Integrated measuring systems for the whole water cycle Open Channel Flowmeter ® MainFLO Measures from 0,01 to 5 m/s Bi-directionnal velocity measurement RS232 & Bluetooth communication Portable version Up to 12 months battery life Flow measurement possible in very shallow water Velocity measurement with internal temperature measurement and real time speed of sound correction Application The MainFLO Doppler flowmeter measures and records flows for open channels and part-filled pipes. The MainFLO is used: Either in portable configuration, for survey and diagnostic work, for precise flow data in sewer networks, Or in fixed configuration, for regulatory works and overflow survey. The MainFLO is used for the following applications: Sewers and waste water treatment plants, Irrigation canals and channels, Rivers and streams. Main features The MainFLO embeds a CPU, a level sensor and a velocity sensor: Level is measured by ultrasonic probe or using a piezo-resistive sensor, Velocity is measured by a Doppler-effect velocity sensor. The MainFLO is the only flowmeter that measures actual mean velocity: Accurate measurement, irrespective of downstream effect, Constant performance in stable conditions or in transient conditions. Suitable for infiltration water measurement, due to its signal quality at low velocities, down to 1 cm/s. All our sensors are calibrated on our own calibration benches, with COFRAC interface. Various installations With hooping and spreader Portable MainFLO® Unit On rectangular channel Doppler Velocity Probe * (DVP) With floating support Stationary MainFLO® Unit * The Doppler Velocity Probe (DVP) can be used independently. For further information, please contact us. Measurement principle Level: by pressure measurement Using a piezo-resistive level probe. Velocity: by Doppler system Using a Doppler-effect velocity sensor. An ultrasonic beam is emitted, along the pipe interior, by an immersed probe. The ultrasonic signals are reflected by the suspended particles in the water. The reflected signals are then analysed to determine the mean water velocity. Technical specifications Display 128 * 64 dot matrix display of real time data Logged data Micro SD card [4 GB] non-volatile flash memory (Based on a measurement every 2 minutes, usage is 20kBytes per day) Separate file for each day. Each record is: Velocity, Level, Flow, Flow Quality, Temperature, Speed of Sound Internal Power Supply Battery 7 Ah (optional 12 Ah) lead acid battery Battery life Typically 6 months for 7 Ah battery with a reading every 2 minutes Actual autonomy will be reduced by excessive use of display and Bluetooth External Power Supply Mains supply For long term requirements and trickle charging of battery: 9 – 28 VDC Memory Data Logging Real Time Clock 6 mA at 12 VDC on standby, 40 mA at 12 VDC for measurement plus any battery charging required 2 * contact closure outputs can be used as alarms or dosing output 4 * 4-20mA outputs Integral clock with backup power for 20 minutes if no main battery or external power Digital Connection RS232 and integral Bluetooth Consumption Outputs Portable Settings Area-velocity calculation for flow. If velocity measurement quality is poor or velocity sensor not fitted then flow calculation is based on level and stage characteristics Delayed Start, Sampling Cycle Time, Alarms, Dosing, Units, Level Calibration, Stage Calibration, Bluetooth Control, Display Control, Language MainFLO® Unit Software MainFLO software Operating temperature -20 to +60 °C (-4°F to 140°F) Enclosure Rugged Copolymer Polypropylene carrying case Dimensions 124mm (4.88 in) * 246mm (9.68 in) * 270mm (10.63 in) Weight 5 kg Immersion IP67 Warranty 24 months Flow Calculation Display 128 * 64 dot matrix display of real time data Data Logging Logged data Power Supply 9-28Vdc Outputs 2 * contact closure outputs can be used as alarms or dosing output 4 * 4-20mA outputs Digital Connection RS232 and integral Bluetooth Settings Area-velocity calculation for flow. If velocity measurement quality is poor or velocity sensor not fitted then flow calculation is based on level and stage characteristics Delayed Start, Sampling Cycle Time, Alarms, Dosing, Units, Level Calibration, Stage Calibration, Bluetooth Control, Display Control, Language Software MainFLO software Operating temperature -20 to +60°C Enclosure Aluminum Dimensions 82mm (3.23 in) high * 150mm (5.91 in) wide * 222mm (8.74 in) long Weight 2,5kg Immersion IP67 Warranty 24 months Flow Calculation Stationary MainFLO® Unit Micro SD card [4 GB] non-volatile flash memory (Based on a measurement every 2 minutes, usage is 20kBytes per day) Separate file for each day. Each record is: Velocity, Level, Flow, Flow Quality, Temperature, Speed of Sound Velocity Measuring principle DSP Doppler using twin 1 MHz transducers Range Bi-directional 0.01 to 5 m/s (0.03 to 16.4 ft/s) Accuracy ± 2 % of reading if V ≥0.5m/s ± 0.01 m/s (± 0.03 ft/s) if V<0.5m/s Resolution 1 mm/s (0.003ft/s) 15 mm (0.59 in) to 20mm (0.79in) above base of sensor, provided transducers Minimum fluid level fully wetted Temperature Doppler Velocity Probe (DVP) Units m/s or ft/s Range -10 ºC to +85 ºC (14°F to 185°F) Accuracy ± 0.5 ºC (± 0.9°F) Resolution 0.5 ºC (0.9°F) Speed of Sound Correction Fixed or Variable Operating temperature -20 to +60 °C (-4°F to 140°F) Enclosure Polyurethane, PVDF, 316 Stainless steel Dimensions 19 mm (0.75 in) high * 46 mm (1.81 in) wide * 122 mm (4.80 in) long Weight <1,1 kg for 10 meters (32,8 ft) cable Immersion IP68 / NEMA6 Certification ATEX and IECEx Warranty 24 months Range Typically mounted on DVP mounting plate, but can be located separately to suit installation. 0-150mBar or 0-350mBar Other range in option – ATEX version in option Accuracy 0,1% FS Measuring principle Piezo-resistive sensor Option Level Ultrasonic sensor Available on stationary version Products available for sales and rental. Please contact us for more information. Head office: 34, route de Saint Romain 69450 Saint Cyr au Mont d’Or France Limonest site: 1, chemin des Vergers – Bât 2A 69760 Limonest France Tél. +33 (0)4 72 53 11 53 - Fax +33 (0)4 78 83 44 37 - E-mail : [email protected] MainFLO – V.2 – EN - 09/15 – Hydreka reserves the right to modify product technical characteristics without notice – Non-contractual pictures Memory
© Copyright 2026 Paperzz