What’s new in AO 2.33? April 2014 Think Automation and beyond… FT1A Approval Updates NEMA Type 4X (Indoor Only), 13 – FT1A Touch Class 1 Div. 2 Hazardous Locations – FT1A series (Touch and Controllers) Marine Approvals – ABS, Lloyds Register, DNV, and NK – FT1A series (Touch and Controllers) Think Automation and beyond… FT1A Touch – Additional Drivers FT1A Touch now can communicate with other PLCs Current Supported Drivers – – IDEC PLCs (Serial/Ethernet) Modbus RTU and TCP (Serial/Ethernet) Benefits: – Additional NEW Drivers – – Siemens S7-1200 (Ethernet) Automation Direct – – FX3U (Ethernet) FX (Link) Q/QnA (Ethernet) Omron – DL205/405 Ethernet Mitsubishi CS1/CJ (Ethernet) Others Keyence Yaskawa Fuji Hitachi Yokogawa More Drivers in the future – Allen Bradley Think Automation and beyond… – – FT1A Touch can communicate with internal PLC and external PLCs (IDEC or others) at the same time We can promote the FT1A as Display only if needed to For applications require more I/O than internal 12 I/O PLC, we can suggest using external PLCs FC5A-D12 Features Enhancement Modbus Error Status – Current Issues User has option to designate data registers to monitor Modbus TCP/RTU communication status Problem is that the status register does not get update when recovered from communication failure The current spec is not useful since the error status remains in “Error” status even though communication already recovered User does not know when PLC communication recovered User does not get alert (through email/text) on subsequent communication failures Communication Fails Think Automation and beyond… After Communication Recovered FC5A-D12 Features Enhancement Modbus Error Status – Improved Specification User has option to designate data registers to monitor Modbus TCP/RTU communication status with or without Update Data register will be reset to 0 when communication recovered User now has the ability to detect when error occurs and when it’s recovered User has option to keep track on how many failures occur Subsequent failures can now be detected and email or text alert can be sent to users for notifications Communication Fails Think Automation and beyond… After Communication Recovered FC5A-D12 Features Enhancement Remote Host List – Current Specification and Issues Remote Host List IP address can be configured using WindLDR software This method requires users to know ahead of time which IP address to use In some instances, OEM and machine builders don’t know or want to provide end users the capability to configure this settings Providing WindLDR software is not an option for OEM because end users have access to the program In some instances, users want to be able to configure on HMI Think Automation and beyond… FC5A-D12 Features Enhancement Remote Host List – Improved Specification Remote Host List IP address can be configured using data registers Four consecutive data registers will be occupied for one IP address Remote Host IP address can now be updated via HMI or Web page Think Automation and beyond… FC5A-D12 Features Enhancement Email Address (Recipients) – Current Specification and Issues Email address can be configured using WindLDR software This method requires users to know email address of the recipient ahead of time In some instances, OEM and machine builders don’t know or want to provide end users the capability to configure this settings In some instances, users want to be able to configure on HMI In some instances, users can’t delete and update existing email address if the person is no longer with the company Providing WindLDR software is not an option for OEM because end users have access to the program Think Automation and beyond… FC5A-D12 Features Enhancement Email Address (Recipients) – Improved Specification Email address can be configured using data registers Thirty consecutive data registers will be occupied for one Email address Email address can now be updated via HMI or Web page Think Automation and beyond… FC5A-D12 Features Enhancement Email Address (Sender) – Improved Specification Sender Email and Password can now be configured using data registers 107 consecutive data registers will be occupied Sender Email address and password can now be updated via HMI or Web page Think Automation and beyond… FC5A-D12 Features Enhancement Email Attachment – Improved Specification User now has option to attach a CSV file when an email get send Max. 1536 bytes can be configured Useful for logging data and keep track of production status Think Automation and beyond… FC5A-D12 Features Enhancement Connect/Disconnect Client Connections – Improved Specification Special internal M8230, M8231 and M8232 can be used to Disconnect or Connect Client Connections Useful if user needs to refresh the connections Think Automation and beyond…
© Copyright 2026 Paperzz