® Photocontroller and Photocells ♦ Control module and photocells for daylighting control of interior and exterior lighting ♦ Four photocell types for specific application settings ♦ Adjustable setpoints for deadband ♦ Three-minute time delay ♦ Three isolated outputs ♦ Master switch input ♦ Photocell lockout ♦ One year warranty Component Information The Watt Stopper’s basic photocontroller works with a range of photocells to add daylighting control capability to lighting control panels. The controller and photocells are compatible with Smartwired Control and Complete Control panels. In addition to the controller module itself (HPCU), there are four different photocells. Each photocell is designed for different applications, and the user may select the appropriate photocell. Operation The photocontroller utilizes a photocell sensor (located either outdoors or indoors, depending on the application) to read light levels and transmit the data to the controller module, usually located in the lighting control panel. When the light level data received from the photocell indicates that the setpoint has been reached for a sufficient time, the controller will switch lighting OFF. Conversely, when light level data from the photocell indicates that the daylight contribution is not adequate, the controller will switch lighting ON. With the appropriate photocell, the controller provides daylighting control for interior spaces, atriums, skylights, and exterior lighting. Features A Class 2 device, the photocontroller has three outputs that may be connected directly to relays or to a programmable input or channel. The module features a three-minute time delay and adjustable switching ranges that allow adjustment for high and low setpoints of the deadband. Applications Users may select among four different photocells to tailor the control to the application more precisely. The HPCSIN photocell provides monitoring of daylight contributions in interior spaces. The HPCSOT photocell is designed for exterior use and the control of exterior lighting. For atrium spaces, users would select the HPCSAT photocell, which is capable of sensing the brightness of ceiling spaces without being exposed to direct daylight. In applications that include skylights, the HPCSKY photocell would be the suitable choice, as it is designed for mounting in the skylight itself and is capable of monitoring daylight levels between 1,000-10,000 footcandles. By providing a selection of photocells that work with the Photocontroller, users are able to take advantage of energy savings through using the abundance of daylight. Photocontroller Technical Information Specifications Ordering Information ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ Compatible with The Watt Stopper Smartwired Control and Complete Control panels User-selectable footcandle range from 0 - 10,000 for controller module (HPCU) Three isolated outputs each capable of driving up to three relays or an intelligent input Controller module mounts in any Watt Stopper interior or accessory enclosure Choice of four photocell sensors: interior, exterior, atrium, or skylight sensor User-adjustable deadband of two footcandles Three-minute time delay Master switch input for temporarily overriding all outputs Lockout switch for disabling sensor during unoccupied periods One year warranty Catalog No. Description Footcandle Range HPCU Photocontroller HPCSIN Indoor Photocell HPCSOT Outdoor Photocell HPCSAT Atrium Photocell 100-1000 HPCSKY Skylight Photocell 1000-10,000 Unit Layout 10-100 1-10 (parking lot and security lighting) 1 24VAC DELAY ENABLE OFF 2 Layout of Photocontroller Unit COM RED ON BLACK RANGE SELECTOR 3 6 7 Photocell sensor input terminals Delay enable switch (ON=enable) 3 Range selector switch (1-10/10-100/100-1000/1000-10,000 FC) 8 Master switch input terminals 4 High level adjustment & LED 9 Relay output terminals (3 sets) 5 Low level adjustment & LED 1 2 RED 9 BLACK RED 4 4 3 2 1 5 6 7 BLACK 8 9 10 MASTER SWITCH HIGH 4 5 6 7 3 2 1 5 8 9 10 ON-RED LOW 24 VAC power supply terminals Photocell sensor enable switch input terminals 8 OFF-BLK COMMON PHOTOCELL BLACK WHITE RED BLUE SENSOR ENABLE DRAIN 6 Wiring & Installation ON COM 7 Photocontroller - HPCSIN Photocell Wiring Photocontroller Wiring Diagram 24 VAC power supply 24VAC COM DELAY ENABLE OFF 0.375" diameter through hole RED ON BLACK RANGE SELECTOR Ceiling RED BLACK LINE RED RED 5 6 7 MASTER SWITCH ON-RED ON-RED COM COMMON RED WHITE RED BLUE DRAIN SENSOR ENABLE ON COM RANGE SELECTOR OR … OFF-BLK BLACK Photocell ON MASTER SWITCH BLACK LOW PHOTOCELL Photocontroller 24VAC 8 9 10 DELAY ENABLE 5 6 7 Relay (typical of three) BLACK 8 9 10 HIGH 4 3 2 1 1 OFF 4 3 2 1 BLACK YELLOW WHITE LOAD OFF-BLK RED BLACK COMMON SPST maint. master switch SPDT mom. master switch RED 4 3 2 1 5 6 7 BLACK 8 9 10 MASTER SWITCH HIGH 4 3 2 1 5 6 7 8 9 10 ON-RED LOW OFF-BLK COMMON To photocell sensor Optional Shield PHOTOCELL Photocontroller - HPCSOT Photocell Wiring Photocell BLACK WHITE RED Weathertight Junction Box Photocell Photocontroller 24VAC COM DELAY ENABLE OFF Photocontroller RED ON 24VAC 5 6 7 5 6 7 RED BLACK BLACK 8 9 10 RED MASTER SWITCH HIGH 4 3 2 1 RED BLACK RANGE SELECTOR 4 3 2 1 ON RED DELAY ENABLE RANGE SELECTOR RED BLACK COM OFF BLACK 8 9 10 ON-RED 4 3 2 1 5 6 7 BLACK 8 9 10 MASTER SWITCH HIGH LOW OFF-BLK COMMON 4 3 2 1 5 6 7 8 9 10 ON-RED LOW OFF-BLK COMMON Pub. No. 13601 DRAIN SENSOR ENABLE ON COM Photocontroller - HPCSAT Photocell Wiring 0.5" Threaded Inlet The Watt Stopper®, Inc. BLUE SPST maintained switch (optional) PHOTOCELL BLACK WHITE RED BLUE DRAIN SENSOR ENABLE ON COM PHOTOCELL BLACK WHITE RED BLUE DRAIN SENSOR ENABLE ON COM
© Copyright 2026 Paperzz