FALCON High Flow

FALCON High Flow
Circular ceiling air diffuser for supply air
QUICK FACTS
○○ Ceiling air diffuser for supply air in rooms with high
ceiling
○○ Manual operated change of spread direction as standard
○○ Motor operated change of spread direction as accessory
○○ Same total pressure drop for horizontal and vertical
spread
○○ Suitable for heating and cooling of rooms
○○ Standard whit RAL 9003
○○ Five alternative standard colours
AIR FLOW - SOUND LEVEL
FALCON High Flow
25 dB(A)
30 dB(A)
35 dB(A)
Size
l/s
m3/h
l/s
m3/h
l/s
m3/h
315
400
500
348
534
923
1253
1922
3323
402
618
1080
1447
2225
3888
464
716
1261
1670
2578
4540
Horizontal spread, cooling.
FALCON High Flow
Technical description
Design
• The FALCON HF consists of two parts: an outer cone
with rubber ring sealed-fitted spigot and an aerodynamically designed outlet cone. NOTE! Size 500 is
delivered without a rubber seal ring.
• As standard the outlet cone is manually operated
when changing the spread direction.
Materials and finish
• The entire air diffuser is made of sheet steel and its
interior and exterior surfaces are painted in our standard
white colour: RAL 9003/NCS S 0500-N.
• Alternative standard colours:
-RAL 9010, white
-RAL 9006, white aluminium
-RAL 7037, dusty grey
-RAL 9007, grey aluminium
-RAL 9005, jet black
• Non-painted and other colours upon request.
Accessories
Electrical motor
• 2 point regulation to change the spread to horizontal/
vertical direction.
Control unit for switching from cooling/heating
• VHC control unit switches the mode of motor controlled air diffusers, intended for both under-tempered and
over- tempered supply air. The controlling parameter
is the temperature difference between supply air and
extract air.
Installation
• Secure the inlet spigot to the connecting duct using
blind rivets.
Maintenance
• The air diffuser can be cleaned, if necessary, using
lukewarm water with dishwashing detergent added.
• Alternatively by vacuum cleaning using a brush nozzle.
Wiring Diagram
Belimo LM24A
alt. Belimo LM230A
Figure 1. Wiring diagram for FALCON HF, motor control with 2
point regulation. Switch is not included.
Motor features
Motor
LM24A
LM230A
2
Supply voltage
24 V AC 50/60 Hz
24 V DC
AC 100..240V 50/60
Hz
Power consumption
Running time
/ Torque
2 VA
150 s
/ 5 Nm
4 VA
150 s
/ 5 Nm
Swegon reserves the right to alter specifications.
20150217
FALCON High Flow
Sizing
air supply. A throw of l0,2 is provided for all Swegon's air
diffusers.
• The diagrams provide data for a FALCON HF placed in
a ceiling.
• The sound level is given in dB(A) for products in rooms
and applies to rooms with 10 m² equivalent sound
absorption area (normal acoustic absorption of 4 dB).
• Throw length l0,2 is measured at isothermal air supply.
• Recommended max. permissible temperature below
room temperature is 10K.
• The dB(C) value is normally 6-9 dB higher than the
dB(A) value.
Sound data - explanation
The sound level is given in dB(A) for products in rooms and
applies to rooms with 10 m² equivalent sound absorption
area. Any exceptions are given in the product description.
Measurement of air diffusers according to ISO 5135 and ISO
3471, which is intended for broad-band sound of a stable
nature is performed according to the so-called "Comparison method", which means that the measured effective
sound power level is compared with the sound pressure level
for a calibrated sound source with a known sound power
(method II and ASHRAE 36-72).
The values given in the engineering graph apply to
isothermal supply air.
For air diffusers, the throw is given for mounting facing
the ceiling. Some supply air diffusers can be mounted free
hanging or suspended from the ceiling, in which case the
throw is reduced by approximately 20%. "Free-hanging"
means that the diffuser outlet is at least 400 mm from
the ceiling.
For calculating the width of the air stream, air velocities
in the occupied zone or sound levels in rooms with other
dimensions, please refer to our ProAir web calculation
software available for download at www.swegon.com.
Illustration of the spread direction:
l
1
2
1 = Horizontal spread, cooling
2 = Vertical spread, heating
Lw
= Sound power level in the octave band in dB over 1
pW. (10 -12 W)
Engineering graphs - explanation
LA
= Sound level in dB(A) according to normalised
frequency weighting A. All sound levels are related
to an equivalent absorption area of 10 m2 (acoustic
absorption of 4 dB)
General
DL
= Sound attenuation in the octave band (dB)
KOK
= Correction for calculation of LW value from the L A or
LWtot values
Unless stated otherwise, the engineering graph for each
product provides the following information:
•
•
•
•
•
Sound level L A dB(A) or LWtot dB can be divided into octave
bands using the correction factor KOK. This is given in table
form for each product.
Formula:
Data for isothermal conditions
Throw with an end velocity of 0,2 m/s
Sound level L A dB(A) 10 m2 equivalent sound absorption
Pressure drop pt, Pa
Air flow q l/s and m3 /h
Pressure drop
LW = L A + KOK
The sound data divided into octave bands is also given in table form. For products with a sound level reported in dB(A)
the opening attenuation is included in the sound attenuation data.
Calculation software
Refer to Swegon's calculation software ProSelect for data
regarding sound in the octave band and sound attenuation in the octave band.
Airflow
The airflow is given in l/s and m3 /h, and is listed in the
engineering diagram for each product.
In the engineering graph for air terminals the pressure
drop is given as the total pressure drop (pt). The total
pressure drop (pt) is the sum of the static pressure drop
(ps) and the dynamic pressure (pd) over the air terminal.
Supply air:
pt = ps + pd
For a supply air terminal the total pressure drop is the
sum of two positive pressures and therefore has a larger
numerical value than the static pressure drop. For extract
air terminals the static pressure drop is negative and the
total pressure drop is therefore a numerically smaller value
than the static pressure drop.
Extract air:
pt = (-ps) + pd
The dynamic pressure is calculated as follows:
Throw length
Testing method according to EN 12238.
Pd
The throw (l0,2) is the longest distance from the centre of
a supply air diffuser to the isovel 0,2 m/s at isothermal
=
v2
2
r
Pa
where v is the inlet velocity in m/s
r is the air density in kg/m3
20150217
Swegon reserves the right to alter specifications.
3
FALCON High Flow
Airflow – Pressure drop – Sound level – Throw length
FALCON HF 315 – Horizontal spread
100
FALCON HF 315 – Vertical spread
pt Pa
100
50
40
30
50
40
30
40 dB (A)
30
20
35
25
35
25
20
5
4
3
2
100
200
400
300
500
400
500
1000
3
4
2000
5
l/s
2
100
1000
3
400
m /h
10
35
2000
30
40
l/s
1000
3
m /h
50
100
l0,2 m
pt Pa
40 dB(A)
35
20
25
20
10
500
1000
50
40
30
40 dB (A)
30
500
400
FALCON HF 400 – Vertical spread
100
20
300
20
pt Pa
50
40
30
200
20
l0,2 m
FALCON HF 400 – Horizontal spread
30
25
20
10
5
4
3
5
4
3
2
200
300
400
500
1000
4
1000
2000
5
3000
4000
10
l/s
2
200
2000
5000 m3/h
20
30
300
400
500
1000
1000
2000
20
l0,2 m
FALCON HF 500 – Horizontal spread
30
40
3000
4000
50
l/s
2000
5000 m3/h
100
l0,2 m
FALCON HF 500 – Vertical spread
pt Pa
pt Pa
100
100
40 dB(A)
50
40
30
30
40 dB(A)
50
40
30
35
25
20
35
30
25
20
20
10
20
10
5
4
3
300
400
500
2000
4
4
30
10
5
4
3
100
40 dB (A)
20
20
10
pt Pa
5
1000
3000
10
4000
2000
5000
l/s
3000
5
4
3
300
400
m3/h
20
Swegon reserves the right to alter specifications.
30
500
1000
2000
30
l0,2 m
20150217
40
3000
50
4000
2000
5000
100
l/s
3000
m3/h
200
l0,2 m
FALCON High Flow
Dimensions and weights
FALCON HF Ø
Size
ØA
ØB
C
D
E
ØF
ØG
ØH
ØI
ØJ
Weight (kg)
315
591
314
44
110
340
514
631
671
711
561
10,5
400
703
399
44
122
350
616
743
783
823
673
13
500
853
499
40
135
460
765
893
933
973
823
18
*)
*)
Size 500 is delivered without a rubber seal ring
Size of the opening = ØJ
J
A
D
C
B
E
137 mm
41 mm
64 mm
F
G
H
I
Figure 2. FALCON HF, dimensions.
Order key
Product
Circular ceiling air diffuser for
supply air
FALCON HF
a
-b
-ccc
Version:
Manuel operated: 1
Motor operated: 2
Size: 315, 400, 500
Specification text
SD XX
Swegon's circular air diffuser type FALCON HF for ceiling
mounting with the following functions:
Figure 3. FALCON HF, spread modes.
Solid outlet cone = horizontal spread mode.
Dashed outlet cone = vertical spread mode.
• Adjustable horizontal / vertical spread pattern
• White powder paint sprayed and baked finish, RAL
9003/NCS S 0500-N
• Factory mounted motor for 2 point regulation
Size:
20150217
FALCON HFa-2-ccc
xx items
Swegon reserves the right to alter specifications.
5