Design Solutions 10’ x 12’ Private Office with dimming ballasts (2) 2x2 2T5HO without task lighting Project Summary LPD Area Summary: Label Room Area 120 Total Watts 110 LPD 0.95 Calculation Summary: Label Avg. Ambient - 30” AFF Desktop Grid 12’ Wall 10’ Wall CalcType Illuminance Illuminance Illuminance Illuminance Units fc fc fc fc Average 30 34 16 19 Max 37 37 21 40 Min 22 28 9 8 Avg/Min 1.4 1.2 1.8 2.4 Max/Min 1.7 1.3 2.3 5.0 Luminaire Schedule: Symbol Qty 2 Description Lumens Per Lamp or LED Fixture HPR-X-2x2-2T5HO-DCO 1750 Luminaire Watts 57 Lumens Per Watt** 61 BF LDD LLD LLF 1.00 0.90 0.93 0.84 ** Lumens/watt for fluorescent fixtures based on lamp/ballast system. T5HO Lamp: Osram - FP24/835/HO/ECO T5HO Ballast: Advance - Mark 10 Powerline IEZ-2S24-D Project Description: Room Size: 10’ x 12’ Ceiling Height: 9’ Room Reflectances: 80/50/20 10’ 12’ Wall 10’ Workplane Grid Desktop Grid (Ambient Only) (Ambient Only) 22 26 29 31 31 29 26 22 24 28 32 34 34 32 28 24 25 29 33 36 36 33 30 25 26 30 34 36 36 34 30 26 26 30 34 36 37 34 31 26 26 30 34 36 37 34 31 26 26 30 34 36 36 34 30 26 25 29 33 36 36 33 30 25 24 28 32 34 34 32 28 24 22 26 29 31 31 29 26 22 34 35 36 37 36 36 34 33 30 28 12’ 10’ Wall 32 34 36 36 37 37 36 34 33 31 28 32 34 36 36 37 37 36 34 33 31 29 32 34 36 36 37 37 36 34 33 31 29 34 36 36 37 37 36 34 33 31 28 Finelite, Inc. • 30500 Whipple Rd • Union City, CA 94587-1530 • 510-441-1100 • Fax: 510-441-1510 • www.finelite.com