VS510SZ Tech Sheet Balboa Instruments System PN 54371-02 System Model # VSP-VS510SZ-DCAH Software Version # 43 EPN # 2765 Base PCBA - PN 54372-02 PCB VS500Z - PN 22972 Rev C or D Base Panels VL700S – PN 53811 VL701S (Serial Standard) – PN 53189-01 VL702S – PN 54652 Template used: 40600_P.pdf 01/07/2008 54371-02_97_A.pdf 04/14/2008 Page 1 54371-02_97_A System Revision History System PN EPN 54371-01 54371-02 Date Requested By 1801 08.09.2006 Balboa 2765 04.14.2008 Balboa Changes Made n/a Software update to v43 Page 2 54371-02_97_A Basic System Features and Functions Power Requirements s 6!#(Z!#LASS!'&#)PROTECTEDSERVICE#IRCUIT"REAKERRATING!MAX s WIRES;HOTHOTNEUTRALGROUND= System Outputs Setup 1 (As Manufactured) s 60UMP3PEED s 60UMP3PEED s 6"LOWER s 6/ZONE s 63PA,IGHT s 6!6(Stereo) s 6K7(EATER Optional Devices s 6#IRC0UMP Additional Options K8 W3 s &ULL&EATURE$OLPHIN2EMOTE AND3PAONLY$OLPHIN2EMOTE FUSE /ZONEAND#IRC0UMPMUSTBESAMEVOLTAGE (EATERWATTAGEISRATEDAT67HENRUNNING6TOHEATEROUTPUTISAPPROXIMATELY K5 W2 J1 J1A J10 s )22ECEIVER-ODULE #ONNECTSTOTERMINAL*OR* J2A J18 s -OOD%&8,IGHTING #ONNECTSTO3PA,IGHTTERMINAL* 1 U4 s &IBER%&8,IGHTING #ONNECTSTO3PA,IGHTTERMINAL* 2 3 J12 J2 J13 Page 3 J60 J22 EXT. RLY AUX. F J7 J8 SEN. A SEN. B BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D VAC MADE IN U.S.A COPYRIGHT 2005 54371-02_97_A Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. If you do not reset Persistent Memory, your system may function improperly. To reset Persistent Memory: s Power down by disconnecting power source from spa. s Put a jumper across J43, covering both pins. (See illustration below) s Power up by connecting power source to spa. s Wait until “ ” is displayed on your panel. s Power down again. s Remove jumper from J43 (May also move to cover 1 pin only) s Power up again. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of settings. What we refer to as Persistent Memory stores the filter settings, the set temperature, and the heat mode. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. Power Up Display Sequence Upon power up, you should see the following on the display: s Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, which should match the version of your system. For example, if these three numbers are , that is a VS511SZ at version 38. s Displayed next is: “ ” (indicating the system is configured for a heater between 3 and 6 kW) or “ ” (indicating the system is configured for a heater effectively* between 1 and 3 kW). “ ” should appear for all VS models running at 240VAC. “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will function as a 1 kW heater at 120VAC.) s “ ” will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the Reference Card for the VS or GS System model of your spa for information about how the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. J43 TST C G J90 J46 W7 K8 K9 T1 W3 J1 J1A K5 W2 J20 F5, F3A 250V K5 G C K4 J12 W1 SWITCHBANK A J29 J50 C G FUSE 3A 250V C G C S1 TST G C G J20 OZONE J23 C W4 PUMP F1 G C J6 J43 J29 C G J47 G J6 F4 FUSE .3A 250V FUSE 20A 250V F7 J50 K1 J17/26 J23 E.GND K6 RST SWITCHBANK A K1 J10 J18 F2 J18 E.GND S1 TST SWITCHBANK A EXT. T RLY L AUX. F J7 J8 SEN. A SEN. B J1 K3 BLK AC BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D F4 K2 LINE J13 J22 J57 TST RST J6 J43 S1 J7 J8 SEN. A SEN. B J9 J26 J43 F2 J60 J58 J12 J2 J6 U4 WHT AC Balboa U4 2 3 NEUTRAL VS100 P/N 22964_B MADE IN U.S.A. © 2006 1 K3 K2 W1 J13 T0.25A 250V J2A MADE IN U.S.A V VAC COPYRIGHT 2005 HEATER A J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. SWITCHBANK A J43 on VS100/GS100 Series Main Board Shown. Page 4 54371-02_97_A Wiring Configuration and DIP Settings Setup 1 (As Manufactured) s 6/ZONE s 63PA,IGHT s 6!<6(Stereo) s 6K7(EATER s 6,36,36,3-AIN0ANEL s 6#IRC0UMPOPTIONAL PCBA Rev D & E only. Black jumper required. Do not remove. NEUTRAL WHITE W3 C C G K5 W2 J1 J1A J10 HOT BLACK VS5xxS mode K3 K2 TB1 J32 J33 J34 J36 2 3 J12 J2 J35 J43 J37 F2 RED AC HTR2 J100 J13 HTR1 J101 5.5 kW J60 J22 EXT. RLY AUX. F J6 E.GND Balboa 1 U4 J18 J2A HOT RED K4 TORQUE RANGE FOR TB1: 27-30 IN. LBS. FUSE 3A 250V K8 K9 T1 F1 J20 G J46 C J17/26 C G W4 C G W7 W1 F4 FUSE .3A 250V J29 12V Light J73 J47 Ozone J16 J25 J63 J64 J15 Blower J66 J65 J11 Audio Visual 2-Spd P1 WHT T AC F7 FUSE 20A 250V W10 J50 J74 C J62 Circ.Pump J61 K1 K6 J23 BLK AC F5 G CLASS G FUSE 30A Ozone and Circ Pump must be same voltage. Do not remove Fuse F7 (20A) G s 60UMP3PEED s 60UMP3PEED s 6"LOWER S1 TST SWITCHBANK A J7 J8 SEN. A SEN. B BALBOA INSTRUMENTS, INC. 2-SPD J44 VS500Z EXT RLY P/N 22972 REV D VAC MADE IN U.S.A COPYRIGHT 2005 Heater rated @ 240V (Approx. 1.4kW @ 120V) K1 J6 B W R 1-Spd P2G J2 J4 W12 WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) VS51x/VS5xxS/VS5xxD Compatible SSID # 100 65 43 120 Volt Connections J12 240 Volt Connections 1 3 J43 Memory Reset Panel Button Positions 7 5 6 1 2 4 3 5 6 Black AC Jumpers Relay Control Wires A9, Non-Circ Mode A10, See Table 1 Panel Button Assignments 5=Pump 1 6=Unused 6=Pump 2 7=Unused 7=J17/26 2 12 Volt Connections A1, Test Mode OFF A2, See Table 1 A7, J17/26 Enabled Disabled disabled A3, Off-board Pump enabled A5, 2-speed P1 1=Mode 2=Temp Up 3=Temp Down 4=Light Wiring Color Key 1 2 4 7 3 5 6 Board Connector Key 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps 3 Neutral (Common) 4 Ground Note flat sides in connector 2 1 Page 5 54371-02_97_A DIP Switches and Jumpers Definitions SSID 100 65 43 Base Model VS500SZ-VS501SZ-VS510SZ DIP Switch Key A1 Test Mode (normally OFF) A2+A10 Control amp draw requirements (See Table 1) A3 “ON” position: off-board pump enabled * “OFF” position: off-board pump disabled A4 Aux Freeze (must be OFF) A5+A9 Pump 1 speeds and Circ Modes: Table 1 A5 A9 Circ Mode Pump 1 Speed OFF ON OFF ON OFF OFF ON ON Non-circ Circ "acts like Pump 1 low" (filters/polls/ect) 24 hours with 3°F shut-off 24 hours with 3°F shut-off 2-speed 1-speed 1-speed 2-speed A2 # of Hi-Speed Pumps/Blower Before Heat Disabled A10 OFF ON OFF ON OFF OFF ON ON 0 1 2 3 A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: J17/26 equipment enabled * “OFF” position: J17/26 equipment disabled A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit * Panel with button layout is not compatible when both A3 and A7 are ON. Jumper Key J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software. Jumper must be on Pins 2 and 3 for VS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: sSetting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system. sContact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions 7 5 6 1 2 4 3 Aux Panel Information 1 5 2 4 3 2 4 7 3 5 6 Supports 2-button aux panel VX20 5 6 1 6 Supports 4-button aux panel Panel Button Assignments 1=Mode 2=Temp Up 3=Temp Down 4=Light 5=Pump 1 A7: OFF VX40S 5 6 7 4 A7: ON 6=Unused 6=J17/26 A3: OFF 7=Unused 7=Unused 6=Pump 2 6=Pump 2 A3:ON 7=Unused 7=J17/26 Page 6 54371-02_97_A Ozone Connections Ozone Connector Voltage: The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the required voltage. WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage is selected. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone Ground (Green) conductor G Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B FUSE 20A 250V J46 Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone Ground (Green) conductor J47 J29 R Circ.Pump W W W G W3 W2 FUSE 3A 250V B J20 F1 12V Light K8 G K5 Line - Black conductor Use this slot for the leftover conductor Common - Red for 240V or White for 120V ozone (See W2 wire) Ground (Green) conductor W2 wire determines voltage J1 J1A J10 Page 7 54371-02_97_A Serial Standard Panel Configurations VL700S 1 with Overlay PN 11688 PN 53811 s Connects to Main Board terminal J1 only* Blower Warm Mode SETUP 1 Heat Jets 1 Jets 2 Cool Light VL701S (Serial Standard) PN 53189-01 with Overlay PN 10430 s Connects to Main Board terminal J1 only* Mode Blower Warm Heat Jets 1 Jets 2 Light Cool VL702S PN 54652 with Overlay PN 11790 s Connects to Main Board terminal J1 only* * Panels with back-lighting (bulbs installed) should never be plugged into J2. Use J1 only. If the backlight bulbs are removed, then both J1 and J2 may be used. Page 8 54371-02_97_A
© Copyright 2026 Paperzz