Installation/mounting instruction - Trend Partner

Installation Instructions - Mounting
IQVIEW4/FPK ADAPTOR
Touch Screen Display FPK Adaptor Plate
Important: Retain these instructions
These instructions shall be used by trained service
personnel only. If the equipment is used in a manner
not specified by these instructions, the protection
provided by the equipment may be impaired.
Contents
1.
2.
2.1
Box Contents..................................................................1
Installation Instructions..................................................1
Starting Installation........................................................1
1
Box Contents
https://partners.trendcontrols.com
2.2
2.3
2.4.
2.5.
3. Replacing an FPK or an Old GDP Display Panel..............2
Replacing an Old FPK Display Panel.............................3
Replacing an NDP or an GDP+ Display Panel..............5
Completing Installation (all panels)................................7
Disposal..........................................................................8
IQView4/FPK ADAPTOR PLATE
Installation Instructions (TG201039)
IQVIEW4/FPK ADAPTOR PLATE
Installation Instructions - Template
Installation Instructions - Template
IQVIEW4/FPK ADAPTOR PLATE
Touch Screen Display/FPK Adaptor Plate
Important: Retain these instructions
210 mm (8.27”)
NOTE: Print to size.
Check dimensions below
A
B
C
192 mm (7.56”)
190 mm (7.48”)
C
IQView4/FPK ADAPTOR PLATE Template (TG201040)
A Use 192 mm width for FPK, Old GDP,
NDP, or GDP+.
B Use existing width (190 mm) for Old
FPK,
cutout for FPK, NDP, and GDP displays
A B
then extend down to new height
C Drill 4 holes O 6mm
89 mm (3.5”)
4”
81 mm (3.19”)
C D
10 cm
162 mm
position of IQView4 display
10 cm
4”
!
B
WARNING
Do not use any other screws than
those provided. Failure to comply
could cause damage to the unit
cutout for Old FPK display
Please send any comments about this or any other Trend technical publication to [email protected]
© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the
Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois
3, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes
to the content hereof without obligation to notify any person of such revisions or changes.
96 mm (3.78”)
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK.
Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com
Trend Control Systems USA
6670 185th Avenue NE, Redmond, Washington 98052, USA.
Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com
1
IQView4/FPK Adaptor Plate Installation Instructions - Template TG201040 Issue 1, draft 1 dd/mm/yy
2Installation
2.1
Starting Installation
Physical
240 mm (9.45”)
15 mm (0.59”) (typical)
2 mm (0.08”)
208 mm (8.19”)
1
M5 x 10 thread
panel width:
5 mm (0.2”) maximum
2 mm (0.08”) Foam Gasket
2
Check if FPK or Old GDP
DP
A
B
Go To Section 2.2
Replacing an FPK
or an Old GDP
or
C
D
FPK
(DP with membrane M1)
Old GDP
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-20151
IQVIEW4/FPK ADAPTOR
2.1
Installation Instructions - Mounting
STARTInG InSTAllATIOn (continued)
2
Check if FPK or Old GDP (continued)
Go To Section 2.3
Replacing an Old FPK
A B
C D
Old FPK
(Old DP with membrane M1)
NDP
or
NDP
2.2
1
2
3
4
5
6
7
8
9
0
Go To Section 2.4
Replacing an NDP
or GDP+
GDP+
REPlACInG An FPK OR An OlD GDP DISPlAY PAnEl
1
Switch Off
2
Disconnect Panel
O
I
3
Remove FPK or Old GDP Display Panel
panel
undo 4 screws
See Section 3
Disposal
2
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015.
Installation Instructions - Mounting
2.2
IQVIEW4/FPK ADAPTOR
REPlACInG An FPK OR An OlD GDP DISPlAY PAnEl (continued)
4
Prepare Panel
IQVIEW4/FPK ADAPTOR PLATE
Installation Instructions - Template
Installation Instructions - Template
IQVIEW4/FPK ADAPTOR PLATE
Touch Screen Display/FPK Adaptor Plate
Important: Retain these instructions
210 mm (8.27”)
NOTE: Print to size.
Check dimensions below
A
B
C
192 mm (7.56”)
190 mm (7.48”)
C
A Use 192 mm width for FPK, Old GDP,
NDP, or GDP+.
B Use existing width (190 mm) for Old
FPK,
cutout for FPK, NDP, and GDP displays
A B
IQView4/FPK Adaptor Plate Template,
(TG201040)
then extend down to new height
C Drill 4 holes O 6mm
89 mm (3.5”)
4”
81 mm (3.19”)
C D
10 cm
162 mm
position of IQView4 display
10 cm
4”
!
B
WARNING
Do not use any other screws than
those provided. Failure to comply
could cause damage to the unit
cutout for Old FPK display
Please send any comments about this or any other Trend technical publication to [email protected]
© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the
Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois
3, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes
to the content hereof without obligation to notify any person of such revisions or changes.
96 mm (3.78”)
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK.
Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com
Trend Control Systems USA
6670 185th Avenue NE, Redmond, Washington 98052, USA.
Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com
IQView4/FPK Adaptor Plate Installation Instructions - Template TG201040 Issue 1, draft 1 dd/mm/yy
1
162 mm (6.38”)
192 mm (7.56”)
rear view
210 mm (8.27”)
5
2.3
178 mm (7.01”)
drill 4 holes
Ø 6 mm (0.24”).
8 mm (0.31”)
9 mm (0.35”)
Complete Installation
Go To Section 2.5 Completing Installation (all panels)
Replacing an Old FPK Display Panel
1
Switch Off
2
Disconnect Panel
O
I
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015
3
IQVIEW4/FPK ADAPTOR
2.3
Installation Instructions - Mounting
REPlACInG An OlD FPK DISPlAY PAnEl (continued)
3
Remove Old FPK Display Panel
undo 8 nuts
See Section 3
Disposal
panel
4
Prepare Panel
IQVIEW4/FPK ADAPTOR PLATE
Installation Instructions - Template
Installation Instructions - Template
IQVIEW4/FPK ADAPTOR PLATE
Touch Screen Display/FPK Adaptor Plate
Important: Retain these instructions
210 mm (8.27”)
NOTE: Print to size.
Check dimensions below
A
B
C
192 mm (7.56”)
190 mm (7.48”)
C
A Use 192 mm width for FPK, Old GDP,
NDP, or GDP+.
B Use existing width (190 mm) for Old
FPK,
IQView4/FPK Adaptor Plate Template,
(TG201040)
cutout for FPK, NDP, and GDP displays
A B
then extend down to new height
C Drill 4 holes O 6mm
89 mm (3.5”)
4”
81 mm (3.19”)
C D
10 cm
162 mm
position of IQView4 display
10 cm
4”
!
B
WARNING
Do not use any other screws than
those provided. Failure to comply
could cause damage to the unit
cutout for Old FPK display
Please send any comments about this or any other Trend technical publication to [email protected]
© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the
Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois
3, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes
to the content hereof without obligation to notify any person of such revisions or changes.
96 mm (3.78”)
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK.
Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com
Trend Control Systems USA
6670 185th Avenue NE, Redmond, Washington 98052, USA.
Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com
IQView4/FPK Adaptor Plate Installation Instructions - Template TG201040 Issue 1, draft 1 dd/mm/yy
1
rear view
62 mm (2.44”)
162 mm (6.38”)
190 mm (7.48”)
210 mm (8.27”)
drill 4 holes
Ø 6 mm (0.24”).
4
8 mm (0.31”)
178 mm (7.01”)
9 mm (0.35”)
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015.
Installation Instructions - Mounting
2.3
REPlACInG An OlD FPK DISPlAY PAnEl
5
IQVIEW4/FPK ADAPTOR
(continued)
Complete Installation
Go To Section 2.5
Completing Installation (all panels)
2.4 REPlACInG An nDP OR GDP+ DISPlAY PAnEl
1
Switch Off
O
I
2
Disconnect Panel
Either; NDP
3
Or; GDP+
Remove FPK or GDP+ Display Panel
undo 8 nuts
panel
See Section 3
Disposal
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015
5
IQVIEW4/FPK ADAPTOR
Installation Instructions - Mounting
2.4 REPlACInG An nDP OR GDP+ DISPlAY PAnEl (continued)
4
Prepare Panel
IQVIEW4/FPK ADAPTOR PLATE
Installation Instructions - Template
Installation Instructions - Template
IQVIEW4/FPK ADAPTOR PLATE
Touch Screen Display/FPK Adaptor Plate
Important: Retain these instructions
210 mm (8.27”)
NOTE: Print to size.
Check dimensions below
A
B
C
192 mm (7.56”)
190 mm (7.48”)
C
A Use 192 mm width for FPK, Old GDP,
NDP, or GDP+.
B Use existing width (190 mm) for Old
FPK,
IQView4/FPK Adaptor Plate Template,
(TG201040)
cutout for FPK, NDP, and GDP displays
A B
then extend down to new height
C Drill 4 holes O 6mm
89 mm (3.5”)
4”
81 mm (3.19”)
C D
10 cm
162 mm
position of IQView4 display
10 cm
B
4”
!
WARNING
Do not use any other screws than
those provided. Failure to comply
could cause damage to the unit
cutout for Old FPK display
Please send any comments about this or any other Trend technical publication to [email protected]
© 2008 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the
Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois
3, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes
to the content hereof without obligation to notify any person of such revisions or changes.
96 mm (3.78”)
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK.
Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trend-controls.com
Trend Control Systems USA
6670 185th Avenue NE, Redmond, Washington 98052, USA.
Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com
1
IQView4/FPK Adaptor Plate Installation Instructions - Template TG201040 Issue 1, draft 1 dd/mm/yy
192 mm (7.56”)
6 mm
(0.24”)
138 mm (5.43”)
162 mm (6.38”)
186 mm (7.32”)
24 mm (0.95”)
rear view
210 mm (8.27”)
8 mm (0.31”)
178 mm (7.01”)
9 mm (0.35”)
drill 4 holes
Ø 6 mm (0.24”).
5
6
Complete Installation
Go To Section 2.5
Completing Installation (all panels)
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015.
Installation Instructions - Mounting
2.5
COMPlETInG InSTAllATIOn
1
Mount Adaptor Plate
2
Mount IQView4
IQVIEW4/FPK ADAPTOR
(continued)
WARnInG
!
3
Do not use any other screws than those
provided. Failure to comply could cause
damage to the unit
Install and Configure IQView4
IQView4 Installation Instructions (TG201038)
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015
7
IQVIEW4/FPK ADAPTOR
Installation Instructions - Mounting
3Disposal
WEEE Directive:
At the end of their useful life the packaging and
product should be disposed of by a suitable
recycling centre.
Do not dispose of with normal household waste. Do not burn.
Please send any comments about this or any other Trend technical
publication to [email protected]
TR CU Certification
© 2015 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls
Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation
to notify any person of such revisions or changes.
Trend Control Systems Limited
Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com
8
IQView4/FPK Adaptor Plate Installation Instructions TG201039 Issue 2, 04-Sep-2015.