HO & Unit-I: #764, 4th Phase 707, Yelahanka New Town, Bangalore - 560 064. Ph : +91 80 32904489 / 28461777 TeleFax : +91 80 41272461 E-mail: [email protected] Unit-II: Gautham Garden, # 4 Veerapandi,Coimbatore - 641 019 Ph : +91 422 2697200. TeleFax : +91 422 2695200 E-mail: [email protected] Unit-III: Plot No.: 323/19, Camp Road, Selaqi, Dehradun, UTTARANCHAL-248 197 Ph: + 91 97600 02492 / 12492 E-mail: [email protected] www.elmeasure.com PROGRAMMING GUIDE – POWER FACTOR CONROLLER 1. FEATURES • • • • • STAR (Wye)/ DELTA Programmable. Auxiliary supply of 180 - 300 VAC / DC. PT ratio / CT ratio programmable including CT secondary 3 phase measurement Capacitor value programmable • • • 6/8/12 stages optional Automatic or Manual Control Four Quadrant Operation • • Fault Detection Intelligent Power Factor Controlling based on the capacitor bank switching history 2. CONNECTION DIAGRAM Star Connection(3E) 3 Phase 4 Wire system Delta Connection(2E) 3 Phase 3 Wire system 3. KEY FUNCTIONS Key In SET (Programming) mode In RUN (Measurement) mode RIGHT To select the value and to accept the value NO ACTION UP To edit the value/system type up-ward in edit mode and scroll through the parameters. To scroll pages in upward direction and view different parameters. DOWN To edit the value/system type down-ward in edit mode and scroll through the parameters. To scroll pages in upward direction and view different parameters. 4. ENTERING CONFIGURATION (SETUP) MODE To configure the setup parameters in PFC meter through front panel keys, the following steps can be followed. Step Actions Display Reads Range/Options/Comments 1 Press RIGHT & UP keys together to enter SETUP SETUP 2 Press DOWN key 0000PW (Password) with first digit “0” blinking. 3 Press UP key once to increment the first digit to “1”. PASSWORD = 1000 (default/factory set). If any other password is already set move up and down key to set the right password 4 Press RIGHT key four times to accept the password. display StAr.EL (Displays last programmed type) Defines the power system configuration. Options: STAR /DELTA 5 Press RIGHT key to select required system type StAr.EL/ dELtA.EL (selected mode blinks) 6 Press UP/DOWN key to select StAr/ dELtA.EL Page 1 of 5 PG/iPFC/V2/0114 7 Press RIGHT key to accept selected system type stabilizes 8 Press DOWN key. xxxx P.P (PT Primary) (415.0 -default/factory set) 9 Press RIGHT key to set the PT primary value xxxx P.P (PT Primary) First digit blinking, can be edited using UP/DOWN key. 10 Press RIGHT key to accept the edited value for first digit. xxxx P.P (PT Primary) Second digit blinking, can be edited using UP/DOWN key. Press RIGHT key to accept the edited value. Continue the same method till fourth digit. Program Range for PT Primary : 100V to 999kV 11 Press RIGHT key xxxx P.P (PT Primary) Decimal point blinking. Can be set at appropriate location using UP/DOWN key. Ascertain the correct scale (Kilo/Mega/Giga) is selected. Kilo/Mega/Giga is placed on the right hand side of the display as K/M/G. Press RIGHT key to accept the edited value. Eg: To set 11.00kV Set first four digits (1100) as explained above press UP/DOWN key to place decimal point at appropriate location USE UP/DOWN KEY Letter K/M/G will indicate the Kilo/Mega/Giga. 12 Press DOWN key to go to the next parameter. xxxx P.S (PT Secondary) (415.0 -default/factory set) Follow the procedure as described in steps 9 to 11. Range: 50V to 550V. If value set is above this limit, display returns to the maximum PT sec value acceptable. 13 Press DOWN key xxxx C.P (CT Primary) (5.000 -default/factory set) Repeat steps 9 to 11 to change the settings. Program Range for CT Primary: 0.5A to 99kA 14 Press DOWN key xxxx C.S(CT Secondary) (5.000 -default/factory set) Repeat steps 9 to 11 to change the settings. Range: 0.5A to 6A. If value set is above this limit, it returns to the maximum CT sec value acceptable. 15 Press DOWN key Arth UA (Method of VA Selection). Arithmetic (Arith), Vector harmonics (UEC.Hor). Vector (VECtor) can be selected using UP/DOWN key. 18 Press Down key 12.00 n.r. (no.of relays) Range: 1 to 12 (Depends on the No. of stages) 19 Press Down key Auto.C.t. (Control type) Auto/Manual 20 Press DOWN key 0.980Lg. PF limit – inductive (lagging PF). Range: 0.800 to 0.999 21 Press DOWN key 0.980Ld. PF limit – capacitive (leading PF). Range: 0.800 to 0.999 22 Press DOWN key 20.00o.n Relay on time. Range:4 to 99 seconds 23 Press DOWN key 20.00o.F Relay off time. Range:4 to 99 seconds 24 Press DOWN key 50.00t.d Discharge time. Range: 4 to 99 seconds 25 Press Down key 15.00t.A Average time. Range: 2 to 200 seconds 26 Press DOWN key 498.0o.U Over voltage. Range : 48 to 999KV 27 Press DOWN key 48.00uU Under voltage. Range:48 to 999KV 28 Press DOWN key 6.000oA Over current. Range: 0.050 to 99KA 29 Press DOWN key 0.200uA Under current. Range: 0.050 to 99KA 30 Press DOWN key 20.00O.H Over harmonics. Range: 1% to 100% 31 Press DOWN key 3.000Ad Alarm time delay Range: 3 to 99 seconds 32 Press DOWN key 1000.C1 Capacitor VAR value for C1. Page 2 of 5 PG/iPFC/V2/0114 33 Press RIGHT key to set the Capacitor VAR value for C1 1000.C1 First digit blinking can be edited using UP/DOWN key. 34 Press RIGHT key to accept the edited value for first digit. 1000.C1 Second digit blinking, can be edited using UP/DOWN key. Press RIGHT key to accept the edited value. Continue the same method till fourth digit. Range: 500VAR to 9999MVAR 35 Press RIGHT key 1000.C1 Decimal point blinking. Can be set at appropriate location using UP/DOWN key. Ascertain the correct scale (Kilo/Mega) is selected. Kilo/Mega is placed on the right hand side of the display as K/M. Press RIGHT key to accept the edited value. Eg: To set 11.00KVAR Set first four digits (1100) as explained above press UP/DOWN key to place decimal point at appropriate location. Use UP/DOWN KEY. Letter K/M will indicate the Kilo/Mega. 36 Press DOWN key 1000.C2 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C2 37 Press DOWN key 1000.C3 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C3 38 Press DOWN key 1000.C4 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C4 39 Press DOWN key 1000.C5 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C5 40 Press DOWN key 1000.C6 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C6 41 Press DOWN key 1000.C7 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C7 42 Press DOWN key 1000.C8 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C8 43 Press DOWN key 1000.C9 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C9 44 Press DOWN key 1000.C10 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C10 45 Press DOWN key 1000.C11 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C11 46 Press DOWN key 1000.C12 Follow the procedure as described in steps 32 to 34. Capacitor VAR value for C12 47 Press DOWN key dISA.An. 1st Analog input parameter 48 Press DOWN key 1200.An Range :0.001 to 9999M 49 Press DOWN key dISA.An. 2nd Analog input parameter 50 Press DOWN key 1200.An Range :0.001 to 9999M 51 Press DOWN key xxxx bA (baud rate).Communication speed. (9600 -default/factory set) Defines the baud rate. Option : 1200,2400, 4800, 9600, 19.20k 52 Press DOWN key 53 Press DOWN key 54 Press DOWN key EUEn.PA (Parity check) 1.000dE (Device ID) Internal communication error check EUEn (even)/odd(odd)/no(no parity) Comment: Can change the option using UP & DOWN keys. Defines the (ID) communications identification number. Option: 1-247 Reverse lock (blocks energy accumulation in case the CT polarity reverse. Option : NO/YES no rE Page 3 of 5 PG/iPFC/V2/0114 55 Press DOWN key Range:1000 -9999. Password user definable. Caution : If password other than the default or user defined is used, meter will reject programming. CAUTION: Password can only be reset and recalibrated at factory. 56 Press DOWN key 0.400St Starting current value to be displayed in the meter Range: (0.2 to 10 % of full scale) 57 Press DOWN key 58 Press RIGHT key to store the changes done S A V E “Y” blinking. Display returns to Run mode. If “n”(no) is selected then Meter enters into RUN mode without memorizing any edited Values in the setup Once the required parameter is programmed press the DOWN key continuously till it reaches SAVE page directly. 4.1 The List of parameters can be configured and the range is given below Sl.No. Parameter Default setup Range 1 Connection mode(ELEMNT) STAR STAR/ DELTA 2 PT Primary (PT.Prı) 415.0 100V- 999kV 3 PT Secondary (PT SEC) 415.0 50V - 550V 4 CT Primary (CT.Prı) 5.000 0.5A - 99kA 5 CT SECondary (CT SEC) 5.000 0.5A - 6A 6 VA selection (UA.SLEC) Arith (Arithmetic) 7 No.of Relays (nr) 12.000 8 Control type (C.t) Auto Arith (Arithmetic) / Vector/ Vec.H (vector harmonics) 1-12 Auto/Manual 9 PF lag(Lg) 0.980 0.800 to 0.999 10 PF lead(Ld) 0.980 0.800 to 0.999 11 Switch ON time(on) 20.00 4 to 99 seconds 12 Switch OFF time(oF) 20.00 4 to 99 seconds 13 Discharge time(t.d) 50.00 4 to 99 seconds 14 Average Time(t.A) 15.00 2 to 200 seconds 15 Over voltage(o.u) 498.0 48 to 999KV 16 Under voltage(uu) 48.00 48 to 999KV 17 Over current(o.A) 6.000 0.050 to 6A 18 Under current(u.A) 0.200 0.050 to 6A 19 Over Harmonics(O.H) 20.00 1 to 100% 3.000 3 to 99 seconds 20 Alarm delay (A.d) 21 Capacitance(C1) 1000.0 500 VAR to 9999 MVAR (default 1000 VAR = 1 kVAR) 22 Capacitance(C2) 1000.0 500 VAR to 9999 MVAR 23 Capacitance(C3) 1000.0 500 VAR to 9999 MVAR 24 Capacitance(C4) 1000.0 500 VAR to 9999 MVAR 25 Capacitance(C5) 1000.0 500 VAR to 9999 MVAR 26 Capacitance(C6) 1000.0 500 VAR to 9999 MVAR 27 Capacitance(C7) 1000.0 500 VAR to 9999 MVAR 28 Capacitance(C8) 1000.0 500 VAR to 9999 MVAR 29 Capacitance(C9) 1000.0 500 VAR to 9999 MVAR 30 Capacitance(C10) 1000.0 500 VAR to 9999 MVAR 31 Capacitance(C11) 1000.0 500 VAR to 9999 MVAR 32 Capacitance(C12) 1000.0 500 VAR to 9999 MVAR 33 Analog input disA Disable Analog input 34 Analog input full scale value 1200 0.001 to 9999M 35 Analog input disA Disable Analog input 36 Analog input full scale value 1200 0.001 to 9999M 37 Baud rate 9600 1200 to 19.2k 38 Parity Even Even/ Odd/ no 39 Device Id (dEV.Id) 1.000 1.000 to 247.0 40 Reverse lock(rEu.LOC) No Yes/no Page 4 of 5 PG/iPFC/V2/0114 41 Password (PASud) 1000 1000 to 9999 42 StArt.A (starting current) 0.400 0.2 to 10 % 5. Clearing the Integrator: To Clear parameters from the front panel, Press UP and DOWN Keys together, and 'CLEAr' (Clear) is shown on the display. Enter the Password (default password is 1000. Set up and clear has the same password) and it will display “CLr.I”. Press UP / DOWN Key for selecting CLr.I (Integ Clear). Once the parameter to be cleared is selected it will prompt to ‘y’ or ‘n’. Press UP and DOWN key for changing ‘y’ or ‘n’ and Press the RIGHT key to do the operation. 6. Enabling and disabling of Auto scrolling: Enabling auto scrolling: Press UP key continuously for 5 seconds or until display shows EnAbLE Auto.Sc for upward scrolling. Press Down key continuously for 5 seconds or until display shows EnAbLE SCROL for downward scrolling. Disabling auto scrolling: Press any key (RIGHT/UP/DOWN), display show dlSAbL Auto.Sc and returns to normal mode. 7. Manual Mode: Press UP and DOWN Keys together, and 'CLEAr' (Clear) is shown on the display. Enter the Password (default password is 1000. Set up and clear has the same password) and it will display “CLr.I”. Press DOWN Key and meter displays “Manual”. Once manual selected it will display C1 OFF or C1.On (depends on whether the capacitor is ON or OFF). Press RIGHT key to make it ON or OFF. Continue this for other no. of relays programmed. Once the required no. of relays are switched ON or OFF display will prompt to “CLEAr.”or Manual . When display prompts to CLEAr press DOWN key and ‘n’ will display and Press the RIGHT key to come out. 8. LED Indications: LED status Meaning LED status KILO – ON Kilo C3 – ON Capacitor Bank 3 ON / Relay 3 ON status MEGA – ON Mega C4 – ON Capacitor Bank 4 ON / Relay 4 ON status KILO & MEGA – ON Giga C5 – ON Capacitor Bank 5 ON / Relay 5 ON status KILO & MEGA – OFF Direct reading C6 – ON Capacitor Bank 6 ON / Relay 6 ON status Minus (-) ON Lag/Minus C7 – ON Capacitor Bank 7 ON / Relay 7 ON status Minus (-) OFF Lead/Plus C8 – ON Capacitor Bank 8 ON / Relay 8 ON status COM – ON – ON C1 – ON C2 – ON Meaning Communication ON C9 – ON Alarm relay ON C10 – ON Capacitor Bank 10 ON / Relay 10 ON status Capacitor Bank 1 ON / Relay 1 ON status C11 – ON Capacitor Bank 11 ON / Relay 11 ON status Capacitor Bank 2 ON / Relay 2 ON status C12 – ON Capacitor Bank 12 ON / Relay 12 ON status Capacitor Bank 9 ON / Relay 9 ON status 9. Display of Parameters: DISPLAY Meaning DISPLAY Meaning DISPLAY Meaning Average Power Factor Frequency VAr B Phase Total VAR Watts Total Under Voltage Voltage line to line Power Factor Over Voltage Voltage line to Neutral Power Factor R Phase Under Current Voltage RY Phase Power Factor Y Phase Over Current Voltage YB Phase Power Factor B Phase Over Compensation Voltage BR Phase VAr R Phase Under Compensation Current Average VAr Y Phase Reverse Amps Voltage R phase Current RPhase Over Harmonics Page 5 of 5 PG/iPFC/V2/0114
© Copyright 2026 Paperzz