Kuhlman Electric Corporation 15000 Volt Instrument Transformers 15000 Volt March 2008 Table of Contents Description Model Page Wound, Dry-Type VT – Y Burden PTT-110-977 3-4 Wound, Dry-Type VT – Z Burden (High Accuracy available) PTT-110-9710(H) 5-6 Wound, Oil-Filled VT – ZZ Burden (High Accuracy available) SPOF-110 (DB) 7-8 Wound, Dry-Type CT – Standard Range (High Accuracy available) BB-15-971(H) 9-10 Wound, Dry-Type CT – Extended Range BB-15-972 11-12 4 ½” Window CT – Single, Dual & Multi Ratio (High Accuracy available) LG(X)-15-585 13-14 4 ½” Window CT – Single, Dual & Multi Ratio (High Accuracy available) LG(X)-15-683 15-16 4 ½” Window CT – Single, Dual & Multi Ratio LG-15-879 17-18 8 ¾” Window CT – Single, Dual & Multi Ratio (High Accuracy available) LG(X)-15-6513 19-20 Wound, Oil-Filled CT (High Accuracy available) COF(CXM)-110 21-22 Wound, Dry-Type, Single Phase Metering Unit KM-15-972 23-24 Wound, Oil-Filled, Single Phase Metering Unit (High Accuracy available) JS(JXM)-110 25-26 Wound, Oil-Filled, Three Phase Metering Unit (High Accuracy available) MVCT(MXM)-110 27-28 Wound, Dry-Type, Three Phase CT/VT Metering Rack (High Accuracy available) ME-015 29-30 Wound, Dry-Type, Three Phase Metering Unit Metering Rack MK-15 31-32 Three Phase Dead-Front CT/VT Metering Cubicle (High Accuracy available) MP-015 33-34 Indoor, Wound, Dry-Type VT – Z Burden (High Accuracy available) U/VCD-17(H) 35-36 Indoor, Wound, Dry-Type CT – Standard Range (High Accuracy available) CID-17(H) 37-38 Indoor, Wound, Dry-Type, Single Phase Dead-Front Metering Unit KCB-17 39-40 Three Phase Low Profile, Dead-Front Metering Unit Metering Cubicle MI-15 41-42 2 Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage PTT–110–977 Voltage Transformer 15000 Volt Outdoor 15kV, °110kV BIL, Single & Dual Ratios Molded Epoxy, Wound Type, Metering/Relaying March 2008 application The PTT-110-977 outdoor voltage transformer is rated for use on 5,000 & 15,000 volt systems with °110kV BIL. Primary voltage ratios are available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems, at 60 Hertz (Hz). This dry-type, solid-cast voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. The primary terminal(s) are M12 stud with a compression type lug for #8 - #2 AWG conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The PTT-110-977 will operate with 0.3 Class accuracy for metering and relay applications with burdens of 0, W, X, M and Y. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The PTT is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Units are available in single or double bushing models. Contact factory for other needs. ORDERING INFO FOR PTT-110-977(G) Ratio Primary° Secondary 20:1 35:1 40:1 42:1 60:1 63.5:1 66.4:1 66.67:1 70:1 70/120:1 100:1 110:1 115:1 120:1 2400 4200 4800 5040 7200 7620 7920 8000 8400 8400 12000 13200 13800 14400 120 120 120 120 120 120 120 120 120 120/70 120 120 120 120 HIGH ACCURACY N/A Catalog Number* 1 Bushing° 2 Bushing B913G020S0 ---D913G060S0 D913G063S0 D913G066S0 D913G067S0 D913G070S0 D913G070D0 ----- D913020S0 D913035S0 D913040S0 D913042S0 D913060S0 D913063S0 D913066S0 -D913070S0 -D913100S0 D913110S0 D913115S0 D913120S0 Accuracy/ Burden Catalog Number Accuracy/ Burden 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y --------------- --------------- - Thermal Burden Rating (Typical): Single Bushing (750VA), Double Bushing (1000VA). - Overvoltage Rating: 1.1x cont. ° Single Bushing units with less than 5kV primary voltage are rated 60kV BIL. * All units are RUS accepted and IC Approval AE-0967 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 3 15000 Volt March 2008 4 PTT–110–977 Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage PTT–110–9710(H) Voltage Transformer Outdoor 15kV, °110kV BIL, Single & Dual Ratios (w/ Tertiary) Molded Epoxy, Wound Type, Metering/Relaying 15000 Volt March 2008 application The PTT-110-9710(H) outdoor voltage transformer is rated for use on 5,000 & 15,000 volt systems with °110kV BIL. Primary voltage ratios are available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems, at 60 Hertz (Hz). This dry-type, solid-cast voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. The primary terminal(s) are M12 stud with a compression type lug for #8 - #2 AWG conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The PTT-110-9710 will operate with 0.3 Class accuracy for metering and relay applications with burdens of 0, W, X, M, Y and Z. The PTT-110-9710H will operate with 0.15 Class high accuracy for metering applications with burdens of 0, W, X, M and Y. The transformer is accurate from 90% to 110% of rated primary voltage. standard dimensions for interchangeability in the field. mounting The PTT is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry options Units are available with dual system voltage ratings and/or in single or double bushing models. The PTT-110-9710H high accuracy voltage transformer is only available in the double bushing model. Contact factory for other needs. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. ORDERING INFO FOR PTT-110-9710(G) Ratio Primary° Secondary 20:1 20/60:1 30:1 35:1 40:1 60:1 60:1:1 63.5:1 63.5:1:1 70:1 70:1:1 100:1 110:1 120:1 120:1:1 2400 2400/7200 3600 4200 4800 7200 7200 7620 7620 8400 8400 12000 13200 14400 14400 120 120 120 120 120 120 120 & 120 120 120 & 120 120 120 & 120 120 120 120 120 Catalog Number* 1 Bushing° 2 Bushing B914G020S0 D914060P020G0 ---D914G060S0 -D914G063S0 D914G063Y0 D914G070S0 ------ D914020S0 -D914030S0 D914035S0 D914040S0 D914060S0 D914060Y0 D914063S0 -D914070S0 D914070Y0 D914100S0 D914110S0 D914120S0 D914120Y0 Accuracy/ Burden 0.3 0,W,X,M,Y,Z 0.3 0 to X / Y 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y HIGH ACCURACY PTT-110-9710H Catalog Number Accuracy/ Burden 2 Bushing Only D914020E0 --D914035E0 D914040E0 D914060E0 -D914063E0 -D914070E0 -D914100E0 D914110E0 D914120E0 -- 0.15 0,W,X,M,Y --0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y -0.15 0,W,X,M,Y -0.15 0,W,X,M,Y -0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y -- - Thermal Burden Rating (Typical): Std Acc, Single Ratio (1500VA), Dual Ratio (1000VA max), High Acc. (1000VA). - Overvoltage Rating (Typical): 1.1x cont. ° Single Bushing units with less than 5kV primary voltage are rated 60kV BIL. * All units are RUS accepted and IC Approval AE-1391 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 5 15000 Volt March 2008 6 PTT–110–9710(H) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage SPOF–110 (DB) Voltage Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single & Dual Ratios (w/ Tertiary) Oil-Filled, Wound Type, Metering/Relaying March 2008 application The SPOF-110 (DB) outdoor voltage transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary voltage ratios are available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems, at 60 Hertz (Hz). This oil-filled voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then finished with a Munsel 70 Gray baked-on electrostatic polyester powder. The primary bushing(s) are high strength porcelain with tin plated bronze, eye bolt terminal(s) that accept #8 - #2 AWG conductors and are locked with silicon bronze locking hardware. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½” NPT conduit hubs. The ground terminal is a ½”-13 pad. The unit is fitted with a pressure relief valve. accuracy performance The SPOF-110 (DB) will operate with 0.3 Class accuracy for metering applications with burdens of 0, W, X, M, Y, Z and ZZ. Upon request, 0.15 metering accuracy is available for burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The transformer is accurate from 90% to 110% of rated primary voltage. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. mounting The SPOF is designed for mounting on poles or substation structures in an upright position with ANSI type “A” hanger brackets or optional mounting feet. NOTE: Must be installed per NESC electrical clearances. options The SPOF is available in single or double bushing models, with NEMA 4-hole Primary Terminal(s), Mounting Feet, a 5kV H0 Bushing, Stainless Steel Tank, Oil Level Gauge, Oil Drain Valve, and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR SPOF-110 (DB) Ratio Primary Secondary 60:1:1 60/100:1:1 63.5:1:1 70:1:1 70/120:1 70/120:1:1 100:1:1 110:1:1 120:1:1 7200 7200 7620 8400 8400 8400 12000 13200 14400 120 & 120 120/72 & 120/72 120 & 120 120 & 120 120/70 120/70 & 120/70 120 & 120 120 & 120 120 & 120 HIGH ACCURACY SPOF-110 (DB) Catalog Number 1 Bushing 2 Bushing D830060YA D830100TA D830063YA D830070YA *D830120DA D830120TA ---- D840060YA D840100TA D840063YA D840070YA D840120DA D840120TA D840100YA D840110YA **D840120YA Accuracy/ Burden Catalog Number Accuracy/ Burden 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ 0.3 0,W,X,M,Y,Z,ZZ Add “AAEW” to the end of the standard catalog number 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ 0.15 0 to Z/0.3 ZZ - Thermal Burden Rating (Typical): 5000VA. - Overvoltage Rating: 1.1x cont., 1.9x 8 hours. - IC Approval *(AE-0724), **(AE-0669 Rev. 1). Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 7 15000 Volt March 2008 8 SPOF–110 (DB) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage BB–15–971(H) Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single & Dual Ratios Molded Epoxy, Wound Type, Metering/Relaying March 2008 application The BB-15-971(H) outdoor current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 1.5 (1200A max). This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The BB-15-971 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and T150 for relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The BB-15-971H will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B0.9. The transformer maintains 0.15 accuracy from 10% (0.3 accuracy from 2%) of Inom through its Rating Factor, and can be used continuously to this level. mounting The BB is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR BB-15-971 Ratio Catalog Number* 5:5 10:5 D9060005S0 D9060010S0 HIGH ACCURACY BB-15-971H Accuracy/Burden Metering Relay 0.3 B1.8 0.3 B1.8 T150 T150 Rating Factor Catalog Number* Accuracy/ Burden Rating Factor 1.5 1.5 D9060005E0 D9060010E0 0.15 B0.9 0.15 B0.9 1.5 1.5 … … … … … … … … 50:5 75:5 100:5 D9060050S0 D9060075S0 D9060100S0 0.3 B1.8 0.3 B1.8 0.3 B1.8 T150 T150 T150 1.5 1.5 1.5 D9060050E0 D9060075E0 D9060100E0 0.15 B0.9 0.15 B0.9 0.15 B0.9 1.5 1.5 1.5 … … … … … … … … 600:5 800:5 1000:5 1200:5 D9060600S0 D9060800S0 D9061000S0 D9061200S0 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 T150 T150 T150 T150 1.5 1.5 1.2 1.0 D9060600E0 D9060800E0 D9061000E0 D9061200E0 0.15 B0.9 0.15 B0.9 0.15 B0.9 0.15 B0.9 1.5 1.5 1.2 1.0 5/10:5 10/20:5 D9060005D0 D9060010D0 0.3 B0.5/B1.8 0.3 B0.5/B1.8 T75/T150 T75/T150 2.0/1.5 2.0/1.5 D9060005F0 D9060010F0 0.15 B0.5/B0.9 0.15 B0.5/B0.9 2.0/1.5 2.0/1.5 … … … … … … … … 300/600:5 400/800:5 500/1000:5 600/1200:5 D9060300D0 D9060400D0 D9060500D0 D9060600D0 0.3 B0.5/B1.8 0.3 B0.5/B1.8 0.3 B0.5/B1.8 0.3 B0.5/B1.8 T75/T150 T75/T150 T75/T150 T75/T150 2.0/1.5 1.2/1.2 1.0/1.0 1.0/1.0 D9060300F0 D9060400F0 D9060500F0 D9060600F0 0.15 B0.5/B0.9 0.15 B0.5/B0.9 0.15 B0.5/B0.9 0.15 B0.5/B0.9 2.0/1.5 1.2/1.2 1.0/1.0 1.0/1.0 - 1 Second Thermal/Mechanical Rating: 100x/200x full winding Inom (75x/150x for above 600:5 & 300/600:5). * All units are RUS accepted and IC Approval AE-0785 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 9 15000 Volt March 2008 10 BB–15–971(H) Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage BB–15–972 Current Transformer Outdoor 15kV, 110kV BIL, Single Ratios Molded Epoxy, Wound Type, Metering 15000 Volt March 2008 application The BB-15-972 outdoor extended range current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). This dry-type, solid-cast current transformer will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The BB-15-972 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The transformer is accurate through its Rating Factor, and can be used continuously to this level. mounting The BB is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR BB-15-972 Ratio Catalog Number* 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 D9070005S0 D9070010S0 D9070015S0 D9070020S0 D9070025S0 D9070030S0 D9070040S0 D9070050S0 D9070075S0 D9070100S0 D9070150S0 D9070200S0 D9070300S0 D9070400S0 D9070600S0 D9070800S0 D9071000S0 D9071200S0 HIGH ACCURACY N/A Accuracy/Burden Metering Relay 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 ------------------- Rating Factor Catalog Number Accuracy/ Burden Rating Factor 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 1.5 1.2 1.0 ------------------- ------------------- ------------------- - 1 Second Thermal/Mechanical Rating: 150x/300x Inom (120x/240x for 400:5, 100x/200x for 600:5, 75x/150x for above 600:5). * All units are RUS accepted. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 11 15000 Volt March 2008 12 BB–15–972 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG(X)–15–585 Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The LG(X)-15-585 outdoor, window-type current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 200:5 to 5000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 4 ½” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. An optional primary bus bar with NEMA 4-hole pads can also be provided (5500A max). The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. accuracy performance The LG-15-585 will operate with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The LGX-15-585 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 up to B1.8. The transformer maintains 0.3 accuracy from 1% of Inom through its Rating Factor, and can be used continuously to this level (for 0.15 accuracy range, see ratings specific to each ratio). March 2008 mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. options The LG is available with a primary bus bar kit or conductive bird guards to prevent foreign objects from entering the porcelain window. Contact factory for other needs. ORDERING INFO FOR LG-15-585 HIGH ACCURACY LGX-15-585 Accuracy/Burden Metering Relay Ratio Catalog Number* Rating Factor Catalog Number 0.15/0.3 @ Burden 0.15/0.3 Acc Range Rating Factor 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 D030200S1 D030300S1 D030400S1 D030500S1 D030600S1 D030800S1 D031000S1 D031200S1 D031500S1 D032000S1 D032500S1 D033000S1 D034000S1 D035000S1 0.3 B0.2 0.3 B0.5 0.3 B0.9 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C60 C100 C120 C150 C200 C300 C350 C400 C500 C600 C800 C800 C800 C800 3.0 3.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.1 --D030400X1 D030500X1 D030600X1 D030800X1 D031000X1 D031200X1 D031500X1 D032000X1 ----- --B0.5/B0.9 B0.5/B1.8 B0.9/B1.8 B0.9/B1.8 B1.8 B1.8 B1.8 B1.8 ----- --400/4 to 1200A 500/5 to 2000A 600/6 to 2400A 800/8 to 3200A 10 to 4000A 12 to 4800A 15 to 4500A 20 to 4000A ----- --3.0 4.0 4.0 4.0 4.0 4.0 3.0 2.0 ----- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 D030200D1 D030300D1 D030400D1 D030600D1 D031000D1 D031500D1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C60/C120 C100/C200 C150/C300 C200/C400 C300/C600 C400/C800 3.0/3.0 3.0/3.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 ------- ------- ------- ------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. * IC Approval AE-0703 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 13 15000 Volt March 2008 14 LG(X)–15–585 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG(X)–15–683 Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The LG(X)-15-683 outdoor, window-type current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 200:5 to 5,000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 4 ½” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. An optional primary bus bar with NEMA 4-hole pads can also be provided (5500A max). The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. accuracy performance The LG-15-683 will operate with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The LGX-15-683 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 up to B1.8. The transformer maintains 0.3 accuracy from 1% of Inom through its Rating Factor, and can be used continuously to this level (for 0.15 accuracy range, see ratings specific to each ratio). March 2008 mounting The LG is designed for mounting in the upright, underhung or cantilever position. Open end slots are provided on the aluminum mounting legs. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. options The LG is available with a primary bus bar kit or conductive bird guards to prevent foreign objects from entering the porcelain window. Contact factory for other needs. ORDERING INFO FOR LG-15-683 HIGH ACCURACY LGX-15-683 Accuracy/Burden Metering Relay Rating Factor Catalog Number 0.15/0.3 @ Burden 0.15/0.3 Acc Range Rating Factor Ratio Catalog Number* 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 D100200S1 D100300S1 D100400S1 D100500S1 D100600S1 D100800S1 D101000S1 D101200S1 D101500S1 D102000S1 D102500S1 D103000S1 D104000S1 D105000S1 0.3 B0.2 0.3 B0.5 0.3 B0.9 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C50 C100 C100 C150 C200 C200 C250 C250 C300 C400 C400 C800 C800 C800 3.0 3.0 3.0 3.0 3.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.1 --D100400X1 D100500X1 D100600X1 D100800X1 D101000X1 D101200X1 D101500X1 D102000X1 ----- --B0.5/B0.9 B0.5/B1.8 B0.9/B1.8 B0.9/B1.8 B1.8 B1.8 B1.8 B1.8 ----- --400/4 to 1200A 500/5 to 2000A 600/6 to 2400A 800/8 to 3200A 10 to 4000A 12 to 4800A 15 to 4500A 20 to 4000A ----- --3.0 4.0 4.0 4.0 4.0 4.0 3.0 2.0 ----- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 D100200D1 D100300D1 D100400D1 D100600D1 D101000D1 D101500D1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C50/C100 C100/C200 C100/C200 C200/C400 C200/C400 C400/C800 3.0/3.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 ------- ------- ------- ------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. * IC Approval AE-0745 for 2000:5 MR. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 15 15000 Volt March 2008 16 LG(X)–15–683 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG–15–879 Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying March 2008 application The LG-15-879 outdoor, window-type current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 200:5 to 10,000:5 for 60 Hertz (Hz) with a Rating Factor of up to 2.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 4 ½” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. An optional primary bus bar with NEMA 4-hole pads can also be provided (5500A max). The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. accuracy performance The LG-15-879 will operate with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube options The LG is available with a primary bus bar kit or conductive bird guards to prevent foreign objects from entering the porcelain window. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. ORDERING INFO FOR LG-15-879 Catalog Number Ratio 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 HIGH ACCURACY N/A Accuracy/Burden Metering Relay Rating Factor Catalog Number 0.15 Accuracy Range Rating Factor 6000:5 8000:5 10000:5 D092015S159-1 D093015S209-1 D094015S309-1 D096015S409-1 D098015S609-1 D091025S809-1 D091225S809-1 D091525S809-1 D092025S809-1 D092525S809-1 D093025S809-1 D094025S809-1 D095025S809-1 D096025S809-1 D098025S809-1 D091035S809-1 0.3 B0.1 0.3 B0.2 0.3 B0.5 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C150 C200 C300 C400 C600 C800 C800 C800 C800 C800 C800 C800 C800 C800 C800 C800 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.5 1.5 1.5 1.25 1.0 ----------------- ----------------- ----------------- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 D092015D109-1 D093015D209-1 D094015D309-1 D096015D409-1 D091025D409-1 D091525D809-1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C100/C200 C200/C400 C300/C600 C400/C800 C400/C800 C800/C800 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/1.5 ------- ------- ------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. - Available with a primary bar kit (maximum 5500A). Change last digit of catalog from 1 to 3. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 17 15000 Volt March 2008 18 LG–15–879 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage LG(X)–15–6513 Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Molded Resin, Window Type, Metering/Relaying application The LG(X)-15-6513 outdoor, window-type current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 400:5 to 10,000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a molded cast resin with a 8 ¾” window porcelain primary bushing to provide high withstand capabilities. The high strength porcelain has a semi conductive interior with a pigtail lead to be connected to the primary conductor to equalize the voltage and prevent radio interference and corona. The secondary terminals are ¼”-20 copper studs with associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs. March 2008 mounting The LG is designed for mounting in the upright or underhung position with the tube horizontal, or in the cantilever position with the tube vertical. CAUTION: Do not mount in the cantilever position with the tube horizontal, the base plate can collapse. Mounting holes are punched in the aluminum base plate. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. The unit is tested above operating voltage for traces of corona. A “corona free” label is bonded to the completed transformer as a guarantee of trouble-free service. accuracy performance The LG-15-6513 will operate with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8 and up to C800 for some relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The LGX-15-6513 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 up to B0.9. The transformer maintains 0.3 accuracy from 1% of Inom through its Rating Factor, and can be options used continuously to this level (for 0.15 accuracy range, see ratings The LG can be offered in single or dual core designs. Contact factory for other needs. specific to each ratio). ORDERING INFO FOR LG-15-6513 HIGH ACCURACY LGX-15-6513 Accuracy/Burden Metering Relay Rating Factor Catalog Number 0.15/0.3 @ Burden 0.15/0.3 Acc Range Rating Factor Ratio Catalog Number* 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 5000:5 6000:5 8000:5 10000:5 D040200S1 D040300S1 D040400S1 D040600S1 D040800S1 D041000S1 D041200S1 D041500S1 D042000S1 D042500S1 D043000S1 D044000S1 D045000S1 D046000S1 D048000S1 D0410000S1 0.3 B0.2 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.9 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C50 C100 C100 C150 C200 C250 C300 C300 C400 C600 C800 C800 C800 C800 C800 C800 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.5 1.5 1.0 1.0 1.0 --D040400X1 D040600X1 D040800X1 D041000X1 D041200X1 D041500X1 D042000X1 -------- --B0.5 B0.9 B0.9 B0.9 B0.9 B0.9 B0.9 -------- --400/4 to 1200A 600/6 to 2400A 800/8 to 3200A 100/10 to 3000A 120/12 to 3600A 150/15 to 3000A 200/20 to 4000A -------- --3.0 4.0 4.0 3.0 3.0 2.0 2.0 -------- 200/400:5 300/600:5 400/800:5 600/1200:5 1000/2000:5 1500/3000:5 2000/4000:5 3000/6000:5 D040200D1 D040300D1 D040400D1 D040600D1 D041000D1 D041500D1 D042000D1 D043000D1 0.3 B0.5/B0.9 0.3 B0.5/B1.8 0.3 B0.9/B1.8 0.3 B0.9/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 0.3 B1.8/B1.8 C100/C200 C200/C400 C300/C600 C150/C300 C200/C400 C400/C800 C400/C800 C400/C800 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/2.0 2.0/1.5 1.5/1.0 --------- --------- --------- --------- - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: 80x full winding Inom / Unlimited mechanical. * IC Approval (AE-1104) is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 19 15000 Volt March 2008 20 LG(X)–15–6513 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage COF(CXM)–110 Current Transformer 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, Metering/Relaying March 2008 application The COF(CXM)-110 outdoor current transformer is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are available from 5:5 to 3000:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0 (3200A max). This oil-filled current transformer will operate with high accuracy for metering or relay applications. mechanical description The tank dome is fabricated from carbon or stainless steel, depending on current rating. The units are pressure and vacuum tight and hermetically sealed at the factory to prevent breathing and oil contamination. Tank components are washed and coated with anticorrosive iron phosphate and then finished with ANSI 70 Gray baked-on electrostatic polyester powder. The bushing is ANSI 70 Gray, high strength porcelain with a high degree of stability for transportation and seismic withstand. The primary terminals are tin plated aluminum, NEMA 4-hole pads for units rated ≥400A (copper for units rated ≥2000A) and NEMA 2-hole pads for units rated <400A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. The secondary terminals are #10 slotted screws on a short circuiting terminal block located behind a removable cover in the CT base with three (3) 1 ½” NPT conduit hubs. The ground terminal is a stainless steel NEMA 2hole pad. The unit is fitted with a pressure relief valve, oil level gauge, and ½” drain valve. accuracy performance The COF-110 will operate with 0.3 Class accuracy for metering applications with burdens of B0.1 to B1.8. The unit can be designed with relay accuracy up to C800. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The CXM-110 will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. mounting The COF(CXM) is designed for mounting on substations structures in an upright position with four mounting holes in the base. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. options The COF(CXM) is available with an Extra Creep Bushing, Polymer Bushing, Stainless Steel Tank, 4kV Spark Gap and/or -50°C oil. The unit can be offered in single, dual or multiple core designs. Contact factory for other needs. ORDERING INFO FOR COF-110 HIGH ACCURACY CXM-110 Ratio Catalog Number Accuracy/ Burden Rating Factor Catalog Number 0.15 Accuracy Range Rating Factor 5:5 10:5 D950005SA D950010SA 0.3 B1.8 0.3 B1.8 1.5 1.5 D890005SA D890010SA 0.025 to 20A 0.05 to 40A 4.0 4.0 … … … … … … … 150:5 200:5 D950150SA D950200SA 0.3 B1.8 0.3 B1.8 1.5 1.5 D890150SA D890200SA 0.75 to 600A 1 to 800A 4.0 4.0 … … … D893000SA 15 to 3200A 1.07 5/10:5 10/20:5 D950010DA D950020DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 --------- --------- --------- … … 1.0 … … 0.3 B1.8 … … D953000SA … … 3000:5 100/200:5 150/300:5 D950200DA D950300DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 … … … … 1000/2000:5 1500/3000:5 D952000DA D953000DA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.0 - Available in multi-ratio designs (full tap ratings same as single ratio above). - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 21 15000 Volt March 2008 22 COF(CXM)–110 Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage KM–15–972 1 Ø Metering Unit 15000 Volt Outdoor 15kV, °110kV BIL, Single Ratios Molded Epoxy, Wound Type, 1Ø Metering March 2008 application The KM-15-972 outdoor, single phase metering unit is rated for use on 5,000 & 15,000 volt systems with °110kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). Primary voltage ratios are available from 20:1 to 70:1 for use on 5,000 & 15,000 volt, Grd Y systems. This dry-type, solid-cast metering unit will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The external line to ground insulation consists of a cycloaliphatic epoxy resin that provides excellent arc track properties in addition to ultraviolet resistance and strong physical strength. A high voltage stress ring around the top of the unit is supplied to control RIV and partial discharge. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware located inside a removable terminal box with two (2) 1” NPT conduit hubs and a 1” knockout on the bottom of the box. accuracy performance The KM-15-972 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT is accurate from 90% to 110% of rated primary voltage. mounting The KM is designed for mounting on poles or substation structures in an upright, underhung or cantilever position. The mounting holes in the heavy galvanized steel plate are punched to industry standard dimensions for interchangeability in the field. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options A primary spark gap is available for capacitor bank or other applications where high transients will be present. 90° angle primary bus adapters can be supplied to place the two terminal surfaces parallel to one another. Contact factory for other needs. ORDERING INFO FOR KM-15-972 HIGH ACCURACY N/A Voltage Ratings Ratio* - 60:1 Pri*°:Sec - 7200:120 Current Ratio Catalog Number** Accuracy/ Burden Rating Factor Catalog Number* Accuracy/ Burden Rating Factor 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 300:5 400:5 600:5 800:5 1000:5 1200:5 D9800505S060S D9801005S060S D9801505S060S D9802005S060S D9802505S060S D9803005S060S D9804005S060S D9805005S060S D9807505S060S D9801015S060S D9801515S060S D9802015S060S D9803015S060S D9804015S060S D9805015S060S D9808015S060S D9801025S060S D9801225S060S 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.0 1.5 1.2 1.0 ------------------- ------------------- ------------------- Accuracy/Burden 0.3 0,W,X,M,Y 1.2 Z Accuracy/Burden -- - Thermal Burden Rating (Typical): 750VA. - Overvoltage Rating: 1.25x cont., 1.5x 30 sec. - 1 Second Thermal/Mechanical Rating: 150x/300x Inom (100x/200x for 600:5, 75x/150x for above 600:5). * Other Primary Voltage Ratings Available, contact factory. ° Units with less than 5kV primary voltage are rated 60kV BIL (catalog number will begin with “B”). ** IC Approval AE-1473 is noted by bold catalog number. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 23 15000 Volt March 2008 24 KM–15–972 1 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage JS(JXM)–110 1Ø Metering Unit 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 1Ø Metering voltage. The JXM-110 will operate, for the current transformer, with 0.15 Class accuracy for metering with burdens of B0.1 to B1.8. The CT maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT is accurate from 90% to 110% of rated primary voltage. application The JS(JXM)-110 outdoor single phase metering unit is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 4.0 (1200A max). Primary voltage ratios are available from 20:1 to 70:1 for use on 5,000 & 15,000 volt, Grd Y systems. This oil-filled metering unit will operate with high accuracy for metering applications. mechanical description The tank is a standard distribution transformer tank made of heavy gauge sheet steel with a seam welded bottom plate and a dome shaped cover. The tank is washed and coated with anticorrosive iron phosphate and then finished with an ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with a tin plated bronze, NEMA 1-hole primary terminal. NEMA 4-hole primary terminals are provided for units rated ≥200A. A bypass protector is provided for all units rated below 1200:5 to protect from transients. A 5kV H0 Bushing is included for power factor measurements and is connected to the tank ground, a tin plated bronze eyebolt. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a removable terminal box with three (3) 1 ½” NPT conduit hubs. The unit also includes a pressure relief valve. mounting The JS(JXM) is designed for mounting on poles or substation structures in an upright position with ANSI type “A” hanger brackets or optional mounting feet. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. accuracy performance The JS-110 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M, Y, Z and ZZ. The VT is accurate from 90% to 110% of rated primary ORDERING INFO FOR JS-110 Ratio* - 60:1 Voltage Ratings Pri*:Sec - 7200:120 March 2008 options The JS(JXM) is available with Lighting Arrestors, NEMA 4-hole Primary Terminals, NEMA 2-hole Ground Pad, Mounting Feet, Stainless Steel Tank, 4kV Spark Gap, Oil Level Indicator, Oil Drain Valve, and/or -50°C oil. Contact factory for other needs. Accuracy/Burden 0.3 0,W,X,M,Y,Z,ZZ HIGH ACCURACY JXM-110 Accuracy/Burden 0.15 0,W,X,M,Y,Z, 0.3 ZZ Current Ratio Catalog Number Accuracy/ Burden Rating Factor Catalog Number 0.15 B1.8 Acc Range Rating Factor 10:5 20:5 D80001S06EA D80002S06EA 0.3 B1.8 0.3 B1.8 1.5 1.5 D79001S06EA D79002S06EA 0.05 to 40A 0.1 to 80A 4.0 4.0 … … … … … … … 150:5 200:5 D80015S06EA D80020S06EA 0.3 B1.8 0.3 B1.8 1.5 1.5 D79015S06EA D79020S06EA 0.75 to 600A 1 to 800A 4.0 4.0 … … … D79100S06EA D79120S06EA 5 to 1200A 6 to 1200A 1.2 1.0 5/10:5 10/20:5 D80001D06EA D80002D06EA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 ------ ------ ------ … … 1.2 1.0 … … 0.3 B1.8 0.3 B1.8 … … D80100S06EA D80120S06EA … … 1000:5 1200:5 500/1000:5 600/1200:5 D80100D06EA D80120D06EA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.2 2.0/1.0 - Available in multi-ratio designs. - Thermal Burden Rating (Typical): 4000VA. - Overvoltage Rating: 1.1x cont., 1.9x 8 hours. - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * Other Primary Voltage Ratings Available, contact factory. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 25 15000 Volt March 2008 26 JS(JXM)–110 1Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MVCT(MXM)–110 3 Ø Metering Unit 15000 Volt Outdoor 15kV, 110kV BIL, Single, Dual & Multi Ratios Oil-Filled, Wound Type, 3Ø Metering March 2008 transformers, with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B1.8. The transformer maintains 0.15 Class accuracy from 0.5% of Inom through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.15 Class accuracy for metering with burdens of 0, W, X, M, Y and Z, as well as 0.3 ZZ. The VT’s are accurate from 90% to 110% of rated primary voltage. application The MVCT(MXM)-110 outdoor three phase metering unit is rated for use on 15,000 volt systems with 110kV BIL. Primary current ratios are 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 4.0 (1200A max). Primary voltage ratios are available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems. This oilfilled metering unit will operate with high accuracy for 2, 2 ½ or 3 element metering applications. mechanical description The unit is built of heavy walled steel construction similar to proven distribution and small power transformer construction and is strongly braced to withstand both electrical and mechanical stresses. The tank is washed and coated with anticorrosive iron phosphate and then finished with an ANSI 70 Gray baked-on electrostatic polyester powder. The primary bushings are ANSI 70 Gray, high strength porcelain with tin plated bronze, NEMA 4-hole primary terminals. The secondary terminals consist of a feed thru block with ¼”-20 copper studs and associated hardware located inside a terminal box with three (3) 1 ½” NPT conduit hubs. The ground terminal is a stainless steel NEMA 2-hole pad. The unit includes a pressure relief valve, CT by-pass protectors, 5kV H0 Bushing (for 3P 4W designs), ½” oil drain valve, and a magnetic type oil level gauge which is easily read from a distance. mounting The MVCT(MXM) is designed for overhead mounting on poles or substation structures in an upright position with ANSI type “C” hanger brackets or four mounting holes in the base. NOTE: Must be installed per NESC electrical clearances. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Additional tests include dissipation and partial discharge tests. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 135% of the nominal system voltage. accuracy performance The MVCT-110 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of options 0, W, X, M, Y, Z and ZZ. The VT’s are accurate from 90% to 110% The MVCT(MXM) is available with a Stainless Steel Tank, 4kV of rated primary voltage. The MXM-110 will operate, for the current Spark Gaps and/or -50°C oil. Contact factory for other needs. ORDERING INFO FOR MVCT-110 HIGH ACCURACY MXM-110 Voltage Ratings Ratio* - 60:1 Pri*:Sec - 7200:120 Current Ratio Catalog Number (3P 4W)** Accuracy/ Burden Rating Factor Catalog Number (3P 4W) 0.15 B1.8 Acc Range Rating Factor 10:5 20:5 D88001S06CA D88002S06CA 0.3 B1.8 0.3 B1.8 1.5 1.5 D86001S06CA D86002S06CA 0.05 to 40A 0.1 to 80A 4.0 4.0 Accuracy/Burden 0.3 0,W,X,M,Y,Z,ZZ Accuracy/Burden 0.15 0,W,X,M,Y,Z, 0.3 ZZ … … … … … … … 150:5 200:5 D88015S06CA D88020S06CA 0.3 B1.8 0.3 B1.8 1.5 1.5 D86015S06CA D86020S06CA 0.75 to 600A 1 to 800A 4.0 4.0 … … … D86100S06CA D86120S06CA 5 to 1200A 6 to 1200A 1.2 1.0 5/10:5 10/20:5 D88001D06CA D88002D06CA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.5 2.0/1.5 ------ ------ ------ … … 1.2 1.0 … … 0.3 B1.8 0.3 B1.8 … … D88100S06CA D88120S06CA … … 1000:5 1200:5 500/1000:5 600/1200:5 D88100D06CA D88120D06CA 0.3 B1.8/B1.8 0.3 B1.8/B1.8 2.0/1.2 2.0/1.0 - Available in multi-ratio designs. - Thermal Burden Rating (Typical): 6000VA (2000VA/phase). - Overvoltage Rating: 1.1x cont., 1.9x 8 hours (3P 4W). - 1 Second Thermal/Mechanical Rating: Single Ratio (150x lnom), Dual Ratio (75x full winding Inom), 144kA max. * Other Primary Voltage Ratings Available, contact factory. ** For 3P 3W, change catalog digits “88” to “87”. - IC Approval AE-0753 Rev. 2 noted by bold catalog number (also 50/100:5 and 150/300:5 ratios). Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 27 15000 Volt March 2008 28 MVCT(MXM)–110 3 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage ME–015 3 Ø Metering Rack Outdoor 15kV, °110kV BIL, Single & Dual Ratios Pre-Wired, Molded Epoxy CTs & VTs, 3Ø Metering 15000 Volt March 2008 application The ME-015 outdoor, three phase metering rack is rated for use on 5,000 & 15,000 volt systems with °110kV BIL. Current transformers have ratios available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). Voltage transformers have ratios available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems. This metering rack will operate with high accuracy for 1, 2, 2 ½ or 3 element metering applications. mechanical description The rack is made of lightweight aluminum and incorporates the BB-15-971 or BB-15-972 current transformers mounted vertically and the PTT-110-977(G) or PTT-110-9710(G) voltage transformers mounted horizontally. The CT primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The VT primary terminals are M12 stud with a compression type lug for #8 - #2 AWG conductors. The secondary terminals are pre-wired through protective conduit to a 10 position testing The units are individually tested per the IEEE C57.13 standard, test switch in standard red/black colors mounted to the rack. including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units accuracy performance The ME-015 will operate, for the current transformers, with 0.3 are free of partial discharge through 120% of the nominal system Class accuracy for metering with burdens of B0.1 up to B1.8. The voltage. The secondary pre-wiring is tested for correct polarity and CT’s are accurate through their Rating Factor, and can be used type of transformer to minimize damage due to misconnection. continuously to this level. The rack will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens options of 0, W, X, M, Y and up to Z. The VT’s are accurate from 90% to The ME rack is available with a 35’ S/O outdoor cable extension to a test switch/meter socket, a pre-programmed GE type KV2C Form 110% of rated primary voltage. 9S meter, and/or Canadian color-code or other color scheme wiring. CT’s and/or VT’s are available with 0.15 Class high accuracy. mounting The ME rack is designed for mounting on poles in an upright Transformers can be mounted with the VT’s vertical and CT’s position. There are two galvanized steel mounting bolts supplied horizontal, or rack can be designed with only VT’s or only CT’s. Contact factory for other needs. to attach to the pole. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 29 15000 Volt March 2008 30 ME–015 3 Ø Metering Rack NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MK–15 3 Ø Metering Rack Outdoor 15kV, °110kV BIL, Single Ratios Pre-Wired, Molded Epoxy CT/VTs, 3Ø Metering 15000 Volt March 2008 application The MK-15 outdoor, three phase metering rack is rated for use on 5,000 & 15,000 volt systems with °110kV BIL. Primary current ratios are available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). Primary voltage ratios are available from 20:1 to 70:1 for use on 5,000 & 15,000 volt, Grd Y systems. This metering rack will operate with high accuracy for 1, 2 or 3 element metering applications. mechanical description The rack is made of lightweight aluminum and incorporates the KM15-972 metering units mounted either vertically or horizontally. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The secondary terminals are pre-wired through protective conduit to a 10 position test switch in standard red/black colors mounted to the rack. accuracy performance The MK-15 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The rack will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The MK rack is designed for mounting on poles in an upright position. There are two galvanized steel mounting bolts supplied to attach to the pole. testing The units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The MK rack is available with a 35’ S/O outdoor cable extension to a test switch/meter socket, a pre-programmed GE type KV2C Form 9S meter, and/or Canadian color-code or other color scheme wiring. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 31 15000 Volt March 2008 32 MK–15 3 Ø Metering Rack NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MP–015 3 Ø Metering Cubicle Outdoor 15kV, °110kV BIL, Single & Dual Ratios Pre-Wired, Molded Epoxy CTs & VTs, 3Ø Metering 15000 Volt March 2008 application The MP-015 outdoor, three phase metering, pad-mounted cubicle is rated for use on 5,000 & 15,000 volt systems with °110kV BIL and also complies with ANSI C57.12.28. Current transformers have ratios available from 5:5 to 1200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (1200A max). Voltage transformers have ratios available from 20:1 to 120:1 for use on 5,000 & 15,000 volt systems. This metering cubicle will operate with high accuracy for 1, 2, 2 ½ or 3 element metering applications. mechanical description The cubicle is made of #12 AWG mild steel with Munsell Green #7GY 3.29/1.5 powder finish and incorporates the BB-15-971 or BB-15-972 current transformers and the PTT-110-977(G) or PTT-110-9710(G) voltage transformers. The cubicle doors are pad-lockable with three point latch and a penta-head bolt and have screened vents on the transformer side. White GPO-3 glass reinforced polyester barriers are built-in between phases and the live side. The primary connections can be radial or loop feed with one or two load taps. The connections can be either 200A loadbreak bushing wells or 600A non-loadbreak inserts, both are ANSI/IEEE 386 compliant. The secondary terminals are prewired to a 10 position test switch and 9S meter socket in standard red/black colors on the outside right wall when facing the elbow side of the cubicle. accuracy performance The MP-015 will operate, for the current transformers, with 0.3 Class accuracy for metering with burdens of B0.1 up to B1.8. The CT’s are accurate through their Rating Factor, and can be used continuously to this level. The cubicle will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens of 0, W, X, M, Y and up to Z. The VT’s are accurate from 90% to 110% of rated primary voltage. mounting The MP cubicle is designed for pad-mount use. testing The transformer units are individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to guarantee the units are free of partial discharge through 120% of the nominal system voltage. The secondary pre-wiring is tested for correct polarity and type of transformer to minimize damage due to misconnection. options The MP cubicle is available with the test switch on the inside wall of the cubicle to allow wiring to a remote meter socket. Unit is also available with only CT’s or VT’s. Canadian color-code or other color scheme wiring can be provided. CT’s and/or VT’s are available with 0.15 Class high accuracy. Contact factory for other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 33 15000 Volt March 2008 34 MP–015 3 Ø Metering Cubicle NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage U/VCD–17(H) Voltage Transformer Indoor 15kV, 95kV BIL, Single & Dual Ratios Molded Epoxy, Wound Type, Metering/Relaying 15000 Volt March 2008 application The U/VCD-17(H) indoor voltage transformer is rated for use on 15,000 volt systems with 95kV BIL. Primary voltage ratios are available from 60:1 to 120:1 for use on 15,000 volt systems, at 60 Hertz (Hz). This dry-type, solid-cast voltage transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The primary terminal(s) are screw-type, tin-plated, for #12 to #8 AWG conductors. The secondary terminals are ¼”-20 slotted screws and associated hardware embedded in epoxy resin on the front side of the transformer. In addition, a ground terminal is provided near the secondary terminals on the base plate. accuracy performance The U/VCD-17 will operate with 0.3 Class accuracy for metering and relay applications with burdens of 0, W, X, M, Y and Z. The transformer is accurate from 90% to 110% of rated primary voltage. The U/VCD-17H will operate with 0.15 Class high accuracy for metering applications with burdens of 0, W, X, M and Y. The transformer is accurate from 90% to 110% of rated primary voltage. mounting The U/VCD is designed for mounting inside switchgear or other indoor applications in an upright, underhung or cantilever position. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Units are available in single or double bushing models. The VCD-17H high accuracy voltage transformer is only available in the double bushing model. Primary terminal(s) can be equipped with fuse clip(s) and fuse(s). The unit can be offered in switchgear format with primary terminal(s) toward the back. Contact factory for other needs. ORDERING INFO FOR U/VCD-17 Ratio Primary Secondary 60:1 63.5:1 70:1 100:1 110:1 120:1 7200 7620 8400 12000 13200 14400 120 120 120 120 120 120 HIGH ACCURACY VCD-17H Catalog Number 1 Bushing 2 Bushing D916G060S0 D916G063S0 D916G070S0 ---- D916060S0 D916063S0 D916070S0 D916100S0 D916110S0 D916120S0 Accuracy/ Burden Catalog Number 2 Bushing Only Accuracy/ Burden 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z 0.3 0,W,X,M,Y,Z D916060E0 D916063E0 D916070E0 D916100E0 D916110E0 D916120E0 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y 0.15 0,W,X,M,Y - Thermal Burden Rating (Typical): Std Acc. (1500VA), High Acc. (1000VA). - Overvoltage Rating: 1.1x cont. - For fuse clips, add a “C” per clip needed at the end of the catalog. - For fuses, add an “F” per fuse needed at the end of the catalog. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 35 15000 Volt March 2008 36 U/VCD–17(H) Voltage Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage CID–17(H) Current Transformer Indoor 15kV, 95kV BIL, Single & Dual Ratios Molded Epoxy, Wound Type, Metering/Relaying 15000 Volt March 2008 application The CID-17(H) indoor current transformer is rated for use on 15,000 volt systems with 95kV BIL. Primary current ratios are available from 5:5 to 1200:5 at 60 Hertz (Hz) with a Rating Factor of up to 1.5. This dry-type, solid-cast current transformer will operate with high accuracy for metering or relay applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The primary terminals are flat, tin-plated copper with standard NEMA 2-hole pattern suitable for various size conductors. The clamp-type post secondary terminals have ¼”-20 slotted screws and associated hardware embedded in epoxy resin on the front side of the transformer. The ground terminal is provided near the secondary terminals on the base plate. accuracy performance The CID-17 will operate with 0.3 Class accuracy for metering with burdens of B0.1 to B1.8 and C200 for relay applications. The transformer is accurate through its Rating Factor, and can be used continuously to this level. The CID-17H will operate with 0.15 Class high accuracy for metering applications with burdens of B0.1 to B0.5. The transformer maintains 0.15 accuracy from 10% (0.3 accuracy from 2%) of Inom through its Rating Factor, and can be used continuously to this level. mounting The CID is designed for mounting inside switchgear or other indoor applications in an upright, underhung or cantilever position. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Contact factory for other needs. ORDERING INFO FOR CID-17 Ratio Catalog Number 5:5 10:5 D9150005S0 D9150010S0 HIGH ACCURACY CID-17H Accuracy/Burden Metering Relay 0.3 B1.8 0.3 B1.8 C200 C200 Rating Factor Catalog Number Accuracy/ Burden Rating Factor 1.5 1.5 D9150005E0 D9150010E0 0.15 B0.5 0.15 B0.5 1.5 1.5 … … … … … … … … 50:5 75:5 100:5 D9150050S0 D9150075S0 D9150100S0 0.3 B1.8 0.3 B1.8 0.3 B1.8 C200 C200 C200 1.5 1.5 1.5 D9150050E0 D9150075E0 D9150100E0 0.15 B0.5 0.15 B0.5 0.15 B0.5 1.5 1.5 1.5 … … … … … … … … 600:5 800:5 1000:5 1200:5 D9150600S0 D9150800S0 D9151000S0 D9151200S0 0.3 B1.8 0.3 B1.8 0.3 B1.8 0.3 B1.8 C200 C200 C200 C200 1.5 1.1 1.1 1.1 D9150600E0 D9150800E0 D9151000E0 D9151200E0 0.15 B0.5 0.15 B0.5 0.15 B0.5 0.15 B0.5 1.5 1.1 1.1 1.1 5/10:5 10/20:5 D9150005D0 D9150010D0 0.3 B0.5/B1.8 0.3 B0.5/B1.8 C100/C200 C100/C200 2.0/1.5 2.0/1.5 D9150005F0 D9150010F0 0.15 B0.2/B0.5 0.15 B0.2/B0.5 2.0/1.5 2.0/1.5 … … … … … … … … 300/600:5 400/800:5 500/1000:5 600/1200:5 D9150300D0 D9150400D0 D9150500D0 D9150600D0 0.3 B0.5/B1.8 0.3 B0.5/B1.8 0.3 B0.5/B1.8 0.3 B0.5/B1.8 C100/C200 C100/C200 C100/C200 C100/C200 2.0/1.5 1.1/1.1 1.1/1.1 1.1/1.1 D9150300F0 D9150400F0 D9150500F0 D9150600F0 0.15 B0.2/B0.5 0.15 B0.2/B0.5 0.15 B0.2/B0.5 0.15 B0.2/B0.5 2.0/1.5 1.1/1.1 1.1/1.1 1.1/1.1 - 1 Second Thermal/Mech Rating Min: 90x/240x Inom (66kA/178kA for above 600:5 & 300/600:5). Contact factory for actuals. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 37 15000 Volt March 2008 38 CID–17(H) Current Transformer NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage KCB–17 1 Ø Metering Unit 15000 Volt Indoor 15kV, °95kV BIL, Single Ratios Molded Epoxy, Wound Type, 1Ø Metering March 2008 application The KCB-17 indoor, dead-front, single phase metering unit is rated for use on 5,000 & 15,000 volt systems with °95kV BIL. Primary current ratios are available from 5:5 to 200:5 at 60 Hertz (Hz) with a Rating Factor of up to 3.0. Primary voltage ratios are available for 20:1 to 70:1 for use on 5,000 & 15,000 volt, Grd Y systems. This dry-type, solid-cast metering unit will operate with high accuracy for metering applications. mechanical description The core and coil assembly is wound and encapsulated in a high dielectric strength epoxy resin to provide high withstand capabilities. The entire surface of the transformer is coated with a conductive layer that is intended to be solidly grounded when energized. This allows for compact mounting inside switchgear or enclosures. The primary terminals are standard 200 Ampere rated dead-front bushing well construction and can be connected using industry standard inserts and elbow connectors. The secondary terminals are ¼”-20 slotted screws with flat and lock washers located inside a metallic terminal cover with two (2) 1” NPT conduit hubs, one sealed and one left open for conduit entrance. The ground terminal is provided inside the terminal cover along with a manually operated CT secondary shorting device for safety purposes. accuracy performance The KCB-17 will operate, for the current transformer, with 0.3 Class accuracy for metering with burdens of B0.1 to B0.5. The CT is accurate through its Rating Factor, and can be used continuously to this level. The unit will operate, for the voltage transformer, with 0.3 Class accuracy for metering with burdens of 0, W, X, M and Y. The VT is accurate from 90% to 110% of rated primary voltage. mounting The KCB is designed for mounting inside switchgear, pad-mounted enclosures, or vault applications. testing The unit is individually tested per the IEEE C57.13 standard, including applied and induced voltage, accuracy and polarity. Partial discharge testing is performed to guarantee the unit is free of partial discharge through 120% of the nominal system voltage. options Unit is also available as a CT or VT only. Contact factory for other needs. ORDERING INFO FOR KCB-17 HIGH ACCURACY N/A Voltage Ratings Ratio* - 60:1 Pri*°:Sec - 7200:120 Current Ratio Catalog Number Accuracy/ Burden Rating Factor Catalog Number* Accuracy/ Burden Rating Factor 5:5 10:5 15:5 20:5 25:5 30:5 40:5 50:5 75:5 100:5 150:5 200:5 D9900505S060S D9901005S060S D9901505S060S D9902005S060S D9902505S060S D9903005S060S D9904005S060S D9905005S060S D9907505S060S D9901015S060S D9901515S060S D9902015S060S 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 0.3 B0.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.67 2.0 1.33 1.0 ------------- ------------- ------------- Accuracy/Burden 0.3 0,W,X,M,Y 1.2 Z Accuracy/Burden -- - Thermal Burden Rating (Typical): 750VA. - Overvoltage Rating: 1.1x cont. - 1 Second Thermal/Mechanical Rating: 100x/270x Inom. * Other Primary Voltage Ratings Available, contact factory. ° Units with less than 5kV primary voltage are rated 60kV BIL (catalog number will begin with “B”). Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 39 15000 Volt March 2008 40 KCB–17 1 Ø Metering Unit NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage MI–15 3 Ø Metering Cubicle Outdoor 15kV, °95kV BIL, Single Ratios Pre-Wired, Molded Epoxy CT/VTs, 3Ø Metering 15000 Volt March 2008 application The MI-15 outdoor, three phase metering, pad-mounted cubicle is rated for use on 15,000 volt systems with °95kV BIL and also complies with ANSI C57.12.28. Current transformers have ratios available from 5:5 to 200:5 for 60 Hertz (Hz) with a Rating Factor of up to 3.0 (200A max). Voltage transformers have ratios available for 20:1 to 70:1 for use on 5,000 & 15,000 volt, Grd Y systems. This metering cubicle will operate with high accuracy for 1, 2 or 3 element metering applications. mechanical description The cubicle is made of #12 AWG stainless steel with Munsell Green #7GY 3.29/1.5 powder finish and incorporates the KCB-17 metering units. The cubicle doors are pad-lockable with a three point latch and a penta-head bolt and have screened vents on the removable transformer side door. The primary connections are radial with one load tap (loop feed configuration may be available by use of feed-through inserts). The connections are 200A loadbreak bushing wells, which are ANSI/IEEE 386 compliant. The secondary terminals are pre-wired to a 10 position test switch testing and 9S meter socket in standard red/black colors on the outside The transformer units are individually tested per the IEEE C57.13 right wall when facing the elbow side of the cubicle. standard, including applied and induced voltage, accuracy and polarity. An additional partial discharge test is performed to accuracy performance guarantee the units are free of partial discharge through 120% of The MI-15 will operate, for the current transformers, with 0.3 the nominal system voltage. The secondary pre-wiring is tested Class accuracy for metering with burdens of B0.1 to B0.5 The for correct polarity and type of transformer to minimize damage CT’s are accurate through their Rating Factor, and can be used due to misconnection. continuously to this level. The cubicle will operate, for the voltage transformers, with 0.3 Class accuracy for metering with burdens options of 0, W, X, M and Y. The VT’s are accurate from 90% to 110% of The MI cubicle is available with a terminal block on the inside rated primary voltage. wall of the cubicle to allow wiring to a remote meter socket. Unit is also available with only CT’s or VT’s. Canadian color-code or mounting other color scheme wiring can be provided. Contact factory for The MI cubicle is designed for pad-mount use. other needs. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage 41 15000 Volt March 2008 42 MI–15 3 Ø Metering Cubicle NOTE: OUTLINES ARE FOR REFERENCE ONLY. CONTACT FACTORY FOR ACTUAL DESIGN DRAWINGS. Dry type: 3022 NC 43 North • Pinetops, NC 27864 • Phone: +1 252 827-3212 • www.abb.com/mediumvoltage Oil type: 101 Kuhlman Blvd • Versailles, Kentucky 40383 • Phone: +1 859 879-2999 • www.abb.com/highvoltage
© Copyright 2024 Paperzz