Series 05 - STI Europe

Waterproof (WRP2) ReSet Call Point, (WSS3) StopperPush & StopperLatch
Series 01, 02, 05 & 11
New Waterproof (WRP2) ReSet is a unique all weather surface-mounted manual call point that mimics the feel of breaking glass whilst
offering the user the benefits and safety advantages of a glass-free resettable operating element. Specially designed for use with harsh
environments, the Waterproof ReSet is ideal for industries that are sensitive to broken glass along with outdoor applications such as: oil
rigs, ships, factories and wash-down areas. Once activated a warning flag drops into view, easily identifying that the call point that has
been operated. Also available is the New Waterproof (WSS3) StopperLatch format: once activated, a key can be used to quickly and
conveniently reset the unit, and the Waterproof (WSS3) StopperPush button is also available where a momentary push-and-release
function is required.
WRP2 ReSet
Call Point
Connection Options for
Waterproof (WRP2)
ReSet Call Point 05
680
470
Waterproof (WRP2) ReSet
Series 05 Configuration
Option 1 terminals 1 & 2
open switch closing on alarm
Option 1 terminals 1 andNormally
2
Option 1 terminals 1 and 2
1
Option 1 terminals 1 and 2
control
panel
control
panel
control
panel
Configuration series 05
1
1
2
2
2
Option 2 terminals 1 & 3
WSS3 StopperLatch
Normally open switch closing on alarm
& StopperPush
Option 2 terminals 1 andwith
3 a 470 ohm resistor fitted in series
1
470 470 470
control
panel
control
panel
control
panel
Option 2 terminals 1 andwith
3 the switch
Option 2 terminals 1 and 3
1
1
4703
3
680
3
680 680 680
control
panel
control
panel
control
panel
(STOPPERLATCH ONLY)
control
panel
control
panel
control
panel
3 terminals 1 & 4
Option 3 terminals 1 andOption
4
Normally open switch closing on alarm
Option 3 terminals 1 andwith
4 a 680 ohm resistor fitted in series
1
Option 3 terminals 1 and with
4 the switch
1
WATERPROOF
RESET
1
SERIES 05
Need help? Call our Technical Support Team on Tel: 44 (0)1527 520999
4
4
4
470
680
Technical Data for Waterproof (WRP2) ReSet Call Point,
(WSS3) StopperLatch and (WSS3) StopperPush Series 01, 02, 05 & 11
Mounting Method
(WRP2) ReSet, (WSS3) StopperLatch &
StopperPush Series 01, 02, 05 & 11
Single Configuration
& Doubleseries
Pole01Changeover
1. The New Waterproof (WRP2) ReSet call point, StopperLatch
& StopperPush is supplied complete with their own surface
mounting IP67 back box.
Waterproof
Series 01
4
4. Taking the terminal chassis, ensure that the shaped “O-Ring” is
evenly positioned inside the surrounding channel.
Waterproof (WRP2 & WSS3) Series 02
Denotes a Waterproof (WRP2) ReSet Call Point & (WSS3)
StopperLatch / StopperPush
that is
fitted with a single pole
WATERPROOF
RESET
SERIES
01
changeover switch. Both the
normally
open and normally closed
contacts are easily accessed through the installer terminals as
illustrated.
5. When the wiring connections are complete, orient the
terminal chassis onto the back box ensuring that the two hinge
tabs are at the top and central screw-hole tab at the bottom. Waterproof
Series 02
Firmly secure the terminal chassis onto the back box using theWaterproof
Series 01
4 screws provided.
Dimensions
88.63mm
470
Configuration
4
680 series 05
6. Carefully attach the ReSet / StopperLatch / StopperPush front
cover to the top of the terminal chassis using the top hinges,
and secure the retaining screw at the base using the allen key
provided.
7. Maintenance (ReSet / StopperLatch): there is no need to
replace parts, simply activate to test and reset using the reset
key provided. Note: the use of lubricants/cleaning solvents
should be avoided.
470
470
680
680
680
3. With back box in place, mark the position of the 3 fixing holes.
Drill the holes and affix using the 3 screws & rawl plugs
provided. Note: 3 screws are used to avoid distortion when
mounting on uneven surfaces.
Waterproof (WRP2) Series 01
Denotes a Waterproof (WRP2) ReSet Call Point that will interface
with most conventional fire alarm systems. It is fitted with two
internal resistors: 470 and 680 ohm. These are easily accessed
through the installer terminals as illustrated.
470
2. Ensure the conduit or cabling lines up with the conduit entries
located at both the top and bottom of the reversible back box.
To maintain IP rating it is recommended that entry to the IP67
back box is done from below, using the one or two 20mm
conduit entry holes (knockouts) as required. (Remove the
appropriate conduit threaded insert as appropriate.)
Waterproof (WRP2) Series 05
Denotes a Waterproof (WRP2) ReSet Call Point that will interface
with most conventional fire alarm systems. It is fitted with two
internal resistors: 470 and 680 ohm and a diode. These are easily
accessed through the installer terminals as illustrated.
Waterproof
Series
02
Waterproof
Series 11
470
71.9
14.7
23.5
4
680
5
Waterproof (WRP2 & WSS3)
Series 11
6
Denotes a Waterproof (WRP2)
ReSet Call Point & (WSS3)
StopperLatch / StopperPush
that incorporates
two independent
WATERPROOF
RESET
SERIES 05These provide double pole
single pole changeover switches.
changeover contacts that are easily accessed through installer
terminals as illustrated.
33.7
90.26mm
Waterproof
Series 11
FRONT VIEW
4
SIDE VIEW
88.63mm
71.9
14.7
23.5
5
33.7
6
NB: Switch arrangements shown with Waterproof (WRP2) ReSet,
(WSS3) StopperLatch & StopperPush in standby.
90.26mm
Waterproof (WRP2) ReSet Series 01
R
3
0359
Specifications
Current Rating (Series 01, 02 & 11)
3 Amps 12 - 24V DC
Current Rating (Series 02 & 11 only)
6 Amps 125 - 250V AC
Housing and Mounting Box Material
Polycarbonate
Electrical Contact Material
Silver plated brass
Operating Temperature
-20°C to +65°C
Installation Terminal Conductor Size
0.5mm to 2.5mm
Safety Technology International
Taylor House, 34 Sherwood Road
Bromsgrove, Worcestershire, B60 3DR England
Tel: +44 (0) 1527 520 999 Fax: +44 (0) 1527 501 999
Email: [email protected] Web: www.sti-emea.com
14
0359-CPR-00439
EN54-11
Type A Outdoor manual Call Point
WRP2 Series 01 only
IDWATERPROOF(WRP2)-RESET_(WSS3)STOPPERLATCH/PUSH_SERIES 05 - REVISED 02/17-042 - PRINTED IN ENGLAND
Need help? Call our Technical Support Team on Tel: 44 (0)1527 520999
R
3