MSU RILEY CENTER Sound FOH Board: Crest X8 40-ch (New Jersey), 8 subs, 8 aux, matrix, phase reversers Power: Crest Speakers: Flown Architectural Acoustics arrays, fully bi-amped, left and right with subs (may be run separately) and under-balcony fills; processed with Digitool system EQ and delays FOH processing: Klark Teknik EQ, 2 Yamaha SPX2000, 1 Lexicon PCM 81, 1 TC Electronic D-Two effects, 4-ch dbx 1066, 8-ch dbx 166 compressor/gates Monitor speakers: 16 QWM wedges (15” LF, 2” HF) Microphones, stands, DIs and cables Specifications Line sets: 36 single purchase, 9 double purchase; see line set schedule. STAGE Arbor capacity: See line set schedule. Loading: High gallery Stage Dimensions Proscenium: 29’4”w 19’4” h Operating: 2-36 SL floor, 1 and 37-45 SL midgallery Depth: 32’6” Available weight: 5 tons (estimated) Apron: 7’2” at center Wing left: 8’4” Wing right: 12’6” Hallway behind stage Stage height: 41” above audience floor FOH Access Floor: Maple with dark brown stain. Sprung for dance. Screws must be predrilled; lags must be plugged. Stage left; removable stairs at center aisle Drapery See line set schedule for locations. Lighting Main act: Brick red with gold trim, will fly or travel, manual operation Control: ETC Expression with Emphasis Legs: 2 sets black velour 24’ x 12’ Dimmers: 204 2.4 kW ETC dimmers Teasers: 1 brick red with gold trim 34’ x 9’ with fullness, 3 black velour 40’ x 6’ with fullness Fixtures: 138 S4 575 W (6 – 10 deg, 12 – 14 deg, 26 – 19 deg, 44 – 26 deg, 30 – 36 deg, 20 – 50 deg) Travelers: 2 black velour 24’ x 40’, operate SL 48 S4 PAR 575 W Blackout: 24’ x 40’ no fullness 16 S4 PARNel 575 W Scrim: 24’ x 40’ black 12 Altman Fresnel 750 W Bounce: 24’ x 40’ white 8 Altman 3-cell far cyc Cable and accessories 2 Lycian 575 follow spots Line Set Data Grid height: 50’7” Batten high trim: 48’8” Batten low trim: 4’ Battens: 1½” Schedule 40, 40’ long, 4 lift lines on 11’4” centers Crossover CD and cassette Dressing room monitor and paging Clear-Com production intercom DRESSING ROOMS 6 total, 5 with showers. All have lavatories. Production office with Internet and phone LOAD-IN Street level, freight elevator to stage 14’ x 10’ x 7½’ h For additional information, please contact William Nix, Riley Center Technical Director, at 601-696-2211 or [email protected]. LIGHTING AND SOUND Lighting positions: 2 FOH slots with 22 circuits each, 2 box booms with 5 circuits each 6 circuits on balcony rail 4 OS electrics Cyc electric 2200 Fifth Street • Meridian, MS 39301 Phone: 601-696-2211 • Fax: 601-696-2300 www.msurileycenter.com For additional information, contact: William Nix Riley Center Technical Director E-mail: [email protected]
© Copyright 2026 Paperzz