GS523DZ Tech Sheet Balboa System PN 54763-01 System Model # GS5-GS523DZ-RCA-3.0 Software Version # 43 EPN # 2808 Base PCBA - PN 55857-01 PCB GS500Z - PN 22015 Rev B Base Panels VL801D (Serial Deluxe) – PN 54121 VL802D – PN 54562 Template used: 40599_97_O.pdf 11/08/2008 54763-01_97_D.pdf 03/17/2009 Page 1 54763-01_97_D System Revision History System PN EPN 54763-01 54763-01 Date Requested By 2808 02.10.2009 Balboa 2808 03.17.09 Balboa Changes Made Update software to version 43. Update Tech Sheet Electrical Service Config Pages Page 2 54763-01_97_D Basic System Features and Functions Power Requirements 3INGLE3ERVICE;WIRESLINENEUTRALGROUND= s 6!#(Z^!#IRCUIT"REAKERRATING!MAX $UAL3ERVICE;WIRESLINENEUTRALLINENEUTRALGROUND= s 6!#(Z^X!#IRCUIT"REAKERRATING!MAXEACHSERVICE 0HASE3ERVICE;WIRESLINELINELINENEUTRALGROUND=Requires PCB Rev B. s 6!#(Z.^!#IRCUIT"REAKERRATING!MAXEACHPHASELINE s )-0/24!.43ERVICEMUSTINCLUDEANEUTRALWIREWITHALINETONEUTRALVOLTAGEOF6!# System Outputs Setup 1 (As Manufactured) s 60UMP3PEED s 60UMP3PEED s 60UMP3PEED s 6"LOWER s 6/ZONE s 63PA,IGHT s 6!6(Stereo) s K7(EATER Setup 2 s 60UMP3PEED s 60UMP3PEED s 60UMP3PEED s 6"LOWER s 6/ZONE s 6#IRC0UMP s 63PA,IGHT s 6!6(Stereo) s K7(EATER (EATERWATTAGEISRATEDAT6 Additional Options J71 J2A J1A s &ULL&EATURE$OLPHIN2EMOTE AND3PAONLY$OLPHIN2EMOTE J1 s )22ECEIVER-ODULE #ONNECTSTOTERMINAL*OR* -USTBEPINCONNECTOR J2 s -OOD%&8,IGHTING #ONNECTSTO3PA,IGHTTERMINAL* 1 J18 J10 s &IBER%&8,IGHTING #ONNECTSTO3PA,IGHTTERMINAL* U4 J19 J8 J7 J60 1 1 J44 1 1 J22 1 J12 EXT RLY Page 3 1 AUX F SEN A SEN B VAC J11 54763-01_97_D Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly. To reset Persistent Memory: s Power down by disconnecting power source from spa. s Put a jumper across J43, covering both pins. (See illustration below) s Power up by connecting power source to spa. s Wait until “ ” is displayed on your panel. s Power down again. s Remove jumper from J43 (May also move to cover 1 pin only) s Power up again. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of settings. What we refer to as Persistent Memory stores the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. Power Up Display Sequence Upon power up, you should see the following on the display: s Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are , that is a VS511SZ at version 38. s Displayed next is: “ ” (indicating the system is configured for a heater between 3 and 6 kW) or “ ” (indicating the system is configured for a heater effectively* between 1 and 3 kW). “ ” should appear for all VS models running at 240VAC. “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will function as a 1 kW heater at 120VAC.) s “ ” will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the Reference Card for the VS or GS System model of your spa for information about how the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. J43 TST C G J90 J46 W7 K8 K9 T1 W3 J1 J1A K5 W2 J20 F5, F3A 250V K5 G C K4 J12 W1 SWITCHBANK A J29 J50 C G FUSE 3A 250V C G C S1 TST G C G J20 OZONE J23 C W4 PUMP F1 G C J6 J43 J29 C G J47 G J6 F4 FUSE .3A 250V FUSE 20A 250V F7 J50 K1 J17/26 J23 E.GND K6 RST SWITCHBANK A K1 J10 J18 F2 J18 E.GND S1 TST SWITCHBANK A EXT. T RLY L AUX. F J7 J8 SEN. A SEN. B J1 K3 BLK AC BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D F4 K2 LINE J13 J22 J57 TST RST J6 J43 S1 J7 J8 SEN. A SEN. B J9 J26 J43 F2 J60 J58 J12 J2 J6 U4 WHT AC Balboa U4 2 3 NEUTRAL VS100 P/N 22964_B MADE IN U.S.A. © 2006 1 K3 K2 W1 J13 T0.25A 250V J2A MADE IN U.S.A V VAC COPYRIGHT 2005 HEATER A J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. SWITCHBANK A J43 on VS100/GS100 Series Main Board Shown. Page 4 54763-01_97_D Wiring Configuration and DIP Settings Setup 1 (As Manufactured) N G N J47 J322 TB1 J46 K8 C9 J20 K5 Spa LightN G F4, T0.2A 250V F3 10VAC J72 J17/26 1 J13 F3A 250V Blower N F1 F7 F10A 250V K1 K6 K9 2-Spd 1-Spd P1 P1 CIRC. PUMP G PUMP 1 Ozone J255 J23 OZONE N Audio G N Visual J29 G AV J50 J F6, T30A 480V J51 J52 Disconnect slip terminal with green wires from J90 prior to performing HiPot test. Failure to disconnect may cause a false failure of the test. Reconnect terminal to J90 after successful completion of HiPot test. s 6!6(Stereo) s K7(EATER s $ELUXE-AIN0ANEL OPT. BLWR/PUMP 2 10VAC s 6"LOWER s 6/ZONE s 63PA,IGHT G s 60UMP3PEED s 60UMP3PEED s 60UMP3PEED HIPot Testing Note: J71 T1 2 J2A J1A J58 J1 W2 J288 J2 K3 J266 3 1 J43 K4 U4 J57 K2 00 J19 S1 J90 J6 3.0 kW 1 TST SWITCHBANK A J8 J7 J60 1 1 EXT RLY 1 AUX F SEN A SEN B VAC J7 Red R P/N 22909 REV B B W G PS-23 W1 J11 3.0kW X-P332 CE PN 55138 J1 GS5xxDZ mode 1 Heater rated @ 240V J11 must be Jumpered Note: Configuration shown is for Single Service only, see the Electrical Service pages (8, 9, 10) for instructions on converting to Dual Service or 3-Phase. J12 J44 1 J6 White Pump 2 HTR1 To J1 on X-P332 J101 HTR2 J22 BALBOA INSTRUMENTS, INC. GS500Z PPbb COPYRIGHT 2007 MADE IN U.S.A. P/N 22015_B F2 W1 E.GND Balboa J18 J10 Green Black F30A 480V White To J57 or J58 on Main PCBA Pump 3 4 Green WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # 100 91 43 J11 J12 3.0kW Heater A1, Test Mode OFF A2, See Table 1 A3, N/A A5, 2-speed P1 Panel Button Assignments 1=Time 2=Mode/Prog 3=Temp Up 4=Temp Down GS523DZ Software 5=Light 6=Pump 1 7=Pump 2 8=Unused 8=J17/26 A6, 50 Hz Enabled A7, J17/26 Disabled A8, Degrees C A9, Non-Circ Mode A10, See Table 1 Wiring Color Key Neutral (Common) AC Connections 3 Special AC Connections 2 Line AC Connections 1 10 Volt Connections Relay Control Wires J43 Memory Reset Panel Button Positions 1 3 8 5 2 4 6 7 Page 5 Board Connector Key 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps 3 Neutral (Common) 4 Ground Note flat sides in connector 54763-01_97_D Wiring Configuration and DIP Settings Setup 2 J47 G TB1 J46 K8 C9 J20 K5 Spa LightN G F4, T0.2A 250V F3 10VAC J72 J17/26 1 J13 F3A 250V Blower J322 F1 F7 F10A 250V K1 K6 K9 2-Spd 1-Spd P1 P1 G Circ N Pump J255 PUMP 1 Ozone CIRC. PUMP J23 OZONE N Audio G N Visual J29 G AV J50 J F6, T30A 480V J51 J52 Disconnect slip terminal with green wires from J90 prior to performing HiPot test. Failure to disconnect may cause a false failure of the test. Reconnect terminal to J90 after successful completion of HiPot test. s K7(EATER s $ELUXE-AIN0ANEL OPT. BLWR/PUMP 2 10VAC 6/ZONE 6#IRC0UMP 63PA,IGHT 6!6(Stereo) N s s s s G 60UMP3PEED 60UMP3PEED 60UMP3PEED 6"LOWER N s s s s HIPot Testing Note: J71 T1 2 J2A J1A J58 J1 W2 J288 J2 K3 J266 3 1 J43 K4 4 U4 J57 K2 00 J19 S1 J90 J6 1 TST SWITCHBANK A J8 J7 J60 1 1 J12 J44 1 GS5xxDZ mode 1 EXT RLY 1 AUX F SEN A SEN B VAC J11 3.0kW 3.0 kW J1 Red P/N 22909 REV B B W G PS-23 1 J7 J6 White Pump 2 X-P332 CE PN 55138 R Note: Configuration shown is for Single Service only, see the Electrical Service pages (8, 9, 10) for instructions on converting to Dual Service or 3-Phase. To J1 on X-P332 Heater rated @ 240V J11 must be Jumpered HTR1 Green Black F30A 480V White To J57 or J58 on Main PCBA Pump 3 J101 HTR2 J22 BALBOA INSTRUMENTS, IN GS500Z COPYRIGHT 2007 MADE IN U.S.A. P/N 22015_B F2 W1 E.GND Balboa J18 J10 Green WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # 100 91 43 J11 J12 3.0kW Heater A1, Test Mode OFF A2, See Table 1 A3, N/A A5, 2-speed P1 Panel Button Assignments 1=Time 2=Mode/Prog 3=Temp Up 4=Temp Down GS523DZ Software 5=Light 6=Pump 1 7=Pump 2 8=Unused 8=J17/26 A6, 50 Hz Enabled A7, J17/26 Disabled A8, Degrees C A9, Non-Circ 24 Hour 3ºF Circ Pump A9, Mode A10, See Table 1 Wiring Color Key Neutral (Common) AC Connections 3 Special AC Connections 2 Line AC Connections 1 10 Volt Connections Relay Control Wires J43 Memory Reset Panel Button Positions 1 3 8 5 2 4 6 7 Page 6 Board Connector Key 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps 3 Neutral (Common) 4 Ground Note flat sides in connector 54763-01_97_D DIP Switches and Jumpers Definitions SSID 100 91 43 Base Model GS523DZ DIP Switch Key A1 Test Mode (normally OFF) A2+A10 Control amp draw requirements (See Table 1) A3 N/A (must be OFF) A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: Table 1 A5 A9 Circ Mode Pump 1 Speed OFF ON OFF ON OFF OFF ON ON Non-circ Circ "acts like Pump 1 low" (filters/polls/ect) 24 hours with 3°F shut-off 24 hours with 3°F shut-off 2-speed 1-speed 1-speed 2-speed A2 # of Hi-Speed Pumps/Blower Before Heat Disabled A10 OFF ON OFF ON OFF OFF ON ON 0 1 2 3 Alert: A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: J17/26 Enabled for Blower or 1-speed Pump 4. “OFF” position: J17/26 Disabled. A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit Pump 2 and Pump 3 are required, use X-P332 CE expander board with PS-23 splitter cable. To add Blower or 1-speed Pump 4, use J17/26. Jumper Key J11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2. If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only. J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software. Jumper must be on Pins 2 and 3 for GS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: sSetting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system. sContact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions Aux Panel Information 1 3 8 5 Supports 2-button aux panel 2 4 6 7 VX20 6 7 Supports 4-button aux panel Panel Button Assignments 1=Time 2=Mode/Prog 3=Temp Up 4=Temp Down VX40D 6 7 8 5 5=Light 6=Pump 1 7=Pump 2+Pump 3 8=J17/26 (when A7 is ON) Page 7 54763-01_97_D Electrical Service Configuration Options Systems with PCB Rev B Only AV J50 J52 J F6, T30A 480V J51 G J29 J23 OZONE PUMP 1 F1 F7 F10A 250V K1 K6 K9 J13 F3A 250V N J47 J46 Single Service, TN and TT Electrical Systems CIRC. PUMP N G N K8 N N G G J255 (1 x 32 Amp) 10VAC J17/26Line + J72 1 Neutral + 1 Protective Earth) 3 Wires (1 J71 G N 10VAC F4, T0.2A 250V OPT. BLWR/PUMP 2 T1 J58 Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. 2 J1 W2 This option is configured and shipped as the default. J2 J288 3 K3 J266 N1 J20 J2A J1A 1 L1 K5 F3 TB1 All equipment (pumps, blower, heater and any expander board) runs on service line L1. 1 4 J43 K4 J57 BALBOA INSTRUMENTS, INC. GS500Z PPbb COPYRIGHT 2007 MADE IN U.S.A. P/N 22015_B F2 W1 J101 HTR2 HTR1 J90 To power on an optional fuse-protected Expander Board. To W1 on an optional fuse-protected Expander Board. AV J50 J52 K2 00 J19 Systems using only 1 DIP switch (A10) for heat disable: 1 x 16 Amp Service is not supported: For 1 x 32 Amp Service: Set DIP Switch A10 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table 1 such that total system amperage draw never exceeds rated service input. S1 J6 J F6, T30A 480V J51 G J29 J23 OZONE PUMP 1 TST SWITCHBANK A 1 1 EXT RLY 1 J12 1 1 J11 VAC SEN B SEN A AUX F F1 F7 F10A 250V K1 K6 K9 1 J44 J8 J7 J60 J22 Balboa J18 J10 U4 E.GND AS MANUFACTURED C9 G J322 J13 F3A 250V N J47 J46 Dual Service, TN and TT Electrical Systems CIRC. PUMP N G N K8 N N G G J255 OPT. BLWR/PUMP 2 T1 J1 The heater and any expander board run on J2 service line L1, while all other equipment, such as pumps and blowers, run on service line L2. J288 N1 N Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. W2 K3 J266 1 4 J43 K4 J57 BALBOA INSTRUMENTS, INC. GS500Z PPbb COPYRIGHT 2007 MADE IN U.S.A. P/N 22015_B Completely remove the white wire from J26 and J32. Note: J32 and J25 are electrically identical. The white wire may be attached to either terminal before removal. F2 W1 HTR2 To W1 on an optional fuse-protected Expander Board. J101 HTR1 00 K2 J90 To power on an optional fuse-protected Expander Board. J19 S1 J6 J60 1 TST SWITCHBANK A J8 J7 1 1 J12 J44 1 1 J22 Balboa J18 J10 U4 E.GND OPTIONAL 3 G 10VAC F4, T0.2A 250V J58 L1 J20 J2A J1A 1 L2 2 K5 F3 TB1 N2 C9 (2 x 16 Amp) 10VAC J17/26LinesJ72+ 2 Neutrals + 1 Protective Earth) 5 Wires (2 J71 G J322 EXT RLY 1 AUX F SEN A SEN B VAC J11 Systems using only 1 DIP switch (A10) for heat disable: DIP Switch A10 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions. If using an Expander Board: Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to OFF positions. Page 8 54763-01_97_D Electrical Service Configuration Options Systems with PCB Rev B Only AV J50 J52 J F6, T30A 480V J51 G J29 J23 OZONE PUMP 1 F1 F7 F10A 250V K1 K6 K9 J13 F3A 250V N J47 J46 3-Phase Service, TN and TT Electrical Systems CIRC. PUMP N G N K8 N N G G J255 C9 G J2A J1A 2 W2 J288 3 K3 J266 1 4 J43 K4 J57 F2 W1 HTR2 To W1 on an optional fuse-protected Expander Board. J101 HTR1 00 K2 J90 To power on an optional fuse-protected Expander Board. J19 S1 J6 J60 TST SWITCHBANK A 1 1 J12 J44 J8 J7 1 1 1 J22 Balboa BALBOA INSTRUMENTS, INC. GS500Z PPbb COPYRIGHT 2007 MADE IN U.S.A. P/N 22015_B J18 J10 U4 E.GND OPTIONAL Protective Earth wire (Green/Yellow) must be connected J71 to system ground terminal as marked. IMPORTANT - Service MUST include a neutral wire, J1 with a line to neutral voltage of 230VAC. J2 The heater runs on service line L1. All main-board equipment run on service line L3. Addtional equipment, such as expansion boards, run on service line L2. Completely remove the white wire from J26 and J32,or J25. Completely remove the blue wire from J28 and J58. OPT. BLWR/PUMP 2 J58 N 10VAC F4, T0.2A 250V T1 L1 N F3 10VAC J72 J17/26 1 L2 J20 G TB1 L3 K5 5 Wires (3 Lines + 1 Neutral + 1 Protective Earth) J322 EXT RLY 1 AUX F SEN A SEN B VAC J11 Systems using only 1 DIP switch (A10) for heat disable: DIP Switch A10 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions. NOTE: sNot all GS5xxZ systems can support 3-Phase. s3-Phase requires System PCB Rev B. sIf using an expansion board, the board must have fuse-protection. Page 9 54763-01_97_D Electrical Service Application Notes This page is specific to the GS523DZ model with 7A max pumps. (The preceeding pages cover all possible GS applications.) As manufactured, this system comes configured for Single Service. See the preceding pages for instructions on moving wires for Dual Service or Three-Phase configurations. Use the following guidelines for setting DIP Switches appropriately for the particular service configuration chosen. For 1x16A Service: Not Supported. For 1x32A Service: Switch A2 must be OFF and A10 can be ON. For 2x16A Service: Switches A2 and A10 must be OFF (because Pumps 2 and 3 are on the same service as the Heater). For 3-phase Service (16A per phase): Pump 1 and blower are on one phase, Pumps 2 and 3 are on another phase, and the Heater is on its own phase. So there are no limitations needed on equipment running together. Thus switches A2 and A10 can both be ON. Page 10 54763-01_97_D Ozone Connections Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 230VAC 50Hz: L Black or Brown Line Conductor Empty White or Blue Neutral Conductor Empty N Flat sides of sockets as shown J50 Audio G R B W Visual J29 J23 OZONE PUMP 1 2-Spd P1 R J51 F6, T30A 480V CIRC. PUMP B J47 W G Circ R B W Pump J25 J32 Line - Black or Brown conductor Not used Neutral - White or Blue conducto Not used G J52 AV TB1 1 F4, T0.2A 250V J90 J58 2 W2 J57 J28 Page 11 54763-01_97_D Serial Deluxe Panel Configurations Time Warm Blower Light Mode/Prog Cool Jets 1 Jets 2/3 VL801D (Serial Deluxe) PN 54121 no Overlay s Connects to Main Board terminal J1 only* Time Warm Blower Light Mode / Prog Cool Jets 1 Jets 2/3 VL802D PN 54562 no Overlay s Connects to Main Board terminal J1 only* * Panels with back-lighting (bulbs installed) should never be plugged into J2. Use J1 only. If the backlight bulbs are removed, then both J1 and J2 may be used. Page 12 54763-01_97_D
© Copyright 2026 Paperzz