ATS-186K SERIES U V S Y S T E M S Control System Stand (optional) ATS-186K SERIES U V S Y S T E M S 4 Log (99.99%) Reduction of Bacteria, Cryptosporidium and Virus Amalgam Short Vertical UV Systems Wall mounted Control System (standard) All ATS Units are Proudly Made: in the WQA Gold Seal / ANSI NSF 61 Approved U.S.A. 4 Log (99.99%) Bacteria, Cryptosporidium and Virus Reduction at >186,000uws/cm2 (186mJ/cm2) UV Dose • Amalgam High Output UV Lamps • 12,000 Hour Lamp Life • UV Chamber Overheat Control • UV Sight Port • Flange or Threaded Inlet / • Internal Water Flow Diverter Outlet Connections • Internal Multi-Level Quartz Sleeve Stabilizer • Internal Multi-Level Flow Balance System • Nema 4 Type Electrical Box Enclosure • Removable UV Lamp / • Fused Circuits Quartz Sleeve Service Rack • Power ON/OFF Switch • UV Intensity Monitor with • Drain NIST Traceable Calibrated UV Sensor • Remote PLC Monitoring Connection • Multi-Level UV Monitoring and Alarms ATS MODEL ATS-186K-10 ATS-186K-20 ATS-186K-40 ATS-186K-60 ATS-186K-80 ATS-186K-120 ATS-186K-240 ATS-186K-480 UV DOSE STANDARD FLOW GPM KW @ 120V AMPS @ 120V INLET/OUTLET PIPE SIZE MNPT >186,000uws/cm2 (186mJ/cm2) 10 0.36 3.0 1” 47.5” X 8.5” X 8.5” >186,000uws/cm2 (186mJ/cm2) 20 0.72 6.0 1” 47.5” X 11.5” X 11.5” >186,000uws/cm2 (186mJ/cm2) 40 0.84 7.0 1 1/2” 47.5” X 12.5” X 12.5” >186,000uws/cm2 (186mJ/cm2) 60 0.96 8.0 2” 47.5” X 14.5” X 14.5” >186,000uws/cm2 (186mJ/cm2) 80 1.2 10.0 2” 47.5” X 14.5” X 14.5” >186,000uws/cm2 (186mJ/cm2) 120 1.44 12.0 3” 47.5” X 16.5” X 16.5” >186,000uws/cm2 (186mJ/cm2) 240 2.16 18.0 4” 47.5” X 22.5” X 22.5” >186,000uws/cm2 (186mJ/cm2) 480 2.64 22.0 4” 47.5” X 30.5” X 30.5” ATS -STAND Control Box Mounting Stand (powder coated) ATS -THERM Adjustable Setting Thermistor Overheat Safety Control ATS - SP 1/4” Sample Port on Inlet/Outlet Riser ATS - 304NCB 304 SS #4 Brushed Finish on Nema 4 Type Control Box ATS - LT UV Light Traps on Inlet/Outlet ATS - STC Sanitary-Tri-Clamp Fittings ATS - MW Manual Quartz Slaave Wiper ATS - 316 SS 316 Stainless Steel Wetted Parts UV CHAMBER DIMENSIONS HxWxD” ESTIMATED SHIPPING WEIGHT 65 lbs 85 lbs 75 lbs 95 lbs. 165 lbs. 185 lbs 195 lbs. 225 lbs. 220V Specs are available upon request. ATS-186K UV Models provide a minimum of 186mJ/cm2 UV Dose within the UVT range and maximum design flow rate. Contact ATS for application design and UV sizing criteria. The ATS-186K UV System has been Tested and Validated per UVDGM by an Independent 3rd Party Organization Flow & UV System Dose for 4Log Reduction of Bacteria, Virus, Cysts and Adenovirus per USEPA UV Disinfection Guideline Manual (EPA 815-R-06-007) The ATS-186K UV System has been evaluated, performance tested, and verified by and Independent 3rd Party Organization at the USEPA Test and Evaluation Facility i Cincinnati, Ohio. Aqua Treatment Service, Inc 194 Hempt Rd, Mechanicsburg, PA 17050 800 . 224 . 7476 fax: 800 . 787 . 0197 www.aquat.com
© Copyright 2025 Paperzz