US_L_07_Cond_038_049.qxd 01.02.2005 19:27 Uhr Seite 38 Conductivity Conductivity Conductivity Meters Meters Conductivity Conductivity is a parameter used to measure the ionic concentration and activity of a solution. The more salt, acid or alkali in a solution, the greater its conductivity. The unit of conductivity is S/m, often also S/cm. The scale for aqueous solutions begins with pure water at a conductivity of 0.05 µS/cm (77 °F / 25°C). Naturally occurring waters such as drinking water or surface water have a conductivity in the range 100 – 1000 µS/cm. At the upper end of the chart some acids and alcalines can be found. Conductivity of aqueous solutions µS/cm 0,1 mS/cm 1 10 100 1 10 100 1000 Feedwater for high-pressure boilers Fully deionized water (ion exchanger) Deionized water Drinking water Wastewater Surface water Brackish water, sea water Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water. Industrial process water Concentrated acids and bases Conductivity is measured by making a measurement of the electrical resistance. The simplest kind of measuring cell used consists of two similar electrodes. An alternating voltage applied to one of the electrodes causes the ions in the solution to migrate towards the electrodes. The more ions in the solution, the greater the current which flows between the electrodes. The instrument measures the current and uses Ohm's law to calculate first the conductance of the solution and then – by taken the cell data into account – the conductivity. 38 For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. Cond Cond 315i Cond 330i Cond 340i – ● ● – ● – ● – – ● ● ● ● ● ● ● ● ● ● ● ● ● – – ● – – – – – – ● ● – ● ● ● ❍ – AQA with documentation – R&D hidh precision – Control measurements – LIMS connection – Quality assurance – Training ● ● ● ● ● ● ❍ – ● – ● ● ● ● ❍ Service Field measurements – ● – – ● – – ● – ● ● ● ● ● – ● – ● ● – ● ● ❍ ● Depth measurements – – – ● – – – – External control/PC connection/ PC control – ●/●/– ●/●/● ●/●/– – – – ●/●/– Suitable for USP 27 ● ● ● ● ● ● ● ● ● ● – ● ● – – ● ● ● ● ● ● Measurement of ultrapure water ● ● ● ● ● ● ● ● Trace conductivity ● ● ● ● – – ● ● see page 40 40 41 42 for conductivity measurements with multi-parameter instruments see page 50 45 44 44 44 Laboratory measurements Salinity/TDS measurement LR325/001 TetraCon® DU/T TA 197 LF USP 27 – – ● ● – – Pharmaceutical water ❍ ❍ ● – – – ● – ❍ ● – – – ● – – – ● ● ❍ ● – – – – – ● – – ● – – – – ● – ● ● – – – – – – ❍ ❍ – – ● ❍ – ● – ❍ – ● – ● – – ❍ – ● – – ❍ – – – – – – – – – Application Range Sensors Chemical water Ground water Surface waters Depth measurements (barrages) Laboratory measurements Foods industry (juices) Swimming pools Pharmaceutics Cosmetics/Detergents TetraCon® 325 LR 325/01 ● – TetraCon® 325/S Specific resistance only SAL Semi-conductor industry – Paint/Varnish (soluble) ● ● Electroplating applicable instruments: all/except all/except all/except all/except all/except VARIO VARIO/ VARIO VARIO/ VARIO/ 315i 315i 315i Parameter pH Cond 197i – ● Routine measurement with documentation ORP Cond 740 – ● Routine measurement ISE Cond 730 ● Application Range Oxygen (D.O.) Cond 720 Profi- VARIO Handheld Meters Line Conductivity inoLab® Multiparameter – not recommended BOD/ Respiration ❍ conditionally applicable Photometers ● recommended by WTW Seite 39 Turbidity 19:27 Uhr Colony Counter 01.02.2005 Software/ Printers US_L_07_Cond_038_049.qxd Cond 197i For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 39 US_L_07_Cond_038_049.qxd 01.02.2005 19:28 Uhr Seite 40 Conductivity NEW Conductivity Laboratory Conductivity MetersMeters Conductivity is an important parameter that is often used for monitoring water quality. In the laboratory sector this parameter has also increased in importance since the introduction of USP 27 Guideline for pharmaceutical water. WTW inoLab® Cond laboratory instruments meet all the requirements for measurements according to this standard. inoLab® Cond 720 Simple and reliable Application specific displays Touch-sensitive keypad with pressure point and tactile response Battery or line power operation Routine laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. 68 °F or 77 °F (20 °C or 25 °C) can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell. inoLab® Cond 730 Compact and precise Simplified operator convenience GLP documentation via PC or optional built-in printer Meets all the requirements of USP 27 40 Standard laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. The datalogging capability and the real-time clock allows for all GLP functions. Data output can take place via the optional built-in printer on thermal paper accepted for use for official documents or via the built-in RS 232 digital interface via a PC or external printer. 68 °F or 77 °F (20 °C or 25 °C) can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell. IP 43 3 Year Warranty For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. Seite 41 NEW inoLab® Cond 740 Conductivity Meters inoLab® Cond 740 with Terminal or PC software: flexible and powerful Meets all the requirements of USP 27 High-performance laboratory conductivity meter with graphic display and digital recorder function, parallel display of temperature and automatic temperature compensation. A built-in datalogger and a real-time clock allows for all QA conforming functions. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. Parameter 19:28 Uhr pH 01.02.2005 TDS and salinity measurement External control with MultiLab® pilot via PC ISE 68 °F or 77 °F (20 °C or 25 °C) can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell. ORP US_L_07_Cond_038_049.qxd Oxygen (D.O.) A PC keyboard interface allows an external keyboard or a barcode reader to be connected. additional features Range/Resolution Conductivity Multiparameter Cond 720 and Cond 730 Cond 740 Temperature: Salinity: TDS: Resistivity: 0.0 µS/cm ... 500 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 19.99 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 1.999 µS/cm 23 … 211.82 °F (-5.0 ... +99.9 °C) 0.0 ... 70.0 0 ... 1999 mg/l 0.000 ... 1999 MΩcm 0.0 µS/cm ... 2000 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 20.00 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 2.000 µS/cm 23 … 221 °F (-5.0 ... +105.0 °C) 0.0 ... 70.0 0 ... 2000 mg/l 0.000 ... 2000 MΩcm Conductivity: Temperature: ± 0.5 % of value ± 0.1 K Conductivity: Accuracy (± 1 digit) Reference temperature 68 … 77 °F (20 °C or 25 °C) selectable Cell constants 0.475 cm-1, 0.1 cm-1 and 0.01 cm-1 fixed; freely selectable 0.25 ... 2.5 cm-1 and 0.09 ... 0.11 cm-1 Temperature compensation Automatic or switched off Temperature coefficient • Non-linear function for natural water to EN 27 888 • Linear compensation from 0.001 ... 2.999%/K • No compensation Calibration With 0.01 mol KCl 0.475 cm-1, 0.1 cm-1 and 0.01 cm-1 fixed; freely selectable 0.25 ... 2.5 cm-1 Colony Counter Model Ordering Information inoLab® Laboratory Conductivity Meter SETs – with wide-range power supply 100-240 VAC (50/60 Hz) included Order No. inoLab® 1C10-0111 Cond 720 Simple and reliable conductivity meter, including TetraCon® 325 and accessories inoLab® Cond 730 Compact precision conductivity meter, including TetraCon® 325, passive multifunction box and accessories 1C20-0111 inoLab® Cond 740P The intelligent conductivity measuring station with additional built-in printer, TetraCon® 325 and accessories 1C31-0111 Passive multifunction box (not included in Cond 720 Set) BOD/ Respiration Technical Data Photometers 3 Year Warranty IP 43 Turbidity • • • Built-in digital recorder Real-Time Graphic Display User Selectable Languages Multi-Level GLP Functions (password-protected operator levels) Limit input with acoustic alarm Meets all the requirements of USP 27 Free-of-charge software downloads for MultiLab® pilot or terminal Software/ Printers • • • • 109 810 For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 41 US_L_07_Cond_038_049.qxd 01.02.2005 19:28 Uhr Seite 42 Conductivity Conductivity Portable Conductivity Meters Meters ProfiLine Cond 197i The WTW conductivity meter of the ProfiLine Cond 197i series is both hoseproof (IP 66) and submersible (IP 67). Along with an 800 data file datalogger, a real time clock and recorder output, the ProfiLine Cond 197i conforms to all GLP requirements. They are equipped with a carrying/support handle and carrying strap as standard. New: Powerful NiMH rechargeable batteries. The Cond 197i is suitable for depth measurements down to 330 ft (100 m) in combination with the TA 197 LF depth armature. IP 66 IP 67 Highly precise, indestructible, waterproof Large, silicone keys for field use Large, easy to read display Measurement down to depths of 330 ft (100 m) 3 Year Warranty Conductivity depth armature TA 197 LF with built-in temperature sensor, up to 100 m cable with waterproof plug (IP 67), pressure-resistant steel armoring (material VA 1.4571) with screw-off protective hood, pressure-resistant to max. 10 bar, fits into small boreholes (2“ dia.). Technical Data Model ProfiLine Cond 197i Range/ Resolution LF: Temp.: Salinity: TDS: Accuracy (±1 digit) LF: Temp.: 0.0 µS/cm … 500 mS/cm in 5 measuring ranges or AutoRange, 0.00 … 19.99 µS/cm for K=0.1 cm-1, 0.000 … 1.999 µS/cm for K=0.01 cm-1 23 … 221 °F (-5.0 °C … +105.0 °C) 0.0 … 70.0 0 … 1999 mg/l ±0.5 % of value ±0.1 K Reference temp. 68 … 77 °F (20 °C or 25 °C), selectable Call constant Calibratable 0.450...0.500 and 0.800...1.200 cm-1, fixed: 0.01 cm-1 freely adjustable 0.25 … 2.5 cm-1 and 0.09 … 0.11 cm-1 Temperature comp. Automatic, can be switched off Temperature coefficient • Non-linear function for natural waters to EN 27 888 and ultrapure water function • Linear compensation from 0.01 ... 2.99 %/K • No compensation Ordering Information 42 Portable Conductivity Meter – with wide-range power supply 100-240 VAC (50/60 Hz) included Order No. ProfiLine Cond 197i 3C30-010 Robust, waterproof, submersible conductivity meter Depth armatures down to 330 ft (100 m) see brochure “Product Details” For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 19:28 Uhr Seite 43 Conductivity Handheld Conductivity Meters Meters Conductivity Meters Parameter 01.02.2005 pH US_L_07_Cond_038_049.qxd BOD/ Respiration Multiparameter 4-electrode principle allows a wide range of applications Oxygen (D.O.) Up to 1500 hours of continuous operation Conductivity Robust, shockproof, waterproof ISE ORP Cond 315i, Cond 330i, Cond 340i Photometers Cond 340i in field armoring FM 325 (optional) Software/ Printers Useable anywhere, WTW handheld instruments are robust, easy to operate and provide assured accurate readings. From the monitoring of on-line process systems to field studies, WTW’s handheld Conductivity meters meet all your measurement needs. Turbidity Complete as SET Colony Counter Cond 330i in protective armoring SM 325 (optional) IP 66 IP 67 3 Year Warranty For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 43 US_L_07_Cond_038_049.qxd 01.02.2005 19:28 Uhr Seite 44 Conductivity Conductivity Handheld Conductivity Meters Meters WTW handheld conductivity meters are available in three versions: Cond 315i The simple conductivity meter for meeting higher demands. With only 5 keys for error-free measurement with parallel temperature measurement, automatic temperature compensation, 4-electrode measuring technology. Cond 330i Robust and waterproof handheld conductivity meter for battery operation; with parallel temperature display, integrated datalogger, GLP supporting functions, automatic and manual temperature compensation with linear temperature function and non-linear function for ultrapure water and natural waters according to EN 27 888. The temperature compensation can be switched off; either 68 °F or 77 °F (20 °C or 25 °C) can be selected as the reference temperature. Cond 340i As Cond 330i, but with additional analog and digital RS 232 output and an optional power supply is available. Cond 315i Technical Data Model Cond 315i Range/ Resolution LF: Temp.: Salinity: TDS: Resistivity: Accuracy (± 1 digit) LF: Temp.: Cond 330i and Cond 340i 0.0 µS/cm … 500 mS/cm in 5 measuring ranges or AutoRange 0.00 µS/cm ... 19.99 µS/cm (for K=0.1 cm-1) 0.000 µS/cm ... 1.999 µS/cm (for K=0.01 cm-1) 23 … 221 °F (-5.0 °C … +105.0 °C) 0.0 … 70.0 – 0 … 1999 mg/l 0.000 ... 1999 MΩcm ±0.5 % of value ±0.1 K Reference temp. Tref 68 … 77 °F (20 °C or 25 °C), selectable Cell constant Fixed 0.475 cm-1, 0.1 cm-1 Temperature comp. Automatic, can be switched off Temperature coefficient • Non-linear function for natural waters (nLF) to EN 27 888 and ultrapure water function – • Linear compensation from 0.01 ... 2.99 %/K • No compensation 0.475 cm-1, 0.1 cm-1 and 0.01 cm-1 fixed and 0.25 ... 2.5 cm-1 and 0.09 ... 0.11 cm-1 adjustable Ordering Information Handheld Conductivity Meter SETs Order No. Cond 315i Robust and waterproof battery-operated handheld conductivity meter, including TetraCon® 325, professional case and accessories 2C10-0011 Cond 330i Robust and waterproof battery-operated handheld conductivity meter with datalogger, including TetraCon® 325, professional case and accessories 2C20-0011 Cond 340i Robust and waterproof battery-operated handheld conductivity meter with datalogger and serial interface, including TetraCon® 325, professional case and accessories 2C30-0011 Universal wide-range power supply 100 V - 240 V, 50 - 60 Hz; for 340i series 44 902 867 Other measuring cells in SET see brochure “Product Details” For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 10:09 Uhr Seite 45 Conductivity VARIO Cond Meters Conductivity Meters Parameter 02.02.2005 pH US_L_07_Cond_038_049.qxd NEW ORP Simple measurement at a your fingertips – now also available for conductivity measurement! ISE Touch screen Large operating range Oxygen (D.O.) Plug-in cells – no cables Model VARIO Cond Range [µS/cm] 0.00 … 19.99 (when and Resolution using module LR01 V) 0.0 … 199.9 0 … 1999 [mS/cm] 0.00 … 19.99 0.0 … 199.9 Resistivity [k*cm] 0.000 … 1.999 0.00 … 19.99 0.0 … 199.9 0 … 1999 Resistivity [M*cm] 0.00 … 19.99 0.0 … 199.9 0 … 1999 SAL 0.0 … 70.0 according IOT TDS [mg/l] 0 … 1999 T [°F/°C] 41…221/5.0…+105.0 Multiparameter BOD/ Respiration Increased precision through the omission of cable connectors – the VARIO Cond is an appropriate solution for servicing and maintaining water treatment equipment. No matter whether using it for pure water measurement in semi-conductor industry or in cell culture laboratories, the pure water conductivity cell with flow-through vessel always allows a rapid and easy control measurement. Photometers Technical Data The globally renowned measurement cell TetraCon® 325 was specially shortened and modified for the VARIO Cond. With extra ultrapure water cell and flow vessel the Vario Cond is uniquely suited for ultrapure water analysis. Turbidity VARIO Cond has a lot to offer – at an excellent price. This economical designed meter is ideal for use in process control monitoring or anywhere a small, accurate meter is needed. The VARIO is small, light, handy, waterproof and has a robust firm-grip rubber armoring. Miniature precision Long-lasting power. VARIO Cond offers up to 500 hours of continuous operation – with just one standard battery. The low power technology shuts down the device after 10 minutes in standby. Changing the battery is easy and quick. Colony Counter VARIO Cond Conductivity 3 Years Warranty Ordering Information VARIO Cond Order No. VARIO Cond Set VARIO Cond in the mobile case set, incl. 4-electrode cell and KCI solution 0.01 mol/l 2X00-001A VARIO Cond Set VARIO Cond in the mobile case set, incl. ultra pure water cell and flow-through vessel 2X00-001B Software/ Printers IP 65 Other accessories see brochure “Product Details” For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 45 US_L_07_Cond_038_049.qxd 01.02.2005 19:29 Uhr Seite 46 Conductivity Conductivity Conductivity Cells Meters TetraCon® For more than 50 years WTW has been one of the leading manufacturers worldwide of precision conductivity meters and cells. The TetraCon® 4-electrode system is the result of our commitment to quality and sets a new standard for professional conductivity measurements. In comparison with conventional measuring cells with 2 electrodes, the TetraCon® conductivity cell offers numerous technical advantages: • • • • • • • • • • Highest degree of precision and linearity by optimized cell geometry Extremely large measuring range with just one cell Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes With built-in temperature sensor as standard Smallest immersion depth possible No measuring errors even with very dirty electrode – contact resistance on the electrode surface is automatically compensated No measuring errors from cable influences No measuring errors from primary or secondary polarization effects No measuring errors due to contact with side walls or base of measuring vessels Robust, unbreakable epoxy body ● ● ● ● ● ● ● 5 5 5 5 5 5 5 5 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 4 4 4 4 ● ● 5 5 ● ● ● ● Cond 197i LF 597 2 2 2 ● ● ● ● ● ● 5 5 5 5 5 5 5 5 ● ● ● ● ● ● ● ● ● ● ● 2 2 ● ● ● ● ● ● ● 4 4 LF 197 2 Multi 350i ● MultiLine® P3 pH/LF, pH/Cond 340i ● ● ● ● MultiLine® P4, Multi 340i, Multi 197i 2 MultiLab® P4/P5 inoLab® Cond, pH/Cond, Multi 2 MultiLab® 540 Cond 330i/340i 2 LF 3000 LF 330/340A 2 LF 539 LF 320/323/325 2 LF 538 LF 318 2 LF 537 LF 315 Cond 315i Measuring cell LTA 1 LTA 10 LR 01/T KLE 1/T KLE 315 TetraCon® 96 TetraCon® 96-1,5 TetraCon® 325 TA 197 LF TetraCon® 325/Pt TetraCon® DU/T TetraCon® DU/TH LR 325/01 LR 325/001 TetraCon® 325/S ConOx TetraCon® V LR01 V VARIO Cond Selection Guide 5 5 ● ● ● 4 4 Adapter (possible conversion with cell constants) is required: 46 2 Adapter cable K/LTA together with temperature sensor TFK 325 or TFK 150 4 Connection cable KKDU 5 Connection cable KKDU 325 For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 01.02.2005 19:29 Uhr Seite 47 301 961 40/120 mm 30/120 mm 301 992 V4A steel – V4A steel 4.72 in (120 mm) K = 0.1 cm-1 0.47 in (12 mm) 4.9 ft (1.5 m) 0.001 µS/cm ... 200 µS/cm 32 … 212 °F (0 ... 100 °C) 17 ml (without sensor) 301 962 V4A steel V4A steel V4A steel 4.72 in (120 mm) K = 0.01 cm-1 0.79 in (20 mm) 4.9 ft (1.5 m) 0.0001 µS/cm ... 30 µS/cm 32 … 212 °F (0 ... 100 °C) ca. 10 ml (without sensor) 40 mm 40/120 mm Conductivity flow-thru cell TetraCon® DU/T 301 252** Graphite – Epoxy 6.10 in (155 mm) K = 0.778 cm-1 – 3.3 ft (1 m) (only with KKDU 325) 1 µS/cm ... 2 S/cm* 32 … 140 °F (0 ... 60 °C) 7 ml Turbidity 301 602 Graphite – Epoxy 4.72 in (120 mm) K = 0.491 cm-1 0.60 in (15,3 mm) 4.9 ft (1.5 m) 1 µS/cm ... 2 S/cm* 32 … 212 °F (0 ... 100 °C) – Trace conductivity cell LR01 V LR 325/001 Colony Counter 301 960 301 990 Order No. Graphite Electrode material – Flow-thru vessel Epoxy Shaft material 4.72 in (120 mm) Shaft length K = 0.475 cm-1 Cell constant 0.60 in (15,3 mm) Diameter 4.9 ft (1.5 m) Cable length 1 µS/cm ... 2 S/cm* Measuring range 32 … 212 °F (0 ... 100 °C) Temperature range – Filling volume Min./max. 36/120 mm 40 mm immersion depth Ultrapure water conductivity cell LR 325/01 – * Measuring range depends on particular instrument, ** Adapter cable KKDU 325 (order no. 301 963), length 3.3 ft (1 m), is necessary for the connection For additional special measuring cells or other cable lengths see brochure “Product Details” For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. Software/ Printers Standard Special conductivity cell conductivity cell ® ® TetraCon 325 TetraCon V TetraCon® 325/S Photometers BOD/ Respiration Multiparameter Conductivity Oxygen (D.O.) ISE ORP pH Conductivity Cells Parameter US_L_07_Cond_038_049.qxd 47 US_L_07_Cond_038_049.qxd 01.02.2005 19:29 Uhr Seite 48 Conductivity Conductivity USP 27 and accessories Meters Calibration and testing agents Kit for measuring conductivity according to USP 27 This kit contains LR 325/01 Ultrapure water cell, D01/T Flow-thru vessel made of glass (USP-KIT 1) or stainless steel (USP-KIT 2), NIST traceable 5 µS standard with accuracy ±2 % and 6R/SET/LabTesting set Calibration standard 100 µS/cm Shelf life 2 years, NIST traceable with accuracy ±3 % NEW Calibration standard 5 µS/cm Shelf life 1 year, NIST traceable with accuracy ±2 % Ordering-Information Kit for measuring the conductivity according to USP 27 Order no. USP Kit 1 Kit for measuring conductivity according to USP 27, consisting of LR 325/01 Ultrapure water cell, D01/T Glass flow-thru vessel, NIST traceable 5 µS standard with accuracy ±2% and 6R/SET/LabTesting set 300 569 USP Kit 2 As USP Kit 1, but flow-thru vessel made of stainless steel instead of D01/T 300 568 KS 100µS Calibration standard 100 µS/cm, shelf life 2 years, NIST traceable with accuracy ±3% (300 ml) 300 578 KS 5µS Calibration standard 5 µS/cm, shelf life 1 year, NIST traceable with accuracy ±2% (300 ml) 300 580 EP/SET Calibration and platinization set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l, 30 ml platinizing solution, 1 calibration vessel), only for platinized cells 300 570 E/SET Calibration set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l) 300 572 Calibration agents 48 For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 01.02.2005 19:29 Uhr Seite 49 Multiparameter Conductivity Oxygen (D.O.) ISE Conductivity measuring kit according to USP 27, with stainless steel flow-thru vessel for pharmaceutical water. ORP pH USP 27 and accessories Parameter US_L_07_Cond_038_049.qxd Photometers BOD/ Respiration Flow-thru vessels Ordering Information D 530 Order no. Flow-thru vessel of transparent PVC, suitable for conductivity cells and temperature sensors, I.D. 44 mm, V*=97 ml 108 060 Flow-thru vessel of transparent PVC, I.D. 18 mm, V*=13 ml 203 730 Turbidity for LTA 1, LTA, LTA 01 and TFK 530 D 201 Colony Counter for TetraCon® 325 for TetraCon® 96, LTA 100 and KLE 1 Flow-thru vessel, glass I.D. 24 mm, V*=36 ml 302 730 Flow-thru vessel, glass I.D. 18 mm, V*=17 ml 302 750 Software/ Printers D 1/T for LR 01/T and LTA 01 D 01/T V*: filling volume without sensor For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. 49
© Copyright 2026 Paperzz