Electronic Pressure Measurement Air Flow Transmitter Type A2G-25 WIKA Datasheet A2G-25 Applications ■■ Measuring the volume flow in ventilation ducts for air and non-combustible gases ■■ Used for fans and ventilators of various manufacturers ■■ Monitoring of air volume flow or pressure directly on the air handling unit ■■ For use with fans/blowers from various manufacturers Special Features Easy installation User-friendly display Easy-to-read LCD display Temperature compensated ■■ Output signals for differential pressure and air volume flow ■■ Air flow calculation based on k factor Air Flow Transmitter model A2G-25 Description Version In accordance with the CE requirements of EMC Directive 89/336/EEC, ROHS Directive 2002/95/EY Accuracy At 4 InWC and 8 InWC ± 0.02 InWC: ±1.5 % of display At 20 InWC and 28 InWC : ±0.03 InWC: ±1.5 % of display Display ranges 0 ... 4 InWC, 0 ... 8 InWC, 0 ... 20 InWC or 0 ... 28 InWC Selectable units on the display: LPM, m3/s, m3/h, cfm, l/s, scfh, mbar, mmWC, kPa or Pa Long-term stability At 4 InWC and 8 InWC: ±0.03 InWC At 20 InWC and 28 InWC: ±0.1 InWC Manual zero adjustment (standard) Automatic zero adjustment (optional): ±0.03 InWC WIKA Datasheet A2G-25 · 3/2013 Maximum working pressure 100 InWC Operating temperature Ambient: -4...+160°F Medium: 23 … +122 °F Permissible ambient humidity 0 ... 95 % rH, non-condensing Ingress protection NEMA 3 (IP54 per EN 60529 / IEC 529) Weight 5.2 ounces (150 grams ) Page 1 of 4 R Standard features Process connection Hose barb (ABS) Measuring element Piezo sensor Display Alphanumeric display with menu-driven user interface Case Plastic (ABS) Electrical connection M16 PG-Gland Output signal V OUT DC 0 … 10 V, Load R minimum 1 kΩ linear to adjusted output unit, P OUT DC 0 … 10 V, Load R minimum 1 kΩ linear to adjusted output unit Supply voltage AC 24 V or DC 24 V ±10 % Zero point adjustment On the display keyboard Standard accessories 2 mounting screWC 2 plastic duct connectors 3 feet PVC hose, inner diameter 1/8” / 3/16” Options ■■ Automatic zero adjustment (Long-term stability ±1 Pa) Wiring diagram V-scale output can be changed (in relation to the selected output unit) Page 2 of 4 WIKA Datasheet A2G-25 · 3/2013 40376281X.01 Connection diagram Zero point adjustment Manual zero adjustment (standard) 1. Both the + and the – flow inputs must be disconnected. 2. Press the zero point button until the red LED lights up. 3. Wait until the LED switches off again. Now the instrument can be reconnected. 4. In normal operation, we recommend that a zero adjustment is carried out every 12 months. ZERO Automatic zero adjustment (option) The automatic zero adjustment adjusts the zero point from time to time so that a manual zero adjustment is not necessary. During the zero adjustment (3 seconds every 10 minutes), the output signal and the display show the last measured value. Dimensions in inches 1.69 2.05 2.76 0.15 3.36 40376281.01 2.65 0.47 0.39 0.59 WIKA Datasheet A2G-25 · 3/2013 0.75 0.91 Page 3 of 4 Menu selections and initialization instructions for installation If buttons are not pressed within 20 seconds the device returns to the normal measuring mode. 1. Press the Select button for at least 2 seconds to enter the menu. 2. Select the fan manufacturer. 3. Each fan manufacturer has its own specific K-value. Please take the correct K-value from the data sheet: Fläkt Woods (k = 0,3 … 99) Rosenberg (k = 37 … 800) Nicotra (c = 10 … 1500) Comefri (k = 10 … 2000) Ziehl (k = 10 … 1500) Ebm-Papst (k = 10 … 1500) Gebhard (k = 50 … 4700) 4. The following units will be displayed: m3/s, m3/h, cfm, l/s, scfh, lpm, kPa, mbar, mmWC, inchWC or Pa. 5. Pressure output unit (and P OUT scale) At 1,000 Pa 0 ... 1,000 Pa 0 ... 1 kPa 0 ... 10 mbar 0 ... 100 mmWC 0 ... 4 inchWC At 2,000 Pa 0 ... 2000 Pa 0 ... 2 kPa 0 ... 20 mbar 0 ... 200 mmWC 0 ... 8 inchWC At 5,000 Pa 0 ... 5000 Pa 0 ... 5 kPa 0 ... 50 mbar 0 ... 500 mmWC 0 ... 20 inchWC The maximum value corresponds to an output signal of 10 V 6. At 7,000 Pa 0 ... 7,000 Pa 0 ... 7 kPa 0 ... 70 mbar 0 ... 700 mmWC 0 ... 28 inchWC Flow output unit for defining the V OUT scale 7. V OUT scale, selectable: m3/s → 10 V = 1 … 50 m3/s m3/h → 10 V = 4000 … 200000 m3/h cfm → 10 V = 2000 … 100000 cfm l/s → 10 V = 1000 … 50000 l/s scfh → 10 V = 1000000 …6000000 scfh lpm → 10 V = 60000 … 3000000 lpm 8. Stepless response time selection. 9. Press the END button and the instrument returns to the normal measuring mode. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 4 of 4 © Copyright 2013 WIKA Instrument, LP. All Rights Reserved. WIKA Datasheet A2G-25 · 3/2013 R WIKA Instrument, LP 1000 Wiegand Boulevard Lawrenceville, GA 30043-5868 Tel: 888-WIKA-USA • 770-513-8200 Fax:770-338-5118 E-Mail:[email protected] www.wika.com
© Copyright 2026 Paperzz