What`s new in AO 2.33?

What’s new in AO 2.33?
April 2014
Think Automation and beyond…
FT1A Approval Updates
NEMA Type 4X (Indoor Only), 13
– FT1A Touch
Class 1 Div. 2 Hazardous Locations
– FT1A series (Touch and Controllers)
Marine Approvals
– ABS, Lloyds Register, DNV, and NK
– FT1A series (Touch and Controllers)
Think Automation and beyond…
FT1A Touch – Additional Drivers
FT1A Touch now can communicate with other PLCs
Current Supported Drivers
–
–
IDEC PLCs (Serial/Ethernet)
Modbus RTU and TCP (Serial/Ethernet)
Benefits:
–
Additional NEW Drivers
–
–
Siemens S7-1200 (Ethernet)
Automation Direct
–
–
FX3U (Ethernet)
FX (Link)
Q/QnA (Ethernet)
Omron
–
DL205/405
Ethernet
Mitsubishi
CS1/CJ (Ethernet)
Others
Keyence
Yaskawa
Fuji
Hitachi
Yokogawa
More Drivers in the future
–
Allen Bradley
Think Automation and beyond…
–
–
FT1A Touch can communicate with internal
PLC and external PLCs (IDEC or others) at
the same time
We can promote the FT1A as Display only
if needed to
For applications require more I/O than
internal 12 I/O PLC, we can suggest using
external PLCs
FC5A-D12 Features Enhancement
Modbus Error Status
– Current Issues
User has option to designate data registers to monitor Modbus
TCP/RTU communication status
Problem is that the status register does not get update when
recovered from communication failure
The current spec is not useful since the error status remains in
“Error” status even though communication already recovered
User does not know when PLC communication recovered
User does not get alert (through email/text) on subsequent
communication failures
Communication Fails
Think Automation and beyond…
After Communication Recovered
FC5A-D12 Features Enhancement
Modbus Error Status
– Improved Specification
User has option to designate data registers to monitor Modbus
TCP/RTU communication status with or without Update
Data register will be reset to 0 when communication recovered
User now has the ability to detect when error occurs and when it’s
recovered
User has option to keep track on how many failures occur
Subsequent failures can now be detected and email or text alert
can be sent to users for notifications
Communication Fails
Think Automation and beyond…
After Communication Recovered
FC5A-D12 Features Enhancement
Remote Host List
– Current Specification and Issues
Remote Host List IP address can be configured using WindLDR software
This method requires users to know ahead of time which IP address to use
In some instances, OEM and machine builders don’t know or want to
provide end users the capability to configure this settings
Providing WindLDR software is not an option for OEM because end users
have access to the program
In some instances, users want to be able to configure on HMI
Think Automation and beyond…
FC5A-D12 Features Enhancement
Remote Host List
– Improved Specification
Remote Host List IP address can be configured using data registers
Four consecutive data registers will be occupied for one IP address
Remote Host IP address can now be updated via HMI or Web page
Think Automation and beyond…
FC5A-D12 Features Enhancement
Email Address (Recipients)
– Current Specification and Issues
Email address can be configured using WindLDR software
This method requires users to know email address of the recipient ahead of
time
In some instances, OEM and machine builders don’t know or want to provide
end users the capability to configure this settings
In some instances, users want to be able to configure on HMI
In some instances, users can’t delete and update existing email address if the
person is no longer with the company
Providing WindLDR software is not an option for OEM because end users have
access to the program
Think Automation and beyond…
FC5A-D12 Features Enhancement
Email Address (Recipients)
– Improved Specification
Email address can be configured using data registers
Thirty consecutive data registers will be occupied for one Email
address
Email address can now be updated via HMI or Web page
Think Automation and beyond…
FC5A-D12 Features Enhancement
Email Address (Sender)
– Improved Specification
Sender Email and Password can now be configured using data
registers
107 consecutive data registers will be occupied
Sender Email address and password can now be updated via
HMI or Web page
Think Automation and beyond…
FC5A-D12 Features Enhancement
Email Attachment
– Improved Specification
User now has option to attach a CSV file when an email get send
Max. 1536 bytes can be configured
Useful for logging data and keep track of production status
Think Automation and beyond…
FC5A-D12 Features Enhancement
Connect/Disconnect Client Connections
– Improved Specification
Special internal M8230, M8231 and M8232 can be used to
Disconnect or Connect Client Connections
Useful if user needs to refresh the connections
Think Automation and beyond…