UL 7-12 - Ultracell

UL 7-12
12V 7AH
General
UL7-12
Terminal Type
Container Material
Rated Capacity
Part Number:
UL7-12
Length:
151 ± 2 mm (5.94 inches)
Width:
65 ± 2 mm (2.56 inches)
Container Height:
93.5 ± 2 mm (3.68 inches)
Total Height (with terminal):
99 ± 2 mm (3.90 inches)
Approx Weight:
Approx 2.05kg (4.52lbs)
Normal Voltage
12V
Normal Capacity (20HR)
7AH
Standard Terminal
F1
Optional Terminal
F2
Standard Option
ABS
Flame Retardant Option (FR)
UL94:VO
7.00 AH/0.350A
(20hr, 1.80V/cell, 25°C / 77°F)
6.51 AH/0.653A
(10hr, 1.80V/cell, 25°C / 77°F)
6.00 AH/1.20A
(5hr, 1.75V/cell, 25°C / 77°F)
5.37 AH/1.79A
(3hr, 1.75V/cell, 25°C / 77°F)
4.55 AH/4.55A
(1hr, 1.60V/cell, 25°C / 77°F)
Max Discharge Current
105A (5s)
Internal Resistance
Approx 23mΩ
Discharge Characteristics
Operating Temp. Range
Discharge: -15 ~ 50°C (5 ~ 122°F)
Charge: 0 ~ 40°C (5 ~ 104°F)
Storage: -15 ~ 40°C (5 ~ 104°F)
Nominal Operating Temp. Range
25 ± 3°C (77 ± 5°F)
Cycle Use
Initial Charging Current less than 2.1A.Voltage
Standby Use
No limit on Initial Charging Current Voltage
Capacity affected by Temperature
40°C (104°F) 103%
25°C (77°F) 100%
0°C (32°F) 86%
Design Floating Life at 20°C
5 Years
Self Discharge
Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For
higher temperatures the time interval will be shorter.
Dimensions
99 2
93 2
4.75(0.187)
3.2(0.126)
6.35(0.25)
0.8(0.031)
65 2
43 2
F1 Terminal
151 2
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
1
Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom
Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]
www.ultracell.co.uk
ISO9001
Constant Current Discharge (Amperes) at 25°C (77°F)
F.V/Time
5 min
10 min
15 min
20 min
30 min
45 min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
18.0
12.8
10.48
8.79
6.53
4.79
3.86
2.29
1.69
1.36
1.14
0.98
0.774
0.640
0.345
1.80V/cell
21.4
14.3
11.4
9.44
6.94
5.05
4.03
2.38
1.74
1.40
1.17
1.01
0.791
0.653
0.350
1.75V/cell
24.2
15.6
12.2
10.0
7.29
5.27
4.18
2.45
1.79
1.43
1.20
1.03
0.805
0.663
0.357
1.70V/cell
26.7
16.7
12.9
10.5
7.59
5.46
4.32
2.51
1.83
1.46
1.22
1.05
0.817
0.672
0.361
1.65V/cell
28.8
17.7
13.5
10.9
7.86
5.62
4.46
2.57
1.86
1.48
1.23
1.06
0.826
0.680
0.365
1.60V/cell
30.6
18.6
14.1
11.3
8.09
5.76
4.55
2.61
1.89
1.50
1.25
1.07
0.834
0.685
0.367
Constant Power Discharge (Watts) at 25°C (77°F)
F.V/Time
5 min
10 min
15 min
20 min
30 min
45 min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
34.2
24.5
20.2
17.1
12.8
9.44
7.64
4.56
3.37
2.72
2.29
1.99
1.565
1.296
0.701
1.80V/cell
40.2
27.2
21.9
18.3
13.5
9.91
7.96
4.72
3.47
2.79
2.34
2.03
1.593
1.318
0.708
1.75V/cell
45.1
29.5
23.3
19.3
14.2
10.3
8.23
4.85
3.55
2.85
2.39
2.06
1.616
1.334
0.719
1.70V/cell
49.2
31.3
24.5
20.1
14.7
10.6
8.48
4.96
3.62
2.89
2.42
2.09
1.633
1.347
0.725
1.65V/cell
52.6
32.9
25.5
20.8
15.2
10.9
8.73
5.05
3.68
2.93
2.45
2.11
1.649
1.359
0.731
1.60V/cell
55.5
34.3
26.3
21.5
15.5
11.2
8.88
5.12
3.72
2.96
2.47
2.13
1.660
1.367
0.734
Terminal Voltage (V)
Discharge Characteristics
12V
Battery
(V)
6V
4V
2V
Battery Battery Battery
(V)
(V)
(V)
13.0
6.5
4.33
2.16
12.0
6.0
4.00
2.00
11.0
5.5
3.66
1.84
10.0
5.0
3.33
1.68
9.0
4.5
3.00
1.52
8.0
4.0
2.67
1.36
Float Charging Characteristics
Charge Charging Charging
Volume Current Voltage
%
(XCA)
(V)
(V)
Temperature:25°C(77°F)
0.4C
1C
3C
1
2
4
0.207C
0.093C 0.05C
0.628C
2C
6 8 10
20
40 60
2
4
Min
6 8 10
0.25
120
110
100
90
80
70
60
50
40
30
20
10
0
20
0.20
0.15
15.0
7.5
1.40
7.0
13.0
6.5
0.10
12.0
6.0
0.05
11.0
5.5
0.10CA-2.25V/cell temperature 25°C
2.33
Charge Voltage
(Constant 2.25v/cell)
1.83
Charging Current
0
0
4
8
16
12
Life Expectancy (year)
Capacity (%)
0. 2 C A
1.0 CA
3.0 CA
2.0 CA
20
-10
0
10
20
30
40
20
68
50
30
86
Remaining Capacity (%)
Capacity(%)
30%
DOD
Ambient Temperature:
25°C (77°F)
200
400
600
800
1000
250C
60
B
300C
40 C
0
40
A
C
20
0
2
4
6
8
10
Storage Time (Months)
12
A
No supplementary required
(Carryout supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use. Optional charging way as below:
1. Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell.
2. Charged for above 20 hours at limited current 0.25CA and constant voltage 2.25Vcell.
3. Charged for 8 ~ 10 hours at limited current 0.05 CA.
C
Supplementary charge may often fail to recover the capacity.
The battery should never be left standing till this is reached.
1200
Number of Cycles
100C
80
0
0
50 °C
122 °F
100
80
0
40
104
Self Discharge Characteristics
100
20
40
1
120
40
36
2
Testing condition
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 0.25C max, voltage 2.45V/cell;
Charging volume:125% of discharged capacity.
50%
DOD
32
Battery Temperature
Cycle Life in Relation to Depth of Discharge
100%
DOD
28
Charging voltage:
2.25V/cell
Temperature (°C)
60
24
10
8
6
5
4
3
0.5
0
-20
20
Effect of Temperature on Long Term Float Life
A
0.05 C
0.1 CA
40
2.00
Charging Time (Hours)
120
60
2.17
After 50% Discharge
After 100% Discharge
h
Temperature Effects in Relation to Battery Capacity
80
2.50
Charged Volume
Discharge Time
100
Charging
Voltage
(V)
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
2
Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom
Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected]
www.ultracell.co.uk
ISO9001