ISO9001:2000 Ultrasonic Transmitter Transducers & Accessories www.ktekcorp.com PED K10C General Purpose 3.2 in 80 mm ML* 4.3 in 110 mm W 3.2 in 80 mm Maximum Measuring Length (ML) 33 ft / 10 m Typical Beam Width (W) 2.33 ft / .71 m K10FC Solids Applications nd=2 =explorer.exe,3 r] nd=ToggleDesktop 3.2 in 80 mm ML* 4.7 in 119 mm W Maximum Measuring Length (ML) 33 ft / 10 m Typical Beam Width (W) 2.33 ft / .71 m 3.2 in 80 mm * Consult Transducer Description & Range Details for Liquids & Solids Application Details. Proper Transmitter Selection May Also Improve Transducer Rangeability. K20C Intermediate Range 3.2 in 80 mm 6.7 in 170 mm ML* 12.2 in 310 mm W 3.2 in 80 mm Maximum Measuring Length (ML) 99 ft / 30 m Typical Beam Width (W) 15.75 ft / 4.8 m K20HC Intermediate Range with Dust 3.2 in 80 mm 6.7 in 170 mm ML* 12.2 in 310 mm W Maximum Measuring Length (ML) 99 ft / 30 m Typical Beam Width (W) 15.75 ft / 4.8 m 6.9 in 174 mm * Consult Transducer Description & Range Details for Liquids & Solids Application Details. Proper Transmitter Selection May Also Improve Transducer Rangeability. K60C Long Range 3.2 in 80 mm 12.2 in 310 mm ML* 12.2 in 310 mm W Maximum Measuring Length (ML) 197 ft / 60 m Typical Beam Width (W) 14.8 ft / 4.5 m 6.9 in 174 mm K10T3C PTFE Lined Transducer, 3 inch Flange K10T4C PTFE Lined Transducer, 4 inch Flange 3.2 in 80 mm 3.7 in 95 mm ML* 0.6 in 15 mm W 3 in. Maximum Measuring Length (ML) 33 ft / 10 m Typical Beam Width (W) 2.33 ft / .71 m 4 in. 7.5 in 150 mm 9.1 in 230 mm * Consult Transducer Description & Range Details for Liquids & Solids Application Details. Proper Transmitter Selection May Also Improve Transducer Rangeability. 45° Cut Nozzle Nozzle or 90° Cut L D (in. / mm) 3 in. 80 mm 4 in. 100 mm 6 in. 150 mm 8 in. 200 mm 10 in. 250 mm L D D 45° CUT NOZZLE Maximum Length (L) K10 K20 K60 19 in. not not 490 mm applicable applicable 22 in. 30 in. not 550 mm 750 mm applicable 60 in 76 in. not 1500 mm 1900 mm applicable 80 in. 100 in. consult 2000 mm 2500 mm factory 100 in. 124 in. consult 2500 mm 3100 mm factory D (in. / mm) 3 in. 80 mm 4 in. 100 mm 6 in. 150 mm 8 in. 200 mm 10 in. 250 mm NOZZLE OR 90° CUT Maximum Length (L) K10 K20 K60 8 in. not not 200 mm applicable applicable 10 in. 26 in. not 250 mm 650 mm applicable 15 in. 60 in. not 380 mm 1500 mm applicable 15 in. 72 in. consult 380 mm 1800 mm factory 24 in. 92 in. consult 600 mm 2300 mm factory Nozzle Installation:The KSONIK Transducer must be installed at a height so that the blanking distance is not interfered with, even at the maximum fill level. A pipe nozzle can be used if you cannot obtain the blanking distance in any other way or if a nozzle is pre-existing on a tank structure. The interior of the nozzle must be smooth with no edges, welded joints or burrs on the inside of the tank side nozzle end. Best results are achieved with a 45°cut nozzle. The Transducer may not function correctly if the blanking distance is not above the maximum level measured. Trans K10C K10T3C K10T4C K10FC K20C K20HC K60C Min Bkg 1 ft. 0.3 m 1 ft. 0.3 m 1 ft. 0.3 m 1 ft. 0.3 m 3 ft. 1m 3 ft. 1m 5 ft. 1.5 m Transducer Material & Ratings Body IP Facing Material Material Protection Frq. KHz Beam Angle 44 11° Polyurethane PVC IP68 44 11° PTFE PVC IP68 44 11° PTFE PVC IP68 44 11° Polyurethane Foam PVC IP68 15.4 9° Polyurethane Foam PVC IP62 15.4 9° Polyurethane Foam PVC IP62 12.5 8° Polyurethane Foam PVC IP62 Trans Description K10C General Purpose K10T3C PTFE Transducer with flange K10T4C PTFE Transducer with flange K10FC Solid Applications K20C Medium Range K20HC Medium Range with Dust K60C Long Range Transducer Description & Ranges KSONIK I KSONIK II Liquids Solids Liquids Solids 33 ft. 16 ft. 49 ft. 16 ft. 10 m 5m 15 m 5m 33 ft. 16 ft. 49 ft. 16 ft. 10 m 5m 15 m 5m 33 ft. 16 ft. 49 ft. 16 ft. 10 m 5m 15 m 5m 33 ft. 49 ft. 49 ft. 10 m 15 m 15 m 99 ft. 99 ft. 30 m 30 m 99 ft. 99 ft. 30 m 30 m Temp Range -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C -4 to 176°F -20 to 80°C KSONIK III Liquids Solids 49 ft. 16 ft. 15 m 5m 49 ft. 16 ft. 15 m 5m 49 ft. 16 ft. 15 m 5m 49 ft. 49 ft. 15 m 15 m 99 ft. 99 ft. 30 m 30 m 99 ft. 99 ft. 30 m 30 m 197 ft. 197 ft. 60 m 60 m Mounting 1 in. MNPT 3” Flange 4” Flange 1 in. MNPT 1 in. MNPT 1 in. MNPT 1 in. MNPT KSONIK FLOW Liquids Solids 33 ft. 10 m 33 ft. 10 m 33 ft. 10 m NOTE: All transducers are temperature compensated. AKIT - Aiming Kit (304SS) It is recommended that an aiming kit be used when the transducer is used on a solids application. It allows positioning of the transducer to maximize the return signal. KSCOPE - KSONIK Scope Software Multi-use Windows based software package. Allows programming and bin mapping. Can also help set up a KSONIK I, II, or III in just a few minutes. EXT-CABxxx-Transducer Cable All KSONIK Transducers are supplied with 16ft (5m) cable lengths. Transducer cable length is available up to 820 ft (250m). If customer requirement is greater than 16ft (5m) standard length, then specify total cable length in feet (xxx). 3.2 in / 80 mm 7.4 in / 189 mm K-TEK 18321 Swamp Road Prairieville, Louisiana 70769 USA Telephone: (1) 225-673-6100 Fax: (1) 225-673-2525 KSTR-0202-1 Rev B (10-2003) Email: [email protected] Website: www.ktekcorp.com
© Copyright 2025 Paperzz