210 SONG CHUAN Features ϭʳ 12A/14A/16A miniature PCB Power Relay. ϭʳ Contact gap can be greater than 1.85 & 2.1 mm. ϭʳ Conforms to European photovoltaic standard IEC 62109-1. ϭʳ Coil holding voltage can be reduced to 45~60%(for 210), 45~55%(for 210H) V of the nominal coil voltage for saving energy. ϭʳHigh performance PCB power relay for photovoltaic power generation systems (solar inverter). ϭʳ Complies with RoHS-Directive 2011/65/EU. Type List ϬʳStandard type Terminal Contact Insulation Designation (provided with) style form system Flux tight 2A PCB terminal 210-2AH-F-C F (DPNO) 210-2AH1-F-C ϬʳHigh power type 2A PCB terminal 210H-2AH-F-C F (DPNO) 210H-2AH1-F-C Ordering Information 210 1 1. 210 2 2A 3 H 4 5 -- Basic series designation 6 C 7 8 6. Blank F -- Standard type -- Class F -- High power type 7. C -- Flux tight 3. 2A -- Double pole normally open 8. 4. H -- Contact material Ag alloy -- Coil voltage (please refer to the coil rating data for the availability) 2. Blank -- Standard type H 5. Blank -- Contact gap ≧1.85mm 1 -- Contact gap ≧2.1mm Contact Rating ϬʳStandard type Resistive load 12A 250VAC, On 1s /Off 9s, at 85°C, 30K ops. ϬʳHigh power type Resistive load 14A 250VAC, On 1s /Off 9s, at 85°C, 30K ops. 16A 250VAC, On 1s /Off 9s, at 75°C, 30K ops. 91 210 SONG CHUAN Coil Rating (DC) ɚ!For contact gap ɸ1.85 mm Rated Rated current Coil resistance voltage 10 % at 23°C 10 % at 23°C (V) 12 (mA) (:) 118 Pick up Drop out voltage voltage (Max.) (Min.) at 23°C (1) at 23°C 75 % of 5 % of 102 rated rated voltage voltage Power Continuous voltage at 85°C (2) (3) consumption at rated / holding voltage (210) 45~60%Ε approx. (210H) 45~55% of rated 1.4W / 0.29W (2) voltage NotesΚ(1) To energize relay properly apply 100%~120% nominal coil voltage for 200ms. (2) Coil holding voltage is 45~60%(for 210)、45~55 %( for 210H) of nominal voltage after applying nominal voltage for 200ms. (3) At 85°C for contact rating 12A, 14A; at 75°C for contact rating 16A. ɚ!For contact gap ɸ2.1 mm Rated Rated current Coil resistance voltage 10 % at 23°C 10 % at 23°C (V) 12 (mA) (:) 118 Pick up Drop out voltage voltage (Max.) (Min.) at 23°C (1) at 23°C 80 % of 5 % of rated rated voltage voltage 102 Power Continuous voltage at 85°C (2) (3) consumption at rated / holding voltage (210) 45~60%Ε approx. (210H) 45~55% of rated 1.4W / 0.29W (2) voltage NotesΚ(1) To energize relay properly apply 100%~120% nominal coil voltage for 200ms. (2) Coil holding voltage is 45~60%(for 210)、45~55 %( for 210H) of nominal voltage after applying nominal voltage for 200ms. (3) At 85°C for contact rating 12A, 14A; at 75°C for contact rating 16A. Specification Ag alloy Contact material Contact resistance (1) 100m:Max. (at 1A/6VDC by 4-wire resistance measurement) Operate time (1) 20ms Max. (1) 15ms Max. Release time Vibration resistance Shock resistance Life expectancy Operating ambient temperature Weight Operating extremes 10Д55Hz , amplitude 1.5 mm Damage limits 10Д55Hz , amplitude 1.5 mm Operating extremes 10G Damage limits 100G Mechanical 100,000 ops. (frequency 9,000 ops./hr) -40Д+85°C for contact rating 12A,14A -40Д+75°C for contact rating 16A Approx. 17 g NoteΚ(1) Initial value. Operate and release time excluding contact bounce. (2) All tests are conducted under room temperature and room humidity. (3) Consider the heat of PCB is necessary, please check the actual condition of PCB. (4) Applying no diode to this relay. The life expectancy will be lower when a diode is used. To use a varistor (ZNR) could absorb the coil surge of relay that is recommended. 92 210 SONG CHUAN (5) Do not use the relay exceeding the coil rating, contact rating and life expectancy, or this may cause the risk of overheating. (6) To assure optimum performance, avoid the relay from dropping, hitting, or other unnecessary shocks. (7) Do not switch the contacts without any load as the contact resistance may become increased rapidly. (8) Please contact Song Chuan for the detailed information. Insulation Data Insulation resistance (1) Dielectric strength 1000M:Min. (DC 500V) (1) Between open contact : AC 1500V, 50/60Hz 1 min. Between contact and coil : AC 5000V, 50/60Hz 1 min. Between contact circuits : AC 2500V, 50/60Hz 1 min. Between coil to contact : Double, Reinforce ≧ 3 mm / ≧ 5 mm Between open contact : Basic, ≧ 1.5mm / ≧ 2.5mm Between contact circuits : Double, Reinforce ≧ 3 mm / ≧ 5 mm Insulation of IEC 61810-1 Clearance / creepage distances Rated insulation voltage 250V Rated impulse withstand voltage 2500V Pollution degree 2 Rated voltage 230 / 400V Overvoltage category II Compliant with European photovoltaic standard 1.85mm Min. (IEC 62109 and VDE 0126) Contact gap 2.1mm Min. (IEC 62109 and VDE 0126) NoteΚ(1) Initial value. Safety Approval Certified UL / CUL VDE File No. E88991 40007827 Safety Approval Rating UL / CUL 210 VDE 210H NO : 16A 277VAC NO : 14A 277VAC NO : 12A 277VAC 210 NO : 12A 250VAC T85 210H NO : 16A 250VAC T75 NO : 14A 250VAC T85 Outline Dimensions 12.5 29 (0.492) 0.3 0.6-4 (0.024) 0.5X0.5-2 5.0 (0.197) (0.012) 3.5 (0.138) 25.1 (0.988) (1.142) (0.020X0.020) 20 (0.787) 2.4 (0.094) 1.5-4 (0.059) TOLERANCE: LESS THAN: 1(0.039) ±0.1(0.004) 5(0.197) ±0.3(0.012) 20(0.787) ±0.5(0.020) MORE THAN: 20(0.787) ±1(0.039) 93 210 SONG CHUAN Wiring Diagram BOTTOM VIEW PC Board Layout BOTTOM VIEW 20 0.9X2 -4 (0.787) (0.035X0.079) Ø1.3-2 7.5 (0.295) (0.051) 5.0 (0.197) Engineering Data Coil operating range (210H) Coil operating range (210) 220 200 180 160 0A 140 12A 120 With coil voltage 100% 80 Without coil voltage 60 180 160 140 20 40 60 80 16A 100 With coil voltage 100% 80 Without coil voltage 60 40 20 0 14A 120 100 0 20 40 60 80 Coil temperature rise (210) 100 Temperature rise ( °C) 110 100 90 80 70 60 12A 30 20 10 35 0A 45 55 65 75 85 80 70 50 40 95 105 % of Nominal coil voltage (at 85°C) 0A 30 45 55 110 90 80 16A 70 60 14A 50 40 0A 30 90 80 70 60 50 30 20 10 35 45 55 65 75 85 95 105 % of Nominal coil voltage (at 23°C) 16A 40 0A 35 45 55 Temperature rise ( °C) 90 80 70 60 14A 0A 35 45 55 65 75 85 95 105 % of Nominal coil voltage (at 85°C) 94 ———— All specifications subject to change. 65 75 85 95 105 % of Nominal coil voltage (at 75°C) 100 20 10 105 110 110 30 95 85 100 Coil temperature rise (210H) 40 75 Coil temperature rise (210H) 130 120 50 65 130 120 100 20 10 12A 60 % of Nominal coil voltage (at 23°C) 130 120 40 90 Coil temperature rise (210H) 130 120 50 110 100 20 10 35 Ambient temperature (°C) Ambient temperature (°C) Temperature rise ( °C) 0A Temperature rise ( °C) 100 130 120 Temperature rise ( °C) 220 200 40 20 Coil temperature rise (210) 260 240 Coil voltage(%) Coil voltage(%) 260 240 Please contact Song Chuan for update. ————
© Copyright 2026 Paperzz