3 1/2 digit 2-wire dc panel meter - M

43AL
Digital Panel Meters 43 Series
3 1/2 DIGIT 2-WIRE DC PANEL METER
43AL
MODEL
MODEL & SUFFIX CODE SELECTION
43AL
MODEL
INPUT: 4 – 20mA DC
Functions & Features
•Small size, 3 1/2 digit DC meter
•No external power source needed
•CE marking
•UL approval
ORDERING INFORMATION
Specify code number and variables. If the display scale
is not specified at the time of ordering, the unit will be
shipped with the default range 0 – 1999.
• Code number (e.g. 43AL)
•Display range (e.g. 00.0 – 100.0; including decimal point)
‘000’ (not including decimal point) is displayed for zero display.
Factory default for non-specified is ‘000 − 1999’ without
decimal point.
GENERAL SPECIFICATIONS
Construction: Panel flush mounting
Connection: Terminal block
Housing material: Fame-resistant resin (black)
Input configuration: Dual-slope integration
Scaling: Analog scaling; potentiometer on the top
DISPLAY
LED: 10.16 mm (.4”) 7-segment, red
Number of display digits: 3 1/2
Maximum display range: 1999
Scaling factor for process meter
Zero: ±200 counts
Span: 100 to 1999 counts
Decimal point position: 3 positions selectable with internal DIP SW behind the cover
Polarity sign: Minus (–) sign added automatically according to the computation result
Read rate: Approx. 2.5/s
Over-range warning: The MSD shows ‘1’ with all other
digits OFF with 1999 or greater input
Specifications are subject to change without notice.
INPUT
■ DC CURRENT: 4 – 20mA DC
Voltage drop*: Approx. 5.0V with 4mA; approx. 5.3V with
20mA
*The minimum required supply voltage to the 2-wire
transmitter added with the indicator’s voltage drop at the
maximum input current must be within the output voltage
range of the 2-wire transmitter’s excitation supply.
INSTALLATION
Operating temperature: 0 to 50°C (32 to 122°F)
Operating humidity: 35 to 85% RH (non-condensing)
Mounting:
Panel flush mounting
Dimensions: W48×H24×D40 mm (1.89”×0.94”×1.57”)
Weight:
30 g (1.1 oz)
PERFORMANCE
in percentage of reading
Accuracy: ±(0.1% of FS + 1 digit)
Temp. coefficient: ±0.3 digit/°C (±0.17 digit/°F)
Dielectric strength: 500V AC @1 minute
(input [LO] to grounding [E] terminal)
STANDARDS & APPROVALS
EU conformity: EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
Approval: UL (UL 508)
ES-9423 Rev.8
P. 1 / 2
43AL
DECIMAL POINT POSITION
EXTERNAL DIMENSIONS unit: mm (inch)
Remove the front acrylic cover and set the DIP SW located
below each digit.
45 (1.77)
21.8 (.86)
4.3 (.17)
O
N
1
O
N
40 (1.57)
O
N
2
27.3 (1.07)
3
5 (.20)
TOP VIEW
24 (.94)
Full-Scale Range Setting
Offset Setting
48 (1.89)
3
CONNECTION DIAGRAM
INPUT
MOUNTING REQUIREMENTS mm (inch)
HI(+) 1
LO(–) 2
GROUNDING E 3
Just insert the meter body (snap-in method).
■ PANEL CUTOUT
+0.6 (1.80)
45 –0 (1.77)
+0.3 (0.89)
–0 (0.87)
35 (1.38) min.
2
22.2
1
65 (2.56) min.
Panel Thickness: 0.8 – 3.5 mm (0.03 – 0.14 in.)
ES-9423 Rev.8