9986371 Manualforside BW800:1 18-05-2009 12:48 Side 1 BRIDGE WATCH ALARM SYSTEM BW-800 NE W! Bridge Watch BW-800 ALARM STAGE min. SELECT MODE BRIDGE ALARM 1 BRIDGE ALARM 2 MANUAL - AUTO set + CAPTAIN’S ALARM STAFF ALARM Bridge Watch ACTIVE Bridge Watch STANDBY RESET ON Bridge Watch MALFUNCTION TIMER and BRIDGE WATCH MODE can be operated within 30 sec. after key is switched to ON OFF Uni-Safe Electronics A/S Emergency call: press 2 sec. (to cancel call: press 2 sec. again) www.unielec.dk New regulations from IMO’s Maritime Safety Committee (MSC) will require carriage of a Bridge Navigational Watch Alarm System (BNWAS) complying with IMO performance standards. For existing ships, the equipment should be installed in connection with the first survey after the following deadlines: Existing passenger ships and ships over 3,000 GT: 1 July 2012. Existing ships over 500 GT: 1 July 2013. Existing ships over 150 GT: 1 July 2014. New ships over 150 GT and all new passenger ships constructed after 1 July 2011 shall be equipped with a Bridge Navigational Watch Alarm System. Competitive prices User-friendly, small and easy to install Automatic dimmer control Emergency call facility Timer display Motion sensor with infrared and microwave detection Visual alarm: Reset unit is flashing Output for motion sensor secured against short circuit Alarm signal increases in volume Y Produced and developed in Denmark 9986371 Manualforside BW800:1 18-05-2009 12:48 Side 2 Specifications BW-800 Complies with following standards: IMO A.694(17) IMO A.830(19) IMO MSC. 128(75) IEC 62616 IEC 60945 IEC 62288 IEC 61162 Dimension: BW-801 reset unit: Front: 50 mm x 50 mm Mains supply: 24 Vdc BW-802 alarm unit: Front: 50 mm x 77 mm Mains power: Mains supply must be secured against overcurrent with an external fuse. Max. 500 mA Display: 2 LED displays (2 digits) Timer interval: 3-12 min. Relay contacts: Max. 10 A / 24 Vdc. Relay contacts must be secured against overcurrent with external fuses Battery backup: Battery backup supply must be secured against overcurrent with an external fuse. Max. 500 mA. Battery backup must be able to supply BW-800 for a period of 6 hours (min. 3 Ah battery backup) Protection: IP 65 BW-800: Front: 160 mm x 100 mm Cut out: 140 mm x 95 mm Depth: 50 mm The purpose of a bridge navigational watch alarm system (BNWAS) is to monitor bridge activity and detect operator disability which could lead to marine accidents. The system monitors the awareness of the Officer of the Watch (OOW) and automatically alerts the Captain or another qualified OOW if for any reason the OOW becomes incapable of performing the OOW's duties. This purpose is achieved by a series of indications and alarms to alert first the OOW and, if he is not responding, then to alert the Captain or another qualified OOW. Additionally, the BNWAS may provide the OOW with a means of calling for immediate assistance if required. The BNWAS should be operational whenever the ship's heading or track control system is engaged, unless inhibited by the Captain. Activity input from other equipment: Radar, ECDIS, VHF.... Malfunction output to central alarm panel if fitted Bridge Watch BW-800 ALARM STAGE min. SELECT MODE BRIDGE ALARM 1 BRIDGE ALARM 2 MANUAL - AUTO set + CAPTAIN’S ALARM STAFF ALARM Input from ships heading or track control system Main power 24 Vdc Bridge Watch ACTIVE RESET ON Bridge Watch STANDBY Bridge Watch MALFUNCTION TIMER and BRIDGE WATCH MODE can be operated within 30 sec. after key is switched to ON VDR interface output OFF Uni-Safe Electronics A/S Emergency call: press 2 sec. (to cancel call: press 2 sec. again) Battery backup power 24 Vdc www.unielec.dk BW-802 BW-801 BW-802 BW-802 Bridge Watch Bridge Watch Bridge Watch ASSISTANCE TO BRIDGE NEEDED ASSISTANCE TO BRIDGE NEEDED ASSISTANCE TO BRIDGE NEEDED Bridge Watch RESET Press button to reset Emergency call: press 2 sec. (to cancel call: press 2 sec. again) Uni-Safe Electronics A/S Motion Sensor Uni-Safe Electronics A/S www.unielec.dk Reset unit with visual alarm TE www.unielec.dk Alarm 1: Bridge Activated 15 sec.after visual alarm Uni-Safe Electronics A/S www.unielec.dk Alarm 2: Captain´s quarters Activated 15 sec. after alarm 1 Uni-Safe Electronics A/S www.unielec.dk Alarm 3: Crew area Activated 60-180 sec. after alarm 2 Visit us ! - www.bnwasturkey.com TEL : +90 216 425 77 00 FAX : +90 216 425 77 88 www.yddo.com.tr www.unielec.dk BRIDGE WATCH MODE
© Copyright 2026 Paperzz