PDF - This Chapter

CH A P T E R
1
Room Requirements and System Specifications
June 5, 2013, OL-23420-01
This chapter describes the room sizes that are supported for the CTS-500-32 and the size of the system
and includes the following sections:
•
Room Size and System-to-User Distance Recommendations, page 1-1
•
CTS-500-32 Power Consumption, page 1-5
•
Height, Width and Weight of Pedestal-Mounted CTS-500-32, page 1-6
•
Height, Width and Weight of Table Stand-Mounted CTS-500-32, page 1-7
Room Size and System-to-User Distance Recommendations
Figure 1-1 shows the minimum and maximum recommended room sizes for a CTS-500-32 and the range
of distance that is recommended between the front of the system display and the user. Figure 1-2 through
Figure 1-4 show additional room recommendations for various room configurations.
Note
The CTS-500-32 allows for a wide range of distance between the system and the user. Note, however,
that the size of the user increases the closer you get to the system, and becomes smaller the farther away
you get from the systems. To compensate for the increased or reduced size, you can zoom the camera
lens. See the “Adjusting the Camera Lens to Resize the User” section on page 4-23 for more information.
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
OL-23420-01
1-1
Chapter 1
Room Requirements and System Specifications
Room Size and System-to-User Distance Recommendations
Figure 1-1
Room Size and Seating Distance Recommendations
Room Height
8 ft (2.44m) Min
10 ft (3.05m) Max
5 ft (1.52m) Min
15 ft (4.57m) Max
1
208794
3.5 ft (1.07m) Min
4.5 ft (1.37m) Recommended
5.5 ft (1.68m) Max
6 ft (1.83m) Min
15 ft (4.57m) Max
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
1-2
OL-23420-01
Chapter 1
Room Requirements and System Specifications
Room Size and System-to-User Distance Recommendations
Figure 1-2
Room Size and Seating Distance Recommendations — CTS-500-32 With a Two Users and a Freestanding
Desk
Room Height
8 ft (2.44m) Min
10 ft (3.05m) Max
42 in (107cm)
walkway clearnace
42 in (107cm)
walkway clearnace
Desk
9 ft (2.74m) Min
15 ft (4.57m) Max
208796
30” Spacing
3.5 ft (1.07m) Min
4.5 ft (1.37m) Recommended
5.5 ft (1.68m) Max
8.5 ft (2.59m) Min
15 ft (4.57m) Max
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
OL-23420-01
1-3
Chapter 1
Room Requirements and System Specifications
Room Size and System-to-User Distance Recommendations
Figure 1-3
Room Size and Seating Distance Recommendations —CTS-500-32 With a Single User and Freestanding
Desk
Room Height
8 ft (2.44m) Min
10 ft (3.05m) Max
6.5 ft (1.98m) Min
15 ft (4.57m) Max
42 in (107cm)
walkway
clearnace
42 in (107cm)
walkway clearnace
Desk
208795
3.5 ft (1.07m) Min
4.5 ft (1.37m) Recommended
5.5 ft (1.68m) Max
8 ft (2.44m) Min
15 ft (4.57m) Max
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
1-4
OL-23420-01
Chapter 1
Room Requirements and System Specifications
CTS-500-32 Power Consumption
Figure 1-4
Room Size and Seating Distance Recommendations —CTS-500-32 Placed in a Corner
Room Height
8 ft (2.44m) Min
10 ft (3.05m) Max
30
in
6
(7
cm
pa
)S
n
ci
9 ft (2.74m) Min
15 ft (4.57m) Max
g
Desk
208793
3.5 ft (1.07m) Min
4.5 ft (1.37m) Recommended
5.5 ft (1.68m) Max
8.5 ft (2.59m) Min
15 ft (4.57m) Max
CTS-500-32 Power Consumption
Table 1-1 shows the power consumption numbers for the CTS-500-32.
Table 1-1
CTS-500-32 Power Consumption
Component
Maximum
kW
Amperage
@120V
Typical
kW
Amperage
@120V
Standby/Idle
kW
Amperage
@120V
LCD Display and Lights1
0.152
1.270
0.143
1.200
0.001
0.010
Codec
0.091
0.760
0.069
0.580
0.066
0.550
Audio/Video Extension Unit
0.010
0.080
0.008
0.070
0.005
0.040
Presentation Display (optional)
0.155
1.290
0.020
0.170
0.001
0.010
POWER TOTAL for CTS-500-32
0.408
3.400
0.240
2.020
0.073
0.610
1. The display and lights use the same power source.
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
OL-23420-01
1-5
Chapter 1
Room Requirements and System Specifications
Height, Width and Weight of Pedestal-Mounted CTS-500-32
Height, Width and Weight of Pedestal-Mounted CTS-500-32
Figure 1-5 shows the dimensions of an assembled CTS-500-32 pedestal mount system.
Figure 1-5
CTS-500-32 Dimensions
37.2 inches
(94.5 cm)
52.0 to 62.9 inches
(132.1 to 159.8 cm)
Weight: 125 lb
(56.7 kg)
29.2 inches
(74.3 cm)
208679
28.1 inches
(71.5 cm)
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
1-6
OL-23420-01
Chapter 1
Room Requirements and System Specifications
Height, Width and Weight of Table Stand-Mounted CTS-500-32
Height, Width and Weight of Table Stand-Mounted CTS-500-32
The following are the dimensions of the table stand-mounted CTS-500-32:
Height: 27 inches, +/-2 inches (69 cm +/- 5 cm)
Base Depth: 13 inches (33 cm)
Base Width: 24 inches (61 cm)
Weight of desktop and stand: 30 lbs (14 kg)
Weight of display and codec: 47 lbs (21 kg)
Total weight of system: 77 lbs (35 kg)
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
OL-23420-01
1-7
Chapter 1
Room Requirements and System Specifications
Height, Width and Weight of Table Stand-Mounted CTS-500-32
Cisco TelePresence System 500-32 Installation, First-Time Setup, and Field-Replaceable Unit Guide
1-8
OL-23420-01