Armaflex EDL

Equipment And Duct Liner/Wrap
VOC
ODP
GWP
zero zero low
THE DURABLE AND CLEAN SOLUTION
Armaflex® EDL – Foil-faced and self adhesive sheeting for insulation of
equipment cabinets, ducting, storage tanks and pipe work.
Product Description
Armaflex EDL is a foil-faced elastomeric thermal insulation, supplied with a high performance self-adhesive backing. It is
constructed from Armacell’s proven FR/Armaflex insulation material. Armaflex EDL is suitable for insulation of equipment
cabinets, storage tanks, and air-conditioning ducts. Its superior-grip Pressure Sensitive Adhesive system makes it
applicable in non-pinned field applications. It is also highly suited for raised-floor or under-floor air-conditioning systems.
Benefits
flexible and fibre free
self-adhesive
• excellent fire and weathering resistance
• washable surface to support hygiene
maintenance
• non-wicking to reduce water presence in
system and insulation
• high flexibility for ease of fitting
• self adhesive for fast and cost-effective
application
• fibre-free to prevent potential air-quality
problems
• closed-cell insulation to provide a continuous
barrier to water vapour
durable and smooth
surface
condensation control
• low thermal conductivity for effective energy
saving and CO2 reduction
• genuine FR/Armaflex performance
Air Conditioning and Ventilation
refrigeration
Technical Properties
Short description
Temperature range
(Temperature limits)
Max. surface temperature
Values
remarks
+85°C
For all applications outside this range, please
contact our technical department.
Min. surface temperature
-40°C
Water Vapour Permeability
u>4,500
Tested according to ASTM E96
At 0°C
At 25°C
0.036 W/(m.K)
0.038 W/(m.K)
Tested according to ASTM C518
fire performance
Ignitability Index.................. 0
Spread of Flame Index....... 0
Heat Evolved Index.............0
Smoke Developed Index.....0-1
Low Potential Smoke and Toxicity Hazard R = 0.43
Tested according to BS 6853. 1999 Clause B.4.2
Weathering and UV resistance
Excellent
Tested according to SAE J1885-1992
Size range
Available in both sheets and continuous rolls
6mm, 9mm, 13mm, 19mm and 25mm thickness
Sheets: 1.0m x 1.5m
Roll width: 1.0m
Temperature conductivity (λ) K-value
Tested according to AS/NZS 1530.3 1999
Durability and resistance
Outdoor applications - Armaflex EDL does not require painting
Self-adhesive foil-faced sheet (1m x 1.5m)
Self-adhesive foil-faced
Thickness
Product code
Quantity Per Carton
mm
Inches
Sheets
Square metres
13
½
9E130001
15
22.5
19
¾
9E190001
10
15
25
1
9E250001
8
12
Self-adhesive foil-faced roll (1m width)
Self-adhesive foil-faced
Thickness
Product code
Length Per Carton
mm
Inches
6
¼
9E0600CS
metres
15
9
3
8
9E0900CS
10
13
½
9E1300CS
8
19
¾
9E1900CS
6
25
1
9E2500CS
4
For applications that do not require a foil face, FR/Armaflex is availble with a self-adhesive backing, as listed below:
Self-adhesive sheet (1m x 1.5m)
Self-adhesive
Thickness
Product code
Quantity Per Carton
mm
Inches
Sheets
Square metres
6
¼
9U060001
30
45
9
3
8
9U090001
20
30
13
½
9U130001
15
22.5
19
¾
9U190001
10
15
25
1
9U250001
8
12
Self-adhesive roll (1m width)
Self-adhesive foil-faced
Thickness
Product code
Length Per Carton
mm
Inches
metres
13
½
9U1300CS
8
19
¾
9U1900CS
6
25
1
9U2500CS
4
Condensation Control
Armaflex insulation provides excellent control of condensation. The thickness required will depend on the ambient air temperature, the
relative humidity in the environment, and the temperature of the surface to be insulated. The level of airflow around any insulation will
also affect its control of condensation.
The surface characteristics of insulation material will affect its performance. Insulation that is covered with a shiny metal surface
needs to be used in greater thickness than insulation with a black or non-reflective surface. Insulation with a shiny surface will reflect
radiant heat, causing the surface to become cooler. To prevent the dew point occurring on the material’s surface (this is the point where
condensation occurs) any metal-covered insulation must be used in greater thickness than insulation with a black non-reflective surface.
The foil-facing on Armaflex EDL provides many benefits; the surface is highly resistant to fire, it is easily cleaned to provide hygienic and
aesthetic advantages, and the foil provides an additional vapour barrier. In selecting the material’s thickness the effect of foil should be
recognised, and the material applied in greater thickness than standard Armaflex.
If you have any questions about your particular application, and the thickness of material required, please contact Armacell for Technical
Service and recommendations.
General Instructions
• Armaflex EDL is highly flexible and can easily be wrapped around a duct, cabinet, vessel or large-diameter pipe work.
• For very thick material (25mm), and for internal lining of small areas, it can easily be cut and fitted as small sheets.
• The backing material is a pressure-sensitive adhesive, and requires the application of pressure across all areas to
complete the bonding. Care should be taken to align the material, as it cannot be removed after the adhesive bonds
and cures.
Installation Tips
1
2
The temperature of the air and of
the insulation should be between
10°C and 35°C at the time of
installation.
5
3
Surface to be covered should
be cleaned of all loose material,
dust, grease and oil. Use a
commercial degreaser and
solvent wipe.
6
Square off sheet along an edge
or corner. Press the sheet to the
surface taking care not to trap
any air.
Cut with sharp knife.
4
Peel back enough release liner
to start.
7
Reach behind the Armaflex
sheet and peel liner back while
pressing the sheet to the surface.
Remove the entire liner piece.
Press firmly. Butt joints require
the use of compression to
prevent the possible opening of
seams.
All joins in Armaflex EDL should
be sealed with a high-grade
aluminium foil. When using
non-foil faced sheeting, ensure
all exposed edges and joins
are sealed with Armaflex 520
adhesive.
Note:For further information consult the Armaflex Installation Manual
Armaflex Around Ducting
1
For cladding of ducts, insulate
the base first, then the sides,
and finish with the top. This
ensures a cleaner appearance
and eliminates seems at the top,
where moisture can drop down.
2
3
Roll a cylindrical object across
the material repeatedly to apply
solid and even pressure across
all the adhesive system.
The top should cover the side
edges, leaving no exposed
seems on top. Use a brush
to force Armaflex adhesive
between all joins to complete the
vapor seal.
Armacell Australia PTY LTD
13-17 Nathan Road, Dandenong, Victoria, 3175
T +613 8710 5999 F+613 8710 5900
www.armaflex.com.au [email protected]
4
Standing ribs can be insulated
with strips of sheet Armaflex that
are built-up around the area.
Alternatively ribs can be insulated
with Armaflex pipe-insulation that
is cut in half and mitred at the
edges.
May 2007