103-31-394-010-EH-0714.pdf 103-31-394-010-EH-0714 EC4-200-Cl2 Chlorine Electrochemical Sensor PERFORMANCE OUTLINE Range ................................................................. 0 - 200 ppm Sensitivity (see note) .......................... 250 - 650 nA/ppm Cl2 Zero in air at 20 °C..........................................<±0.4 ppm Cl2 Zero deviation (-20 to +40°C) .....................0 to -0.3 ppm Cl2 Resolution...........................................................0.1 ppm Cl2 Expected lifetime ....................................................... 2 years Linearity ...................................................linear across range Response time, t90....................................................... <30 s Temperature range .......................................... –20 to +50 °C Pressure range ................................. 90 – 110 kPa (nominal) Humidity range......................15 - 90% RH (non-condensing) Long-term output drift ........ <2% change in output per month Operating circuit............... see Electrochemical Toxic Sensor Application Note Note: This output current is negative. This is because the sensor reaction is a reduction of the target gas. OPERATING CONDITIONS Temperature range .......................................... –20 to +50 °C Operating humidity................15 - 90% RH (non-condensing) Pressure range .................................. 90 - 110 kPa (nominal) Operating circuit............... see Electrochemical Toxic Sensor Application Note Applied potential ..............................................................0 V Storage life........... 6 months in original packaging (0 - 25 °C) PHYSICAL CHARACTERISTICS Label colour ...................................................................silver Weight............................................................................... 6 g Dimensions ...........................................................see outline This device is designed to be RoHS compliant. CROSS-SENSITIVITY DATA GAS Carbon Dioxide Carbon Monoxide Chlorine Dioxide Hydrogen Hydrogen Sulfide Nitrogen Dioxide Sulfur Dioxide Ammonia Nitric Oxide Concentration (ppm) 10,000 100 1 3000 20 10 20 100 35 Sensor Response (As ppm Cl2) 0 0 3.5 0 -4 12 0 0 0 Important Note Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty. Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website. A1A-764871 Version 5, June 2010 103-31-394-010-EH-0714.pdf 103-31-394-010-EH-0714 TEMPERATURE DEPENDENCE EC4-200-Cl2 Graph of Zero vs Temperatures 2 1.5 Zero / ppm Cl2 1 0.5 0 -30 -20 -10 0 10 20 30 40 50 60 -95% conf. Average +95% conf -0.5 -1 -1.5 -2 Temperature/ Degrees Celsius EC4-200-Cl2 Graph of Net Sensitivity vs Temperature 120 110 100 % of Sensitivity @20 Deg C 90 80 70 % Sensitivity Graph -95% conf. % Sensitivity Graph Average % Sensitivity Graph +95% conf 60 50 40 30 20 10 0 -30 -20 -10 0 10 20 30 40 50 60 Temperature / Degrees Celsius A1A-764871 Version 5, June 2010 Headquarter Switzerland: Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Phone +41 44 877 35 00 [email protected] Office Germany: Pewatron AG Neumarkter Straße 86a D-81673 Munich Phone +49 89 260 38 47 [email protected] We are here for you. Addresses and Contacts. Sales Switzerland & Liechtenstein Sales International Key Accounts Postcode 3000 – 9999 Postcode 1000 – 2999 Basil Frei Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Eric Letsch Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Peter Felder Pewatron AG Thurgauerstrasse 66 CH-8052 Zurich Phone + 41 44 877 35 18 Mobile + 41 76 279 37 26 Phone + 41 44 877 35 14 Mobile + 41 76 491 66 70 Phone + 41 44 877 35 05 Mobile + 41 79 406 49 83 [email protected] [email protected] [email protected] Sales Germany Postcode 00000 – 31999 Postcode 38000 – 39999 Postcode 80000 – 99999 Postcode 32000 – 37999 Postcode 40000 – 79999 Sales Austria Kurt Stritzelberger Pewatron AG Neumarkter Straße 86a D-81673 Munich Gerhard Vetter Pewatron AG Fürstenbergstraße 12 D-55422 Bacharach-Medenscheid Kurt Stritzelberger Pewatron AG Neumarkter Straße 86a D-81673 Munich Phone + 49 89 260 52 80 Mobile + 49 171 803 41 35 Phone + 49 674 394 75 75 Mobile + 49 163 762 74 30 Phone + 49 89 260 52 80 Mobile + 49 171 803 41 35 [email protected] [email protected] [email protected] Pressure Sensors Gas sensors / Gas sensor modules Load cells Linear position sensors Angle sensors Philipp Kistler Phone + 41 44 877 35 03 [email protected] Thomas Clausen Phone + 41 44 877 35 13 [email protected] Eric Letsch Phone + 41 44 877 35 14 [email protected] Accelerometers Power supplies Current sensors Eric Letsch Phone + 41 44 877 35 14 [email protected] Sebastiano Leggio Phone + 41 44 877 35 06 [email protected] Sebastiano Leggio Phone + 41 44 877 35 06 [email protected] Drive technology CH Postcode 5000 – 9999 / DE Drive technology CH Postcode 1000 – 4999 / AT / IT / FR Roman Homa Mobile + 41 79 444 00 86 [email protected] Christian Mohrenstecher Mobile +41 76 444 57 93 [email protected] Sales Other Countries / Product Management Competitive sensor & power supply solutions worldwide
© Copyright 2026 Paperzz