iQ-Therm 30 / 50 / 80

Page 1 of 2
Technical Data Sheet
Art. No. 0241, 0242, 0243
iQ-Therm 30 / 50 / 80
Capillary-active, rigid PUR foam panels for the construction of highly thermal insulating, diffusion-open,
interior insulation with capillary transport of moisture
For use indoors
Working
temperature
Panels/m²
Range of use
Remmers iQ-Therm combines
capillarity, thermal insulation and
regulation of humidity in one system. To realise these multifunctional requirements, holes are
made in regular intervals perpendicular to the surface in highly
thermal insulating, polyurethane
foam panels. These holes are filled
at the factory with a special, highly
capillary-active, mineral material.
The panels are attached to the
surface of the interior wall with iQFix and finished with a layer of
render, iQ-Top.
With a thickness of 1.0 cm iQ-Top
represents the sorption layer.
Property profile
Remmers iQ-Therm 30, 50 or 80
are made of highly thermal insulating, rigid PUR foam panels that
have holes filled with a mineral,
capillary conductive filling.
The rigid foam panels are used
exclusively in a system. The iQTherm system is building material
class B1 flammable according to
DIN 4102-1.
Store frost-free
Characteristic data of the product
Rigid PUR foam panels according to EN 13165
Dimensions:
- Length
- Width
- Thickness iQ-Therm 30
- Thickness iQ-Therm 50
- Thickness iQ-Therm 80
Dry density approx.
Thermal conductivity
Tensile strength perpendicular
to the panel plane approx.
Water vapour diffusion
W 80
W sat
Aw value
Building material class
System components
iQ-Fix
iQ-Therm L15
iQ-Therm K50
iQ-Top
iQ-Tex
iQ-Fill
iQ-Paint
1200 mm +/- 2 mm
600 mm +/- 2 mm
30 mm +/- 2 mm
50 mm +/- 2 mm
80 mm +/- 2 mm
45 kg/m³
0.031 W/mK
115 kPa
µ= approx. 27
0.0026 m³/ m³
0.98 m³/ m³
0.774 kg/(m² h0.5)
B2 flammable
according to DIN 4102-1
Notes
Before using, the panels must be
stored for 48 hours in the room to
be insulated at a temperature
above 5 °C.
Observe the Technical Data
Sheets for the components in the
system.
0241-0243 iQ-Therm 30-50-80_11.16
Remmers GmbH 49624 Löningen Tel 05432/83-0 Fax: 05432/3985
www.remmers.de
Page 2 of 2
Packaging, storage
Directions
Level highly uneven substrates
– close joints and even the
surface with Undercoat Render, Art. No. 0401.
Cement Remmers iQ-Therm
panels in place full surface using Remmers iQ-Fix, a hydraulic setting attachment mortar
Apply iQ-Fix evenly to the level
substrate and to the iQ-Therm
panels with a toothed trowel in
a buttering-floating procedure.
Then press the iQ-Therm panels into the fresh cement bed –
avoid cross joints.
The use of dowels is not necessary.
After iQ-Therm has been attached, the entire surface is
coated with a 1.0 cm thick
layer of render, iQ-Top.
Packaging:
30 mm, 50 mm and 80 mm panels
Dimensions
Width
Length
iQ-Therm
30
iQ-Therm
50
iQ-Therm
80
600 mm
1200 mm
30 mm
+/- 2mm
+/- 2mm
+/- 2 mm
600 mm
1200 mm
50 mm
+/- 2mm
+/- 2mm
+/- 2 mm
600 mm
1200 mm
80 mm
+/- 2mm
+/- 2mm
+/- 2 mm
Packaging unit
Panels per package / m²
14 panels ≙ 10,08 m²
8 panels ≙ 5,76 m²
5 panels ≙ 3,60 m²
Storage:
Frost-free
0751
Remmers GmbH
Bernhard-Remmers-Str. 13
D – 49624 Löningen
Safety, ecology, disposal
Further information on safety when
transporting, storing and handling as
well as disposal and ecology is
found in the latest Safety Data
Sheet.
Thickness
09-01
GBI F 021-3
0241 – 0242 – 0243
DIN EN 13165:2012
PU – EN 13165 – T2 – DS (70,90)3 - CS(10/Y)100 – TR 80
Thermal insulation material for buildings
Reaction to fire
Nominal value of resistance to
heat transmission
As “iQ Therm System“
on mineral substrates
building material class
flame-retardant (DIN
4102-B1)
Nominal value of thermal conductivity
Nominal thickness/thickness
tolerance
Compressive strength/stress
Tensile strength perpendicular
to the panel plane
Dimensional stability under defined temperature and moisture
conditions
Fire resistance class E (EN 13501-1)
Nominal thickness 30 mm = RD 0.938
Nominal thickness 50 mm = RD 1.563
Nominal thickness 80 mm = RD 2.500
Nominal value: λD = 0.032 W/m·K
30 - 80 mm / T2
CS(10/Y)100
TR80
DS(70,90)3
DS(-20,-)1
The statements above are compiled from our field of
production and according to the latest technological
developments and application techniques.
Since application and working are beyond our control, no
liability of the producer can be derived from the contents of
this information sheet. Any statements made beyond the
contents of this information must be confirmed in writing
by the producer.
In all cases, our general conditions of sale are valid.
With the publication of this Technical Information Sheet all
previous editions are no longer valid.
Remmers (UK) Limited Crawley
United Kingdom
Tel: +44 (0) 1293 594 010
Fax: +44 (0) 1293 594 037
www.remmers.co.uk
0241-0243 iQ-Therm 30-50-80_11.16
Remmers GmbH 49624 Löningen Tel 05432/83-0 Fax: 05432/3985
www.remmers.de