Equipment And Duct Liner/Wrap VOC ODP GWP zero zero low THE DURABLE AND CLEAN SOLUTION Armaflex® EDL – Foil-faced and self adhesive sheeting for insulation of equipment cabinets, ducting, storage tanks and pipe work. Product Description Armaflex EDL is a foil-faced elastomeric thermal insulation, supplied with a high performance self-adhesive backing. It is constructed from Armacell’s proven FR/Armaflex insulation material. Armaflex EDL is suitable for insulation of equipment cabinets, storage tanks, and air-conditioning ducts. Its superior-grip Pressure Sensitive Adhesive system makes it applicable in non-pinned field applications. It is also highly suited for raised-floor or under-floor air-conditioning systems. Benefits flexible and fibre free self-adhesive • excellent fire and weathering resistance • washable surface to support hygiene maintenance • non-wicking to reduce water presence in system and insulation • high flexibility for ease of fitting • self adhesive for fast and cost-effective application • fibre-free to prevent potential air-quality problems • closed-cell insulation to provide a continuous barrier to water vapour durable and smooth surface condensation control • low thermal conductivity for effective energy saving and CO2 reduction • genuine FR/Armaflex performance Air Conditioning and Ventilation refrigeration Technical Properties Short description Temperature range (Temperature limits) Max. surface temperature Values remarks +85°C For all applications outside this range, please contact our technical department. Min. surface temperature -40°C Water Vapour Permeability u>4,500 Tested according to ASTM E96 At 0°C At 25°C 0.036 W/(m.K) 0.038 W/(m.K) Tested according to ASTM C518 fire performance Ignitability Index.................. 0 Spread of Flame Index....... 0 Heat Evolved Index.............0 Smoke Developed Index.....0-1 Low Potential Smoke and Toxicity Hazard R = 0.43 Tested according to BS 6853. 1999 Clause B.4.2 Weathering and UV resistance Excellent Tested according to SAE J1885-1992 Size range Available in both sheets and continuous rolls 6mm, 9mm, 13mm, 19mm and 25mm thickness Sheets: 1.0m x 1.5m Roll width: 1.0m Temperature conductivity (λ) K-value Tested according to AS/NZS 1530.3 1999 Durability and resistance Outdoor applications - Armaflex EDL does not require painting Self-adhesive foil-faced sheet (1m x 1.5m) Self-adhesive foil-faced Thickness Product code Quantity Per Carton mm Inches Sheets Square metres 13 ½ 9E130001 15 22.5 19 ¾ 9E190001 10 15 25 1 9E250001 8 12 Self-adhesive foil-faced roll (1m width) Self-adhesive foil-faced Thickness Product code Length Per Carton mm Inches 6 ¼ 9E0600CS metres 15 9 3 8 9E0900CS 10 13 ½ 9E1300CS 8 19 ¾ 9E1900CS 6 25 1 9E2500CS 4 For applications that do not require a foil face, FR/Armaflex is availble with a self-adhesive backing, as listed below: Self-adhesive sheet (1m x 1.5m) Self-adhesive Thickness Product code Quantity Per Carton mm Inches Sheets Square metres 6 ¼ 9U060001 30 45 9 3 8 9U090001 20 30 13 ½ 9U130001 15 22.5 19 ¾ 9U190001 10 15 25 1 9U250001 8 12 Self-adhesive roll (1m width) Self-adhesive foil-faced Thickness Product code Length Per Carton mm Inches metres 13 ½ 9U1300CS 8 19 ¾ 9U1900CS 6 25 1 9U2500CS 4 Condensation Control Armaflex insulation provides excellent control of condensation. The thickness required will depend on the ambient air temperature, the relative humidity in the environment, and the temperature of the surface to be insulated. The level of airflow around any insulation will also affect its control of condensation. The surface characteristics of insulation material will affect its performance. Insulation that is covered with a shiny metal surface needs to be used in greater thickness than insulation with a black or non-reflective surface. Insulation with a shiny surface will reflect radiant heat, causing the surface to become cooler. To prevent the dew point occurring on the material’s surface (this is the point where condensation occurs) any metal-covered insulation must be used in greater thickness than insulation with a black non-reflective surface. The foil-facing on Armaflex EDL provides many benefits; the surface is highly resistant to fire, it is easily cleaned to provide hygienic and aesthetic advantages, and the foil provides an additional vapour barrier. In selecting the material’s thickness the effect of foil should be recognised, and the material applied in greater thickness than standard Armaflex. If you have any questions about your particular application, and the thickness of material required, please contact Armacell for Technical Service and recommendations. General Instructions • Armaflex EDL is highly flexible and can easily be wrapped around a duct, cabinet, vessel or large-diameter pipe work. • For very thick material (25mm), and for internal lining of small areas, it can easily be cut and fitted as small sheets. • The backing material is a pressure-sensitive adhesive, and requires the application of pressure across all areas to complete the bonding. Care should be taken to align the material, as it cannot be removed after the adhesive bonds and cures. Installation Tips 1 2 The temperature of the air and of the insulation should be between 10°C and 35°C at the time of installation. 5 3 Surface to be covered should be cleaned of all loose material, dust, grease and oil. Use a commercial degreaser and solvent wipe. 6 Square off sheet along an edge or corner. Press the sheet to the surface taking care not to trap any air. Cut with sharp knife. 4 Peel back enough release liner to start. 7 Reach behind the Armaflex sheet and peel liner back while pressing the sheet to the surface. Remove the entire liner piece. Press firmly. Butt joints require the use of compression to prevent the possible opening of seams. All joins in Armaflex EDL should be sealed with a high-grade aluminium foil. When using non-foil faced sheeting, ensure all exposed edges and joins are sealed with Armaflex 520 adhesive. Note:For further information consult the Armaflex Installation Manual Armaflex Around Ducting 1 For cladding of ducts, insulate the base first, then the sides, and finish with the top. This ensures a cleaner appearance and eliminates seems at the top, where moisture can drop down. 2 3 Roll a cylindrical object across the material repeatedly to apply solid and even pressure across all the adhesive system. The top should cover the side edges, leaving no exposed seems on top. Use a brush to force Armaflex adhesive between all joins to complete the vapor seal. Armacell Australia PTY LTD 13-17 Nathan Road, Dandenong, Victoria, 3175 T +613 8710 5999 F+613 8710 5900 www.armaflex.com.au [email protected] 4 Standing ribs can be insulated with strips of sheet Armaflex that are built-up around the area. Alternatively ribs can be insulated with Armaflex pipe-insulation that is cut in half and mitred at the edges. May 2007
© Copyright 2026 Paperzz