FALCON High Flow Circular ceiling air diffuser for supply air QUICK FACTS ○○ Ceiling air diffuser for supply air in rooms with high ceiling ○○ Manual operated change of spread direction as standard ○○ Motor operated change of spread direction as accessory ○○ Same total pressure drop for horizontal and vertical spread ○○ Suitable for heating and cooling of rooms ○○ Standard whit RAL 9003 ○○ Five alternative standard colours AIR FLOW - SOUND LEVEL FALCON High Flow 25 dB(A) 30 dB(A) 35 dB(A) Size l/s m3/h l/s m3/h l/s m3/h 315 400 500 348 534 923 1253 1922 3323 402 618 1080 1447 2225 3888 464 716 1261 1670 2578 4540 Horizontal spread, cooling. FALCON High Flow Technical description Design • The FALCON HF consists of two parts: an outer cone with rubber ring sealed-fitted spigot and an aerodynamically designed outlet cone. NOTE! Size 500 is delivered without a rubber seal ring. • As standard the outlet cone is manually operated when changing the spread direction. Materials and finish • The entire air diffuser is made of sheet steel and its interior and exterior surfaces are painted in our standard white colour: RAL 9003/NCS S 0500-N. • Alternative standard colours: -RAL 9010, white -RAL 9006, white aluminium -RAL 7037, dusty grey -RAL 9007, grey aluminium -RAL 9005, jet black • Non-painted and other colours upon request. Accessories Electrical motor • 2 point regulation to change the spread to horizontal/ vertical direction. Control unit for switching from cooling/heating • VHC control unit switches the mode of motor controlled air diffusers, intended for both under-tempered and over- tempered supply air. The controlling parameter is the temperature difference between supply air and extract air. Installation • Secure the inlet spigot to the connecting duct using blind rivets. Maintenance • The air diffuser can be cleaned, if necessary, using lukewarm water with dishwashing detergent added. • Alternatively by vacuum cleaning using a brush nozzle. Wiring Diagram Belimo LM24A alt. Belimo LM230A Figure 1. Wiring diagram for FALCON HF, motor control with 2 point regulation. Switch is not included. Motor features Motor LM24A LM230A 2 Supply voltage 24 V AC 50/60 Hz 24 V DC AC 100..240V 50/60 Hz Power consumption Running time / Torque 2 VA 150 s / 5 Nm 4 VA 150 s / 5 Nm Swegon reserves the right to alter specifications. 20150217 FALCON High Flow Sizing air supply. A throw of l0,2 is provided for all Swegon's air diffusers. • The diagrams provide data for a FALCON HF placed in a ceiling. • The sound level is given in dB(A) for products in rooms and applies to rooms with 10 m² equivalent sound absorption area (normal acoustic absorption of 4 dB). • Throw length l0,2 is measured at isothermal air supply. • Recommended max. permissible temperature below room temperature is 10K. • The dB(C) value is normally 6-9 dB higher than the dB(A) value. Sound data - explanation The sound level is given in dB(A) for products in rooms and applies to rooms with 10 m² equivalent sound absorption area. Any exceptions are given in the product description. Measurement of air diffusers according to ISO 5135 and ISO 3471, which is intended for broad-band sound of a stable nature is performed according to the so-called "Comparison method", which means that the measured effective sound power level is compared with the sound pressure level for a calibrated sound source with a known sound power (method II and ASHRAE 36-72). The values given in the engineering graph apply to isothermal supply air. For air diffusers, the throw is given for mounting facing the ceiling. Some supply air diffusers can be mounted free hanging or suspended from the ceiling, in which case the throw is reduced by approximately 20%. "Free-hanging" means that the diffuser outlet is at least 400 mm from the ceiling. For calculating the width of the air stream, air velocities in the occupied zone or sound levels in rooms with other dimensions, please refer to our ProAir web calculation software available for download at www.swegon.com. Illustration of the spread direction: l 1 2 1 = Horizontal spread, cooling 2 = Vertical spread, heating Lw = Sound power level in the octave band in dB over 1 pW. (10 -12 W) Engineering graphs - explanation LA = Sound level in dB(A) according to normalised frequency weighting A. All sound levels are related to an equivalent absorption area of 10 m2 (acoustic absorption of 4 dB) General DL = Sound attenuation in the octave band (dB) KOK = Correction for calculation of LW value from the L A or LWtot values Unless stated otherwise, the engineering graph for each product provides the following information: • • • • • Sound level L A dB(A) or LWtot dB can be divided into octave bands using the correction factor KOK. This is given in table form for each product. Formula: Data for isothermal conditions Throw with an end velocity of 0,2 m/s Sound level L A dB(A) 10 m2 equivalent sound absorption Pressure drop pt, Pa Air flow q l/s and m3 /h Pressure drop LW = L A + KOK The sound data divided into octave bands is also given in table form. For products with a sound level reported in dB(A) the opening attenuation is included in the sound attenuation data. Calculation software Refer to Swegon's calculation software ProSelect for data regarding sound in the octave band and sound attenuation in the octave band. Airflow The airflow is given in l/s and m3 /h, and is listed in the engineering diagram for each product. In the engineering graph for air terminals the pressure drop is given as the total pressure drop (pt). The total pressure drop (pt) is the sum of the static pressure drop (ps) and the dynamic pressure (pd) over the air terminal. Supply air: pt = ps + pd For a supply air terminal the total pressure drop is the sum of two positive pressures and therefore has a larger numerical value than the static pressure drop. For extract air terminals the static pressure drop is negative and the total pressure drop is therefore a numerically smaller value than the static pressure drop. Extract air: pt = (-ps) + pd The dynamic pressure is calculated as follows: Throw length Testing method according to EN 12238. Pd The throw (l0,2) is the longest distance from the centre of a supply air diffuser to the isovel 0,2 m/s at isothermal = v2 2 r Pa where v is the inlet velocity in m/s r is the air density in kg/m3 20150217 Swegon reserves the right to alter specifications. 3 FALCON High Flow Airflow – Pressure drop – Sound level – Throw length FALCON HF 315 – Horizontal spread 100 FALCON HF 315 – Vertical spread pt Pa 100 50 40 30 50 40 30 40 dB (A) 30 20 35 25 35 25 20 5 4 3 2 100 200 400 300 500 400 500 1000 3 4 2000 5 l/s 2 100 1000 3 400 m /h 10 35 2000 30 40 l/s 1000 3 m /h 50 100 l0,2 m pt Pa 40 dB(A) 35 20 25 20 10 500 1000 50 40 30 40 dB (A) 30 500 400 FALCON HF 400 – Vertical spread 100 20 300 20 pt Pa 50 40 30 200 20 l0,2 m FALCON HF 400 – Horizontal spread 30 25 20 10 5 4 3 5 4 3 2 200 300 400 500 1000 4 1000 2000 5 3000 4000 10 l/s 2 200 2000 5000 m3/h 20 30 300 400 500 1000 1000 2000 20 l0,2 m FALCON HF 500 – Horizontal spread 30 40 3000 4000 50 l/s 2000 5000 m3/h 100 l0,2 m FALCON HF 500 – Vertical spread pt Pa pt Pa 100 100 40 dB(A) 50 40 30 30 40 dB(A) 50 40 30 35 25 20 35 30 25 20 20 10 20 10 5 4 3 300 400 500 2000 4 4 30 10 5 4 3 100 40 dB (A) 20 20 10 pt Pa 5 1000 3000 10 4000 2000 5000 l/s 3000 5 4 3 300 400 m3/h 20 Swegon reserves the right to alter specifications. 30 500 1000 2000 30 l0,2 m 20150217 40 3000 50 4000 2000 5000 100 l/s 3000 m3/h 200 l0,2 m FALCON High Flow Dimensions and weights FALCON HF Ø Size ØA ØB C D E ØF ØG ØH ØI ØJ Weight (kg) 315 591 314 44 110 340 514 631 671 711 561 10,5 400 703 399 44 122 350 616 743 783 823 673 13 500 853 499 40 135 460 765 893 933 973 823 18 *) *) Size 500 is delivered without a rubber seal ring Size of the opening = ØJ J A D C B E 137 mm 41 mm 64 mm F G H I Figure 2. FALCON HF, dimensions. Order key Product Circular ceiling air diffuser for supply air FALCON HF a -b -ccc Version: Manuel operated: 1 Motor operated: 2 Size: 315, 400, 500 Specification text SD XX Swegon's circular air diffuser type FALCON HF for ceiling mounting with the following functions: Figure 3. FALCON HF, spread modes. Solid outlet cone = horizontal spread mode. Dashed outlet cone = vertical spread mode. • Adjustable horizontal / vertical spread pattern • White powder paint sprayed and baked finish, RAL 9003/NCS S 0500-N • Factory mounted motor for 2 point regulation Size: 20150217 FALCON HFa-2-ccc xx items Swegon reserves the right to alter specifications. 5
© Copyright 2025 Paperzz