Rise < 7000mm - Mitsubishi Electric Corporation

S
afety devices
The Series Z escalator is equipped with
various safety devices that provide for
safety and reliability.
For
EN115 Code
●…Standard
○ Step Motion Safety Device (CRS)
A safety device to stop the escalator when a Step has been
dislocated on its riser side due to an object caught between
the Steps, or between the Skirt Guard and the Step, or if an
abnormality has been observed in the Step motion.
● Emergency Stop Button (E-STOP)
A button to immediately stop the escalator in emergency
situations.
●* Door Open Switch (DOS)
* - EN115-1: 2008 + A1: 2010 → Standard
- EN115-1/A2: 2004 → Not applicable
● Overload Detection Device
A safety device that stops the escalator if overload has
been detected by abnormal current or temperature of the
drive motor.
● Drive Chain Safety Device (DCS)
A safety device that stops the escalator if the Drive Chain
breaks or stretches beyond an allowable limit.
● Speed Governor (GOV)
A safety device that stops the escalator if the speed
significantly decreases or increases to 120% of the rated
speed.
A safety device that stops the escalator if the speed
exceeds the rated speed, or before the Steps’
traveling direction changes due to an abnormality
such as breakage of the Drive Chain.
● Electromagnetic Brake
A safety device that stops the escalator in the case of
power failure, or if any safety device or the Emergency
Stop Button has been activated.
* A standard device for public-use escalators or those
exceeding 6m in rise.
● Step Level Device (SRS)
A safety device that stops the escalator if the horizontal
level of a Step has dropped.
○ Skirt Guard Safety Device (SSS)
A safety device to stop the escalator if a shoe or other
item becomes trapped in the gap between the Step and
Skirt Guard.
●* Handrail Speed Safety Device (HSS)
A safety device that stops the escalator if the Moving
Handrails fail to synchronize with the Steps due to
slippage, loosening or breakage of the Moving Handrails.
* - EN115-1: 2008 + A1: 2010 → Standard
- EN115-1/A2: 2004 → Optional
● Comb-Step Safety Switch (CSS)
A safety device that stops the escalator if a foreign object
becomes trapped in the gap between the Step and Comb.
L - 1 7 0 - 6 - C 7 9 4 0 0 -E
Division
Environment
Specification
Indoor
Semi-outdoor
ZS
ZL
*1
N/A
●
*1
ZP
*1
●
○ *2
Control
○
Automatic Operation with Posts (Stationary in stand-by, AC1)
system
○
Automatic Operation with Posts (Slow operation in stand-by, Inverter)
○
Post-Free Automatic Operation (Slow operation in stand-by, Inverter)
●
Stop-Buzzer Key Switch
Anti-Slip Floor Plate
●
●
Step with Anti-Slip Grooves
●
Demarcation Line
Tiered Demarcation Line
●
Safety
○
Step Demarcation Lighting
○
Comb Light
features
○/● *3
Three Horizontal Steps
○ *4
Warning System on Moving Handrail Inlet (Inlet Sensor)
○ *4
Warning System on Outer Deck (Outer Deck Sensor)
N/A
○*4 *5
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator)
N/A
Transparent tempered glass panel
●
Balustrade
N/A
Under-Handrail Lighting
● N/A
See page 12 for
sections.
Stainless steel hairline panel
●
N/A
Fluoropolymer Coating
●
Skirt Guard
Skirt Guard Lighting
○*6 N/A ○*6
Deck Board
Stainless steel hairline
●
Aluminum alloy Step Tread
●
Step
Finish and
Aluminum alloy Cleat Riser
●
Yellow Demarcation Line
●
decorative
Decorative Panel (Embossed stainless steel)
●
components Floor Plate
Floor Name
○
Comb
●
Extension of Floor Plate
○
Connection of adjacent Floor Plates
○
Moving Handrail Rubber
No. 0001 (Black)
●
(See page 5 for colors.)
○
No. 0502 to 0508
Handrail Inlet Cap Resin
●
MelEye
○
Others
Automatic oiler
○
Outdoor
AC1
Inverter (VVVF)
*1: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use.
*2: Please contact your local Mitsubishi Electric sales agent for VVVF control.
*3: A standard feature for rises exceeding 6000mm or rated speeds exceeding 0.5m/sec.
*4: Not applicable to outdoor use.
*5: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
*6: Not applicable to semi-outdoor and outdoor use.
Deck Board
Step
Skirt Guard
Floor Plate
●* Missing Step Device (SMS)
A safety device that stops the escalator if it detects a
missing step(s) before it is visible to passengers.
* - EN115-1: 2008 + A1: 2010 → Standard
- EN115-1/A2: 2004 → Not applicable
e4
●…Standard ○…Optional N/A…Not applicable
Balustrade
1) Inlet Guard
A guard made of soft rubber, which fits over the
outside of the Moving Handrail where it enters the
Balustrade to keep fingers, hands or foreign objects
away from the Moving Handrail opening.
2) Inlet Guard Switch
A safety device that stops escalator when physical
contact is made with the inlet.
A safety device that stops the escalator if the Step Chain
breaks or stretches beyond an allowable limit.
EN115 Code
Max rise (mm): 7000 (30°), 6000 (35°)
Moving Handrail
● Handrail Guard Safety Device (HGS)
● Step Chain Safety Device (SCS)
For
○…Optional
A safety switch that stops the escalator when the manhole
cover is opened.
○* Auxiliary brake
S
pecifications
Operating Panel
Escalators in the graphics are based on the Japan Code, with optional
Fluoropolymer Coating on Skirt Guard.
e1
EN 30°
EN 35°
NJ-865
RC, SRC structure Min. 270
Steel structure Min. 250
Finished floor level
50
Support beam end
Distance between support beams MM
+30
0
+40
0
Truss end
TK
Support beam section detail (by owner)
50
LA Max. 11000 for S1000, S800
Max. 11700 for S600
W2
Clearance
Min.2000
950
F.L.
RB
F.L.
R2100
Wedge guard
(by owner)
W.P.
440
440
TJ-140
NK
R1500
Floor opening
Min. 2000
Height of intermediate
support beams,180~1000.
1245
Outer sheathing
panel (by owner)
RC
SA
35°
950
W.P.
1100
1100
1030
NK-385
F.L.
Intermediate support beam is
required when TG exceeds
15000mm for Type S1000
15500mm for Type S800 or
16000mm for Type S600
1030
SA
RA
W.P.
Floor opening
Min. 1800
For VVVF control, TJ may increase from that shown. Please contact
your local Mitsubishi Electric sales agent for details.
■Standard dimensions
S600
S800
S1000
W1 (Escalator Width)
1150
1350
1550
W2 (Between Moving Handrails)
840
1040
1240
W3 (Between Skirt Panels)
610
810
1010
LF
UF
NK
NJ
2 Steps
850
1100
1550
1835
3 Steps
1440
1725
1975
2260
Without intermediate support beam
S800
S600
e2
TG
TG
13500<TG
15000<TG
TG
13850<TG
15500<TG
TG
14200<TG
16000<TG
■Reaction force on beam (N)
α・LL+ 4220・(LL-TK+X1)+12000・(TJ-X2)
LL
α・LA+4220-
RB
α・LL+ 4220・(TK-X1)+12000・(LL-TJ+X2)
LL
α・LB+12000- 12000・(TJ-X2)
LB
12000・(TJ-X2)
α・LL+ 4220・(TK-X1) +
LA
LB
RC
Type
S600
S800
S1000
W1 (Escalator Width)
1150
1350
1550
W2 (Between Moving Handrails)
840
1040
1240
W3 (Between Skirt Panels)
610
810
1010
Horizontal Steps
LF
UF
NK
NJ
2 Steps
1095
1365
1630
1900
Without intermediate support beam
RA
α・LL+ 4220・(LL-TK+1111)+12000・(TJ-1370)
LL
With intermediate support beam
α・LA+4220-
4220・(TK-1111)
LA
RB α・LL+ 4220・(TK-1111)+12000・(LL-TJ+1370)
LL
α・LB+12000- 12000・(TJ-1370)
LB
RC
α・LL+ 4220・(TK-1111) + 12000・(TJ-1370)
LA
LB
■Reaction force factors
α(N/mm)
S1000
4220・(TK-X1)
LA
RA
■Reaction force factors
Type
With intermediate support beam
Height of intermediate
support beams,180~1000.
Intermediate support beam is
required when TG exceeds
15000mm for Type S1000
15500mm for Type S800 or
16000mm for Type S600
For VVVF control, TJ may increase from that shown. Please contact
your local Mitsubishi Electric sales agent for details.
■Standard dimensions
■Reaction force on beam (N)
Type
Wiring inlet (R.H.)
Truss
RC
30°
950
RA
2390 (S1000,S800)
2940 (S600)
50
Outer sheathing
panel (by owner)
F.L.
RB
F.L.
Ceiling
Clearance
Min. 2000
HE Rise
Max. 6000
Overhead
Min. 2320
Recommended
Recommended
5
Truss
5
R1500
Wiring inlet (R.H.)
125
1515
215
91
NK
Clearance
Min.2000
F.L.
1030
NJ-385
20
91
HE Rise
Max. 7000
LB Max. 11000 for S1000, S800
Max. 11700 for S600
NJ
Safety fence
(by owner)
0
Clearance
Min. 2000
LA Max. 11000 for S1000, S800
Max. 11700 for S600
+30
0
TJ=2530 (S1000, S800)
TJ=3080 (S600)
HE/tan35°
79
Ceiling
TK=2260
50
0
Recommended
79
440
75
Truss length TG
W1
W.P.
Wedge guard
(by owner)
+40
0
W3
250
R2100
440
50
+30
0
W2
W3
Recommended
Support beam end
Truss end
NJ
Safety fence
(by owner)
Wiring inlet (R.H.)
Max.UF
Upper floor opening
Distance between support beams MM
75
Support beam section detail (by owner)
LB Max.11000 for S1000, S800
Max.11700 for S600
W1
Lower floor opening
LL=TG+250
Anchor
+30
0
TJ
HE/tan30°
1035
765
Max. LF
75
Truss length TG
Comb
250
75
Wiring inlet (R.H.)
Max. UF
Upper floor opening
LL=TG+250
Comb
950
Lower floor opening
Max. LF
Anchor
Floor opening
W1+100
Floor opening
W1+100
NK-865
Manhole cover
Manhole cover
Comb
Comb
120±10
RC, SRC structure Min. 270
Steel structure Min. 250
Finished floor level
(Unit: mm)
Manhole cover
1030
Manhole cover
Overhead
Min. 2340
(Unit: mm)
Horizontal Steps
EN115 Code
For
120±10
L
ayout
13500
15000
13850
15500
14200
16000
2 Steps
Environment
Type
Indoor
Outdoor
Semi-outdoor
5.25
5.25
5.32
5.25
4.56
4.62
4.56
3.87
3.87
3.93
3.87
S1000
S800
S600
TJ
HE 6000
2465
α(N/mm)
X1
TK
2180
X2
Type
1031 1305
3015
S1000
3 Steps
Type
S1000
S800
S600
TJ
HE 6000 6000<HE
2890
TK
X1
X2
S800
3440
3440
3440
2605
1456 1730
S600
Environment
TG
TG
13500<TG
15000<TG
TG
13600<TG
15250<TG
TG
14200<TG
16000<TG
13500
15000
13600
15250
14200
16000
Indoor
Outdoor
Semi-outdoor
5.25
5.25
5.32
5.25
4.56
4.62
4.56
3.87
3.87
3.93
3.87
e3