65S Step–Down Diffuser RTD11-95S Step–Down Diffuser 2 Ends Open 1 Side & 2 Ends Open All Ends & Sides Open FD9-65S Flush Diffuser 2 Ends Open 1 Side & 2 Ends Open All Ends & Sides Open FD11-95S Flush Diffuser 800 0.15 0.13 0.11 0.11 --- --- --- --- 1000 0.19 0.16 0.14 0.14 --- --- --- --- 1200 0.25 0.20 0.17 0.17 --- --- --- --- 1400 0.33 0.26 0.20 0.20 --- --- --- --- 1600 0.43 0.32 0.20 0.24 --- --- --- --- 1800 0.56 0.40 0.30 0.30 0.13 0.11 0.09 0.09 2000 0.73 0.50 0.36 0.36 0.15 0.13 0.11 0.10 2200 0.95 0.63 0.44 0.44 0.18 0.15 0.12 0.12 2400 --- ---- --- --- 0.21 0.18 0.15 0.14 2600 --- ---- --- --- 0.24 0.21 0.18 0.17 2800 --- ---- --- --- 0.27 0.24 0.21 0.20 3000 --- ---- --- --- 0.32 0.29 0.25 0.25 3200 --- ---- --- --- 0.41 0.37 0.32 0.31 3400 --- ---- --- --- 0.50 0.45 0.39 0.37 3600 --- ---- --- --- 0.61 0.54 0.48 0.44 Air Volume cfm CEILING DIFFUSER AIR THROW DATA 1 Air Volume cfm 1 Effective Throw - ft. Model No. RTD9-65S FD9-65S 800 10 - 17 14 - 18 1000 10 - 17 15 - 20 1200 11 - 18 16 - 22 1400 12 - 19 17 - 24 1600 12 - 20 18 - 25 1800 13 - 21 20 - 28 2000 14 - 23 21 - 29 2200 16 - 25 22 - 30 Model No. RTD11-95S FD11-95S 2600 24 - 29 19 - 24 2800 25 - 30 20 - 28 3000 27 - 33 21 - 29 3200 28 - 35 22 - 29 3400 30 - 37 22 - 30 3600 25 - 33 22 - 24 Effective throw based on terminal velocities of 75 ft. per minute. OUTDOOR SOUND DATA Unit Model No. Octave Band Linear Sound Power Levels dBA, re 10-12 Watts - Center Frequency - Hz 125 250 500 1000 2000 4000 8000 Sound Rating Number (SRN) (dBA) KCA036 and 048 63 66 70 71 68 62 53 75 KCA060 67 72 77 76 73 68 61 82 KCA072 and 90 66 71 74 73 70 65 57 79 1 Note - The octave sound power data does not include tonal corrections. 1 Sound Rating Number according to ARI Standard 270-95 (includes pure tone penalty). “SRN” is the overall A-Weighted Sound Power Level, (LWA), dBA (100 Hz to 10,000 Hz). Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 27 ELECTRICAL/ELECTRIC HEAT DATA 3 TON KCA036S - DIRECT AND BELT DRIVE 1 Voltage - 60hz Compressor 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph 8.7 4 3.6 Rated Load Amps Locked Rotor Amps 70 31 27 Outdoor Fan Motor Full Load Amps 1.7 1.1 0.7 Power Exhaust (1) 0.33 HP Full Load Amps 2.4 1.3 1 Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 15 Horsepower Type Maximum Overcurrent Protection Minimum Circuit Ampacity 15 20 0.5 1 2 0.5 1 2 0.5 1 2 Direct Belt Belt Direct Belt Belt Direct Belt Belt Full Load Amps 3.9 4.6 7.5 2 2.1 3.4 2 1.7 2.7 Unit Only 25 25 25 15 15 15 15 15 15 with (1) 0.33 HP Power Exhaust 25 25 30 15 15 15 15 15 15 Unit Only 17 18 21 9 9 10 8 7 8 with (1) 0.33 HP Power Exhaust 19 20 23 10 10 11 9 8 9 480V 480V 480V 600V 600V 600V ELECTRIC HEAT DATA Electric Heat Voltage 2 3 2 3 208V 240V 208V 240V 208V 240V Maximum Overcurrent Protection Unit + Electric Heat 7.5 kW 25 30 30 30 30 35 15 15 20 15 15 15 15 kW 45 50 45 60 50 60 30 30 30 25 25 25 Minimum Circuit Ampacity Unit + Electric Heat 7.5 kW 25 28 26 29 29 32 14 14 16 112 12 13 15 kW 44 50 45 51 49 55 26 26 27 21 21 22 Maximum Overcurrent Protection Unit + Electric Heat + Power Exhaust 7.5 kW 30 35 30 35 35 35 20 20 20 15 15 15 15 kW 50 60 50 60 60 60 30 30 30 25 25 25 Minimum Circuit Ampacity Unit + Electric Heat + Power Exhaust 7.5 kW 28 31 29 32 32 35 16 16 18 13 13 14 15 kW 47 53 48 54 52 58 27 27 29 22 22 23 ELECTRICAL ACCESSORIES Disconnect Standard Access - 0-7.5 kW 20W15 20W15 20W15 20W15 20W15 15 kW 20W15 20W15 20W15 20W15 20W15 Hinged Access - 0-7.5 kW 20W21 20W21 20W21 20W21 20W21 15 kW 20W21 20W21 20W21 20W21 20W21 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 28 ELECTRICAL/ELECTRIC HEAT DATA 4 TON KCA048S - DIRECT AND BELT DRIVE 1 Voltage - 60hz Compressor 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph 11 5.5 4.7 Rated Load Amps Locked Rotor Amps 86 37 34 Outdoor Fan Motor Full Load Amps 1.7 1.1 0.7 Power Exhaust (1) 0.33 HP Full Load Amps 2.4 1.3 1 Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 15 Horsepower Type Maximum Overcurrent Protection Minimum Circuit Ampacity 15 20 0.5 1 2 0.5 1 2 0.5 1 2 Direct Belt Belt Direct Belt Belt Direct Belt Belt Full Load Amps 3.9 4.6 7.5 2 2.1 3.4 2 1.7 2.7 Unit Only 30 30 30 15 15 15 15 15 15 with (1) 0.33 HP Power Exhaust 30 30 35 15 15 15 15 15 15 Unit Only 20 21 23 10 11 13 12 9 10 with (1) 0.33 HP Power Exhaust 22 23 26 12 12 13 10 10 11 ELECTRIC HEAT DATA Electric Heat Voltage 2 3 2 3 208V 240V 208V 240V 208V 240V 480V 480V 480V 600V 600V 600V Maximum Overcurrent Protection Unit + Electric Heat 7.5 kW 30 30 30 30 30 35 15 15 20 15 15 15 15 kW 45 50 45 60 50 60 30 30 30 25 25 25 Minimum Circuit Ampacity Unit + Electric Heat 7.5 kW 25 28 26 29 29 32 14 14 16 12 12 13 15 kW 44 50 45 51 49 55 26 26 27 21 21 22 Maximum Overcurrent Protection Unit + Electric Heat + Power Exhaust 7.5 kW 30 35 30 35 35 35 20 20 20 15 15 15 15 kW 50 60 50 60 60 60 30 30 30 25 25 25 Minimum Circuit Ampacity Unit + Electric Heat + Power Exhaust 7.5 kW 28 31 29 32 32 35 16 16 18 13 13 14 15 kW 47 53 48 54 52 58 27 27 29 22 22 23 ELECTRICAL ACCESSORIES Disconnect Standard Access - 0-7.5 kW 20W15 20W15 20W15 20W15 20W15 15 kW 20W15 20W15 20W15 20W15 20W15 Hinged Access - 0-7.5 kW 20W21 20W21 20W21 20W21 20W21 15 kW 20W21 20W21 20W21 20W21 20W21 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 29 ELECTRICAL/ELECTRIC HEAT DATA 5 TON KCA060S - DIRECT AND BELT DRIVE 1 Voltage - 60hz Compressor 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Rated Load Amps 13.5 8 5 Locked Rotor Amps 109 59 40 Outdoor Fan Motor Full Load Amps 2.4 1.3 1 Power Exhaust (1) 0.33 HP Full Load Amps 2.4 1.3 1 Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 15 Horsepower Minimum Circuit Ampacity 20 1 2 0.75 1 2 0.75 1 2 Direct Belt Belt Direct Belt Belt Direct Belt Belt Full Load Amps 4.9 4.6 7.5 2.5 2.1 3.4 2.5 1.7 2.7 Unit Only 35 35 40 20 20 20 15 15 15 with (1) 0.33 HP Power Exhaust 40 35 40 20 20 20 15 15 15 Unit Only 25 24 27 14 14 15 10 9 10 with (1) 0.33 HP Power Exhaust 27 27 30 16 15 16 11 10 11 Type aximum M Overcurrent Protection 15 0.75 ELECTRIC HEAT DATA Electric Heat Voltage 2 3 2 3 208V 240V 208V 240V 208V 240V 480V 480V 480V 600V 600V 600V Maximum Overcurrent Protection Unit + Electric Heat Minimum Circuit Ampacity Unit + Electric Heat Maximum Overcurrent Protection Unit + Electric Heat + Power Exhaust Minimum Circuit Ampacity Unit + Electric Heat + Power Exhaust 7.5 kW 35 35 35 35 40 40 20 20 20 15 15 15 15 kW 50 60 45 60 50 60 30 30 30 25 25 25 22.5 kW 70 80 70 80 70 80 40 40 40 35 30 35 7.5 kW 26 29 26 29 29 32 15 14 16 13 12 13 15 kW 46 52 45 51 49 55 26 26 27 22 21 22 22.5 kW 65 74 65 74 69 78 37 37 39 31 30 31 7.5 kW 40 40 35 35 40 40 20 20 20 15 15 15 15 kW 50 60 50 60 60 60 30 30 30 25 25 25 22.5 kW 70 80 70 80 80 90 40 40 40 35 35 35 7.5 kW 29 32 29 32 32 35 17 16 18 14 13 14 15 kW 49 55 48 54 52 58 28 27 29 23 22 23 22.5 kW 68 77 68 77 72 81 39 39 40 32 31 32 ELECTRICAL ACCESSORIES Disconnect Standard Access - 0-22.5 kW 20W15 20W15 20W15 20W15 20W15 Hinged Access - 0-22.5 kW 20W21 20W21 20W21 20W21 20W21 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 30 ELECTRICAL/ELECTRIC HEAT DATA 6 TON KCA072S - BELT DRIVE BLOWER 1 Voltage - 60hz Compressor 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Rated Load Amps 19.6 8.2 6.6 Locked Rotor Amps 136 66.1 55.3 Outdoor Fan Motor Full Load Amps 2.4 1.3 1 Power Exhaust (1) 0.33 HP Full Load Amps 2.4 1.3 1 Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 15 Horsepower aximum M Overcurrent Protection Minimum Circuit Ampacity 15 20 1 2 1 2 1 2 Type Belt Belt Belt Belt Belt Belt Full Load Amps 4.6 7.5 2.1 3.4 1.7 2.7 Unit Only 50 50 20 20 15 15 with (1) 0.33 HP Power Exhaust 50 50 20 20 15 15 Unit Only 32 35 14 15 11 12 with (1) 0.33 HP Power Exhaust 34 37 15 17 12 13 ELECTRIC HEAT DATA Electric Heat Voltage 2 3 2 3 Maximum Overcurrent Protection Unit + Electric Heat inimum M Circuit Ampacity Unit + Electric Heat Maximum Overcurrent Protection Minimum Circuit Ampacity Unit + Electric Heat + Power Exhaust Unit + Electric Heat + Power Exhaust 208V 240V 208V 240V 480V 480V 600V 600V 7.5 kW 50 50 50 50 20 20 15 15 15 kW 50 60 50 60 30 30 25 25 22.5 kW 70 80 70 80 40 40 30 35 30 kW 90 100 90 100 50 50 40 40 7.5 kW 32 32 35 35 14 16 12 13 15 kW 45 51 49 55 26 27 21 22 22.5 kW 65 74 69 78 37 39 30 31 30 kW 84 96 88 100 48 50 39 40 7.5 kW 50 50 50 50 20 20 15 15 15 kW 50 60 60 60 30 30 25 25 22.5 kW 70 80 80 90 40 40 35 35 30 kW 90 100 100 110 50 60 40 45 7.5 kW 34 34 37 37 16 18 13 14 15 kW 48 54 52 58 27 29 22 23 22.5 kW 68 77 72 81 39 40 31 32 30 kW 87 99 91 103 50 51 40 41 ELECTRICAL ACCESSORIES Disconnect Standard Access - 0-22.5 kW 20W18 20W18 20W18 20W18 30 kW 20W19 20W19 20W18 20W18 Hinged Access - 0-22.5 kW 20W24 20W24 20W24 20W24 30 kW 20W25 20W25 20W24 20W24 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 31 ELECTRICAL/ELECTRIC HEAT DATA 7.5 TON KCA090S - BELT DRIVE BLOWER 1 Voltage - 60hz Compressor 208/230V - 3 Ph 460V - 3 Ph 575V - 3 Ph Rated Load Amps 25 12.2 9 Locked Rotor Amps 164 100 78 Outdoor Fan Motor Full Load Amps 2.4 1.3 1 Power Exhaust (1) 0.33 HP Full Load Amps 2.4 1.3 1 Service Outlet 115V GFI (amps) Indoor Blower Motor 2 3 15 Horsepower aximum M Overcurrent Protection Minimum Circuit Ampacity 15 20 1 2 3 1 2 3 1 2 3 Type Belt Belt Belt Belt Belt Belt Belt Belt Belt Full Load Amps 4.6 7.5 10.6 2.1 3.4 4.8 1.7 2.7 3.9 Unit Only 60 60 60 30 30 30 20 20 25 with (1) 0.33 HP Power Exhaust 60 60 70 30 30 30 20 20 25 Unit Only 39 42 45 19 20 22 14 15 17 with (1) 0.33 HP Power Exhaust 41 44 47 20 22 23 15 16 18 ELECTRIC HEAT DATA Electric Heat Voltage 2 3 2 3 208V 240V 208V 240V 208V 240V 480V 480V 480V 600V 600V 600V Maximum Overcurrent Protection Unit + Electric Heat inimum M Circuit Ampacity Unit + Electric Heat Maximum Overcurrent Protection Minimum Circuit Ampacity Unit + Electric Heat + Power Exhaust Unit + Electric Heat + Power Exhaust 7.5 kW 60 60 60 60 60 60 30 30 30 20 20 25 15 kW 60 60 60 60 60 60 30 30 30 25 25 25 22.5 kW 70 80 70 80 80 90 40 40 40 30 35 35 30 kW 90 100 90 100 100 110 50 50 60 40 40 45 7.5 kW 39 39 42 42 45 45 19 20 22 14 15 17 15 kW 45 51 49 55 53 59 26 27 29 21 22 23 22.5 kW 65 74 69 78 72 81 37 39 40 30 31 32 30 kW 84 96 88 100 92 104 48 50 52 39 40 41 7.5 kW 60 60 60 60 70 70 30 30 30 20 20 25 15 kW 60 60 60 60 70 70 30 30 35 25 25 25 22.5 kW 70 80 80 90 80 90 40 40 45 35 35 35 30 kW 90 100 100 110 100 110 50 60 60 40 45 45 7.5 kW 41 41 44 44 47 47 20 22 23 15 16 18 15 kW 48 54 52 58 56 62 27 29 31 22 23 25 22.5 kW 68 77 72 81 75 84 39 40 42 31 32 34 30 kW 87 99 91 103 95 107 50 51 53 40 41 43 ELECTRICAL ACCESSORIES Disconnect Standard Access - 0-22.5 kW 20W18 20W18 20W18 20W18 20W18 30 kW 20W19 20W19 20W19 20W18 20W18 Hinged Access - 0-22.5 kW 20W24 20W24 20W24 20W24 20W24 30 kW 20W25 20W25 20W25 20W24 20W24 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. 1 Extremes of operating range are plus and minus 10% of line voltage. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 32 ELECTRIC HEAT CAPACITIES 7.5 kW 10 kW Input Voltage No of Stages kW input Btuh Output No of Stages kW input Btuh Output 208 1 5.6 19,200 1 7.5 25,600 220 1 6.3 21,500 1 8.4 28,700 230 1 6.9 23,500 1 9.2 31,400 240 1 7.5 25,600 1 10.0 34,200 440 1 6.3 21,500 --- --- --- 460 1 6.9 23,500 --- --- --- 480 1 7.5 25,600 --- --- --- 550 1 6.3 21,500 --- --- --- 575 1 6.9 23,500 --- --- --- 600 1 7.5 25,600 --- --- --- 15 kW Input Voltage 22.5 kW 30 kW No of Stages kW input Btuh Output No of Stages kW input Btuh Output No of Stages kW input Btuh Output 208 1 11.2 38,400 1 16.9 57,700 1 22.5 76,800 220 1 12.6 43,000 1 18.9 64,500 1 25.2 86,000 230 1 13.8 47,000 1 20.7 70,700 1 27.5 93,900 240 1 15.0 51,200 1 22.5 76,800 1 30.0 102,400 440 1 12.6 43,000 1 18.9 64,500 1 25.2 86,000 460 1 13.8 47,000 1 20.7 70,700 1 27.5 93,900 480 1 15.0 51,200 1 22.5 76,800 1 30.0 102,400 550 1 12.6 43,000 1 18.9 64,500 1 25.2 86,000 575 1 13.8 47,000 1 20.7 70,700 1 27.5 93,900 600 1 15.0 51,200 1 22.5 76,800 1 30.0 102,400 UNIT CLEARANCES - INCHES (MM) C B OUTDOOR AIR HOOD D A 1 Unit Clearance A B C D in. mm in. mm in. mm in. mm Service Clearance 36 914 36 914 36 914 36 914 Minimum Operation Clearance 36 914 36 914 36 914 36 914 Top Clearance Unobstructed NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface. 1 Service Clearance - Required for removal of serviceable parts. Minimum Operation Clearance - Required clearance for proper unit operation. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 33 OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS Item Model No. Catalog No. C0STAT06FF1L 13H15 COMFORTSENSE® 7500 COMMERCIAL 7-DAY PROGRAMMABLE THERMOSTAT • • • • • • • • • • • • • • • • our-Stage Heating / Two-Stage Cooling Universal Multi-Stage F Intuitive Touchscreen Interface Remote Indoor Temperature Sensing with Averaging Outside or Discharge Air Temperature Display Full Seven-Day Programming Four Time Periods Per Day Occupancy Scheduling with Economizer Relay Control Away Mode Holiday Scheduling Smooth Setback Recovery (SSR) Performance Reports Notifications/Reminders Dehumidification/Humiditrol® Control for Split Systems and Rooftop Units Economizer Relay Control Backlit Display Wallplate Furnished Optional Accessories 1 Remote non-adjustable wall mount 20k temperature sensor C0SNZN01AE2- 47W36 1 Remote non-adjustable wall mount 10k temperature sensor C0SNZN73AE1- 47W37 Remote non-adjustable discharge air (duct mount) temperature sensor C0SNDC00AE1- 19L22 Outdoor temperature sensor C0SNSR03AE1- X2658 Locking cover (clear) C0MISC15AE1- 39P21 C0STAT05FF1L 11Y05 Remote non-adjustable wall mount 10k averaging temperature sensor C0SNZN73AE1- 47W37 Optional wall mounting plate C0MISC17AE1- X2659 C0STAT12AE1L 51M32 Outdoor temperature sensor C0SNSR04AE1- X2658 Optional wall mounting plate C0MISC17AE1- X2659 1 Remote sensors can be applied in any of the following combinations: One Sensor - (1) 47W36 Two Sensors - (2) 47W37 Three Sensors - (2) 47W36 and (1) 47W37 Four Sensors - (4) 47W36 Five Sensors - (3) 47W36 and (2) 47W37 COMFORTSENSE® 3000 COMMERCIAL 5-2 DAY PROGRAMMABLE THERMOSTAT MAINT Commercial • • • • • • • • • • • wo-Stage Heating / Two-Stage Cooling Conventional Systems T Intuitive Interface 5-2 Day Programming Program Hold Remote Indoor Temperature Sensing Smooth Setback Recovery (SSR) Economizer Relay Control Maintenance/Filter/Service Reminders Backlit Display Wallplate Furnished Simple Up and Down Temperature Control. Optional Accessories DIGITAL NON-PROGRAMMABLE THERMOSTAT • • • • • One-Stage Heating / Cooling Conventional Systems Intuitive Interface Automatic Changeover Backlit Display Simple Up and Down Temperature Control. Optional Accessories Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 34 WEIGHT DATA Model Number Net Shipping Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg KCA036S 498 226 610 277 558 253 679 308 KCA048S 535 243 647 293 595 270 716 325 KCA060S 565 256 681 309 625 283 750 340 KCA072S 620 281 721 327 661 300 762 346 KCA090S 745 334 851 386 805 365 920 417 Base Unit - The unit with NO OPTIONS. Max. Unit - The unit with ALL OPTIONS installed (Economizer, etc.). OPTIONS / ACCESSORIES Shipping Weights lbs. kg ECONOMIZER / OUTDOOR AIR / power EXHAUST Economizer Economizer - Includes Barometric Relief Dampers and Exhaust Hood Outdoor Air Dampers Motorized Manual Power Exhaust Standard Static ELECTRIC HEAT 7.5 kW 10 kW 15 kW 22.5 kW 30 kW ROOF CURBs Hybrid Roof Curbs, Downflow 8 in. height 14 in. height 18 in. height 24 in. height Hybrid Curbs, Full Perimeter, Downflow 8 in. height 14 in. height 18 in. height 24 in. height Adjustable Pitch Curb, Downflow 14 in. height CEILING DIFFUSERS Step-Down Flush Transitions (Supply and Return) RTD9-65S RTD11-95S FD9-65S FD11-95S T1TRAN10AN1 T1TRAN20N-1 131 59 40 30 18 14 35 16 31 31 31 35 35 14 14 14 16 16 50 70 80 100 23 32 36 45 57 60 91 114 26 27 41 52 113 51 80 118 80 118 22 21 36 54 36 54 10 10 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 35 DIMENSIONS - UNIT - INCHES (MM) Model No. 036 048 060 072 090 AA Base lbs. kg 86 39 93 42 98 44 118 53 164 74 Max. lbs. kg 110 50 116 53 122 56 142 65 187 85 CORNER WEIGHTS BB CC Base Max. Base Max. lbs. kg lbs. kg lbs. kg lbs. kg 105 48 124 56 169 77 200 91 112 51 132 60 181 82 212 96 119 54 138 63 191 87 223 101 140 63 152 69 197 89 205 93 179 81 203 92 221 100 252 114 DD Base lbs. kg 139 63 149 68 157 72 166 75 203 92 CENTER OF GRAVITY FF Max. Base Max. in. mm in. mm in. mm 40 1016 18 457 18 457 40 1016 18 457 18 457 40 1016 18 457 18 457 44-3/4 1137 19-1/2 495 20 508 47 1194 21 533 21 533 EE Max. Base lbs. kg in. mm 177 80 38-1/2 978 187 85 38-1/2 978 197 90 38-1/2 978 251 114 39 991 231 105 47 1194 Base Unit - The unit with NO INTERNAL OPTIONS. Max. Unit - The unit with ALL INTERNAL OPTIONS Installed. (Economizer, Standard Static Power Exhaust Fans, Controls, etc.). Does not include accessories external to unit or high static power exhaust. 5-5/8 (143) AA 16-1/4 (413) 11 (279) 18 (457) BB 5 (127) 7 (178) BOTTOM RETURN AIR OPENING 29 (737) BOTTOM SUPPLY AIR OPENING 47 (1194) BASE 20 (508) CENTER OF GRAVITY 25-3/4 (654) KCA036 thru 072 38-3/4 (984) KCA090 FF 6-5/8 (168) DD 26-1/2 (673) 9-1/2 (241) CC BOTTOM CONDENSATE OUTLET EE BOTTOM POWER ENTRY 3 X 8 (76 X 203) TOP VIEW (Base) 83-1/4 (2115) KCA036 thru KCA072 96-1/4 (2445) KCA090 35-3/8 (899) KCA036 thru 060 43-3/8 (1102) KCA072 / 090 1 (25) 38-7/8 (987) KCA036 thru 060 46-7/8 (1191) KCA072 / 090 45 (1143) ELECTRICAL INLET CONDENSATE OUTLET (EITHER SIDE) 3-1/2 (89) 47 (1194) BASE END VIEW 26-1/2 (673) 5-1/2 (140) 1 (25) LIFTING HOLES (For rigging) 85-1/4 (2165) KCA036 thru KCA072 BASE 98-1/4 (2496) KCA090 BASE SIDE VIEW 19-1/2 (495) 20 (508) FORKLIFT SLOTS (Front, Back and Blower End) Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 36 18-3/8 (467) 11 (279) 2 (51) 29 (737) 5-1/2 HORIZONTAL HORIZONTAL 5-1/2 RETURN AIR (140) (140) SUPPLY AIR OPENING OPENING (Without Economizer) BACK VIEW DIMENSIONS - ACCESSORIES - INCHES (MM) OUTDOOR AIR HOOD DETAIL FOR OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Downflow Applications) 11-3/4 (298) OPTIONAL OUTDOOR AIR HOOD (Furnished with Economizer) 17-3/8 (441) OPTIONAL BAROMETRIC RELIEF HOOD (Furnished with Economizer ) OUTDOOR AIR HOOD FOR ECONOMIZER (Furnished) SIDE VIEW BAROMETRIC RELIEF HOOD FOR ECONOMIZER (Furnished) 11-3/4 (298) 17-3/8 (441) 35 (889) 35 (889) 19-7/8 (505) 13 (330) OUTDOOR AIR DAMPER HOOD DETAIL (Downflow or Horizontal Applications) 10-1/2 (267) OUTDOOR AIR DAMPER HOOD (Furnished) SIDE VIEW MANUAL OUTDOOR AIR HOOD OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889) MOTORIZED OUTDOOR AIR HOOD OPTIONAL OUTDOOR AIR DAMPERS AND PANEL 35 (889) OUTDOOR AIR DAMPER HOOD OUTDOOR AIR DAMPER HOOD 13-1/2 (343) 13-1/2 (343) 16-1/2 (419) 35 (889) 024 thru 048 43 (1092) 060 / 072 16-1/2 (419) 10-1/2 (267) 35 (889) 024 thru 048 43 (1092) 060 / 072 10-1/2 (267) Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 37 DIMENSIONS - ACCESSORIES - INCHES (MM) OUTDOOR AIR HOOD DETAIL WITH OPTIONAL ECONOMIZER AND BAROMETRIC RELIEF DAMPERS (Horizontal Applications) Barometric Relief Hood and Dampers ECONOMIZER DAMPERS SUPPLY AIR DUCT (Field Provided) SUPPLY AIR OUTLET RETURN AIR DUCT TRANSITION (Field fabricated and installed on unit) TOP VIEW RETURN AIR DUCT (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) BAROMETRIC RELIEF HOOD DIMENSIONS Width - 35-1/2 in. (902 mm) Height -21 in. (533 mm) RETURN AIR INLET See previous page for details. OUTDOOR AIR HOOD (Furnished with Economizer) 19-1/2 (495) HORIZONTAL SUPPLY AIR OPENING 31-3/8 (797) 11-3/4 (298) This opening not used in Horizontal Applications with 20 Economizer (508) NOTE - Horizontal applications with Economizer require Horizontal Economizer Conversion Kit. See Options/Accessories table. BAROMETRIC RELIEF HOOD (Furnished with Economizer and Field Installed on Field fabricated Return Air Duct) OUTDOOR AIR 7/8 (22) 2-1/4 (57) HORIZONTAL RETURN AIR OPENING 18-3/4 (476) 30-7/16 (773) 2-1/4 (57) EXHAUST AIR BACK VIEW 5-1/2 RETURN AIR (140) DUCT TRANSITION (Field fabricated and installed on unit) RETURN AIR DUCT INLET (Field Fabricated - Must be sized to accommodate Barometric Relief Hood and Return Air Requirements) NOTE - Return Air Duct and Transition must be supported. Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 38 7/8 (22) UNIT RETURN AIR DUCT OPENING WITH ECONOMIZER INSTALLED END VIEW DIMENSIONS - ACCESSORIES - INCHES (MM) HYBRID ROOF CURBS - DOUBLE DUCT OPENING - STANDARD AND FULL PERIMETER A 38 (965) B 19-1/8 (486) 41-1/2 (1054) 21-1/8 (537) 15-1/8 (384) 8 (203) 14 (356) 18 (457) 24 (610) SUPPLY OPENING 12-5/8 (321) 1-3/4 (44) 32 (813) RETURN OPENING NOTE - Roof deck may be omitted within confines of curb. DETAIL ROOF CURB TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM PACKAGED UNIT 1-3/4 (44) 1/2 (13) FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) CANT STRIP (Field Supplied) 8 (203) 14 (356) 18 (457) 24 (610) ROOFING MATERIAL RIGID INSULATION (Field Supplied) 1-3/4 (44) A Model No. B in. mm in. mm Standard - 024, 030, 036, 048, 060, 072, 090 79-3/4 2026 76-1/4 1937 Full Perimeter - 090 92-3/4 2356 89-1/4 2267 1 1 90 models can be used on smaller 79-3/4 in. (2026 mm) roof curbs (not full perimeter) with 15-3/4 in. (400 mm) 0 overhang at condenser end of unit. See dimension drawing on page 41 Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 39 DIMENSIONS - ACCESSORIES - INCHES (MM) ADJUSTABLE PITCH CURBS - DOUBLE DUCT OPENING 76-1/4 (1937) 79-3/4 (2026) 38 (965) 21-1/8 (537) 19-1/8 (486) 15-1/8 (384) 41-1/2 (1054) 14 (356) SUPPLY OPENING 12-5/8 (321) 32 (813) RETURN OPENING FACTORY INSTALLED PERIMETER WOOD NAILER STRIP BOTTOM CURB ASSEMBLY NOTE - Maximum slope pitch is 3/4 in. per 1 foot (19 mm per 305 mm) in any one direction. TYPICAL FLASHING DETAIL FOR ROOF CURB BASE BOTTOM DETAIL ROOF CURB PACKAGED UNIT 1-3/4 (44) 1/2 (13) FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) CANT STRIP (Field Supplied) ROOFING MATERIAL 14 (356) RIGID INSULATION (Field Supplied) 1-3/4 (44) Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 40 DIMENSIONS - ACCESSORIES - INCHES (MM) 090 MODELS - SHOWING OVERHANG ON SMALLER 79-3/4 INCH LENGTH ROOF CURBS (Not Full Perimeter) ROOF CURB 79-3/4 (2026) 2-3/4 (70) 15-3/4 (400) SIDE VIEW TRANSITIONS T1TRAN10AN-1 - FOR 18 INCH (457 MM) DUCT T1TRAN20N-1 - FOR 20 INCH (508 MM) DUCT 12 (305) 31-1/2 (800) 8 (203) 1-1/2 inch (38 mm) T1TRAN10AN-1 2 inch (51mm) T1TRAN20N-1 32 (813) 12-5/8 (321) 19-1/8 (486) RETURN OPENING RETURN TRANSITION SUPPLY OPENING 21-1/8 (537) T1TRAN10AN-1 - FOR 18 INCH (457 MM) DUCT T1TRAN20N-1 - FOR 20 INCH (508 MM) DUCT 18-1/2 (470) 20-1/2 (521) 8 (203) 1-1/2 inch (38 mm) T1TRAN10AN-1 2 inch (51mm) T1TRAN20N-1 SUPPLY TRANSITION Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons/ Page 41 DIMENSIONS - ACCESSORIES - INCHES (MM) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS STEP-DOWN CEILING DIFFUSER E FLUSH CEILING DIFFUSER D H G F G H G E H F G C C 2 (51) L 2 (51) A B D H A B J K Model Number A in. mm B in. mm C in. mm D in. mm E in. mm F in. mm G in. mm H in. mm J in. mm K in. mm L in. mm Duct Size RTD9-65S RTD11-95S 47-5/8 47-5/8 1159 1159 23-5/8 29-5/8 600 752 11-3/8 14-3/8 289 365 21-1/2 27-1/2 546 699 45-1/2 45-1/2 1156 1158 22-1/2 22-1/2 572 572 11-1/2 11-1/2 292 292 10-3/4 13-3/4 273 349 45-1/2 45-1/2 1156 1156 21-1/2 27-1/2 546 699 7-1/8 8-1/8 181 206 in. 18 round 20 round mm 457 round 508 round Landmark® KCA Packaged Electric / Electric 3 to 7.5 Tons / Page 42 Model Number A in. mm B in. mm C D E 1159 23-5/8 29-5/8 752 mm 343 422 in. 21 27 mm 533 686 in. in. in. in. mm Duct Size 47-5/8 1159 16-5/8 mm H 47-5/8 600 mm G FD11-95S 13-1/2 in. mm F FD9-65S 45 45 1143 1143 22-1/2 22-1/2 572 572 11-1/4 11-1/4 286 286 10-1/2 13-1/2 267 343 in. 18 round 20 round mm 457 round 508 round REVISIONS Sections Description of Change Expanded Sound Data Updated for 72 and 90 units. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.
© Copyright 2026 Paperzz