BERKELEY® MS Stainless Steel Series 4” Submersible Pumps

BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
Precision-engineered,
high-quality, rugged Stainless
Steel Series Pumps deliver
efficient, depend­able performance
even in rough, aggressive water.
Heads to 1,950 feet and capacities
to 65 GPM. Built to deliver
long-term, trouble-free service.
Floating impeller design resists
sand and reduces sand locking.
These pumps feature the proven
SignaSealTM staging system.
Applications
■ W
ater
systems… for residential,
industrial, commercial, multiple
housing and farm use.
SPECIFICATIONS
Shell – Stainless steel
Diameter – 3-7/8"
Discharge – Stainless steel
Discharge Bearing – Nylatron®
Intermediate Bearing – (On larger
units) Polycarbonate, nitrile rubber
and stainless steel
Impellers – Acetal
Diffusers – Polycarbonate
Suction Caps – Polycarbonate with
stainless steel insert
Thrust Pads – Proprietary spec.
Shaft and Coupling – Stainless
steel
Intake – Stainless steel
Intake Screen – Polypropylene
Cable Guard – Stainless steel
Check Valve – Acetal✝
Agency Listings – CSA
Precision-
Feature
Proven Staging System – Our
proven SignaSeal staging system
incor­po­rates a harder-than-sand
ceramic wear surface that when
incorporated with our floating
impeller design, greatly reduces
problems with abrasives, sand
lock-up and running dry.
Discharge – Corrosion-resistant
300 grade stainless steel for
durability in aggressive water.
Large wrench flats for ease of
installation.
Discharge Bearing – Selflubricating Nylatron® bearing
resists wear from sand.
Intake – Corrosion-resistant 300
grade stainless steel for durability
in aggressive water.
Shaft – Positive drive from 7/16"
hex­agonal heavy-duty 300 grade
stainless steel.
Coupling – Stainless steel press
fit to pump shaft. Couples to all
standard NEMA motors.
Shell – Highest grade, heavywalled corrosion-resistant stainless steel. Threaded for easy
servicing.
Hardware – All screws, washers
and nuts are corrosion-resistant
300 grade stainless steel.
Check Valve✝ – Durable internal
spring-loaded check valve.
Cable Guard – Corrosion-resistant
stainless steel guard protects
motor leads. Tapered ends prevent
pump from catching on well.
Intake Screen – Corrosion-proof.
PENTEK® XE SeriesTM Motor –
2 and 3 wire NEMA standard all
stainless construction water-filled
motors.
✝ Except
where noted.
Nylatron is a registered trademark of Polymer Corp.
All other brand or product names are trademarks or registered marks of Pentair Ltd.
®
1
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
ORDERING INFORMATION
Assembled Pump Pump End Motor Control Box
Motor
CatalogLengthWeightCatalogLengthWeightCatalog WeightCatalog Weight
GPM Type HP Stgs. PH VoltNumberInches* Pounds*NumberInches* Pounds*Number Pounds*Number Pounds*
1/2 7 1115B10P4MS0512122-3/4 27-1/2 L10P4CMGS12-3/4 9 P42B0005A119
1/2 7 1230B10P4MS0522122-3/4 27-1/2 L10P4CMGS12-3/4 9 P42B0005A219
2 Wire 3/4 10 1 230 B10P4MS0722125-3/4 30-1/2 L10P4DMGS14-1/2 10 P42B0007A223
1 13 1230B10P4MS1022128-3/4 34-1/2 L10P4EMGS16-1/2 10-3/4 P42B0010A225
1-1/217 1230B10P4MS1522134-3/4 41-1/2 L10P4FMGS19-3/4 12-1/2 P42B0015A229
1/2 7 1115B10P4MS0513122-3/4 27-1/2 L10P4CMGS12-3/4 9 P43B0005A119 SMC-IR05114
1/2 7 1230B10P4MS0523122-3/4 27-1/2 L10P4CMGS12-3/4 9 P43B0005A218SMC-CR05214
3/4 10 1230B10P4MS0723125-3/4 30-1/2 L10P4DMGS14-1/2 10 P43B0007A221SMC-CR07214
1 13 1230B10P4MS1023128-3/4 34-1/2 L10P4EMGS16-1/2 10-3/4 P43B0010A223SMC-CR10214
1-1/217 1230B10P4MS1523133-1/2 41-1/2 L10P4FMGS19-3/4 12-1/2 P43B0015A227SMC-CR15217
10** 1-1/217 3230 L10P4FMGS19-3/4 12-1/2 P43B0015A323
1-1/217 3460 L10P4FMGS19-3/4 12-1/2 P43B0015A423
2 21 1230 L10P4GMGS22 13-3/4P43B0020A231SMC-CR20217
3 Wire
2 21 3230 L10P4GMGS22 13-3/4P43B0020A323
2 21 3460 L10P4GMGS22 13-3/4P43B0020A423
3 29 1230 L10P4GMGS22 16-3/4P43B0030A240SMC-CR30218
3 29 3230 L10P4HMGS28 16-3/4P43B0030A332
3 29 3460 L10P4HMGS28 16-3/4P43B0030A432
5 47 1230 L10P4JMGS43-1/2 25-1/2 P43B0050A270SMC-CR502112
5 47 3230 L10P4JMGS43-1/2 25-1/2 P43B0050A3
55
5 47 3460 L10P4JMGS43-1/2 25-1/2 P43B0050A455
1/2 5 1115B15P4MS0512122-1/4 27 L15P4CMGS12-1/4 9 P42B0005A119
1/2 5 1230B15P4MS0522122-1/4 27 L15P4CMGS12-1/4 9 P42B0005A219
7 1 230 B15P4MS0722125-3/4 31 L15P4DMGS14-1/2 10 P42B0007A223
2 Wire 3/4
1 9 1230B15P4MS1022129-1/4 35 L15P4EMGS16-3/4 11 P42B0010A225
1-1/212 1230B15P4MS1522135-1/4 43 L15P4FMGS20-1/4 13 P42B0015A229
1/2 5 1115B15P4MS0513122-1/4 27 L15P4CMGS12-1/4 9 P43B0005A119 SMC-IR05114
1/2 5 1230B15P4MS0523122-1/4 27 L15P4CMGS12-1/4 9 P43B0005A218SMC-CR05214
3/4 7 1230B15P4MS0723125-3/4 31 L15P4DMGS14-1/2 10 P43B0007A221SMC-CR07214
15** 1 9 1230B15P4MS1023129-1/4 35 L15P4EMGS16-3/4 11 P43B0010A223SMC-CR10214
1-1/212 1230B15P4MS1523133-3/4 41 L15P4FMGS20-1/4 13 P43B0015A227SMC-CR15217
1-1/212 3230 L15P4FMGS20-1/4 13 P43B0015A323
3 Wire 1-1/2 12 3 460
L15P4FMGS20-1/4 13 P43B0015A423
2 15 1230 L15P4GMGS23-1/2 15 P43B0020A231SMC-CR20217
2 15 3230 L15P4GMGS23-1/2 15 P43B0020A323
2 15 3460 L15P4GMGS23-1/2 15 P43B0020A423
3 22 1230 L15P4HMGS31-1/4 18 P43B0030A240SMC-CR30217
3 22 3230 L15P4HMGS31-1/4 18 P43B0030A332
3 22 3460 L15P4HMGS31-1/4 18 P43B0030A432
* Length and Weight are approximate.
** For 10 GPM, 15 GPM, and 20 GPM, discharge is 1-1/4" NPT.
***For 30 GPM and 50 GPM discharge is 2" NPT.
NOTE: On 2 HP and larger – Pump, Motor, Control Box or Magnetic Starter must be ordered separately.
✝ Check Valve not included on 5 HP, 7-1/2 HP and 10 HP models. Check valve not included on 50 GPM models.
TrimLineTM version maximum outside diameter 3-3/4". Standard version maximum outside diameter on all models is 3-7/8".
2
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
ORDERING INFORMATION
Assembled Pump Pump End Motor Control Box
Motor
CatalogLengthWeightCatalogLength WeightCatalog WeightCatalog Weight
GPM Type HP Stgs. PH VoltNumber
Inches* Pounds*Number Inches* Pounds*Number
Pounds*Number
Pounds*
3/4 5 1230 B20P4MS0722123-3/4 30 L20P4DMGS12-1/2 8-1/2 P42B0007A223
2 Wire 1
7 1 230 B20P4MS1022127-1/4 34 L20P4EMGS14-3/4 9-3/4 P42B0010A225
1-1/2 9 1230 B20P4MS1522132 39L20P4FMGS16-3/4 10-3/4 P42B0015A229
3/4 5 1230 B20P4MS0723123-3/4 30 L20P4DMGS12-1/2 8-1/2 P43B0007A223SMC-CR07215
1 7 1230 B20P4MS1023127-1/4 34 L20P4EMGS14-3/4 9-3/4 P43B0010A225SMC-CR10215
1-1/2 9 1230 B20P4MS1523130-1/2 39 L20P4FMGS16-3/4 10-3/4 P43B0015A229SMC-CR15217
1-1/2 9 3230 L20P4FMGS16-3/4 10-3/4 P43B0015A323
1-1/2 9 3460 L20P4FMGS16-3/4 10-3/4 P43B0015A423
2 12 1230 L20P4GMGS20-1/4 12-1/2 P43B0020A231SMC-CR20217
** 2 12 3230 L20P4GMGS20-1/4 12-1/2 P43B0020A332
20
2 12 3460 L20P4GMGS20-1/4 12-1/2 P43B0020A432
3 Wire 3 17 1 230
L20P4HMGS25-3/4 15 P43B0030A240SMC-CR30217
3 17 3230 L20P4HMGS25-3/4 15 P43B0030A3
32
3 17 3460 L20P4HMGS25-3/4 15 P43B0030A432
5 28 1230 L20P4JMGS38 21 P43B0050A270SMC-CR50218
5 28 3230 L20P4JMGS38 21 P43B0050A3
55
5 28 3460 L20P4JMGS38 21 P43B0050A455
7-1/240 3230 L20P4KMGS53-3/4 30 P43B0075A370
7-1/240 3460 L20P4KMGS53-3/4 30 P43B0075A470
10 54 3460 L20P4LMGS71 41 P43B0100A478
1 5 1230 B30P4MS1022126-1/2 35 L30P4EMGS14 9-3/4P42B0010A225
2 Wire
1-1/2 6 1 230 B30P4MS1522130-1/2 39 L30P4FMGS15-1/4 10-3/4 P42B0015A229
1 5 1230 B30P4MS1023126-1/2 35 L30P4EMGS14 10 P43B0010A225SMC-CR10215
1-1/2 6 1230 B30P4MS1523129 39L30P4FMGS15-1/4 11 P43B0015A229SMC-CR-15217
1-1/2 6 3230 L30P4FMGS15-1/4 11 P43B0015A323
1-1/2 6 3460 L30P4FMGS15-1/4 11 P43B0015A423
2 8 1230 L30P4GMGS18-1/4 12 P43B0020A231SMC-CR20217
2 8 3230 L30P4GMGS18-1/4 12 P43B0020A323
***
30 2 8 3460 L30P4GMGS18-1/4 12 P43B0020A423
3 Wire 3 12 1 230
L30P4HMGS24 15 P43B0030A240SMC-CR30217
3 12 3230 L30P4HMGS24 15 P43B0030A3
32
3 12 3460 L30P4HMGS24 15 P43B0030A432
5 20 1230 L30P4JMGS35-3/4 20 P43B0050A270SMC-CR50218
5 20 3230 L30P4JMGS35-3/4 20 P43B0050A355
5 20 3460 L30P4JMGS35-3/4 20 P43B0050A455
7-1/228 3230 L30P4KMGS50 27 P43B0075A370
7-1/228 3460 L30P4KMGS50 27 P43B0075A470
10 38 3460 L30P4LMGS65-1/2 35 P43B0100A470
* Length and Weight are approximate.
** For 10 GPM, 15 GPM, and 20 GPM, discharge is 1-1/4" NPT.
***For 30 GPM and 50 GPM discharge is 2" NPT.
NOTE: On 2 HP and larger – Pump, Motor, Control Box or Magnetic Starter must be ordered separately.
✝ Check Valve not included on 5 HP, 7-1/2 HP and 10 HP models. Check valve not included on 50 GPM models.
TrimLineTM version maximum outside diameter 3-3/4". Standard version maximum outside diameter on all models is 3-7/8".
3
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
ORDERING INFORMATION
Pump End Motor Control Box
MotorCatalogLength
WeightCatalog
WeightCatalog
Weight
GPM Type HP Stgs. PH VoltNumberInches*
Pounds*Number
Pounds*Number
Pounds*
2 Wire 1-1/2 4
1
230 L50P4FMGS15-1/4 10P42B0015A229
1-1/2 4
1
230 L50P4FMGS15-1/4 10P43B0015A227
SMC-CR1521 7
1-1/2 4
3
230 L50P4FMGS15-1/4 10P43B0015A323
1-1/2 4
3
460 L50P4FMGS15-1/4 10P43B0015A423
2 6
1
230 L50P4GMGS19-1/4 12P43B0020A231
SMC-CR2021 7
2 6
3
230 L50P4GMGS19-1/4 12P43B0020A327
2 6
3
460 L50P4GMGS19-1/4 12P43B0020A427
***
50 3 8
1
230 L50P4HMGS23-1/4 15 P43B0030A240
SMC-CR3021 7
3 Wire
3 8
3
230 L50P4HMGS23-1/4 15 P43B0030A332
3 8
3
460 L50P4HMGS23-1/4 15 P43B0030A432
5 13 1230
L50P4JMGS33-1/2 20P43B0050A270
SMC-CR50218
5 13 3230
L50P4JMGS33-1/2 20P43B0050A355
L50P4JMGS33-1/2 20P43B0050A455
5 13 3460
7-1/220 3 230L50P4KMGS47-1/2 25 P43B0075A370
7-1/220 3 460L50P4KMGS47-1/2 25 P43B0075A470
L50P4LMGS57-3/4 35P43B0100A470
1025 3460
* Length and Weight are approximate.
** For 10 GPM, 15 GPM, and 20 GPM, discharge is 1-1/4" NPT.
***For 30 GPM and 50 GPM discharge is 2" NPT.
NOTE: Pump, Motor, Control Box or Magnetic Starter must be ordered separately.
Check valve not included on 50 GPM models.
4
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
OUTLINE DIMENSIONS – 10,15, and 20 GPM
OUTLINE DIMENSIONS – 30 and 50 GPM
3-7/8
Pump End
3-7/8
Discharge
1-1/4" NPT
1-1/4" NPT
1-1/4" NPT
30 GPM
50 GPM
Pump End
10 GPM
15 GPM
20 GPM
Discharge
Pump diameter is
3-7/8". For lengths, refer
to Ordering Information
tables.
Assembled Pump
For lengths, refer to
Ordering Information
tables.
2" NPT
2" NPT
Dimensions (in inches) are for estimating purposes only.
Dimensions (in inches) are for estimating purposes only.
PUMP PERFORMANCE – 10 GPM
PUMP PERFORMANCE – 15 GPM
CAPACITY LITERS PER MINUTE
0
10
20
30
40
50
CAPACITY LITERS PER MINUTE
60
0
70
2000
20
30
5H
50
60
70
80
90
240
700
P
3H
P
500
1600
40
800
600
1800
10
200
P
300
800
2 HP
600
1-1/2 H
400
3/4 HP
200
P
2H
P
400
1-1/
300
1 HP
2 HP
120
80
3/4 H
P
1 HP
200
1/2 HP
100
1/2 HP
40
100
200
0
160
500
TOTAL HEAD IN METERS
3H
1000
TOTAL HEAD IN FEET
TOTAL HEAD IN FEET
400
1200
TOTAL HEAD IN METERS
600
1400
5
10
15
CAPACITY GALLONS PER MINUTE
20
0
0
5
10
15
20
CAPACITY GALLONS PER MINUTE
25
0
Tested and rated in accordance with Water Systems Council standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
5
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
PUMP PERFORMANCE – 20 GPM
PUMP PERFORMANCE – 30 GPM
CAPACITY LITERS PER MINUTE
0
25
50
75
100
CAPACITY LITERS PER MINUTE
0
125
2000
80
120
160
1400
600
10 H
40
10 HP
P
400
1800
1200
1600
1200
5 HP
300
800
200
3 HP
600
TOTAL HEAD IN FEET
TOTAL HEAD IN FEET
400
1000
7-1/2 HP
1000
HP
TOTAL HEAD IN METERS
7-1/2
1400
800
5 HP
200
600
3 HP
400
2 HP
400
100
1 HP
3/4 HP
0
100
2 HP
1-1/2 HP
200
300
TOTAL HEAD IN METERS
500
1-1/2 HP
200
1 HP
5
10
15
20
25
30
35
0
0
CAPACITY GALLONS PER MINUTE
10
20
30
40
CAPACITY GALLONS PER MINUTE
50
0
Pump Performance – 50 GPM
CAPACITY LITERS PER MINUTE
0
50
100
150
200
250
300
800
240
10 H
P
700
200
7-1/
TOTAL HEAD IN FEET
160
500
400
5 HP
120
3 HP
80
300
200
TOTAL HEAD IN METERS
2 HP
600
2 HP
40
1-1/2HP
100
0
10
20
30
40
50
60
70
80
0
CAPACITY GALLONS PER MINUTE
6
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
10 Gallons per Minute
PUMP PERFORMANCe (Capacity in Gallons Per Minute)
Shut-Off
Pumping Depth in Feet
Head
HPPSI
20 40 60 80 1001251501752002503003504004505005506006507007508008509009501000FeetPSI
0 — — 14.1 13.5 12.8 12.0 10.8 9.5 7.4 4.7
20 14.0 13.3 12.7 12.0 11.0 9.6 7.8 5.2 30 13.2 12.6 11.8 10.9 9.8 8.0 5.5 1/2
255110
40 12.4 11.7 10.8 9.7 8.2 8.8 2.0
50 11.5 10.5 9.4 7.8 5.8 2.2
60 10.4 9.2 7.5 5.4 2.8
0 — — — 14.8 14.4 13.8 13.0 12.0 11.0 8.4 4.7
20 — 14.7 14.3 13.7 13.0 12.2 11.2 9.9 8.6 5.0
30 14.414.213.713.012.311.210.0 8.8 7.2 3.0
3/4
340147
40 14.2 13.5 12.9 12.1 11.3 10.2 8.9 7.4 5.3
50 13.4 12.7 12.0 11.0 10.2 8.9 7.4 5.5 3.2
60 12.6 11.9 11.0 10.0 9.1 7.5 5.7 4.4
0 — — — — 14.9 14.4 13.8 13.3 12.8 11.5 10.1 8.2 5.8 2.1
20 — — 14.7 14.4 14.0 13.4 12.9 12.3 11.7 10.2 8.3 6.0 2.6
30 — 14.7 14.4 13.8 13.4 12.9 12.3 11.7 11.0 9.4 7.4 4.6
1
467202
40 14.6 14.2 13.8 13.3 13.0 12.5 11.8 11.1 10.3 8.5 6.2 3.0
50 14.1 13.7 13.3 12.9 12.4 11.8 11.1 10.2 9.5 7.4 4.8
60 13.7 13.2 12.8 12.4 11.9 11.2 10.3 9.5 8.7 6.3 3.2
0 — — — — — — 14.7 14.4 14.0 13.2 12.2 11.2 10.1 8.6 7.1 5.2 2.5
20 — — — — 14.8 14.4 14.0 13.6 13.2 12.4 11.3 10.2 8.7 7.3 5.3 2.8
30 — — — 14.7 14.4 14.0 13.6 13.2 12.8 11.9 10.7 9.6 8.1 6.4 4.4
1-1/2
636275
40 — 15.0 14.7 14.4 14.1 13.7 13.3 12.8 12.4 11.4 10.2 8.9 7.3 5.5 3.0
50 14.9 14.6 14.3 14.0 13.6 13.2 12.8 12.4 12.0 10.8 9.7 8.2 6.5 4.5
60 14.5 14.3 14.0 13.6 13.3 12.8 12.4 12.0 11.5 10.2 9.0 7.5 5.6 3.3
0 — — — — — — — 14.9 14.6 14.0 13.3 12.7 12.0 11.1 10.2 9.2 8.0 6.6 5.1 3.1
20 — — — — — 14.9 14.6 14.4 14.0 13.4 12.7 12.0 11.1 10.2 9.2 8.0 6.6 5.1 3.1
30 — — — — 15.0 14.7 14.4 14.0 13.8 13.1 12.4 11.7 10.7 9.8 8.8 7.5 6.1 4.5 2.0
2
806349
40 — — — 14.9 14.6 14.4 14.2 13.8 13.3 12.8 12.1 11.3 10.2 9.2 8.0 6.6 5.1 3.1
50 — — 14.9 14.6 14.4 14.1 13.8 13.4 13.1 12.4 11.6 10.8 9.8 8.8 7.6 6.1 4.7 2.2
60 15.1 14.9 14.6 14.4 14.1 13.8 13.4 13.1 12.8 12.1 11.3 10.3 9.5 8.3 6.9 5.3 3.7
0——————————14.7
14.3
13.8
13.3
12.8
12.3
11.8
11.0
10.29.58.77.66.45.34.1
20—————————14.7
14.3
13.8
13.3
12.8
12.3
11.8
11.0
10.2 9.58.77.66.45.34.1
30———————14.7
15.0
14.5
14.1
13.6
13.1
12.6
12.1
11.4
10.7
10.0 9.28.27.16.04.93.3
3
1100476
40———————15.0
14.7
14.3
13.8
13.3
12.8
12.3
11.8
11.0
10.2 9.5 8.77.66.45.34.1
50 — — — — — — 15.0 14.8 14.6 14.1 13.7 13.2 12.7 12.2 11.7 10.9 10.1 9.4 8.6 7.5 6.2 5.0 3.9
60 — — — — — 15.0 14.8 14.6 14.4 13.9 13.4 12.9 12.4 11.9 11.2 10.4 9.7 8.8 7.9 6.6 5.5 4.3
Shut-Off
Pumping Depth in Feet
Head
HPPSI
Feet
PSI
200 300 400 500 600 700 800 900 1000 11001200 13001400 1500 16001700
0 —
—
— 14.614.213.512.912.311.6 10.8 9.9 8.9 7.7 6.3 4.9
20 —
— 15.0 14.513.913.312.712.111.2 10.3 9.4 8.5 7.1 5.6 4.1
30 —
— 14.9 14.313.813.112.511.911.1 10.2 9.2 8.2 6.7 5.2 3.71824
745
5
40 —
— 14.7 14.213.512.912.311.610.8 9.9 8.9 7.7 6.3 4.9
50 —
— 14.6 14.113.412.812.211.510.7 9.8 8.8 7.5 6.1 4.7
60 — 15.0 14.5 13.913.312.712.111.210.3 9.4 8.5 7.1 5.6 4.1
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when
failure occurs under these conditions. Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
7
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
15 Gallons per Minute
PUMP PERFORMANCe (Capacity in Gallons Per Minute)
Shut-Off
Pumping Depth in Feet
Head
HP PSI 20 40 60 80 100125150175200250300350 400 450 500 550 600 650 700 750 800 FeetPSI
0 —
— 20.0 18.7 16.9 13.1 7.4 20 19.7 18.3 16.3 13.0 8.8 1/2
30
18.0
15.6
12.4 7.9 2.0
17576
40 15.2 11.9 7.0 50 11.2 5.8 60 4.8
0 — — 21.220.219.317.816.013.2 9.6
2020.9 19.919.017.716.413.710.0 4.9
3/4 30 19.8 18.8 17.6 16.1 14.0 10.7 5.5 245106
40 18.6 17.5 15.9 13.5 10.9 6.0 50 17.2 15.4 13.1 10.0 6.4 60 15.0 12.7 9.7 5.5
0 — — — — 20.419.418.417.215.510.3 2.7
20 — 20.920.219.318.717.515.813.410.9 3.2
3020.8 20.019.118.517.616.013.711.1 7.5
1
318138
40 19.8 19.0 18.3 17.4 16.2 13.9 11.3 8.1 3.7
50 18.9 18.2 17.1 15.8 14.0 11.4 8.2 4.0 0
60 18.0 17.0 15.6 13.7 11.7 8.4 4.4 0 —
— — — — 20.5 19.9 19.3 18.4 16.4 13.1 8.3 2.8
20 —
— 21.2 20.5 20.0 19.3 18.6 17.6 16.5 13.5 9.1 3.2
30 — 21.1 20.3 19.9 19.3 18.7 17.7 16.6 15.4 11.7 6.3 1-1/2
420182
40 21.0 20.2 19.8 19.2 18.7 17.9 16.7 15.5 13.7 9.4 3.6
50 20.2 19.7 19.2 18.6 18.0 16.8 15.6 13.8 11.9 6.7 60 19.6 19.0 18.5 17.7 16.9 15.7 13.9 12.0 9.7 3.8
0 —
— — — — — 20.7 20.2 19.6 18.3 16.9 14.4 11.6 7.4 2.7
20 — — — 21.220.920.219.719.118.417.014.711.8 7.8 3.2
30 — — 21.220.820.319.719.118.517.916.113.510.2 5.5 525227
2
40 — 21.120.620.219.819.218.617.917.114.912.0 8.1 3.4
5021.1 20.620.119.719.218.617.917.116.213.610.8 6.0 60 20.5 20.1 19.6 19.1 18.7 18.0 17.2 16.2 15.1 12.2 8.6 3.7
0 — — — — — — — — 21.020.219.518.717.816.615.013.010.8 8.0 4.9 1.6
20 — — — — — — 21.120.820.319.518.817.916.715.113.211.1 8.3 5.2 1.9
30 — — — — — 21.220.820.319.919.218.317.416.114.312.210.4 7.0 3.5 3.6
3
770333
40 — — — 21.621.220.920.419.919.618.818.016.815.213.411.2 8.4 5.4 2.1
50 — — 21.621.120.920.420.019.719.218.417.516.214.412.310.5 7.1 3.8
60 — 21.421.120.820.520.019.719.318.918.016.915.313.511.4 8.8 5.5 CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when
failure occurs under these conditions.
Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a PRO-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
8
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
20 Gallons per Minute
PUMP PERFORMANCe (Capacity in Gallons Per Minute)
Shut-Off
Pumping Depth in Feet
Head
HPPSI
20 40 60 80 1001251501752002503003504004505005506006507007508008509009501000FeetPSI
0————23.5
19.0
13.7 20 — 25.822.518.514.5 3.4
30 25.222.018.313.9 4.5
3/4
18078
40
21.3
17.6
13.0 3.0
17.2
11.4 50
60
10.2
0 — — — — — 25.322.418.815.5
20
—
—
—
25.1
22.8
19.5
16.1
10.1
30 — — 24.922.519.816.510.6
1
251109
40 — 24.522.019.416.811.6 2.6
50 24.221.519.016.312.5 3.3
60 21.318.616.011.1 3.7
5.4
0 — — — — — — 26.424.021.616.4 20 — — — — 26.824.422.019.516.8 6.8
30 — — — 26.524.722.219.617.113.9
323140
1-1/2
40 — — 26.224.322.319.817.314.2 8.0
50 — 26.024.122.120.017.514.5 8.3
60 25.6 23.9 21.9 19.8 17.5 14.8 9.1 2.2
20.2
16.2 8.5
0—————————23.2
24.9
23.4
20.6
16.7 9.5
20——————26.1
30 — — — — — 26.225.023.522.119.113.8 4.8
2
420275
40 — — — — 26.425.123.722.220.817.210.1
50 — — — 26.125.123.822.320.919.314.0 5.7
60 — — 26.025.023.922.421.019.417.310.8
23.5
21.3
19.1
16.0
11.3 3.6
0——————————25.3
23.6
21.6
19.3
16.1
12.0 5.0
20—————————25.4
24.8
22.7
20.6
18.1
14.5 9.0
30————————26.6
3
605349
40———————26.7
25.5
23.8
21.7
19.6
16.8
12.5 5.3
25.6
24.9
22.8
20.8
18.5
15.0 9.5
50——————26.7
60 — — — — — 26.825.724.923.921.819.816.912.7 5.6
0—————————————26.5
25.2
24.0
22.8
21.5
20.2
18.9
17.0
14.3
11.06.8
25.3
24.1
22.9
21.6
20.3
19.0
17.3
14.0
11.2 7.3
20————————————26.6
24.9
23.5
22.2
21.0
19.9
18.2
16.2
13.3 9.5 5.2
30————————————26.0
5
1005476
40———————————26.7
25.4
24.2
22.9
21.7
20.4
19.1
17.5
14.4
11.5 7.7 3.1
50————— — — — — — — 26.0 25.0 23.6 22.3 21.1 20.0 18.4 16.3 13.5 9.9 5.7
60——————————26.8
25.5
24.3
23.0
21.8
20.5
19.2
17.7
14.9
12.0 8.0 3.7
Shut-Off
Pumping Depth in Feet
HPPSI
Head
200300400500600 700800900100011001200130014001500
1600
Feet
PSI
0
20
30
7-1/2
40
50
60
0
20
30
10
40
50
60
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
26.9
—
—
—
—
—
—
—
26.7
26.5
26.3
25.7
25.5
—
—
—
—
—
—
25.7
24.3
23.1
21.5
19.9
16.4
11.3 4.1
25.3
23.7
22.3
20.8
18.9
14.7 8.5 25.1
23.5
22.1
20.6
18.3
13.4 7.0
1450628
24.7
23.3
21.7
20.2
17.3
12.1 5.3
24.5
22.7
21.3
19.7
16.0
10.6 3.6
24.3
22.5
21.0
19.3
15.1 9.5 —
26.8 25.7 24.7 23.7 22.6 21.6 20.7 19.5 17.1
— 26.4 25.3 24.4 23.3 22.1 21.3 20.1 18.516.0
— 26.2 25.0 24.1 23.0 21.921.0 19.9 18.015.0
1950844
— 25.7 24.9 24.0 22.8 21.7 20.8 19.7 17.614.7
26.725.5 24.7 23.6 22.5 21.5 20.6 19.4 17.014.0
26.425.3 24.4 23.3 22.2 21.3 20.2 18.5 16.112.5
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when
failure occurs under these conditions. Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
9
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
30 Gallons per Minute
GALLONS PER MINUTE
PUMP PERFORMANCe (Capacity in Gallons Per Minute)
Pumping Depth in FeetShut-Off
Head
HPPSI
20 40 60 80 100125 150 175200 250300350400450500550600650700FeetPSI
0
— — 40.9 39.1 36.8 32.5 26.0 8.0
20 40.4 38.836.032.427.713.3
30
38.0
35.3
31.7
26.3
14.3
17576
1
40 35.0 31.425.912.1
50 30.2 24.0 3.0
6021.9
0 — — — 39.937.534.1 30.9 26.917.0
20 41.2 39.136.534.031.527.8 21.5
30
38.9
36.1
33.8
31.0
27.9
21.8
21091
1-1/2
40 36.0 33.530.827.720.2
50 32.9 30.126.821.5
60 29.5 25.918.1
0 — — — — 40.538.8 36.8 34.731.6 23.7
20 — 41.340.138.737.134.9 32.1 29.024.8
30
41.2
40.0
38.5
37.0
35.0
32.2
29.1
24.9
15.2
280121
2
40 39.9 38.336.634.832.729.8 25.1 16.1
50 38.0 36.334.532.130.025.3 17.5
60 36.0 34.031.929.126.018.0
0 — — — — — 41.6 40.1 39.638.2 35.532.027.3
20 — — — 41.541.039.8 38.5 37.135.7 32.128.018.5
30
—
—
41.3
40.6
39.9
38.7
37.2
35.8
34.2
30.3
24.9 6.0
420182
3
40 — 41.240.439.738.837.3 35.9 34.532.6 28.319.9
50 41.1 40.339.538.537.436.0 34.6 32.731.0 25.2 9.5
60 40.2 39.338.337.236.134.7 32.8 31.028.5 20.5
0 — — — — — — — — 42.040.739.238.036.034.231.929.226.020.0
20 — — — — — — 42.041.340.839.338.236.234.432.430.026.121.5
30 — — — — — 42.141.440.840.138.737.035.133.131.126.024.116.0
705305
5
40 — — — — 42.141.540.940.239.337.936.134.332.029.426.220.4
50 — — — 42.041.541.240.239.538.837.135.433.231.228.824.516.0
60 — — 42.041.441.140.339.838.938.136.234.232.130.026.722.0
Shut-Off
Pumping Depth in Feet
Head
HPPSI
200 300 400 500 600 700 800 900 10001100 120013001400Feet PSI
0 — — 40.4 37.6 34.832.0 28.1 20.0
20 — 42.0 39.3 36.5 33.830.5 25.5 13.8
30
—
41.3
38.6
35.8
33.1
29.8
23.3 6.5
7-1/2
975422
40 — 40.7 38.1 35.6 32.629.3 21.7
50 — 40.1 37.3 34.6 31.727.4 19.3
60 42.039.4 36.5 33.7 30.725.1 13.9
0 — — — 41.3 39.537.335.133.130.427.1 22.511.9
20 — — — 40.5 38.636.434.531.829.225.3 18.7
30 — — 42.040.1 43.035.733.731.328.424.2 16.3
10
1345582
40 — — 41.639.7 37.735.533.530.927.723.4 14.4
50 — — 41.039.3 37.134.932.830.226.721.7 7.7
60 — — 40.638.7 36.534.532.329.525.720.1 5.0
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when
failure occurs under these conditions. Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
10
CB5625WS
BERKELEY® MS Stainless Steel Series
4” Submersible Pumps — 10, 15, 20, 30 and 50 GPM
50 Gallons per Minute
PUMP PERFORMANCe (Capacity in Gallons Per Minute)
Pumping Depth in Feet
Shut-Off Head
HP PSI 20 40 60 80 100125150175200250300350450550650700Feet PSI
0
—
—
— 58.2 49.3 33.5
20 — 55.946.5 32.5
30
54.8
45.0
30.0
145 63
1-1/2
40 43.326.9
50 21.9
60
0 — — — 63.357.047.833.9
20 — 62.255.146.837.113.0
30
61.1
53.6
46.0
34.3
14.1
18078
2
40 52.845.032.511.0 50 42.7 27.9
60 25.2
0 — — — — 64.559.452.545.033.8
20 — — 63.759.053.546.536.218.2
30
—
62.9
58.1
53.0
47.0
37.0
20.5
235102
3
40 62.557.652.046.238.822.1
50 56.551.044.736.222.8
60 50.0 43.734.0 20.5
0 — — — — — — 65.963.259.951.941.922.5
20 — — — — — 63.560.856.152.442.524.9
30 — — — — 63.860.956.953.047.935.512.9
385166
5
40 — — 65.563.261.057.053.248.043.527.0
50 — 65.163.060.857.153.348.143.636.414.2
60 64.962.460.056.953.748.744.137.528.0
0—————————66.0
61.0
55.3
43.1
20.0
20————————64.8
61.1
56.0
50.0
34.9
30 — — — — — — — 64.963.358.753.247.228.8
595257
7-1/2
40 — — — — — — 65.063.661.756.250.944.122.0
50 — — — — — 65.163.761.858.953.947.541.013.2
60 — — — — 65.263.861.959.056.551.144.936.0
0——————————65.0
62.1
54.2
44.7
29.0
15.2
20—————————65.5
62.5
59.1
50.1
39.2
17.1
30————————66.9
64.1
61.2
56.9
47.5
35.0
10.5
745322
10
40 — — — — — — — 67.065.863.059.354.945.230.5
50 — — — — — — 67.165.964.261.557.253.042.925.0
60 — — — — — 67.266.064.363.259.955.051.040.619.7
CAUTION: DO NOT use pump at flow rates indicated by the symbol ‘—’. To do so can cause premature failure of unit. Pump warranty void when
failure occurs under these conditions.
Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a
75 PSI relief valve. Relief valve must be capable of relieving entire flow of pump at relief pressure.
11
CB5625WS
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.berkeleypumps.COM PH: 888-782-7483 ORDERS FAX: 800-426-9446
Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
© 2013 Pentair Ltd. All Rights Reserved.
CB5625WS (12/28/12)