The Dayton Superior Dowel Bar Splicer is a one-piece unit, integrally forged from ASTM A615 grade 60 deformed rebar
material. The splicers are available in #4 through #11 rebar sizes to be used in conjunction with the corresponding size dowelin to accomplish a mechanical splice designed to achieve 160% of specified yield (full mechanical ultimate).
The splicer can be furnished straight (D-101-A) cut to length, 90˚ and 180˚ hooked (D-102-A and D-103-A) and doubleended (D-104-A) in plain or epoxy coated finish. The splicer can also be special-ordered with a reduced diameter washer
flange or with the washer flange clipped (in more than one direction, if required) to provide adequate concrete cover, or to
avoid interference.
The D-104-A Double-Ended Dowel Bar Splicer is used to establish a direct load path through a concrete section, thus
avoiding multiple hooked rebar and eliminating rebar congestion. The double-ended unit can be configured in a “U” shape for
special applications.
Bar
Size
Thread
Size
A
B
C
D
E
Flange
Diameter
Minimum Pult Range =
95% Fu Actual or 160%
Fy Specified*
#4 [#13]
5/8"–11 UNC
1-1/8"
1/8"
11/16"
55/64"
1"
1-7/8"
19,200 lbs.
#5 [#16]
3/4"–10 UNC
1-9/16"
1/8"
13/16"
1-3/64"
1-1/8"
2-1/16"
29,760 lbs.
#6 [#19]
7/8"–9 UNC
1-11/16"
1/8"
15/16"
1-15/64"
1-1/4"
2-1/4"
42,400 lbs.
#7 [#22]
1"–8 UNC
1-27/32"
1/8"
1-1/16"
1-27/64"
1-3/8"
2-7/16"
57,600 lbs.
#8 [#25]
1-1/8"–8 UN
2-1/16"
1/8"
1-3/16"
1-19/32"
1-1/2"
2-5/8"
75,840 lbs.
#9 [#29]
1-1/4"–8 UN
2-3/16"
1/8"
1-5/16"
1-25/32"
1-5/8"
2-13/16"
96,000 lbs.
#10 [#32]
1-7/16"–8 UN
2-7/16"
1/8"
1-1/2"
2"
1-13/16"
3"
121,920 lbs.
#11 [#36]
1-9/16–8 UN
2-9/16"
1/8"
1-5/8"
2-7/32"
1-15/16"
3-1/4"
149,760 lbs.
*Loads shown based on 160% fy specified
Length As Specified
Smooth
Transition (Approx.
1/2" Fillet Radius)
+0.125
E -0.000
.250 Typ.
Rebar Size
C Dia.
D-101-A Dowel Bar Splicer
A
B±.063
NOTE: To be manufactured
as Single End
Note: No. 4, 5 and 6 splicers, 18", 24" and 36" long will
usually have a stamped metal
plug to protect threads; all
other sizes will have a plastic
cap plug.
Nail Holes
1/2" Less
Than
Flange
O.D.
Flange
Diameter ±1/8"
14
D Dia.Min
D-101-A
Minimum MFG.
Length DB-SAE
#4 (#13)
12"
#5 (#16)
14"
#6 (#19)
16"
#7 (#22)
16"
#8 (#25)
16"
#9 (#29)
16"
#10 (#32)
16"
#11 (#36)
16"
Optional
Clipped
Flange
Clipped
Flange
3/08
Threaded Splicing
Systems
Dowel Bar Splicer System
Recommended Dowel Bar Splicer and Dowel-In
Grade 60 Rebar Loads (lbs.)
Bar
Size
System
Thread
Size*
DB-SAE
Bar
Size
Dowel-In
Bar
Size
System
Stress
Area
(min.)
Completed Splice (lbs.)
Minimum Pult
Range = 95%
Py
1.25 Py Fu Actual or
160% Fy
Specified**
Py
1.25 Py
Pult
#4 [#13]
12,000
15,000
18,000
5/8"-11
#4
#4
.20
12,000
15,000
19,200
#5 [#16]
18,600
23,250
27,900
3/4"-10
#5
#5
.31
18,600
23,250
29,760
#6 [#19]
26,400
33,000
39,600
7/8"-9
#6
#6
.44
26,400
33,000
42,400
#7 [#22]
36,000
45,000
54,000
1"-8
#7
#7
.60
36,000
45,000
57,600
#8 [#25]
47,400
59,250
71,100
1-1/8"-8
#8
#8
.79
47,400
59,250
75,840
#9 [#29]
60,000
75,000
90,000
1-1/4"-8
#9
#9
1.00
60,000
75,000
96,000
#10 [#32]
76,200
95,250
114,000
1-7/16"-8
#10
#10
1.27
76,200
95,250
121,920
#11 [#36]
93,600
117,000
140,400
1-9/16"-8
#11
#11
1.56
93,600
117,000
149,760
Threaded
Splicing Systems
Specified or Required Dowel Bar
Py=Minimum Yield Strength of bar.
*5/8", 3/4", 7/8" and 1" sizes have UNC Threads. 1-1/8" and larger sizes are equipped with UN Threads.
**Loads shown based on 160% fy specified.
A
A
R
D
R
B
D-102-A 90˚ Hooked
Dowel Bar Splicer
D-103-A 180˚ Hooked Dowel
Bar Splicer
Bending DB or DI
90o only Minimum
"A" Dimension
#4 (#13)
4" *
#5 (#16)
5" *
#6 (#19)
6" *
#7 (#22)
7" *
#8 (#25)
8" *
#9 (#29)
9" *
#10 (#32)
10" *
#11 (#36)
11" *
Overall Length
(See chart below)
Overall Length
D-104-A Double-Ended
Dowel Bar Splicer
* Tolerance on Bending
Plus 0 / Minus 1" on "A" Dimension
D-104-A Double-Ended Min. Lengths
3/08
C
D-101-A Dowel Bar Splicer
Tolerance
Overall Length
See D-108 Headed Dowel Bar Splicer on page 17.
#4 [#13]
12" O.A.
+0 - 3/8"
#5 [#16]
12" O.A.
+0 - 3/8"
#6 [#19]
14" O.A.
+0 - 1/2"
#7 [#22]
16" O.A.
+0 - 5/8"
#8 [#25]
16" O.A.
+0 - 3/4"
#9 [#29]
16" O.A.
+0 - 1"
Specify: (1) quantity, (2) name, (3) bar size (should be
equivalent to the rebar being substituted for on the
structural drawings), (4) dimensions required.
#10 [#32]
16" O.A.
+0 - 1"
Example:
#11 [#36]
16" O.A.
+0 - 1"
600, D-101-A Dowel Bar Splicers, #5 rebar, 36" long.
** Based on barrels forged on each end. For lengths less than minimum
- please check with Tremont - we may supply forged DB one end, DI with
Coupler & nailer washer other end.
To Order:
15
Threaded Splicing
Systems
Threaded
Splicing Systems
Typical Dowel Bar Splicer System Installation
Formwork
Formwork
Keyway
Keyway
Tied to
Adjacent
Reinforcing
Splicer
1. Set forms, and nail or screw Splicer to
2. Place required reinforcing steel.
form key.
3. After first pour has properly
set, remove the formwork and
screw Dowel-Ins into the
exposed splicers.
Dowel-In
1st Pour
Main Reinforcing Bar
Floor Slab
Second
Pour
4. Place second
pour formwork
and reinforcing
steel.
Lap Splice Length
1st Pour
Formwork
16
3/08