Two alarms indicator 1/8 DIN - 96 x 48 J1 line Q u i c k G u i d e • Ι STR-FJ1ENG02 Declaration of Conformity and Manual retrieval Description and dimensions J1 is panel mounting, Class II instrument. It has been designed with compliance to the European Directives. All information about the controller use can be found in the User Manual: MIU_J1_EN.pdf. The Declaration of Conformity and the manual of the controller can be downloaded (free of charge) from the web-site: www.ascontecnologic.com Once connected to the web-site, search: J1 then click on J1 from the result list. In the lower part of the product page (in any language) is present the download area with links to the documents available for the controller (in the available languages). Depth: 110 mm Electrical connections IN1 Input value (engineering units) J1 Menu access Min./Max. values display Alarm acknowledge Alarm status LEDs Selection/ value confirmation Thermocouple Panel cut out and mounting 1 Warning! Model Code Configuration Code The product code indicates the specific hardware configuration of the instrument, that can be modified by specialized engineers only. A 4 + 2 digits index code follows the model (letters from I... P). This code must be set to configure the controller. Using UP ( ) and DOWN ( ) keys insert the desired configuration code. When not configured the 1st part of the code is 9999. Line Model: J 1 Basic Accessories Configuration 2nd part 1st part Line J Power supply Input type and range I L TR Pt100 IEC751 -99.9…300.0°C -99.9…572.0°F 0 0 1 TR Pt100 IEC751 -200…600°C -328…1112°F 0 1 A TC L Fe-Const DIN43710 0…600°C 32…1112°F 0 2 A B C 0 - 0 9 0 0 / I L M 0 - O P 0 0 100...240Vac (-15...+10%) 3 TCJ Fe-Cu45% Ni IEC584 0…600°C 32…1112°F 0 3 24Vac (-25...+12%) or 24Vdc (-15....+25%) 5 TC T Cu-CuNi -200 …400°C -328…752°F 0 4 Outputs OP1 - OP2 B TC K Chromel-Alumel IEC584 0…1200°C 32…2192°F 0 5 None 0 TC S Pt10%Rh-Pt IEC584 0…1600°C 32…2912°F 0 6 Relay - Relay 7 TC R Pt13%Rh-Pt IEC584 0…1600°C 32…2912°F 0 7 Serial Communications C None 0 RS485 Modbus/Jbus SLAVE 5 TC B Pt30%Rh Pt6%Rh IEC584 0…1800°C 32…3272°F 0 8 TC N Nichrosil-Nisil IEC584 0…1200°C 32…2192°F 0 9 TC E Ni10%Cr-CuNi IEC584 0…600°C 32…1112°F 1 0 TC NI-NiMo18% 0…1100°C 32…2012°F 1 1 TC W3%Re-W25%Re 0…2000°C 32…3632°F 1 2 TC W5%Re-W26%Re 0…2000°C 32…3632°F 1 3 Dc input 0…50mV linear Engineering and units 1 4 Dc input 10…50mV linear Engineering and units 1 5 1 6 Custom input and range [1] Pt100 External shunt 2.5Ω mA - Whenever a failure or a malfunction of the device may cause dangerous situations for persons, things or animals, please remember that the plant must be equipped with additional devices which will guarantee safety. - We warrant that the products will be free from defects in material and workmanship for 18 months from the date of delivery. Products and components that are subject to wear due to conditions of use, service life and misuse are not covered by this warranty. viale Indipendenza 56, 27029 - Vigevano (PV) Tel.: +39 0381 698 71, Fax: +39 0381 698 730 internet site: www.ascontecnologic.com E-mail: [email protected] mV 2 Terminals Ø L 2 1 Display mode M Green 0 Red 1 Red when alarm 1 (AL1) active 2 O Alarm type and function Stripped wire L: 5.5 mm 0.21 in. Fork-shape AMP165004 Ø 5.5 mm - 0.21 in. Pin connector 1.4 mm 0.055 in. max. q P AL1 AL2 Non-active 0 Sensor break alarm 1 Active High Absolute Deviation Band 2 Active Low 3 Active High 4 Active Low 5 Active Out 6 Active In 7 Rate alarm (AL1 only) 8 - [1] For instance, other thermocouples types, custom linearisation etc. Indicator configuration chart Parameter list The present chart includes only the basic parameters For the list and the description of all the indicatorparameters see the User Manual. When the indicator is new and not configured shows the code Conf at power ON. In this case NO PASSWORD is needed to configure the instrument (see the grey box in the chart below). Enter the configuration code in accordance with the desired functional characteristics. The parameters pointed out with grey background are those necessary to configure the options and are NOT shown in the configuration chart. All the parameters are fully described and explained in the user manual of the controller. If the parameter Code has previously set to a value ≥5000, (for example 5033 in the chart) the indicator is locked in operator mode; insert the correct password to access both the parameter and the configuration menus. Operator mode 5033 pAss Password Entry Only if Code value ≥5000 1274. 8 Code Parameter Name 1st Configuration Value Default Alarm parameters Al.par Al. sp Configuration Al.1sp AL1 alarm threshold Al.1Op AL1 alarm output Al.1hy AL1 hysteresis Al.2Op AL2 alarm output Al.2sp AL2 alarm threshold Op.1a AL1 alarm action Al.2hy AL2 hysteresis Op.1a AL2 alarm action Al.ref Alarm internal reference value (engineering unit) Al.1lb AL1 Latching/ blocking Configuration code digits O - P Al.2lb AL2 Latching/ blocking Engineering units (see table 2) pAss Only if Code value <5000 (33 factory default) Must be equal to the value of the parameter Code [3] Configuration code digits I - L - M - N If linear scales are choosen, set also the following 5 parameters Number of decimals Low range High range IN1 square root Notes: [2] Cut off the square root of the input value enables the user to round to zero a result that is too low to be important. [3] A not configured indicator shows Conf at power ON: the configuration procedure is shown in the grey box. [4] The controller shows pass after conf: using the keys S and G insert the password to configure the controller. Table 1 Engineering Units Value C f none mU U mA A bar psI rh ph Description degree Celsius degree Fahrenheit none mV Volt mA Ampére Bar PSI Rh pH IN1 square root result cut-off [2] IN1 filter time constant IN1 input shift New password (33 factory default) Value Default Code Password 33 0000 AL.1SP AL1 alarm Threshold 0 Unit Engineering units NONE AL.1Hy AL1 Alarm Hysteresis 0 in.1dd IN1 decimal point O AL.2SP AL2 alarm Threshold 0 in.1Lo IN1 low range for engineering units O AL.2Hy AL2 Alarm Hysteresis 0 in.1Hi IN1 high range for engineering units 9999 AL.reF Alarm reference source (eng. units) 0 tFiL.1 IN1 filter time constant Password Entry [4] Parameter Name 9999 code Cut1 IN1 square root result cut-off Conf Code Con.2 2nd Configuration code Con.1 in.1Cn IN1 square root Alarm set User in.1Sh IN1 input shift AL.1OP AL1 alarm output OP1 AL.2OP AL2 alarm output OP2 OP.1a AL1 alarm action Direct Direct Prot Communications protocol JBUS OP.2A AL2 alarm action baud Baud rate 9600 AL.1lb AL1 alarm latching/blocking 0 1 AL.2lb AL2 alarm latching/blocking 0 Addr Indirizzo seriale dell’indicatore User
© Copyright 2026 Paperzz