green power 2.0 and Delphys BC Modbus - TCP / Jbus serial link Installation and operating manual GB Index 1.Foreword 4 2. Safety Requirement 4 2. 1. Using conditions 2. 2.DELPHYS Green Power Operating Reference 3.Environment 3. 1.Recycling of electrical products and equipment 4.Introduction 4 4 4 5 4. 1.General purpose 5 4. 2.Modbus protocol 5 4. 3.Data decoding 5 5.Installation OF modbus rtu card 5. 1. ‘Com-Slots’ localisation 6 6 5. 2.Modbus serial interface plug in 6 5. 3.Modbus interface in parallel system configuration 6 5. 4.Connections and wiring 7 5. 5.Com2 Serial link default settings 8 5. 6. 8 How to change the “serial link 2” settings ? 6. installation of MODBUS TCP CARD 9 6. 1. ‘Com-Slots’ localisation 9 6. 2. UPS Com2 Modbus Serial link default settings 9 6. 3. default settings of the modbus tcp interface 7.Conventions 7. 1.Frame errors management 8.Modbus in Single UPS unit 8. 1. How to read data 10 11 11 12 12 8. 2.Incoming data structure 12 8. 3. 13 Ups Identification 8. 4.Date & Hours 13 8. 5. Ups Configuration 13 8. 6. Unit Status 14 8. 7. Unit Alarms 16 8. 8. Unit Measurements tables 18 8. 9. Unit Enabled Controls Table 20 8. 10.Controls Send To Ups 2 4 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 20 21 9. 1.Reminder 21 9. 2.Modbus table in modular parallel system 22 9. 3. 22 Ups Identification 9. 4.Date & Hours 22 9. 5. Ups Configuration 22 9. 6. Preliminary Remarks 22 9. 7. Ups Status 23 9. 8. Ups Alarms 24 9. 9. Ups Measurements 25 9. 10. Ups Enabled Controls Table 26 9. 11.To Send Control To Ups 26 10.MODBUS IN PARALLEL SYSTEM with centralised bypass 27 10. 1.Reminder 27 10. 2.Modbus table in parallel system with centralised bypass 28 10. 3. Ups Identification 28 10. 4.Date & Hours 28 10. 5. Ups Configuration 28 10. 6. Preliminary Remarks 28 10. 7. Ups Status 29 10. 8. Ups Alarms 30 10. 9. Ups Measurements 31 10. 10. Ups Enabled Controls Table 32 10. 11.To Send Control To Ups 32 11. Bypass TABLE 33 11. 1.Bypass Status 33 11. 2.Bypass Alarms 35 11. 3.Bypass Measurements tables 37 12.Module TABLE 39 12. 1.Module Status 39 12. 2.Module Alarms 41 12. 3.Module Measurements tables 43 13.ANNEXE 45 13. 1. 45 setting of the interface using digi® device discovery 13. 2.MODBUS TCP IDA specification ENGLISH 9.MODBUS IN modular PARALLEL SYSTEM CONFIGURATION 47 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 3 1. Foreword We thank you for the trust you have in our Uninterruptible Power Systems. This equipment is fitted with up to date technology. Rectifier and inverter subsets are provided with power semiconductors (IGBT) including a digital micro-controller. Our equipment complies with IEC EN 62040-2 standard. CAUTION : “This is a product for restricted sales distribution to informed partners. Installation restrictions or additional measures may be needed to prevent disturbances”. SOCOMEC UPS reserves the right to modify their specifications at any time as far as this contributes to technical progress. 2. Safety Requirement 2. 1. Using conditions Do read carefully these operation instructions before using the JBUS/MODBUS interface. Whatever the repairs, they must be made only by authorised staffs, which have been suitably trained. For an optimal operation, it is recommended to maintain the ambient temperature and humidity of the DELPHYS Green Power environment below the values specified by the manufacturer. 2. 2. DELPHYS Green Power Operating Reference Respect the safety requirements. Do read carefully the operation instructions of DELPHYS Green Power. This equipment meets the requirements of the European directives applied to this product. As a consequence it is labelled as follows: 3. Environment 3. 1. Recycling of electrical products and equipment Provision is made in European countries to break up and recycle materials making up the system. The various components must be disposed of in accordance with the legal provisions in force in the country where the system is installed. 4 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 4. Introduction 4. 1. General purpose This document provides required information of the MODBUS protocol serial link or Ethernet network. Before connecting a supervision equipment or BMS system (Building management system) to the UPS, it is neces- ENGLISH sary to install and set up the serial interface or network configurations in the case of a network connection.. 4. 2. Modbus protocol This document does not explain the MODBUS protocol management. Please refer on www.modbus.org web site for more information. The DELPHYS Green Power MODBUS uses the following functions : –– function 3 for reading Input Registers (16 bits), –– function 6 for writing single Registers (to control DELPHYS Green Power). The data field is composed of 1 word, defined by a MSB (most significant byte) and a LSB (lowest significant byte), and displayed in the following order on the serial link. 1 WORD DATA b7 MSBb0 b7 LSBb0 b15b0 4. 3. Data decoding Status and alarms Information This information are coding in bit. This means that 1 word defines 16 information. If the related bit is set to 1, this information is active or true. Measurements and counters data 1 word defines a measurement or a counter. Some values are numeric decimal signed or unsigned (0 to 65535 or from -32767 to 32767), or in hexadecimal (0x0000 to 0xFFFF). DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 5 5. Installation OF modbus rtu card 5. 1. ‘Com-Slots’ localisation The « Com-Slots » integrates all communication interfaces and it is located on the right side. 2 1 Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot 2» 5. 2. Modbus serial interface plug in The serial interface should be plugged in the slot 2, and fixed with 2 crews. 5. 3. Modbus interface in parallel system configuration There is only one MODBUS serial link interface for a parallel system configuration. One serial interface is used for the whole installation. The access to the data of the UPS module or unit is managed by the table addressing . In a parallel installation with centralized bypass, it is recommended to install the serial card in slot 2 of the bypass. 6 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Installation Inside UPS 5. 4. Connections and wiring NOTE : there is only one connection per interface (RS232 or RS422 or RS485) ENGLISH 5. 4.1. RS232 connection: –– Standard PC connection –– Sub-D 9 pins connector –– Pin 2 : Rx –– Pin 3 : Tx –– Pin 5 : GND RTX + RTX - 5. 4.2. Isolated RS485 connection –– 2 wires connection –– « dip-switch 1 » allows connecting the terminal resistor –– Insulation via “opto-coupler” –– 2 polarization resistors could be removed easily (if needed). the shield should be earthing at one point. TX + TX 5. 4.3. Isolated RS422 connection –– 4 wires connection –– « dip-switch 1 and 2 » allows connecting the terminal resistor –– Insulation via “opto-coupler” –– 4 polarization resistors could be removed easily (if needed). RX + RX - the shield should be earthing at one point. Before making any connection, please check the cabling. A wrong connection or cabling can damage the serial link interface. DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 7 Installation Inside UPS 5. 5. Com2 Serial link default settings Baud rate: 9600 bauds Parity: NONE Data: 8 bits Stop: 1 bit Slave:1 The serial link settings can be set from the control panel. 5. 6. How to change the “serial link 2” settings ? Available baud rate: 1200 - 2400 - 4800 - 9600 - 19200 bauds Parity: EVEN - ODD - NONE Slave number: 1 to 32 Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot» 8 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 6. installation of MODBUS TCP CARD 6. 1. ‘Com-Slots’ localisation ENGLISH The « Com-Slots » integrates all communication interfaces and it is located on the right side. 2 1 Please, see on the manual of the concerned UPS to see the correct localisation of the «com slot 2» 6. 2. UPS Com2 Modbus Serial link default settings Baud rate: 9600 bauds Parity: NONE Data: 8 bits Stop: 1 bit Slave:1 The serial link settings can be set from the control panel. These settings are compulsory to make the Modbus TCP communication available DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 9 6. 3. default settings of the modbus tcp interface DEFAULT SETTING DHCP mode by default. No IP address set by default Mode MODBUS TCP Port TCP 502 CONFIGURATION SOFTWARE Configuration tools are to be installed on a PC with WINDOWS. The setup programme is on the CD provided with the interface. A new programme group has been created. SEARCHING UPS CONNECTED TO THE ETHERNET The utility programme «Digi Device Discovery» is for viewing the IP and MAC addresses of each UPS. ACCESSING HTTP PAGES Data related to connection and module setting can be accessed using the web interface. The «home page» can be opened either by means of the «Discovery» utility or the Internet browser by selecting the IP address indicated by the «Discovery» utility.. Access to pages is protected by a «login» and a password. Login by default: root Password: dbps DOWNLOADING FIRMWARE By default, the module is programmed with the firmware for the MODBUS TCP function. In case of «real port» mode, the firmware on the CD must first be downloaded. For any other configurations, please refer to the DIGI® manual available on the CD. 10 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 7. Conventions The table addresses are written in hexadecimal, beginning with ‘0x’. Some PLC systems request a relative address starting from 400 (0x0190) or 40001 (0x9C41), on this address it’s necessary to add the first address of the MODBUS table. 6. 4. Frame errors management Error function code Error code 80 + code function 1 Function error 80 + code function 2 Addresses error 80 + code function 3 Wrong data 80 + code function 6 busy 80 + code function 8 Write register error ENGLISH In case of wrong data request, the DELPHYS Green Power answers with the following frame error : Cause DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 11 8. Modbus in Single UPS unit TABLE Start addresses Table length in words MODBUS FUNCTION UPS Identification 0x1100 32 3 READ Date and hours 0x1360 4 3 READ UPS Configurations 0x1200 16 3 READ UNIT Status (64 bits) 0x1143 4 3 READ UNIT Alarm (80 bits) 0x114A 5 3 READ UNIT Measurements 0x1220 96 3 READ Controls permission 0x1150 4 3 READ UPS Controls 0x1190 4 6 WRITE 8. 1. How to read data The identification, status and alarms tables should be read completely (this means the number of word to read is equal to the table length). The measurements table should be read word by word or per group, without exceed the length of the table. (from 0x1220 to 0x127F). 8. 2. Incoming data structure Example of 6 words 1 2 3 4 5 6 7 8 9 10 11 12 MSB 0 LSB 0 MSB 1 LSB 1 MSB 2 LSB 2 MSB 3 LSB 3 MSB 4 LSB 4 MSB 5 LSB 5 WORD 0 WORD 1 WORD 2 WORD 3 WORD 4 WORD 5 b15b0 b15b0 b15b0 b15b0 b15b0 b15b0 S015S000 S031S016 S047S032 S063S048 S079S064 S095S080 A015A000 A031A016 A047A032 A063A048 M004 M005 M000 12 M001 M002 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 M003 Single unit ups modbus tables 8. 3. Ups Identification: Address 0x1100, 32 Words Description Number Address Type Remarks I000 UPS identification 10 WORDS 0x1100 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I010 UPS Description 6 WORDS 0x110A 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I016 Location 6 WORDS 0x1110 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char I022 Serial number 10 WORDS 0x1116 1 word = 2 ASCII codes MSB = 1. Char, LSB = 2. Char ENGLISH Code 8. 4. Date & Hours: Address 0x1360, 4 Words Code Description Number Address Type Remarks D00 Minutes / seconds 1 WORDS 0x1360 Byte value MSB = minutes, LSB = seconds D01 Hours / day 0x1361 Byte value MSB = day, LSB = hours Month / day of D02 week D03 1 WORDS MSB = month, 1 WORDS 0x1362 Byte value LSB = day of the week 1=Monday...7=Sunday Year 1 WORDS 0x1363 00 = 2000 8. 5. Ups Configuration: Address 0x1120, 16 Words Code Measurements Unit T000 Kind of equipment Address Remarks 0x1120 1= single unit, 3= parallel + centralised bypass 6 = modular parallel system T001 UPS output power kVA 0x1121 T002 Unit output power kVA 0x1122 T003 Unit number 0x1123 1-8 T004 Number of Unit 0x1124 1-8 T005 UPS redundant 0x1125 0-1 T006 With battery 0x1126 0-1 T007 With flywheel 0x1127 0-1 T008 0x1128 T009 With genset 0x1129 T010 0x112A T011 0x112B T012 0x112C T013 With rectifier input supply 0x112D 0-1 T014 Single 0x112E 0 = Tri, 1 = Single T015 Measurements management 0x112F 0 = x 1, 1 = x 10 0-1 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 13 Single unit UPS Modbus Tables 8. 6. Unit Status: Address 0x1143, 4 Words Code Description Address 0x1143 S048 Load on inverter 0 S049 Load on auto. Bypass 1 S050 Load on maintenance Bypass 2 S051 Load not supplied 3 S052 Unit is available 4 S053 Unit isolated from inst. 5 S054 Output switch Q2/3 closed 6 S055 Rectifier ON 7 S056 Battery charging 8 S057 Battery charged 9 S058 10 S059 Inverter ON 11 S060 Inverter switch/contactor closed 12 S061 Bypass switch activated 13 S062 14 S063 Servicing alert 15 S064 Rectifier input supply fault 0 S065 Bypass input supply out of tolerance 1 S066 Bypass input supply failure V/F 2 2 S067 Bypass input supply is synchro ref 3 S068 Ext. synchro ref (ACS on) 4 S069 Synchro forced on ACS 5 S070 “UPS general power off” input active 6 S071 Generator set active 7 S072 Unit in normal mode 8 S073 Unit in eco-mode 9 S074 S075 10 Unit in stand-by mode 11 S076 12 S077 13 S078 14 S079 14 Bit Unit in servicing mode DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 15 0x1144 Remarks Single unit UPS Modbus Tables Description Bit Address 0x1145 S080 Unit Start procedure progress 0 S081 Unit maintenance bypass procedure progress 1 S082 Remarks 2 S083 Battery test interrupted 3 S084 Battery test in progress 4 S085 Battery test in stand-by 5 S086 6 S087 7 S088 8 S089 9 S090 10 S091 11 ENGLISH Code S092 Local maintenance bypass Q5 clos. 12 S093 Remote maintenance bypass closed 13 Only on parallel S094 Q21 switch closed 14 Only on parallel S095 Q22 switch closed 15 Only on parallel S096 Auxiliary input 1 active 0 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S108 12 S109 13 S110 14 S111 Acknowledgement alarm request 0x1146 15 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 15 Single unit UPS Modbus Tables 8. 7. Unit Alarms: Address 0x114A, 4 Words Code A032 A033 A034 A035 A036 A037 A038 A039 A040 A041 A042 A043 A044 A045 A046 A047 A048 A049 A050 A051 A052 A053 A054 A055 A056 A057 A058 A059 A060 A061 A062 A063 A064 A065 A066 A067 A068 A069 A070 16 Description Unit Imminent stop Unit overload Transfer blocked Transfer impossible Insufficient Resources Rectifier critical Inverter critical Bypass critical Common critical FAN alarm Back feed protection open ACS synchro source fault Operating on battery Battery alarm Battery room Battery discharged End of autonomy time Battery test failure Earth leakage fault Battery circuit open On battery with mains OK DC voltage not OK Rectifier preventive Inverter preventive Bypass preventive Common preventive Mimic panel Ambient T° max BHC general alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Bit Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 0x114A Remarks Only on parallel 0x114B 0x114C Single unit UPS Modbus Tables A071 A072 A073 A074 A075 A076 A077 A078 A079 A080 A081 A082 A083 A084 A085 A086 A087 A088 A089 A090 A091 A092 A093 A094 A095 A096 A097 A098 A099 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 Description Preventive maintenance Maintenance bypass alarm Rotation phase fault Rectifier or Bypass Input supply not OK Output since xx minutes on auto bypass Unit General alarm Fly Wheel disconnected Fly Wheel Critical Fly Wheel preventive Aux. input alarm kW - kVA configuration Error Eco-mode configuration Error Option board alarm Bit 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Address Remarks ENGLISH Code 0x114D 0x114E If set If set DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 17 Single unit UPS Modbus Tables 8. 8. Unit Measurements tables: Address 0x1220, 80 words Code M032 M033 M034 M035 M036 M037 M038 M039 M040 M041 M042 M043 M044 M045 M046 M047 M048 M049 M050 M051 M052 M053 M054 M055 M056 M057 M058 M059 M060 M061 M062 M063 M064 M065 M066 M067 M068 M069 M070 18 Description Output voltage U12 Output voltage U23 Output voltage U31 Output voltage L1 Output voltage L2 Output voltage L3 Output current L1 Output current L2 Output current L3 Output frequency x10 Output Power factor L1 Output Power factor L2 Output Power factor L3 Output Active Power L1 Output Active Power L2 Output Active Power L3 Output Apparent Power L1 Output Apparent Power L2 Output Apparent Power L3 Output Crest Factor Output load rate L1 Output load rate L2 Output load rate L3 Unit load rate Unit Power S Output Unit Power P Output Rectifier input supply volt. U12 Rectifier input supply volt. U23 Rectifier input supply volt. U31 Rectifier V1 Rectifier V2 Rectifier V3 Rectifier input supply frequency x10 Rectifier input supply current L1 Rectifier input supply current L2 Rectifier input supply current L3 Inverter output voltage U12 Inverter output voltage U23 Inverter output voltage U31 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Unit Address V V V V V V A A A Hz 0x1220 1 2 3 4 5 6 7 8 9 A B C D E F 0x1230 1 2 3 4 5 6 7 8 9 A B C D E F 0x1240 1 2 3 4 5 6 kW kW kW kVA kVA kVA % % % % kVA kW V V V V V V Hz A A A V V V Format Format T015=0 T015=1 ### ### ### ### ### ### # ### # ### # ### ##.# +/- #.## +/- #.## +/- #.## # ### # ### # ### # ### # ### # ### #.# ### ### ### ### # ### # ### ### ### ### ### ### ### ##.# ###.# ###.# ###.# ### ### ### ### ### ### ### ### ### # ###.# # ###.# # ###.# ##.# +/- #.## +/- #.## +/- #.## # ###.# # ###.# # ###.# # ###.# # ###.# # ###.# #.# ### ### ### ### # ###.# # ###.# ### ### ### ### ### ### ##.# ###.# ###.# ###.# ### ### ### Code M071 M072 M073 M074 M075 M076 M077 M078 M079 M080 M081 M082 M083 M084 M085 M086 M087 M088 M089 M090 M091 M092 M093 M094 M095 M096 M097 M098 M099 M100 M101 M102 M103 M104 M105 M106 M107 M108 M109 M110 M111 Description Format T015=0 ##.# ### ### ### ### ### ### ###.# ##.# ### Format T015=1 ##.# ### ### ### ### ### ### ###.# ##.# ### 2 ### ###.# 4 # ### # ###.# ##.# ##.# # ### ### ### ##.# ##.# # ###.# ### ### Unit Address Inverter frequency x10 Bypass input supply voltage U12 Bypass input supply voltage U23 Bypass input supply voltage U31 Bypass input supply voltage V1 Bypass input supply voltage V2 Bypass input supply voltage V3 Bypass input supply frequency x10 Ambient T° Vdc + Hz V V V V V V Hz °C V 7 8 9 A B C D E F 0x1250 Battery voltage string + V Battery current + A Battery T° Average battery T° Battery capacity Battery capacity Remaining backup time °C °C Ah % mn 6 7 8 9 A B C D E F 0x1260 1 2 3 4 5 6 7 8 9 A B C D E F DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ENGLISH Single unit UPS Modbus Tables 19 Single unit UPS Modbus Tables 8. 9. Unit Enabled Controls Table: Address 0x1150; 1 Words Code V007 V008 V032 V033 V034 V035 V036 V037 V038 V039 V040 V041 V042 V043 V044 V045 Description Eco-mode Normal-mode Unit Start procedure Reserved Make unit available Switch load to inverter Switch load to mains Switch off unit output Bit 7 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Rectifier on Rectifier off Inverter on Inverter off Battery test Address 0x1150 Remarks 0x1152 8. 10. Controls Send To Ups: Address 0x1190, write 1 words For a remote UPS control, it is necessary to set the serial interface in “remote” mode using ADICOM interface. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code C007 C008 C032 C033 C034 C035 C036 C037 C038 C039 C040 C041 C042 C043 C044 C045 C046 C047 C048 20 Description Eco-mode Normal-mode Unit Start procedure Reserved Make unit available Switch load to inverter Switch load to mains Switch off unit output Rectifier on Rectifier off Inverter on Inverter off Battery test Bit To Write 7 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Address 0x1190 0 0x1193 Reset alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Remarks 0x1192 LOAD OFF IMMEDIATE!! 9. MODBUS IN modular PARALLEL SYSTEM CONFIGURATION 9. 1. Reminder In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the possibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number. ENGLISH The interface is plugged in the UPS unit 1 “com slots 2” in case of modular system (see bellow). 1 2 3 MODBUS link setting The setting of the link is made from the mimic panel unit where the board is plugged. How to read data: In the MODBUS table, one part is dedicated to UPS part; it means the data from the whole system. This part is the same for each unit. Same data are present in the UPS fields addresses. UNIT 1 UPS DATA UNIT 1 DATA UNIT 2 = UPS DATA UNIT 2 DATA UNT 3 = UPS DATA UNIT 3 DATA DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 21 Modbus tables in modular parallel system configuration 9. 2. Modbus table in modular parallel system Table Start Addresses Table Length In Words UPS Identification 0x0100 32 3 READ Date and hours 0x0360 4 3 READ UPS Configurations 0x0200 16 3 READ UPS Status (48 bits) 0x0140 3 3 READ UNIT Status (64 bits) 0xm143 4 3 READ UPS Alarms (32 bits) 0x0148 2 3 READ UNIT Alarm (80 bits) 0xm14A 5 3 READ UPS Measurements 0x0200 32 3 READ UNIT Measurements 0xm220 80 3 READ Controls permission 0xm150 4 3 READ UPS Controls 0xm190 4 6 WRITE m = number of unit Example: 0x3100 = ID of unit 3 0x3140 = UPS States 0x3143 = unit 3 states 9. 3. Ups Identification: Address 0x0100, 32 Words See unit part 9. 4. Date & Hours: Address 0x0360, 4 Words See unit part 9. 5. Ups Configuration: Address 0xm120, 16 Words See unit part 9. 6. Preliminary Remarks The UNIT data are the same as described for single unit. Following tables describe only the UPS part (common for all units) 22 Modbus Function DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Modbus tables in modular parallel system configuration 9. 7. Ups Status: Address 0x0140, 3 Words Description Bit Address 0x0140 S000 Load supplied by inverter 0 S001 Load on automatic bypass 1 S002 Load on maintenance. Bypass 2 S003 Load not supplied 3 S004 Eco-mode 4 S005 Energy Saver 5 S006 UPS in normal mode 6 S007 UPS Starting procedure in progress 7 S008 UPS on maintenance bypass proc. in progress 8 S009 9 S010 10 S011 11 S012 UPS Bypass input supply absence 12 S013 UPS Rectifier input supply absence 13 S014 Remarks ENGLISH Code Synthesis of all units 14 S015 Remote control enabled 15 S016 Unit 1 operating 0 S017 Unit 2 operating 1 S018 Unit 3 operating 2 S019 Unit 4 operating 3 S020 Unit 5 operating 4 S021 Unit 6 operating 5 S022 Unit 7 operating 6 S023 Unit 8 operating 7 S024 8 S025 9 S026 10 S027 11 S028 12 S029 13 S030 14 S031 15 S032 Unit 1 available 0 S033 Unit 2 available 1 S034 Unit 3 available 2 S035 Unit 4 available 3 S036 Unit 5 available 4 S037 Unit 6 available 5 S038 Unit 7 available 6 S039 Unit 8 available 7 0x0141 0x0142 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 23 Modbus tables in modular parallel system configuration 9. 8. Ups Alarms: Address 0x0148, 2 Words Code 24 Description Bit Address 0x0148 A000 UPS imminent stop 0 A001 UPS overload 1 A002 UPS transfer blocked 2 A003 UPS transfer impossible 3 A004 UPS insufficient Resource 4 A005 UPS Redundancy loss 5 A006 Parallel fault 6 A007 7 A008 8 A009 UPS: Battery alarm 9 A010 UPS on battery 10 A011 UPS: Battery discharge 11 A012 UPS: End of autonomy 12 A013 UPS: Temperature alarm 13 A014 14 A015 15 A016 Unit 1 general 0 A017 Unit 2 general 1 A018 Unit 3 general 2 A019 Unit 4 general 3 A020 Unit 5 general 4 A021 Unit 6 general 5 A022 Unit 7 general 6 A023 Unit 8 general 7 A024 8 A025 9 A026 10 A027 11 A028 12 A029 13 A030 14 A031 15 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Remarks synthesis of all unit alarms 0x0149 Modbus tables in modular parallel system configuration 9. 9. Ups Measurements: Address 0x0200, 32 Words Description M000 Format T015=0 Format T015=1 Unit Address Output voltage U12 V 0x0200 ### ### M001 Output voltage U23 V 1 ### ### M002 Output voltage U31 V 2 ### ### M003 Output voltage L1 V 3 ### ### M004 Output voltage L2 V 4 ### ### M005 Output voltage L3 V 5 ### ### M006 Output current L1 A 6 # ### # ###.# M007 Output current L2 A 7 # ### # ###.# M008 Output current L3 A 8 # ### # ###.# M009 Output frequency x10 Hz 9 ##.# ##.# M010 Output Power factor L1 A +/- #.## +/- #.## M011 Output Power factor L2 B +/- #.## +/- #.## M012 Output Power factor L3 C +/- #.## +/- #.## M013 Output Active Power L1 kW D # ### # ###.# M014 Output Active Power L2 kW E # ### # ###.# M015 Output Active Power L3 kW F # ### # ###.# M016 Output Apparent P. L1 kVA 0x210 # ### # ###.# M017 Output Apparent P. L2 kVA 1 # ### # ###.# M018 Output Apparent P. L3 kVA 2 # ### # ###.# M019 Output Crest Factor 3 #.# #.# M020 Output load rate L1 % 4 ### ### M021 Output load rate L2 % 5 ### ### M022 Output load rate L3 % 6 ### ### M023 UPS load rate % 7 ### ### M024 UPS Output power kVA 8 # ### # ###.# M025 9 M026 A M027 B M028 C M029 D M030 E M031 F DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ENGLISH Code 25 Modbus tables in modular parallel system configuration 9. 10. Ups Enabled Controls Table: Address 0xm150, 2 Words Code Description Bit Address UPS Start procedure 0 0xm150 Reserved 1 Transfer load to inverter 2 Transfer load to mains 3 UPS load off 4 Energy Saver ON 5 Energy Saver OFF 6 Eco-mode 7 Normal mode 8 Remarks 9 10 11 12 13 14 15 Remark: A bit set to 0 means that the control is disabled by the UPS. The control will be not executed. 9. 11. To Send Control To Ups: Address 0x15b0, Write 1 Words For a remote UPS control, it is necessary to set the serial interface in “remote” mode using the Human Machine Interface. Local controls are then locked. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code Control Value to write Address UPS Start procedure 1 0xm190 Reserved 2 Transfer load to inverter 4 Transfer load to mains 8 UPS load off 16 Energy Saver ON 32 Energy Saver OFF 64 Eco-mode 128 Normal mode 256 512 26 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Remarks IMMEDIATE LOAD OFF !! 10.MODBUS IN PARALLEL SYSTEM with centralised bypass 10. 1. Reminder In UPS parallel system configuration, there is only one MODBUS interface. The addresses mapping gives the possibility to read data from each unit and system. There is no link between the MODBUS salve number and the unit number. ENGLISH The interface is plugged in the ‘com-slots 2’ of bypass cabinet. By-pass 1 2 MODBUS link setting The setting of the link is made from the mimic panel unit where the board is plugged. How to read data: In the MODBUS table, one part is dedicated to UPS part; it means the data from the whole system. This part is the same for each unit. Same data are present in the UPS fields addresses. BYPASS UPS DATA UNIT BYPASS (15) UNIT 1 = UPS DATA UNIT 1 DATA UNT 2 = UPS DATA UNIT 2 DATA DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 27 Modbus in parallel system with centralised bypass 10. 2. Modbus table in parallel system with centralised bypass Table Start Addresses Table Length In Words UPS Identification 0x0100 32 3 READ Date and hours 0x0360 4 3 READ UPS Configurations 0x0200 16 3 READ UPS Status (48 bits) 0x0140 3 3 READ UNIT Status (64 bits) 0xm143 4 3 READ UPS Alarms (32 bits) 0x0148 2 3 READ UNIT Alarm (80 bits) 0xm14A 5 3 READ UPS Measurements 0x0200 32 3 READ UNIT Measurements 0xm220 80 3 READ Controls permission 0xm150 4 3 READ UPS Controls 0xm190 4 6 WRITE m=1 - - - - number of module m = 8 m = 15 Bypass data Example: 0x3100 = ID of unit 3 0x3140 = UPS States 0xF143 = Bypass 3 states 10. 3. Ups Identification: Address 0x0100, 32 Words See unit part 10. 4. Date & Hours: Address 0x0360, 4 Words See unit part 10. 5. Ups Configuration: Address 0xm120, 16 Words See unit part 10. 6. Preliminary Remarks Following tables describe only the UPS part (common for all units) 28 Modbus Function DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Modbus in parallel system with centralised bypass 10. 7. Ups Status: Address 0x0140, 3 Words Description Load supplied by inverter Load on automatic bypass Load on maintenance. Bypass Load not supplied Eco-mode Energy Saver UPS in normal mode UPS Starting procedure in progress UPS on maintenance bypass proc. in progress UPS Bypass input supply absence UPS Rectifier input supply absence Remote control enabled Module 1 operating Module 2 operating Module 3 operating Module 4 operating Module 5 operating Module 6 operating Module 7 operating Module 8 operating Bypass working Module 1 available Module 2 available Module 3 available Module 4 available Module 5 available Module 6 available Module 7 available Module 8 available Bypass available Bit 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 14 Address 0x0140 Remarks ENGLISH Code S000 S001 S002 S003 S004 S005 S006 S007 S008 S009 S010 S011 S012 S013 S014 S015 S016 S017 S018 S019 S020 S021 S022 S023 S024 S025 S026 S027 S028 S029 S030 S031 S032 S033 S034 S035 S036 S037 S038 S039 S046 Synthesis of all units 0x0141 0x0142 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 29 Modbus in parallel system with centralised bypass 10. 8. Ups Alarms: Address 0x0148, 2 Words Code Description Address 0x0148 A000 UPS imminent stop 0 A001 UPS overload 1 A002 UPS transfer blocked 2 A003 UPS transfer impossible 3 A004 UPS insufficient Resource 4 A005 UPS Redundancy loss 5 A006 Parallel fault 6 A007 7 A008 8 A009 UPS: Battery alarm 9 A010 UPS on battery 10 A011 UPS: Battery discharge 11 A012 UPS: End of autonomy 12 A013 UPS: Temperature alarm 13 A014 14 A015 15 A016 Module 1 general 0 A017 Module 2 general 1 A018 Module 3 general 2 A019 Module 4 general 3 A020 Module 5 general 4 A021 Module 6 general 5 A022 Module 7 general 6 A023 Module 8 general 7 A024 8 A025 9 A026 10 A027 11 A028 12 A029 13 A030 Bypass alarm A031 30 Bit DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 14 15 Remarks synthesis of all unit alarms 0x0149 Modbus in parallel system with centralised bypass 10. 9. Ups Measurements: Address 0x0200, 32 Words Description M000 Format T015=0 Format T015=1 Unit Address Output voltage U12 V 0x0200 ### ### M001 Output voltage U23 V 1 ### ### M002 Output voltage U31 V 2 ### ### M003 Output voltage L1 V 3 ### ### M004 Output voltage L2 V 4 ### ### M005 Output voltage L3 V 5 ### ### M006 Output current L1 A 6 # ### # ###.# M007 Output current L2 A 7 # ### # ###.# M008 Output current L3 A 8 # ### # ###.# M009 Output frequency x10 Hz 9 ##.# ##.# M010 Output Power factor L1 A +/- #.## +/- #.## M011 Output Power factor L2 B +/- #.## +/- #.## M012 Output Power factor L3 C +/- #.## +/- #.## M013 Output Active Power L1 kW D # ### # ###.# M014 Output Active Power L2 kW E # ### # ###.# M015 Output Active Power L3 kW F # ### # ###.# M016 Output Apparent P. L1 kVA 0x0210 # ### # ###.# M017 Output Apparent P. L2 kVA 1 # ### # ###.# M018 Output Apparent P. L3 kVA 2 # ### # ###.# M019 Output Crest Factor 3 #.# #.# M020 Output load rate L1 % 4 ### ### M021 Output load rate L2 % 5 ### ### M022 Output load rate L3 % 6 ### ### M023 UPS load rate % 7 ### ### M024 UPS Output power kVA 8 # ### # ###.# M025 9 M026 A M027 B M028 C M029 D M030 E M031 F DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ENGLISH Code 31 Modbus in parallel system with centralised bypass 10. 10.Ups Enabled Controls Table: Address 0xm150, 2 Words Code Description Bit Address UPS Start procedure 0 0xm150 Reserved 1 Transfer load to inverter 2 Transfer load to mains 3 UPS load off 4 Energy Saver ON 5 Energy Saver OFF 6 Eco-mode 7 Normal mode 8 Remarks 9 10 11 12 13 14 15 Remark: A bit set to 0 means that the control is disabled by the UPS. The control will be not executed. 10. 11.To Send Control To Ups: Address 0x15b0, Write 1 Words For a remote UPS control, it is necessary to set the serial interface in “remote” mode using the Human Machine Interface. Local controls are then locked. The control table below shows if the selected control is allowed or not. If the control sent to the UPS is not allowed, the function will be ignored. Controls available by MODBUS connection: Code Control Value to write Address UPS Start procedure 1 0xm190 Reserved 2 Transfer load to inverter 4 Transfer load to mains 8 UPS load off 16 Energy Saver ON 32 Energy Saver OFF 64 Eco-mode 128 Normal mode 256 512 32 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Remarks IMMEDIATE LOAD OFF !! 11.Bypass TABLE 11. 1. Bypass Status: Address 0xF143, 4 Words Description Bit Address 0xF143 S048 Load on inverter 0 S049 Load on auto. Bypass 1 S050 Load on maintenance Bypass 2 S051 Load not supplied 3 S052 4 S053 5 S054 Output switch 3 closed 6 S055 7 S056 8 S057 9 S058 10 S059 1 S060 12 S061 Bypass switch activated S062 S063 13 14 Servicing alert 15 S064 0 S065 1 S066 2 S067 3 S068 4 S069 5 S070 6 S071 7 S072 Unit in normal mode 9 S074 10 S075 1 S076 12 S077 13 S078 14 Bypass in servicing mode 0xF144 8 S073 S079 Remarks ENGLISH Code 15 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 33 Bypass Tables Code Bit Address 0xF145 S080 Starting 0 S081 Unit maintenance bypass procedure progress 1 S082 2 S083 3 S084 4 S085 5 S086 6 S087 7 S088 8 S089 9 S090 10 S091 Q4 closed 11 S092 Local maintenance bypass Q5 clos. 12 S093 Remote maintenance bypass closed 13 S094 14 S095 15 S096 Auxiliary input 1 active 0 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S108 12 S109 13 S110 14 S111 34 Description Acknowledgement alarm request DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 15 0xF146 Remarks Bypass Tables 11. 2. Bypass Alarms: Address 0xF14A, 4 Words A032 A033 A034 A035 A036 A037 A038 A039 A040 A041 A042 A043 A044 A045 A046 A047 A048 A049 A050 A051 A052 A053 A054 A055 A056 A057 A058 A059 A060 A061 A062 A063 A064 A065 A066 A067 A068 A069 A070 Description Unit Imminent stop Unit overload Transfer blocked Transfer impossible Insufficient Resources Bypass critical Common critical FAN alarm Back feed protection open ACS synchro source fault Bypass preventive Bit Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 0xF14A Remarks ENGLISH Code Only on parallel 0xF14B 0xF14C DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 35 Bypass Tables Code A071 A072 A073 A074 A075 A076 A077 A078 A079 A080 A081 A082 A083 A084 A085 A086 A087 A088 A089 A090 A091 A092 A093 A094 A095 A096 A097 A098 A099 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 36 Description Preventive maintenance Maintenance bypass alarm Output since xx minutes on auto bypass Bypass General alarm Aux. input alarm Option board alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Bit 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Address Remarks 0xF14D 0xF14E If set Bypass Tables 11. 3. Bypass Measurements tables: Address 0xF220, 80 words M032 M033 M034 M035 M036 M037 M038 M039 M040 M041 M042 M043 M044 M045 M046 M047 M048 M049 M050 M051 M052 M053 M054 M055 M056 M057 M058 M059 M060 M061 M062 M063 M064 M065 M066 M067 M068 M069 M070 Description Output voltage U12 Output voltage U23 Output voltage U31 Output voltage L1 Output voltage L2 Output voltage L3 Output current L1 Output current L2 Output current L3 Output frequency x10 Output Power factor L1 Output Power factor L2 Output Power factor L3 Output Active Power L1 Output Active Power L2 Output Active Power L3 Output Apparent Power L1 Output Apparent Power L2 Output Apparent Power L3 Output Crest Factor Output load rate L1 Output load rate L2 Output load rate L3 Unit load rate Unit Power S Output Unit Power P Output Unit Address V V V V V V A A A Hz 0xF220 1 2 3 4 5 6 7 8 9 A B C D E F 0xF230 1 2 3 4 5 6 7 8 9 A B C D E F 0xF240 1 2 3 4 5 6 kW kW kW kVA kVA kVA % % % % kVA kW Format Format T015=0 T015=1 ### ### ### ### ### ### # ### # ### # ### ##.# +/- #.## +/- #.## +/- #.## # ### # ### # ### # ### # ### # ### #.# ### ### ### ### # ### # ### ### ### ### ### ### ### # ###.# # ###.# # ###.# ##.# +/- #.## +/- #.## +/- #.## # ###.# # ###.# # ###.# # ###.# # ###.# # ###.# #.# ### ### ### ### # ###.# # ###.# DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ENGLISH Code 37 Bypass Tables Code M071 M072 M073 M074 M075 M076 M077 M078 M079 M080 M081 M082 M083 M084 M085 M086 M087 M088 M089 M090 M091 M092 M093 M094 M095 M096 M097 M098 M099 M100 M101 M102 M103 M104 M105 M106 M107 M108 M109 M110 M111 38 Description Bypass input supply voltage U12 Bypass input supply voltage U23 Bypass input supply voltage U31 Bypass input supply voltage V1 Bypass input supply voltage V2 Bypass input supply voltage V3 Bypass input supply frequency x10 Ambient T° DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Unit V V V V V V Hz °C Address 7 8 9 A B C D E F 0xF250 1 2 3 4 6 7 8 9 A B C D E F 0xF260 1 2 3 4 5 6 7 8 9 A B C D E F Format T015=0 ### ### ### ### ### ### ###.# ##.# Format T015=1 ### ### ### ### ### ### ###.# ##.# 12.Module TABLE 12. 1. Module Status: Address 0xm143, 4 Words Code S048 Description Load on inverter Bit Address 0 0xm143 Remarks 1 S051 Load not supplied 3 S052 Module is available 4 S053 Module isolated from inst. 5 S054 Output switch 2 closed 6 S055 Rectifier ON 7 S056 Battery charging 8 S057 Battery charged 9 S058 10 S059 Inverter ON 11 S060 Inverter switch/contactor closed 12 S061 13 S062 14 S063 Servicing alert 15 S064 Rectifier input supply fault 0 S065 Bypass input supply out of tolerance 1 S066 S067 Bypass input supply is synchro ref 3 4 S069 5 S070 “UPS general power off” input active 6 S071 Generator set active 7 S072 Module in normal mode 8 S073 Module in eco-mode 9 S074 10 Module in stand-by mode 11 S076 12 S077 13 S078 14 S079 0xm144 2 S068 S075 ENGLISH 2 Module in servicing mode 15 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 39 Module Tables Code S080 Module Start procedure progress Bit Address 0 0xm145 S081 1 S082 2 S083 Battery test interrupted 3 S084 Battery test in progress 4 S085 Battery test in stand-by 5 S086 6 S087 7 S088 8 S089 9 S090 Q1 closed 10 S091 11 S092 12 S093 13 S094 Q21 switch closed 14 S095 Q22 switch closed 15 S096 Auxiliary input 1 active 0 S097 Auxiliary input 2 active 1 S098 Auxiliary input 3 active 2 S099 Auxiliary input 4 active 3 S100 Auxiliary input 5 active 4 S101 Auxiliary input 6 active 5 S102 Auxiliary input 7 active 6 S103 Auxiliary input 8 active 7 S104 Auxiliary input 9 active 8 S105 Auxiliary input 10 active 9 S106 Auxiliary input 11 active 10 S107 Auxiliary input 12 active 11 S108 12 S109 13 S110 14 S111 40 Description Acknowledgement alarm request DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 15 0xm146 Remarks Module Tables 12. 2. Module Alarms: Address 0xm14A, 4 Words A032 A033 A034 A035 A036 A037 A038 A039 A040 A041 A042 A043 A044 A045 A046 A047 A048 A049 A050 A051 A052 A053 A054 A055 A056 A057 A058 A059 A060 A061 A062 A063 A064 A065 A066 A067 A068 A069 A070 Description Unit Imminent stop Module overload Rectifier critical Inverter critical Common critical FAN alarm Back feed protection open Operating on battery Battery alarm Battery room Battery discharged End of autonomy time Battery test failure Earth leakage fault Battery circuit open On battery with mains OK DC voltage not OK Rectifier preventive Inverter preventive Common preventive Mimic panel Ambient T° max BHC general alarm Bit Address 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 0xm14A Remarks ENGLISH Code 0xm14B 0xm14C DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 41 Module Tables Code A071 A072 A073 A074 A075 A076 A077 A078 A079 A080 A081 A082 A083 A084 A085 A086 A087 A088 A089 A090 A091 A092 A093 A094 A095 A096 A097 A098 A099 A100 A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 42 Description Preventive maintenance Rotation phase fault Unit General alarm Fly Wheel disconnected Fly Wheel Critical Fly Wheel preventive Aux. input alarm kW - kVA configuration Error Eco-mode configuration Error Option board alarm DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 Bit 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Address Remarks 0xm14D 0xm14E If set If set Module Tables 12. 3. Module Measurements tables: Address 0xm220, 80 words M032 M033 M034 M035 M036 M037 M038 M039 M040 M041 M042 M043 M044 M045 M046 M047 M048 M049 M050 M051 M052 M053 M054 M055 M056 M057 M058 M059 M060 M061 M062 M063 M064 M065 M066 M067 M068 M069 M070 Description Output voltage U12 Output voltage U23 Output voltage U31 Output voltage L1 Output voltage L2 Output voltage L3 Output current L1 Output current L2 Output current L3 Output frequency x10 Output Power factor L1 Output Power factor L2 Output Power factor L3 Output Active Power L1 Output Active Power L2 Output Active Power L3 Output Apparent Power L1 Output Apparent Power L2 Output Apparent Power L3 Output Crest Factor Output load rate L1 Output load rate L2 Output load rate L3 Unit load rate Unit Power S Output Unit Power P Output Rectifier input supply volt. U12 Rectifier input supply volt. U23 Rectifier input supply volt. U31 Rectifier V1 Rectifier V2 Rectifier V3 Rectifier input supply frequency x10 Rectifier input supply current L1 Rectifier input supply current L2 Rectifier input supply current L3 Inverter output voltage U12 Inverter output voltage U23 Inverter output voltage U31 Unit Address V V V V V V A A A Hz 0xm220 1 2 3 4 5 6 7 8 9 A B C D E F 0xm230 1 2 3 4 5 6 7 8 9 A B C D E F 0xm240 1 2 3 4 5 6 kW kW kW kVA kVA kVA % % % % kVA kW V V V V V V Hz A A A V V V Format Format T015=0 T015=1 ### ### ### ### ### ### # ### # ### # ### ##.# +/- #.## +/- #.## +/- #.## # ### # ### # ### # ### # ### # ### #.# ### ### ### ### # ### # ### ### ### ### ### ### ### ##.# ###.# ###.# ###.# ### ### ### ### ### ### ### ### ### # ###.# # ###.# # ###.# ##.# +/- #.## +/- #.## +/- #.## # ###.# # ###.# # ###.# # ###.# # ###.# # ###.# #.# ### ### ### ### # ###.# # ###.# ### ### ### ### ### ### ##.# ###.# ###.# ###.# ### ### ### DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ENGLISH Code 43 Module Tables Code M071 M072 M073 M074 M075 M076 M077 M078 M079 M080 M081 M082 M083 M084 M085 M086 M087 M088 M089 M090 M091 M092 M093 M094 M095 M096 M097 M098 M099 M100 M101 M102 M103 M104 M105 M106 M107 M108 M109 M110 M111 44 Description Format T015=0 ##.# ### ### ### ### ### ### ###.# ##.# ### Format T015=1 ##.# ### ### ### ### ### ### ###.# ##.# ### Unit Address Ambient T° Vdc + Hz V V V V V V Hz °C V 7 8 9 A B C D E F 0xm250 Battery voltage string + V 2 ### ###.# Battery current + A 4 # ### # ###.# ##.# ##.# # ### ### ### ##.# ##.# # ###.# ### ### Frequency inverter x10 Battery T° Average battery T° Battery capacity Battery capacity Remaining backup time DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 °C °C Ah % mn 6 7 8 9 A B C D E F 0xm260 1 2 3 4 5 6 7 8 9 A B C D E F 13.ANNEXE 13. 1. 4.5-1 setting of the interface using digi® device discovery Search window for UPSs connected to the network ENGLISH Access to WEB pages Network setting 4.5-2 Network settings To set a specific IP address 4.5-3 Access to HTTP pages Login:root Password:dbps DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 45 ANNEXE 4.5-4 Home Page 4.5-5 Updating of the firmware Indicate directory of binary file to be downloaded Version of firmware: MODBUS TCP: 82001164.bin REAL PORT: 82000856_F5.bin Click on opens an on-line help window and a link to DIGI site if necessary. After completing the downloading process, click on Reboot. Wait for at least 1 minute before trying to access the interface. 46 DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 ANNEXE Problem during downloading process: If the following screen appears during downloading, it is necessary to download the POST version of the firmware (available on the CD) as well as the firmware. Updating of the firmware ENGLISH 4.5-6 13. 2. MODBUS TCP IDA specification The JBUS frames below are only examples: REQUEST BY MASTER IN MODE JBUS/MODBUS RTU Original frame: 01 03 1034 0003 40C5 Encapsulated frame: 0046 0000 0006 01 03 1034 0003 where: 0046 corresponds to the transaction number 0000 corresponds to the protocol identifier 0006 corresponds to the number of bytes (length of the message) Note: The CRC is suppressed in the encapsulated MODBUS frame. REPLY OF THE UPS IN MODE JBUS/MODBUS RTU: Original frame: 01 03 06 0002 0184 0000 1960 Encapsulated frame: 0046 0000 0009 01 03 06 0002 0184 0000 where: 0046 corresponds to the transaction number 0000 corresponds to the protocol identifier 0006 corresponds to the number of bytes (length of the message) Note: The CRC is suppressed in the encapsulated MODBUS frame. DELPHYS GREEN POWER - Ref.: IOMDGPJB0910-GB_09 47 Socomec worldwide HITCHIN HERTFORDSHIRE CIRENCESTER LONDON Power Control & Energy Efficiency Knowl Piece - Wilbury Way Hitchin Hertfordshire SG4 0TY Tel. 01462 440033 Fax 01462 431143 [email protected] UPS Units 7A-9A Lakeside Business Park Broadway Lane - South Cerney Cirencester - GL7 5XL Tel. 01285 863300 [email protected] UPS Central Court 25 Southampton Buildings London - WC2A 1AL Tel. 020 3427 5107 [email protected] in eUroPe in asia PaciFic in MiDDle easT BELGIUM PORTUGAL AUSTRALIA UNITED ARAB EMIRATES UPS / Power Control & Energy Efficiency / Solar [email protected] UPS / Solar [email protected] UPS [email protected] FRANCE ROMANIA CHINA UPS / Power Control & Energy Efficiency / Solar [email protected] UPS / Power Control & Energy Efficiency / Solar [email protected] UPS / Power Control & Energy Efficiency [email protected] RUSSIA Power Control & Energy Efficiency [email protected] Solar [email protected] UPS [email protected] UPS / Power Control & Energy Efficiency / Solar [email protected] GERMANY Power Control & Energy Efficiency [email protected] UPS [email protected] ITALY Power Control & Energy Efficiency [email protected] Solar [email protected] UPS [email protected] NETHERLANDS UPS / Power Control & Energy Efficiency / Solar [email protected] UPS / Power Control & Energy Efficiency / Solar [email protected] SLOVENIA UPS / Power Control & Energy Efficiency / Solar [email protected] SPAIN INDIA SINGAPORE UPS / Power Control & Energy Efficiency [email protected] UPS / Power Control & Energy Efficiency / Solar [email protected] THAILAND TURKEY VIETNAM UPS / Power Control & Energy Efficiency / Solar [email protected] UPS [email protected] UPS [email protected] S.A. SOCOMEC capital 10 816 800€ R.C.S. Strasbourg B 548 500 149 B.P. 60010 - 1, rue de Westhouse F-67235 Benfeld Cedex - FRANCE Tel. +33 3 88 57 41 41 Fax +33 3 88 74 08 00 [email protected] www.socomec.co.uk Power Control & Energy Efficiency [email protected] oTher coUnTries NORTH AFRICA Algeria / Morocco / Tunisia [email protected] AFRICA Other countries [email protected] SOUTH EUROPE Cyprus / Greece / Israel / Malta [email protected] [email protected] MORE DETAILS Power Control & Energy Efficiency [email protected] UPS [email protected] SOCOMEC GROUP USA, CANADA & MEXICO SOUTH AMERICA POLAND heaD oFFice in aMerica www.socomec.com/worldwide YoUr DisTriBUTor non contractual document. © 2013, socomec sa. all rights reserved. - To help protect the environment, this document has been printed on PeFc paper (Programme for the endorsement of Forest certification). The UniTeD KingDoM
© Copyright 2026 Paperzz