A W o r l d o f C o m p e t e n c e DRYER SERIES FOR ON-PREMISE LAUNDRY APPLICATIONS CAPACITIES 25–75 POUNDS T H E U LT I M AT E D R Y I N G M A C H I N E ™ GIVE US YOUR TOUGHEST JOB. Affordable Quality: For more than 50 years CISSELL has been a leader in the design and manufacture of products for the laundry and dry cleaning industry. In the CISSELL on-premise laundry line of standard and stack dryers, we’ve combined our unparalleled experience with years of extensive research to create the perfect balance of quality and affordability. DURABLE CONSTRUCTION • Stainless Steel Door – Standard Our dryers are incorporated with only the finest quality materials right down to the loading door and hinges! Constructed from high-grade steel, our heavy-duty door and hinges will stand up to the toughest laundry conditions time and time again. In addition, the circular door glassis sealed with a 7/8” rubber gasket to secure it in place while providing greater strength and rigidity. The result: A series of gas, steam and electric dryers with various capacities, which meet the needs of virtually every on-premise laundry facility. Whatever your needs, you can count on CISSELL for the highest quality products that stand up to your toughest demands. CISSELL is so confident in the performance and construction of our products that we back every dryer with a 3 year warranty* from the date of original sale, covering any part of the dryer which fails as a result of a defect on material or workmanship. *Parts only, labor not included. • Lint Compartment The fine mesh lint screen cleans itself automatically by depositing lint into a large storage area for easy removal. Therefore, the most efficient drying is achieved while eliminating the need to manually clean the filter after each use. • All Belt Drive System Our dryers are constructed with a self-adjusting tension idler, metal pulleys and sealed bearings for quiet operation and low maintenance. • Galvanized Steel Cylinder Our cylinders are constructed of galvanized steel to ensure a long life. Optionally available in stainless steel. See CISSELL warranty for specifics. 50 & 75 LB. DRUM SHOWN T H E U LT I M AT E D R Y I N G M A C H I N E ™ THE IDEAL COMBINATION OF EFFICIENCY AND DURABILITY. Only from CISSELL: CONTROLS AND FEATURES Nobody else gives you • Control Units Our Microprocessor control is state of the art. Computerized models feature 5 preset automatic drying cycles with an option to further customize. ➧ Anti-Wrinkle Safety Tumble — if door is not opened at end of cycle, dryer tumbles to remove excess heat, preventing unnecessary wrinkling. ➧ Basket RPM Display — push and hold the start button and it displays RPM to let maintenance workers determine when belts need tightening. so many advantages with so much affordability. Our manual dual timer control models allow operators to easily set both drying time and cool-down time. Only CISSELL puts it all together in our on-premise laundry line... Call for a • Airflow* Fabrics receive the most concentrated drying possible with minimum energy consumption, because the concentrated airflow pattern and sealed cylinder rims ensure that the maximum amount of warm air enters the cylinder and passes through the clothes. demonstration or *For models CHD–25, CHD–30, CHD–30 Stack and CHD–35 www.cissellmfg.com • ➧ ➧ ➧ ➧ ➧ ➧ Additional Features Integrated motor overload protection Solid steel cap over top of dryer Embossed steel cabinet for easy cleaning All major components are easily accessible High temperature limit control Superior exterior finish T H E U LT I M AT E D R Y I N G M A C H I N E ™ more information today, or visit our website at S P E C I F I C A T I O N S CHD–25 CHD–30 CHD–30 Stack CHD–35 CHD–50 CHD–75 HD–75 Stack Width Depth Height Cyl. Depth Cyl. Diameter Cyl. Volume 28” (711 mm) 38-7/8” (987 mm) 63-7/8” (1622 mm)* 24” (610 mm) 26-1/2” (673 mm) 7.66 cu. ft. (217 liters) 28” (711 mm) 44-7/8” (1140 mm) 63-7/8” (1622 mm)* 30” (762 mm) 26-1/2” (673 mm) 9.57 cu. ft. (271 liters) 31-1/2” (800 mm) 42-7/8” (1089 mm) 76-1/4” (1937 mm) 26” (660 mm) 30” (762 mm) 10.63 cu. ft. (301 liters) 31-1/2” (800 mm) 44-7/8” (1140 mm) 63-7/8” (1622 mm)* 30” (762 mm) 30” (762 mm) 12.27 cu. ft. (347 liters) 38-5/8” (981mm) 47” (1194 mm) 76-5/8” (1946 mm) 30” (762 mm) 37” (940 mm) 18.67 cu. ft. (528 liter) 38-5/8” (981mm) 53” (1346 mm) 76-5/8” (1946 mm) 36” (914 mm) 37” (940 mm) 22.4 cu. ft. (634 liter) 54” (1372 mm) 63-1/2” (1613 mm) 87-1/2” (2223 mm) 36” (914 mm) 36” (914 mm) 21.2 cu. ft. (1046 liter) Dry Capacity Filling Ratios 25 lb. (11.3 kg) (20:1 = 10.9 kg) (25:1 = 8.7 kg) 60 Hz: 450 CFM (212 liters/sec.) 50 Hz: 410 CFM 30 lb. (13.6 kg) (20:1 = 13.6 kg) (25:1 = 10.8 kg) 60 Hz: 450 CFM (212 liters/sec.) 50 Hz: 410 CFM 2 x 30 lb. (13.6 kg) (20:1 = 15.1 kg) (25:1 = 12.0 kg) 60 Hz: 350 CFM x 2 165 liters/sec.) 50 Hz: 320 CFM x 2 35 lb. (15.9 kg) (20:1 = 17.4 kg) (25:1 = 13.9 kg) 60 Hz: 520 CFM (245 liters/sec.) 50 Hz: 470 CFM 50 lb. (23 kg) (20:1 = 26.4 kg) (25:1 = 21.1 kg) (Gas and Electric Models) 750 CFM (354 liters/sec.) 75 lb. (34 kg) (20:1 = 31.7 kg) (25:1 = 25.4 kg) Airflow Gas & Steam Models 60 Hz: 920 CFM (434 liters/sec.) 50 Hz: 750 CFM (354 liters/sec.) Electric Models (194 liters/sec..) (194 liters/sec.) (151 liters/sec.) (222 liters/sec.) 750 CFM (354 liters/sec.) Energy Data Gas Models Gas Models Gas Models x 2 Gas Models Gas Models Gas Models 64,000 Btu/hr (18.8 kW) 73,000 Btu/hr (21.4 kW) 73,000 Btu/hr (21.4 kW) 90,000 Btu/hr (26.4 kW) 120,000 Btu/hr (30,240 kcal/hr) 165,000 Btu/hr (41,580 kcal/hr) Steam Models Steam Models Steam Models x 2 Steam Models Steam Models Steam Models At 100 psig (6.9 bar): 3.0 BHP At 100 psig (6.9 bar): 3.0 BHP At 100 psig (6.9 bar): 2.4 BHP At 100 psig (6.9 bar): 3.5 BHP At 100 psig (6.9 bar): 5.8 BHP At 100 psig (6.9 bar): 5.8 BHP 100,437 Btu/hr (29.4 kW) 100,437 Btu/hr (29.4 kW) 80,350 Btu/hr (23.5 kW) 117,176 Btu/hr (34.3 kW) At 15 psig (1.0 bar): 1.7 BHP At 15 psig (1.0 bar): 1.7 BHP At 15 psig (1.0 bar): 1.3 BHP At 15 psig (1.0 bar): 2.0 BHP 58,300 Btu/hr (17.1 kW) 58,300 Btu/hr (17.1 kW) 45,400 Btu/hr (13.3 kW) 65,600 Btu/hr (19.2 kW) Electric Models Electric Models Electric Models x 2 Electric Models Electric Models Electric Models 12 kW 21.0 kW 21.0 kW 24.0 kW 30.0 kW 30.0 kW Electrical Gas & Steam Models Gas & Steam Models Gas & Steam Models Gas & Steam Models Gas Models Serial Plate Gas Models Serial Plate Specifications 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G Amps Amps 100/200/60/1; 2W+G 100/200/60/1; 2W+G 100/200/60/1; 2W+G 100/200/60/1; 2W+G Non Rev Rev Non Rev Rev 100/200/50/1; 2W+G 100/200/50/1; 2W+ G 100/200/50/1; 2W+G 100/200/50/1; 2W+G 120/60/1 9.3 – 120/60/1 13.8 – 230–240/50/1; 2W+G 230–240/50/1; 2W+G 230–240/50/1; 2W+G 230–240/50/1; 2W+G 200–208/240/60/1 5.1 – 200–208/240/60/1 7.6 – 200–208/240/60/3; 3W+G 200–208/240/60/3; 3W+G 200-208/240/60/3; 3W+G 200–208/240/60/3; 3W+G 200–208/240/60/3 2.8 2.8 200–208/240/60/3 3.8 4.3 200/50/3; 3W+G 200/50/3; 3W+G 200/50/3; 3W+G 200/50/3; 3W+G 200/50/3 3.3 4.2 200/50/3 3.5 4.5 230–240/50/3; 3W+G 230–240/50/3; 3W+G 230–240/50/3; 3W+G 230–240/50/3; 3W+G 460/480/60/3 1.4 1.9 460/480/60/3 1.9 2.1 380/400–415/50/3; 3W+G 380/400–415/50/3; 3W+G 380/400–415/50/3; 3W+G 380/400–415/50/3; 3W+G 230–240/50/3 6.3 6.9 230–240/50/3 6.7 7.0 460–480/60/3; 3W+G 460–480/60/3; 3W+G 460-480/60/3; 3W+G 460–480/60/3; 3W+G 380/400–415/50/3 1.6 2.0 380/400–415/50/3 1.8 2.1 Electric Models Electric Models Electric Models* Electric Models 208/60/1; 3W+G 208/60/1; 3W+G 200–208/60/3; 3W+G 208/60/1; 3W+G Electric Models – 30 kW Electric Models – 30 kW 240/60/1; 3W+G 240/60/1; 3W+G 200/50/3; 3W+G 240/60/1; 3W+G 200–208/60/3 89 88 200–208/60/3 89 88 200/60/1; 2W+G 200/60/1; 2W+G 230-240/50/3; 3W+G** 200/60/1; 2W+G 240/60/3 79 78 240/60/3 79 78 200/50/1; 2W+G 200/50/1; 2W+G 240/60/3; 3W+G 200/50/1; 2W+G 200/50/3 84 85 200/50/3 84 85 230–240/50/1; 2W+G 230–240/50/1; 2W+G 380/50/3; 3W+G 230–240/50/1; 2W+G 230/50/3 73 75 230/50/3 73 75 200–208/60/3; 3W+G 200–208/60/3; 3W+G 400–415/50/3; 3W+G 200–208/60/3; 3W+G 480/60/3 38 38 480/60/3 38 38 200/50/3; 3W+G 200/50/3; 3W+G 460–480/60/3; 3W+G 200/50/3; 3W+G 240/50/3 79 78 240/50/3 79 78 230–240/50/3; 3W+G 230–240/50/3; 3W+G 230-240/50/3; 3W+G 230–240/50/3; 3W+G 380/50/3 47 48 380/50/3 47 48 240/60/3; 3W+G 240/60/3; 3W+G 240/60/3; 3W+G 240/60/3; 3W+G 400–415/50/3 43 44 400–415/50/3 43 44 380/50/3; 3W+G 380/50/3; 3W+G 380/50/3; 3W+G 380/50/3; 3W+G 400–415/50/3; 3W+G 400–415/50/3; 3W+G * Not available in Canada 400–415/50/3; 3W+G Electric Models – 21 kW 460–480/60/3; 3W+G 460–480/60/3; 3W+G ** Not available in EU 460–480/60/3; 3W+G 240/50/1 93 95 Plumbing Gas Models: 1/2”– NPT Gas Models: 1/2”–NPT Gas Models: 1/2”–NPT Gas Models: 1/2”–NPT Gas Models: 1/2”–NPT Gas Models: 1/2”–NPT Connections One manifold gas connection Steam Models: 3/4”– NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Net Weight 299 lb. (135 kg) 331 lb. (150 kg) 544 lb. (247 kg) 361 lb. (164 kg) 545 lb. (247 kg) 615 lb. (279 kg) Shipping 332 lb. (151 kg) 364 lb. (165 kg) 582 lb. (264 kg) 394 lb. (179 kg) Domestic Export Domestic Export Weight 602 lb. (273 kg) 670 lb. (304 kg)677 lb. (307 kg) 750 lb. (340 kg) Shipping Width – 30” (762 mm) Width – 30” (762 mm) Width – 33.5” (851 mm) Width – 33.5” (851 mm) Width – 41.5” (1054 mm) Width – 41.5” (1054 mm) Dimensions Depth – 41” (1041 mm) Depth – 47” (1194 mm) Depth – 47” (1194 mm) Depth – 47” (1194 mm) Depth – 52.1” (1323 mm) Depth – 56.4” (1433 mm) Height – 69” (1753 mm) Height – 69” (1753 mm) Height – 81” (2057 mm) Height – 69” (1753 mm) Height – 81” (2057 mm) Height – 81” (2057 mm) 2 x 75 lb. (2 x 34 kg) (20:1 = 52.3 kg) (25:1 = 41.8 kg) 1000 CFM (472 liters/sec.) x 2 Gas Models x 2 180,000 Btu/hr x 2 (45,360 kcal/h) x 2 Gas Models 220/380 V–50 Hz 3 Ph–10.9/6.2 Amp 240/415 V–50 Hz 3 Ph–10.7/5.9 Amp 346 V–50 Hz 3 Ph– 6.2 Amp 575 V–60 Hz 3 Ph–4.6 Amp 480 V–60 Hz 3 Ph–5.3 Amp 208/240 –60 Hz 3 Ph–11.1/10.4 Amp 1”–NPT 1818 lb. (821 kg) Domestic Export 1960 lb. (889 kg) 2200 lb. (998 kg) Width – 93” (2362 mm) Depth – 57” (1448 mm) Height – 76” (1930 mm) Tumbler models are made to suit a variety of electrical service characteristics. See your CISSELL distributor for specifications. Door opening–22.68” (576 mm). Motor size (25 lb to 35 lb): fan–1/4 HP (187 W); cylinder–1/4 HP (187 W). Air outlet diameter on CHD–25/CHD–30 –6” (152 mm); CHD–30 Stack/CHD–35 –8” (203 mm) with one manifold vent connection on CHD-30 Stack. For further details on installation refer to Installation, Operation and Maintenance instructions supplied with the tumbler. Due to continuous product improvements, design and specifications subject to change without notice. Features and certifications may vary by model. Manufactured with ISO 9001 quality certification. Amperage ratings available in Installation Manual. *Also available in optional heights of 72–1/4” (1835 mm) and 76–1/4” (1937 mm). Also complies with international electrical emissions and immunity standards. Rev: 09/02 CISSELL Manufacturing Co. 831 South First Street / P.O.Box 32270 Louisville,KY 40232-2270 USA Tel.: (502) 587-1292 Fax: (502) 585-3625 www.cissellmfg.com APS 04/03-5m T H E U LT I M AT E D R Y I N G M A C H I N E ™
© Copyright 2026 Paperzz