THE UK’S LARGEST INDEPENDENT LIFT CONTROL PANEL MANUFACTURER A 3 YE NTEE ARA R GU ESCALATOR CONTROLLERS Lester Controls offer a range of bespoke Escalator Controllers for common types of escalator. TYPE 1 (500h x 500w x 200d) This is our basic relay controller for forward/reverse operation. Mains isolator, 6 pin test socket with blanking plug and lifting handles on the top of the cabinet are included. Three fault indicator lights are fitted to the door to assist in fault finding. The controller incorporates an ISM (intelligent step monitoring) unit which provides additional safety checking for missing step monitoring as well as brake lift and handrail movement. This system is fully compliant with the BS EN 115-2:2010 part 2 rules for the improvement of safety of existing escalators and moving walkways. Head Office & Manufacturing Lester Control Systems Limited Unit D 18 Imperial Way Croydon Surrey CR0 4RR T: +44(0)20 8288 0668 | F: +44(0)20 8288 0667 Research, Development, Design & Manufacturing Lester Control Systems Limited Units 2-4 Wycliffe Industrial Park Leicester Road Lutterworth Leicestershire LE17 4HG T: +44(0)1455 204983 | F: +44(0)1455 557780 ANCILLARY EQUIPMENT SUPPLIED • Top pit ½ way wiring junction box • Bottom pit ½ way wiring junction box with test socket and plug • Remote engineer’s handset control station • Inductive Proximity Switcher can be supplied for the following functions: • Motor speed detection • Broke lift (x2) • Handrail movement (x2) • Missing step top and bottom (x2) Sensors are E2A PNP type: • M12-WP-B1 Sensing distance: 4mm • M18-WP-B1 Sensing distance: 8mm • M30-WP-B1 Sensing distance: 30mm TYPE 2 (600h x 600w x 210d) A basic controller as above but has the addition of a fault logging system with remote fault display screen for mounting in the skirting. This system also incorporates under/over speed monitoring of the main drive motor, missing step feature, brake lifted and left and right handrail movement monitoring, as required by the BS EN 115-2:2010 PART 2 rules for the improvement of safety of existing escalators and moving walkways, using the fault logger microprocessor board. TYPE 3 (760h x 760w x 210d) Again the same as TYPE 2 but with the addition of a VVVF drive for slowing and/or stopping the machine during quiet operational periods. This results in a good power saving; typically a 50% energy saving when run at half speed. Also included is non-use monitoring through a photocell beam at the top and bottom entrances. The panel size reduces to 600h x 600w x 210d if the drive is to be mounted separately. Control voltage: 110v AC. Signalling of additional safety devices: 24v DC. All information is for guidance only, E & OE ©Copyright 2016, Lester Controls Systems Ltd, All rights reserved A 3 YE NTEE ARA R GU 2
© Copyright 2026 Paperzz