ALTER User manual How to switch on Press and hold the button. While holding the button you will observe all the display indicators lighting up for you to have visual control of their operation. Also this process includes device self-test and setting of reference pressure. After that the display shows ‘0’ (or your pre-set elevation). Here release the button – the altimeter is ready for a jump. How to switch off An altimeter may be switched off only in ‘on ground’ mode. After the device is switched it turns off automatically after 14 hours (if it is in ‘on ground’ mode). In order to switch the device off manually press and hold the button to browse through the menu. When the “OFF” option appears, release the button. Here the accidental shutdown sequence begins: like in an AAD you will see digits ‘3333’, ‘2222’, ‘1111’ – shortly press the button each time you see the digits. Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter. How to check battery charge How to switch on/off backlight Logbook In order to check battery charge press the button the hold until you see the bars representing the charge. If you continue holding the button, other options of menu will follow. In order to switch the backlight on press the button and hold. When ‘led’ option appears release the button. The same procedure for switching off. In order to look through the logbook press the button and hold. When ‘log’ option appears release the button (this option is available only in ‘on ground’ mode). You jumping statistics follows: JMPS – total number of jumps SPD – maximum speed during previous jump FFT – Freefall time Alt – Deploy altitude After that the device switches to ‘on ground’ altitude display. Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter. Jump counter editing In order to look through the logbook press the button and hold. When ‘log’ option appears release the button (this option is available only in ‘on ground’ mode). Then when you see «JMPS» again press and hold the button. If you want to increase the number of jumps release the button when «Add» option appears. Current number of jumps on the display starts to blink. Pressing / holding the button, set the required number of jumps. After setting the desired value do not touch the button, the counter will stop flashing and the altimeter will enter "on the ground" mode If you want to decrease the number of jumps release the button when «Sub» option appears. Current number of jumps on the display starts to blink. Pressing / holding the button, set the required number of jumps. After setting the desired value do not touch the button, the counter will stop flashing and the altimeter will enter "on the ground" mode Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter. Elevation offset Elevation may be set within -300m to 300m range. In order to set elevation press the button and hold until ‘SET0’ appears, then release. Zero (or current elevation of grounding area) on the display starts to blink. To increase the elevation by 5m shortly press the button. Upon long hold of button the value of elevation starts to change fast. When the value reaches 300m one more button press changes the value to -300m and all the following presses allow you to set necessary negative elevation. After the value reaches needed level release the button and wait until the light stops blinking. The altimeter goes to ‘on ground’ mode and the display will show current elevation of grounding area. Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter. Indicator of low battery charge When the battery charge reaches 40% the display shows ‘LB’ indicator (Low Battery). If possible, recharge the device in order the battery lasts longer. Before plugging the charger switch the altimeter on. Firmware update For firmware update switch on your altimeter and connect it to a computer via USB. Then press and hold the button until the indicator of battery charge goes off. Release the button. Your computer will show a USB flash named ALTER_FLASH. Windows Delete old firmware firmware.bin, then copy new firmware file instead of it. Mac Download and run mac_updater from the website. Or Open Finder. Open catalog /Applications/Utilities and launch Terminal Write following commands: «rm /Volumes/ALTER_FLASH/firmware.bin» «cd ~/Downloads» «cp alter_firmware_2_6.bin /Volumes/ALTER_FLASH» After the process of copying is over, disconnect the altimeter from a computer and press the button to complete update. After that the altimeter goes off and is ready for use. Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter. Work modes of altimeter «On ground» In the ‘on ground’ stand-by mode the altimeter displays ‘0’ (or current elevation of grounding area) and automatically calibrates for zero pressure waiting for take-off. After 5 minutes in this mode the display switches off for energy economy (at take-off it turns on automatically). Take-off is registered when average speed of climb in 8 seconds exceeds 2m/sec. At this the altimeter takes for zero the value of pressure which was recorded 30 seconds before – when the device was certainly on ground. «Climb» In climb mode the altitude is updated by 5m. Menu does not offer ‘log’, ‘OFF’ and ‘SET0’ options anymore, the device can be switched off only in ‘on ground’ mode. The altimeter goes to ‘on ground’ mode upon following conditions: - Altitude is less than 200m - Average speed of descent 0 m/sec during a minute. During long flight at the same altitude over 200m the device does not reset to zero. «Freefall » During free fall altitude is updated by 50m for easy altitude read. In this mode the button is not active and produces no effect. «Parachuting» After the canopy is deployed the altitude is updated by 5m. In this mode the button is not active and produces no effect. Parachuting is a hazardous activity that can result in injury or death. An altimeter is a mechanical device and may malfunction, even when properly designed, built, assembled, maintained and used. Do not rely upon an altimeter for your safety. Your altimeter must only be considered as an aid when checking your altitude. The needle can stick during both ascent and descent – a visual cross reference with the ground should be used in combination with the altimeter. If you have ANY problems or question, please call or e-mail us. We will do our best to help you get the most out of your Alter.
© Copyright 2026 Paperzz