LAC-3G-SX-TX, RX LRU Active Cable, 3Gbps Fiber Optic Transmitter, Receiver Features: § § § § § § § § § DC to 3 Gb/s Transmitter or Receiver Compliant to 802.3z Ethernet, Fibre Channel (1x/2x/4x), Infiniband, sFPDP, XAUI, FCAV and ARINC 818 LAC-3G-SX-TX: 850 nm VCSEL laser transmitter LAC-3G-SX-RX: PIN receiver Typical reach of 500 m on 50/125 o 250 m on 62.5/125 µm MMF Pigtailed ARINC-801 connector, other options available -40 to +85°C operating temperature standard, Single +3.3V power supply AC-Coupled Transmitter or Receiver Data The LAC-3G-SX is ideal for harsh environment connectivity because of its low cost, size, and benefits of design flexibility Commercial Aerospace Military Aerospace Military Tactical Industrial and Oil & Gas Absolute Maximum Ratings PARAMETER Maximum Supply Voltage Storage Temperature Operating Temperature Relative Humidity Conformal Coating SYMBOL VCC Tsto TOP RH MIN. -0.3 -55 -40 0 0.8 MAX. 4.0 105 85 85 1.2 UNIT V °C °C % mil NOTES Based on conformal coating See ruggedization notes General Specifications PARAMETER Data Rate SYMBOL BR MIN. DC 944-000080-01 [PRELIMINARY] Page 1 of 5 ©2017 | COTSWORKS, LLC TYP. MAX. 3 UNIT Gb/s NOTES 8b10b encoding 749 Miner Road, Highland Heights, OH 44143 440.446.8800 | [email protected] LAC-3G-SX-TX, RX LRU Active Cable, 3Gbps Fiber Optic Transmitter, Receiver Electrical Specifications (TOP = -40 to 85°C, VCC = 3.14 to 3.47 Volts) PARAMETER Transmitter (LAC-3G-SX-TX) Supply Voltage Supply Current Total Module Power Dissipation Input differential impedance TX Common Mode Voltage Single-Ended Input Voltage Swing Transmit Disable Voltage Transmit Enable Voltage Receiver (LAC-3G-SX-RX) Supply Voltage Supply Current Total Module Power Dissipation Single-Ended Output Voltage Swing Data Rise Time (20% to 80%) Data Fall Time (20% to 80%) Signal Detect Assert Signal Detect De-assert Deterministic Jitter Contribution Total Jitter Contribution (p-p) SYMBOL MIN. TYP. MAX. UNIT VCC ICC PDISS Rin V\CM VDTX VD VEN 3.14 3.3 80 90 100 2.0 3.47 120 0.42 110 1200 VCC 0.8 V mA W Ω V mV V V VCC ICC PDISS VDRX tr tf SDnorm SDfault RX∆DJ RX∆TJ 3.14 3.3 80 300 300 3.47 120 0.42 470 135 135 VCC 0.4 0.10 0.16 V mA W mV ps ps V V UI UI 100 1.8 -0.3 3.0 0 944-000080-01 [PRELIMINARY] Page 2 of 5 ©2017 | COTSWORKS, LLC NOTES LVPECL CML CML LVTTL LVTTL CML LVTTL LVTTL K28.5 test pattern 7 PRBS 2 -1 data 749 Miner Road, Highland Heights, OH 44143 440.446.8800 | [email protected] LAC-3G-SX-TX, RX LRU Active Cable, 3Gbps Fiber Optic Transmitter, Receiver Pin Configuration Pin Description Symbol 1 TX Disable N/C 2 Supply Voltage (Vcc) VCC Female/Receptacle (LAC Flex Connector to Host PCB) 3 Data + (Transmit or Receive) TD+, RD+ 4 Signal Ground GND CW PN: 110-00064 MOLEX UNIT PN: 5035481020 5 Data – (Transmit or Receive) TD+, RD- 6 2-Wire Interface Clock SCL 7 TX Fault or LOS (TX or RX) TXFAULT , LOS 8 2-Wire Interface Data SDA 9 Not Connected N/C 10 Not Connected Male/Plug (Host PCB Connector) CW PN: 110-00063 MOLEX UNIT PN: 5035521019 N/C Pin Diagram (Diagrams shown with ‘Pins-Up’ orientation*) *When installing, the LAC receptacle pins will face downward, and PCB Plug has pins will face upward 944-000080-01 [PRELIMINARY] Page 3 of 5 ©2017 | COTSWORKS, LLC 749 Miner Road, Highland Heights, OH 44143 440.446.8800 | [email protected] LAC-3G-SX-TX, RX LRU Active Cable, 3Gbps Fiber Optic Transmitter, Receiver Optical Characteristics (TOP = -40 to 85°C, VCC = 3.14 to 3.47 Volts) PARAMETER Transmitter (LAC-3G-SX-TX) Optical Output Power Optical Wavelength RMS Spectral Width Extinction Ratio Optical Rise/Fall Time Relative Intensity Noise Deterministic Jitter Contribution Total Jitter Contribution (p-p) Receiver (LAC-3G-SX-RX) RX Sensitivity: 3.125 Gbps Overload Optical Center Wavelength Return Loss Signal Detect Assert Signal Detect De-Assert Signal Detect Hysteresis Notes: 1) 2) 3) 4) SYMBOL MIN. TYP. MAX. UNIT POUT λ -5 840 850 -1 860 .85 ER tr/tf RIN TX∆DJ TX∆TJ 9 100 -117 0.12 0.18 dBm nm nm dB ps dB/Hz UI UI RXSENS RXMAX λc RL PA PD PA - PD -840 12 -29 - -15 0 860 -17 5 dBm dBm nm dB dBm dBm dB s 80 - NOTES (1)(3) (2) Unfiltered 20% - 80%, (1)(2) (2) (4) Transition: Low to High Transition: High to Low Measured at the end of a 2m to 5m 62.5µm multi-mode fiber patch cord 7 Measured running 3.125 Gb/s, PRBS 2 -1 data Class 1 Laser Safety per FDA/CDRH and IEC-825-1 regulations 7 Measured using PRBS 2 -1 pattern, BER=1E-12 Ruggedization Notes • Parylene C coating can be used for conformal coating with a 1.0 mil ± 0.2 mil thickness through a deposition process. o It has a 5600 VPM rating, withstands temperatures of 350°F, and is extremely resistant to oil/dirt, and object impact. • Contact COTSWORKS for all MSDS, detailed case composition, and burn analysis. Reference Information • IEEE Standard 802.3, 2002 Edition 944-000080-01 [PRELIMINARY] Page 4 of 5 ©2017 | COTSWORKS, LLC 749 Miner Road, Highland Heights, OH 44143 440.446.8800 | [email protected] LAC-3G-SX-TX, RX LRU Active Cable, 3Gbps Fiber Optic Transmitter, Receiver Regulatory Compliance • COTSWORKS transceivers are Class 1 Laser Products and designed to comply with US FDA regulations. • These products are designed to comply with Class 1 eye safety requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC) 60950. Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Ordering Information LAC-3G-SX -XX- -xx- x -x- xx -xx LAC Form Factor Function Fiber Termini Connector Type Ruggedized Coating Operating Temp (°C) Flex Length (cm) Fiber Length (cm) (): 30cm (): 30cm xx: Other xx: Other 3 Gbps Max Data Rate TX: 850nm VSCEL Transmitter LC: LC Receptacle (): Non-coated (MMF) RX: 850nm PIN Receiver LX: ARINC-801 Receptacle R: Parylene A: -40 to 85 Example part number: LAC-3G-SX-RX-LX-R-A [3G LAC Form Factor Receiver, 850nm, ARINC-801 terminated MMF pigtail, Parylene-coated, industrial operating temp range] COTSWORKS and the COTSWORKS logo are registered trademarks of COTSWORKS, LLC. COTSWORKS reserves the right to change, alter, or revise this document without notice unless otherwise agreed 944-000080-01 [PRELIMINARY] Page 5 of 5 ©2017 | COTSWORKS, LLC 749 Miner Road, Highland Heights, OH 44143 440.446.8800 | [email protected]
© Copyright 2026 Paperzz