Cissell 25-75

A
W o r l d
o f
C o m p e t e n c e
DRYER SERIES
FOR ON-PREMISE LAUNDRY APPLICATIONS
CAPACITIES
25–75 POUNDS
T H E U LT I M AT E D R Y I N G M A C H I N E ™
GIVE US YOUR TOUGHEST JOB.
Affordable Quality:
For more than 50 years
CISSELL has been a leader in
the design and manufacture
of products for the laundry
and dry cleaning industry.
In the CISSELL on-premise
laundry line of standard
and stack dryers, we’ve
combined our unparalleled
experience with years of
extensive research to
create the perfect balance
of quality and affordability.
DURABLE CONSTRUCTION
• Stainless Steel Door – Standard
Our dryers are incorporated with only the finest quality
materials right down to the loading door and hinges!
Constructed from high-grade steel, our heavy-duty
door and hinges will stand up to the toughest
laundry conditions time and time again. In addition,
the circular door glassis sealed with a 7/8” rubber
gasket to secure it in place while providing greater
strength and rigidity.
The result:
A series of gas, steam and
electric dryers with various
capacities, which meet the
needs of virtually every
on-premise laundry facility.
Whatever your needs,
you can count on CISSELL
for the highest quality
products that stand up
to your toughest demands.
CISSELL is so confident
in the performance and
construction of our products
that we back every dryer
with a 3 year warranty*
from the date of original
sale, covering any part
of the dryer which fails as
a result of a defect on
material or workmanship.
*Parts only, labor not included.
• Lint Compartment
The fine mesh lint screen cleans
itself automatically by depositing
lint into a large storage area for
easy removal. Therefore, the most
efficient drying is achieved while
eliminating the need to manually
clean the filter after each use.
• All Belt Drive System
Our dryers are constructed with
a self-adjusting tension idler, metal
pulleys and sealed bearings for quiet
operation and low maintenance.
• Galvanized Steel Cylinder
Our cylinders are constructed
of galvanized steel to ensure
a long life. Optionally available
in stainless steel.
See CISSELL warranty for specifics.
50 & 75 LB. DRUM SHOWN
T H E U LT I M AT E D R Y I N G M A C H I N E ™
THE IDEAL COMBINATION
OF EFFICIENCY AND DURABILITY.
Only from CISSELL:
CONTROLS AND FEATURES
Nobody else gives you
• Control Units
Our Microprocessor control is state of the art.
Computerized models feature 5 preset automatic
drying cycles with an option
to further customize.
➧ Anti-Wrinkle Safety Tumble
— if door is not opened at end
of cycle, dryer tumbles to
remove excess heat, preventing
unnecessary wrinkling.
➧ Basket RPM Display — push and hold the start
button and it displays RPM to let maintenance
workers determine when belts need tightening.
so many advantages
with so much
affordability.
Our manual dual timer control
models allow operators to
easily set both drying time and
cool-down time.
Only CISSELL puts it
all together in our
on-premise laundry
line... Call for a
• Airflow*
Fabrics receive the most concentrated drying possible
with minimum energy consumption, because
the concentrated airflow pattern and
sealed cylinder rims ensure that the
maximum amount of warm air enters
the cylinder and passes through the clothes.
demonstration or
*For models CHD–25, CHD–30, CHD–30 Stack and CHD–35
www.cissellmfg.com
•
➧
➧
➧
➧
➧
➧
Additional Features
Integrated motor overload protection
Solid steel cap over top of dryer
Embossed steel cabinet for easy cleaning
All major components are easily accessible
High temperature limit control
Superior exterior finish
T H E U LT I M AT E D R Y I N G M A C H I N E ™
more information
today, or visit our
website at
S P E C I F I C A T I O N S
CHD–25
CHD–30
CHD–30 Stack
CHD–35
CHD–50
CHD–75
HD–75 Stack
Width
Depth
Height
Cyl. Depth
Cyl. Diameter
Cyl. Volume
28” (711 mm)
38-7/8” (987 mm)
63-7/8” (1622 mm)*
24” (610 mm)
26-1/2” (673 mm)
7.66 cu. ft. (217 liters)
28” (711 mm)
44-7/8” (1140 mm)
63-7/8” (1622 mm)*
30” (762 mm)
26-1/2” (673 mm)
9.57 cu. ft. (271 liters)
31-1/2” (800 mm)
42-7/8” (1089 mm)
76-1/4” (1937 mm)
26” (660 mm)
30” (762 mm)
10.63 cu. ft. (301 liters)
31-1/2” (800 mm)
44-7/8” (1140 mm)
63-7/8” (1622 mm)*
30” (762 mm)
30” (762 mm)
12.27 cu. ft. (347 liters)
38-5/8” (981mm)
47” (1194 mm)
76-5/8” (1946 mm)
30” (762 mm)
37” (940 mm)
18.67 cu. ft. (528 liter)
38-5/8” (981mm)
53” (1346 mm)
76-5/8” (1946 mm)
36” (914 mm)
37” (940 mm)
22.4 cu. ft. (634 liter)
54” (1372 mm)
63-1/2” (1613 mm)
87-1/2” (2223 mm)
36” (914 mm)
36” (914 mm)
21.2 cu. ft. (1046 liter)
Dry Capacity
Filling Ratios
25 lb. (11.3 kg)
(20:1 = 10.9 kg)
(25:1 = 8.7 kg)
60 Hz: 450 CFM
(212 liters/sec.)
50 Hz: 410 CFM
30 lb. (13.6 kg)
(20:1 = 13.6 kg)
(25:1 = 10.8 kg)
60 Hz: 450 CFM
(212 liters/sec.)
50 Hz: 410 CFM
2 x 30 lb. (13.6 kg)
(20:1 = 15.1 kg)
(25:1 = 12.0 kg)
60 Hz: 350 CFM x 2
165 liters/sec.)
50 Hz: 320 CFM x 2
35 lb. (15.9 kg)
(20:1 = 17.4 kg)
(25:1 = 13.9 kg)
60 Hz: 520 CFM
(245 liters/sec.)
50 Hz: 470 CFM
50 lb. (23 kg)
(20:1 = 26.4 kg)
(25:1 = 21.1 kg)
(Gas and Electric Models)
750 CFM (354 liters/sec.)
75 lb. (34 kg)
(20:1 = 31.7 kg)
(25:1 = 25.4 kg)
Airflow
Gas & Steam Models
60 Hz: 920 CFM (434 liters/sec.)
50 Hz: 750 CFM (354 liters/sec.)
Electric Models
(194 liters/sec..)
(194 liters/sec.)
(151 liters/sec.)
(222 liters/sec.)
750 CFM (354 liters/sec.)
Energy Data
Gas Models
Gas Models
Gas Models x 2
Gas Models
Gas Models
Gas Models
64,000 Btu/hr (18.8 kW)
73,000 Btu/hr (21.4 kW)
73,000 Btu/hr (21.4 kW)
90,000 Btu/hr (26.4 kW)
120,000 Btu/hr (30,240 kcal/hr) 165,000 Btu/hr (41,580 kcal/hr)
Steam Models
Steam Models
Steam Models x 2
Steam Models
Steam Models
Steam Models
At 100 psig (6.9 bar): 3.0 BHP At 100 psig (6.9 bar): 3.0 BHP At 100 psig (6.9 bar): 2.4 BHP At 100 psig (6.9 bar): 3.5 BHP At 100 psig (6.9 bar): 5.8 BHP At 100 psig (6.9 bar): 5.8 BHP
100,437 Btu/hr (29.4 kW)
100,437 Btu/hr (29.4 kW)
80,350 Btu/hr (23.5 kW)
117,176 Btu/hr (34.3 kW)
At 15 psig (1.0 bar): 1.7 BHP At 15 psig (1.0 bar): 1.7 BHP At 15 psig (1.0 bar): 1.3 BHP At 15 psig (1.0 bar): 2.0 BHP
58,300 Btu/hr (17.1 kW)
58,300 Btu/hr (17.1 kW)
45,400 Btu/hr (13.3 kW)
65,600 Btu/hr (19.2 kW)
Electric Models
Electric Models
Electric Models x 2
Electric Models
Electric Models
Electric Models
12 kW
21.0 kW
21.0 kW
24.0 kW
30.0 kW
30.0 kW
Electrical
Gas & Steam Models
Gas & Steam Models
Gas & Steam Models
Gas & Steam Models
Gas Models Serial Plate Gas Models Serial Plate
Specifications 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G 120/208–240/60/1; 2W/3W+G
Amps
Amps
100/200/60/1; 2W+G
100/200/60/1; 2W+G
100/200/60/1; 2W+G
100/200/60/1; 2W+G
Non Rev Rev
Non Rev Rev
100/200/50/1; 2W+G
100/200/50/1; 2W+ G
100/200/50/1; 2W+G
100/200/50/1; 2W+G
120/60/1
9.3 – 120/60/1
13.8 –
230–240/50/1; 2W+G
230–240/50/1; 2W+G
230–240/50/1; 2W+G
230–240/50/1; 2W+G
200–208/240/60/1 5.1 – 200–208/240/60/1 7.6 –
200–208/240/60/3; 3W+G
200–208/240/60/3; 3W+G
200-208/240/60/3; 3W+G
200–208/240/60/3; 3W+G
200–208/240/60/3 2.8 2.8 200–208/240/60/3 3.8 4.3
200/50/3; 3W+G
200/50/3; 3W+G
200/50/3; 3W+G
200/50/3; 3W+G
200/50/3
3.3 4.2 200/50/3
3.5 4.5
230–240/50/3; 3W+G
230–240/50/3; 3W+G
230–240/50/3; 3W+G
230–240/50/3; 3W+G
460/480/60/3
1.4 1.9 460/480/60/3
1.9 2.1
380/400–415/50/3; 3W+G
380/400–415/50/3; 3W+G
380/400–415/50/3; 3W+G
380/400–415/50/3; 3W+G
230–240/50/3
6.3 6.9 230–240/50/3
6.7 7.0
460–480/60/3; 3W+G
460–480/60/3; 3W+G
460-480/60/3; 3W+G
460–480/60/3; 3W+G
380/400–415/50/3 1.6 2.0 380/400–415/50/3 1.8 2.1
Electric Models
Electric Models
Electric Models*
Electric Models
208/60/1; 3W+G
208/60/1; 3W+G
200–208/60/3; 3W+G
208/60/1; 3W+G
Electric Models – 30 kW
Electric Models – 30 kW
240/60/1; 3W+G
240/60/1; 3W+G
200/50/3; 3W+G
240/60/1; 3W+G
200–208/60/3
89 88 200–208/60/3
89 88
200/60/1; 2W+G
200/60/1; 2W+G
230-240/50/3; 3W+G**
200/60/1; 2W+G
240/60/3
79 78 240/60/3
79 78
200/50/1; 2W+G
200/50/1; 2W+G
240/60/3; 3W+G
200/50/1; 2W+G
200/50/3
84 85 200/50/3
84 85
230–240/50/1; 2W+G
230–240/50/1; 2W+G
380/50/3; 3W+G
230–240/50/1; 2W+G
230/50/3
73 75 230/50/3
73 75
200–208/60/3; 3W+G
200–208/60/3; 3W+G
400–415/50/3; 3W+G
200–208/60/3; 3W+G
480/60/3
38 38 480/60/3
38 38
200/50/3; 3W+G
200/50/3; 3W+G
460–480/60/3; 3W+G
200/50/3; 3W+G
240/50/3
79 78 240/50/3
79 78
230–240/50/3; 3W+G
230–240/50/3; 3W+G
230-240/50/3; 3W+G
230–240/50/3; 3W+G
380/50/3
47 48 380/50/3
47 48
240/60/3; 3W+G
240/60/3; 3W+G
240/60/3; 3W+G
240/60/3; 3W+G
400–415/50/3
43 44 400–415/50/3
43 44
380/50/3; 3W+G
380/50/3; 3W+G
380/50/3; 3W+G
380/50/3; 3W+G
400–415/50/3; 3W+G
400–415/50/3; 3W+G
* Not available in Canada
400–415/50/3; 3W+G
Electric Models – 21 kW
460–480/60/3; 3W+G
460–480/60/3; 3W+G
** Not available in EU
460–480/60/3; 3W+G
240/50/1
93 95
Plumbing
Gas Models: 1/2”– NPT
Gas Models: 1/2”–NPT
Gas Models: 1/2”–NPT
Gas Models: 1/2”–NPT
Gas Models: 1/2”–NPT
Gas Models: 1/2”–NPT
Connections
One manifold gas connection
Steam Models: 3/4”– NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT Steam Models: 3/4”–NPT
Net Weight
299 lb. (135 kg)
331 lb. (150 kg)
544 lb. (247 kg)
361 lb. (164 kg)
545 lb. (247 kg)
615 lb. (279 kg)
Shipping
332 lb. (151 kg)
364 lb. (165 kg)
582 lb. (264 kg)
394 lb. (179 kg)
Domestic
Export
Domestic
Export
Weight
602 lb. (273 kg) 670 lb. (304 kg)677 lb. (307 kg) 750 lb. (340 kg)
Shipping
Width – 30” (762 mm)
Width – 30” (762 mm)
Width – 33.5” (851 mm)
Width – 33.5” (851 mm)
Width – 41.5” (1054 mm)
Width – 41.5” (1054 mm)
Dimensions
Depth – 41” (1041 mm)
Depth – 47” (1194 mm)
Depth – 47” (1194 mm)
Depth – 47” (1194 mm)
Depth – 52.1” (1323 mm)
Depth – 56.4” (1433 mm)
Height – 69” (1753 mm)
Height – 69” (1753 mm)
Height – 81” (2057 mm)
Height – 69” (1753 mm)
Height – 81” (2057 mm)
Height – 81” (2057 mm)
2 x 75 lb. (2 x 34 kg)
(20:1 = 52.3 kg)
(25:1 = 41.8 kg)
1000 CFM
(472 liters/sec.) x 2
Gas Models x 2
180,000 Btu/hr x 2
(45,360 kcal/h) x 2
Gas Models
220/380 V–50 Hz
3 Ph–10.9/6.2 Amp
240/415 V–50 Hz
3 Ph–10.7/5.9 Amp
346 V–50 Hz
3 Ph– 6.2 Amp
575 V–60 Hz
3 Ph–4.6 Amp
480 V–60 Hz
3 Ph–5.3 Amp
208/240 –60 Hz
3 Ph–11.1/10.4 Amp
1”–NPT
1818 lb. (821 kg)
Domestic Export
1960 lb. (889 kg) 2200 lb. (998 kg)
Width – 93” (2362 mm)
Depth – 57” (1448 mm)
Height – 76” (1930 mm)
Tumbler models are made to suit a variety of electrical service characteristics. See your CISSELL distributor for specifications. Door opening–22.68” (576 mm). Motor size (25 lb to 35 lb): fan–1/4
HP (187 W); cylinder–1/4 HP (187 W). Air outlet diameter on CHD–25/CHD–30 –6” (152 mm); CHD–30 Stack/CHD–35 –8” (203 mm) with one manifold vent connection on CHD-30 Stack. For further details
on installation refer to Installation, Operation and Maintenance instructions supplied with the tumbler. Due to continuous product improvements, design and specifications subject to change without notice. Features and certifications may vary by model. Manufactured with ISO 9001 quality certification. Amperage ratings available in Installation Manual.
*Also available in optional heights of 72–1/4” (1835 mm) and 76–1/4” (1937 mm). Also complies with international electrical emissions and immunity standards.
Rev: 09/02
CISSELL Manufacturing Co.
831 South First Street / P.O.Box 32270
Louisville,KY 40232-2270 USA
Tel.: (502) 587-1292
Fax: (502) 585-3625
www.cissellmfg.com
APS 04/03-5m
T H E U LT I M AT E D R Y I N G M A C H I N E ™