reaction to fire classification report

Project Nº
PY12-0745
Document Nº
233230
Page 1 / 5
REACTION TO FIRE CLASSIFICATION REPORT
Applicant:
Address::
Ref. Lab.:
ARTESANÍAS JIMAN, S.L. (PANELPIEDRA-PANELSTONE)
CTRA. ZARAGOZA KM 354 01320 ALFARO (LA RIOJA)
MV61929
REACTION TO FIRE CLASSIFICATION
REPORT
ACORDING TO EN 13501-1:2010.
PANEL PIEDRA REF-HD
The reproduction of this classification report is only authorized in its integral form
Project Nº
PY12-0745
Document Nº
233230
Page 2 / 5
1. SUMMARY
Applicant:
ARTESANIAS JIMAN, S.L.
(PANELPIEDRA-PANELSTONE)
CARRETERA ZARAGOZA KM 334
26540 ALFARO (LA RIOJA)
Product:
Decorative panels HD
Manufacturer:
ARTESANIAS JIMAN, S.L.
Commercial
brand*
PANEL PIEDRA RF-HD
Specifications *
Decorative panels of aggregates sulfates and
carbonates with polyester resin
Date of test
December 17-21, 2012
December 26, 2012
(*)Data provided by the Applicant
Organismo
CLASSIFICATION:
Notificado Nº 1668
EN 13501-1:2007+
A1:2010.FIRE
CLASSIFICATION OF
CONSTRUCTION
PRODUCTS AND
BUILDING ELEMENTS PART 1: CLASSIFICATION
USING DATA FROM
REACTION TO FIRE
TESTS
REACTION TO FIRE REPORT
CLASSIFICATION
B-s1, d0
Navarrete, 29th of january 2013
Digitally signed by NOMBRE
MALAINA BENGOA ELENA NIF 16595718E
DN: c=ES, o=FNMT, ou=FNMT
Clase 2 CA, ou=500790026,
cn=NOMBRE MALAINA
BENGOA ELENA - NIF
16595718E
Date: 2013.01.29 13:53:21
+01'00'
Elena Malaina Bengoa
Head of Fire Laboratory
Project Nº
PY12-0745
Document Nº
233230
Page 3 / 5
2. PURPOSE OF THE REPORT
The purpose of this report is the classification of the reaction to fire of a product that in its
application for final use, can contribute to the generation and spread of fire and smoke within
the room of origin or in a given area.
The classification is in accordance with the standard EN 13501-1: 2007 + A1:2010:
Fire classification of construction products and building elements. Part 1: Classification using
test data from reaction to fire tests.
NOTE: This report does not represent any type of approval or certificate of the
product tested.
3. PRODUCT DESCRIPTION
Definition: Decorative panels arid sulfates and carbonates with polyester resin
Manufacturer: ARTESANÍAS JIMAN, S.L.
Model: PANEL PIEDRA RF-HD
Composition:
Sulfates, carbonates and aggregates with polyester resin
Thickness:
30-40 mm
Color:
Brown
Finish:
Matte
Appearance:
Rough, Irregular
Orientability:
No
Project Nº
PY12-0745
Document Nº
233230
Page 4 / 5
4. TEST REPORTS IN SUPPORT OF THIS CLASSIFICATION.
Issuing Laboratory
Applicant
ENSATEC
P.I. Lentiscares, Avda. Lentiscares 4-6
26370 Navarrete (LA RIOJA)
ARTESANIAS JIMAN, S.L.
(PANELPIEDRA-PANELSTONE)
CARRETERA ZARAGOZA KM 334
26540 ALFARO (LA RIOJA)
Product:
Decorative panels HD
Model:
PANEL PIEDRA RF-HD
Test method:
EN 13823:2012.: Reaction to fire tests for building products –
Building products excluding floorings exposed to the thermal
attack by a single burning item
Test Report nº::
Date of test:
232852
17/12/2012, 20/12/2012, 21/12/2012
Issuing Laboratory
Applicant
ENSATEC
P.I. Lentiscares, Avda. Lentiscares 4-6
26370 Navarrete (LA RIOJA)
ARTESANIAS JIMAN, S.L.
(PANELPIEDRA-PANELSTONE)
CARRETERA ZARAGOZA KM 334
26540 ALFARO (LA RIOJA)
Product:
Decorative panels HD
Model:
PANEL PIEDRA RF-HD
Test method:
EN ISO 11925-2:2011. Reaction to fire tests - Ignitability of
products subjected to direct impingement of flame - Part 2:
Single-flame source test (ISO 11925-2:2010)
Test Report nº::
Date of test:
232853
26 /12/ 2012
Project Nº
PY12-0745
Document Nº
233230
Page 5 / 5
TEST RESULTS IN SUPPORT OF THIS CLASSIFICATION:
FLAME CONTROL GAMA PUR TRANSPARENTE, HIGH GLOSS TRANSPARENT
COATING
Test method: EN ISO 11925-2:2011
Parameter
Number of tests
Test Results
Continuous
Compliance
parameter
parameter
(mean)
Fs ≤ 150 mm
--
YES
--
YES
6
Ignition of filter
paper
Test report nº
232853
FLAME CONTROL GAMA PUR TRANSPARENTE, HIGH GLOSS TRANSPARENT
COATING
Test method: EN 13823:2012
Parameter
Number of
tests
Test Results
Continuous
Compliance
parameter
parameter)
(mean)
THR600s:
4.44
FIGRA0,2MJ:
56.58
FIGRA0,4MJ:
56.58
TSP600s:
3
43.55
Test report nº
-----
232852
--
SMOGRA:
12.86
LFS
--
YES
Drops/Particles on
flames:
--
YES
5. TEST VALIDITY
The validity of the report is suitable for up to five years from the date of completion of
the tests in which the classification is based.