LAC-3G-SX-TX, RX

LAC-3G-SX-TX, RX
LRU Active Cable, 3Gbps
Fiber Optic Transmitter, Receiver
Features:
§
§
§
§
§
§
§
§
§
DC to 3 Gb/s Transmitter or Receiver
Compliant to 802.3z Ethernet, Fibre Channel (1x/2x/4x),
Infiniband, sFPDP, XAUI, FCAV and ARINC 818
LAC-3G-SX-TX: 850 nm VCSEL laser transmitter
LAC-3G-SX-RX: PIN receiver
Typical reach of 500 m on 50/125
o 250 m on 62.5/125 µm MMF
Pigtailed ARINC-801 connector, other options available
-40 to +85°C operating temperature standard,
Single +3.3V power supply
AC-Coupled Transmitter or Receiver Data
The LAC-3G-SX is ideal for harsh
environment connectivity because of its low
cost, size, and benefits of design flexibility
Commercial
Aerospace
Military
Aerospace
Military
Tactical
Industrial and
Oil & Gas
Absolute Maximum Ratings
PARAMETER
Maximum Supply Voltage
Storage Temperature
Operating Temperature
Relative Humidity
Conformal Coating
SYMBOL
VCC
Tsto
TOP
RH
MIN.
-0.3
-55
-40
0
0.8
MAX.
4.0
105
85
85
1.2
UNIT
V
°C
°C
%
mil
NOTES
Based on conformal coating
See ruggedization notes
General Specifications
PARAMETER
Data Rate
SYMBOL
BR
MIN.
DC
944-000080-01 [PRELIMINARY] Page 1 of 5 ©2017 | COTSWORKS, LLC
TYP.
MAX.
3
UNIT
Gb/s
NOTES
8b10b encoding
749 Miner Road, Highland Heights, OH 44143
440.446.8800 | [email protected]
LAC-3G-SX-TX, RX
LRU Active Cable, 3Gbps
Fiber Optic Transmitter, Receiver
Electrical Specifications (TOP = -40 to 85°C, VCC = 3.14 to 3.47 Volts)
PARAMETER
Transmitter (LAC-3G-SX-TX)
Supply Voltage
Supply Current
Total Module Power Dissipation
Input differential impedance
TX Common Mode Voltage
Single-Ended Input Voltage Swing
Transmit Disable Voltage
Transmit Enable Voltage
Receiver (LAC-3G-SX-RX)
Supply Voltage
Supply Current
Total Module Power Dissipation
Single-Ended Output Voltage Swing
Data Rise Time (20% to 80%)
Data Fall Time (20% to 80%)
Signal Detect Assert
Signal Detect De-assert
Deterministic Jitter Contribution
Total Jitter Contribution (p-p)
SYMBOL
MIN.
TYP.
MAX.
UNIT
VCC
ICC
PDISS
Rin
V\CM
VDTX
VD
VEN
3.14
3.3
80
90
100
2.0
3.47
120
0.42
110
1200
VCC
0.8
V
mA
W
Ω
V
mV
V
V
VCC
ICC
PDISS
VDRX
tr
tf
SDnorm
SDfault
RX∆DJ
RX∆TJ
3.14
3.3
80
300
300
3.47
120
0.42
470
135
135
VCC
0.4
0.10
0.16
V
mA
W
mV
ps
ps
V
V
UI
UI
100
1.8
-0.3
3.0
0
944-000080-01 [PRELIMINARY] Page 2 of 5 ©2017 | COTSWORKS, LLC
NOTES
LVPECL
CML
CML
LVTTL
LVTTL
CML
LVTTL
LVTTL
K28.5 test pattern
7
PRBS 2 -1 data
749 Miner Road, Highland Heights, OH 44143
440.446.8800 | [email protected]
LAC-3G-SX-TX, RX
LRU Active Cable, 3Gbps
Fiber Optic Transmitter, Receiver
Pin Configuration
Pin
Description
Symbol
1
TX Disable
N/C
2
Supply Voltage (Vcc)
VCC
Female/Receptacle (LAC Flex Connector to Host PCB)
3
Data + (Transmit or Receive)
TD+, RD+
4
Signal Ground
GND
CW PN: 110-00064
MOLEX UNIT PN: 5035481020
5
Data – (Transmit or Receive)
TD+, RD-
6
2-Wire Interface Clock
SCL
7
TX Fault or LOS (TX or RX)
TXFAULT , LOS
8
2-Wire Interface Data
SDA
9
Not Connected
N/C
10
Not Connected
Male/Plug (Host PCB Connector)
CW PN: 110-00063
MOLEX UNIT PN: 5035521019
N/C
Pin Diagram (Diagrams shown with ‘Pins-Up’ orientation*)
*When installing, the LAC receptacle pins will face downward, and PCB Plug has pins will face upward
944-000080-01 [PRELIMINARY] Page 3 of 5 ©2017 | COTSWORKS, LLC
749 Miner Road, Highland Heights, OH 44143
440.446.8800 | [email protected]
LAC-3G-SX-TX, RX
LRU Active Cable, 3Gbps
Fiber Optic Transmitter, Receiver
Optical Characteristics (TOP = -40 to 85°C, VCC = 3.14 to 3.47 Volts)
PARAMETER
Transmitter (LAC-3G-SX-TX)
Optical Output Power
Optical Wavelength
RMS Spectral Width
Extinction Ratio
Optical Rise/Fall Time
Relative Intensity Noise
Deterministic Jitter Contribution
Total Jitter Contribution (p-p)
Receiver (LAC-3G-SX-RX)
RX Sensitivity: 3.125 Gbps
Overload
Optical Center Wavelength
Return Loss
Signal Detect Assert
Signal Detect De-Assert
Signal Detect Hysteresis
Notes:
1)
2)
3)
4)
SYMBOL
MIN.
TYP.
MAX.
UNIT
POUT
λ
-5
840
850
-1
860
.85
ER
tr/tf
RIN
TX∆DJ
TX∆TJ
9
100
-117
0.12
0.18
dBm
nm
nm
dB
ps
dB/Hz
UI
UI
RXSENS
RXMAX
λc
RL
PA
PD
PA - PD
-840
12
-29
-
-15
0
860
-17
5
dBm
dBm
nm
dB
dBm
dBm
dB
s
80
-
NOTES
(1)(3)
(2)
Unfiltered 20% - 80%, (1)(2)
(2)
(4)
Transition: Low to High
Transition: High to Low
Measured at the end of a 2m to 5m 62.5µm multi-mode fiber patch cord
7
Measured running 3.125 Gb/s, PRBS 2 -1 data
Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations
7
Measured using PRBS 2 -1 pattern, BER=1E-12
Ruggedization Notes
• Parylene C coating can be used for conformal coating with a 1.0 mil ± 0.2 mil thickness through a deposition process.
o It has a 5600 VPM rating, withstands temperatures of 350°F, and is extremely resistant to oil/dirt, and object impact.
• Contact COTSWORKS for all MSDS, detailed case composition, and burn analysis.
Reference Information
• IEEE Standard 802.3, 2002 Edition
944-000080-01 [PRELIMINARY] Page 4 of 5 ©2017 | COTSWORKS, LLC
749 Miner Road, Highland Heights, OH 44143
440.446.8800 | [email protected]
LAC-3G-SX-TX, RX
LRU Active Cable, 3Gbps
Fiber Optic Transmitter, Receiver
Regulatory Compliance
• COTSWORKS transceivers are Class 1 Laser Products and designed to comply with US FDA regulations.
• These products are designed to comply with Class 1 eye safety requirements of EN (IEC) 60825 and the electrical safety
requirements of EN (IEC) 60950.
Warnings:
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free
environment is highly recommended.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect
radiation.
Ordering Information
LAC-3G-SX
-XX-
-xx-
x
-x-
xx
-xx
LAC Form
Factor
Function
Fiber Termini
Connector
Type
Ruggedized
Coating
Operating
Temp (°C)
Flex Length
(cm)
Fiber
Length
(cm)
():
30cm
():
30cm
xx:
Other
xx:
Other
3 Gbps Max
Data Rate
TX:
850nm
VSCEL
Transmitter
LC:
LC Receptacle
():
Non-coated
(MMF)
RX:
850nm
PIN
Receiver
LX:
ARINC-801
Receptacle
R:
Parylene
A:
-40 to 85
Example part number: LAC-3G-SX-RX-LX-R-A
[3G LAC Form Factor Receiver, 850nm,
ARINC-801 terminated MMF pigtail, Parylene-coated, industrial operating temp range]
COTSWORKS and the COTSWORKS logo are registered trademarks of COTSWORKS, LLC.
COTSWORKS reserves the right to change, alter, or revise this document without notice unless otherwise agreed
944-000080-01 [PRELIMINARY] Page 5 of 5 ©2017 | COTSWORKS, LLC
749 Miner Road, Highland Heights, OH 44143
440.446.8800 | [email protected]