CFL-LV-F1 CIRCULAR FILM LINED LOW VELOCITY SILENCER (<1500 FPM) HOW TO SPECIFY: EXAMPLE CERTIFIED PERFORMANCE DATA 24 X CFL-LV-F1 X 72 Silencer Duct Connection Model Size Insertion Loss (IL) + : “forward flow” where noise & airflow move in same direction (e.g. supply side) - : “reverse flow” where noise & airflow move in opposite directions (e.g. return side) DC (in.) SL (in.) (ft. per min.) FACE VEL. 12 24 0 24 48 36 72 48 96 60 120 - 1000 + 1000 DC (in.) SL (in.) (ft. per min.) 6 12 36 0 24 72 36 108 48 144 60 180 9 14 20 30 44 49 20 6 9 12 19 27 42 49 20 10 19 35 46 40 13 9 - 1000 6 10 + 1000 6 10 0 6 13 19 18 19 24 24 29 35 14 23 30 + 1000 9 14 21 28 14 - 1000 10 18 + 1000 10 0 10 47 49 40 20 13 45 40 13 38 27 10 37 39 34 37 27 27 10 10 32 35 34 21 18 26 31 32 32 21 9 20 27 32 32 29 19 9 11 20 + 1000 11 20 11 43 27 18 - 1000 0 22 37 34 9 9 29 23 - 1000 0 DC - Duct Connection Size (inches) SL - Silencer Length (inches) OCTAVE BAND - Hz/D.I.L. (dB) 63 125 250 500 1000 2000 4000 8000 6 27 32 28 33 27 32 34 34 30 33 21 30 19 28 19 9 9 9 9 Silencer Length FACE VEL. - 1000 + 1000 OCTAVE BAND - Hz/D.I.L. (dB) 63 125 250 500 1000 2000 4000 8000 7 13 20 30 44 60 60 30 7 13 19 28 41 60 60 30 9 16 28 35 48 59 55 7 - 1000 9 + 1000 0 13 16 29 9 16 11 21 - 1000 11 + 1000 0 0 - 1000 58 55 33 41 48 55 41 32 16 27 40 0 16 + 1000 46 42 40 49 46 60 56 54 DUCT SILENCER SILENCER CONNECT. OUTER LENGTH WEIGHT SIZE (in.) DIA. (in.) (in.) (lbs) 12 12 24 24 36 36 48 48 28 28 40 40 52 52 64 64 60 76 60 76 24 36 48 72 72 108 96 144 126 164 363 487 726 995 1233 1689 180 2599 120 1890 0.02 0.04 0.02 0.03 0.02 0.03 0.02 0.03 0.02 0.03 1000 1500 0.08 0.19 0.09 0.15 0.08 0.13 0.09 0.12 0.08 0.10 0.10 0.20 0.33 0.19 0.29 0.20 0.27 0.19 0.23 0.23 2000 0.36 0.59 0.33 0.51 0.36 0.48 0.33 0.42 0.33 0.40 LENGTH FACE VELOCITY (inches) (feet per minute) ALL - 1500 - 1000 + 1000 + 1500 50 33 27 39 42 44 48 33 29 42 44 46 43 29 16 29 16 29 2500 0.57 0.92 0.52 0.80 0.57 0.74 0.52 0.65 0.52 0.63 GN correction chart at right must be used to correct GN to other face areas. OCTAVE BAND - Hz/GENERATED NOISE (dB re 10 -12 watts) 63 125 250 500 1000 2000 4000 62 57 56 61 54 49 48 53 FACE AREA (sq.ft.) Questions? 1-800-565-8401 dB We reserve the right to improve our designs and data at any time without notice. 50 45 45 50 1.5 -3 48 43 42 47 3 0 5.155 46 41 38 43 6 +3 47 42 39 44 12 +6 44 39 37 42 24 41 48 43 41 42 45 43 3000 0.82 1.33 0.74 1.15 0.82 1.07 0.74 0.94 0.74 0.90 Pressure drops are reported in accordance with ASTM E477 methods and are based upon IDEAL flow conditions (5 diameters of straight duct on silencer inlet and 10 on outlet). Less than ideal conditions will result in an increase in pressure drop due to System Effects. See Silencer System Effects Data on page 4.19. Generated Noise (GN) @ 3 sq.ft. face area 41 43 46 49 48 44 44 42 FACE VELOCITY (feet per minute) / Pressure Drop (in.w.g.) 500 55 41 See pages 4.1 - 4.25 for selection information. DIL above 50dB may be limited due to noise flanking around the silencer or along the duct walls. If more than 50dB DIL is required, contact your local Vibro-Acoustics Representative or call 1-800-565-8401. Pressure Drop (PD) 60 34 21 16 60 27 11 27 43 49 34 16 29 35 21 + 1000 - 1000 19 +9 3500 1.11 1.81 1.01 1.56 1.11 1.46 1.01 1.28 33 30 19 19 19 15 15 15 14 14 14 29 13 29 13 13 : Acceptable (0 - 0.35”) : Caution (>0.35”) Pressure Drop may be too high for certain applications 1.01 1.23 8000 46 41 39 44 48 +12 Copyright © 2010 Vibro-Acoustics CFL-LV-F1 CFL-LV-F2 CIRCULAR FILM LINED LOW VELOCITY SILENCER (<1500 FPM) HOW TO SPECIFY: EXAMPLE CERTIFIED PERFORMANCE DATA 24 X CFL-LV-F2 X 72 Silencer Duct Connection Model Size Insertion Loss (IL) + : “forward flow” where noise & airflow move in same direction (e.g. supply side) - : “reverse flow” where noise & airflow move in opposite directions (e.g. return side) DC (in.) SL (in.) 12 24 24 48 36 72 48 96 60 120 FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 1000 3 6 12 20 30 44 49 20 6 11 19 27 42 49 20 16 24 35 46 40 13 0 3 6 - 1000 3 7 + 1000 3 12 17 19 24 0 3 7 - 1000 5 10 20 30 5 10 18 28 12 23 + 1000 0 + 1000 - 1000 3 5 12 6 12 6 - 1000 7 0 + 1000 7 7 15 10 6 0 + 1000 7 19 24 22 29 37 43 47 49 40 20 13 23 34 45 40 13 29 35 38 27 10 32 32 31 37 34 35 34 32 39 37 34 33 32 27 10 21 9 21 21 9 9 13 25 33 34 30 19 9 13 23 32 30 28 19 9 13 24 32 32 29 19 SL (in.) 12 36 24 10 27 DC (in.) 9 72 36 108 48 144 60 180 Silencer Length DC - Duct Connection Size (inches) SL - Silencer Length (inches) FACE VEL. OCTAVE BAND - Hz/D.I.L. (dB) 125 250 500 1000 2000 4000 8000 (ft. per min.) 63 - 1000 4 9 0 4 9 - 1000 5 10 + 1000 4 9 18 29 25 35 16 0 5 10 25 - 1000 7 14 29 + 1000 7 + 1000 0 - 1000 0 + 1000 - 1000 0 + 1000 5 10 7 14 14 9 18 30 17 28 35 55 48 60 59 DUCT SILENCER SILENCER CONNECT. OUTER LENGTH WEIGHT SIZE (in.) DIA. (in.) (in.) (lbs) 12 12 24 24 36 36 48 48 20 20 32 32 44 44 56 56 60 68 60 68 24 36 48 72 72 108 96 144 87 114 279 379 589 798 1026 1416 48 55 41 56 28 40 46 54 46 35 43 37 45 34 36 35 42 44 43 120 1589 44 29 13 44 42 29 13 46 180 2232 3000 3500 0.02 0.08 0.19 0.33 0.52 0.74 1.01 0.03 0.10 0.23 0.40 0.63 0.90 Pressure drops are reported in accordance with ASTM E477 methods and are based upon IDEAL flow conditions (5 diameters of straight duct on silencer inlet and 10 on outlet). Less than ideal conditions will result in an increase in pressure drop due to System Effects. See Silencer System Effects Data on page 4.19. Generated Noise (GN) @ 3 sq.ft. face area LENGTH FACE VELOCITY (inches) (feet per minute) ALL - 1500 - 1000 + 1000 + 1500 GN correction chart at right must be used to correct GN to other face areas. OCTAVE BAND - Hz/GENERATED NOISE (dB re 10 -12 watts) 63 125 250 500 1000 2000 4000 62 57 56 61 54 49 48 53 FACE AREA (sq.ft.) Questions? 1-800-565-8401 dB We reserve the right to improve our designs and data at any time without notice. 50 45 45 50 1.5 -3 48 43 42 47 3 0 5.156 46 41 38 43 6 +3 47 42 39 44 12 +6 44 39 37 42 24 +9 15 48 44 2500 0.82 1.33 0.74 1.15 0.82 1.07 0.74 0.94 15 14 2000 0.57 0.92 0.52 0.80 0.57 0.74 0.52 0.65 19 33 1500 0.36 0.59 0.33 0.51 0.36 0.48 0.33 0.42 19 19 49 48 1000 0.20 0.33 0.19 0.29 0.20 0.27 0.19 0.23 30 15 500 0.09 0.15 0.08 0.13 0.09 0.12 0.08 0.10 41 30 30 41 FACE VELOCITY (feet per minute) / Pressure Drop (in.w.g.) 0.02 0.04 0.02 0.03 0.02 0.03 0.02 0.03 55 41 49 50 48 43 See pages 4.1 - 4.25 for selection information. DIL above 50dB may be limited due to noise flanking around the silencer or along the duct walls. If more than 50dB DIL is required, contact your local Vibro-Acoustics Representative or call 1-800-565-8401. Pressure Drop (PD) 60 28 19 19 60 41 55 9 19 49 58 42 9 60 46 42 35 9 60 60 34 18 18 60 43 24 9 9 44 1.11 1.81 1.01 1.56 1.11 1.46 1.01 1.28 33 33 29 14 14 13 : Acceptable (0 - 0.35”) : Caution (>0.35”) Pressure Drop may be too high for certain applications 1.23 8000 46 41 39 44 48 +12 Copyright © 2010 Vibro-Acoustics CFL-LV-F2
© Copyright 2026 Paperzz