SWITCHABLE FILTER (L TYPE) COS-L MODEL 1MPa(10kgf/cm2) 1.This is a steel-structure, switchable duplex housing. Maximum operating pressure……1MPa(10kgf/F) 2.Easy handle operation allows changing and cleaning of element without interrupting of operation. 3.Element material - nominal rated medium and strainer … Type A. Notch wire … Type B. Flow direction is different between type A and B. 4.Standard flange is JIS 10K-FF. 5.Due to the cock structure, internal leak occurs in the stand-by period. (Leakage is adjusted within the specified volume as shown in the table on the next page). COS-L-08∼24 A C d 6 4-d 1 7 For COS-L 04,06 Name plate 6 PART LIST "O"ring "O"ring "O"ring Packing Packing "O"ring F B L 7 d ロ R イ 11 JIS-10K PL,FF 04,08,12,20,28 Matching flange is a different I.D.flange. 4 5 3 20 19 13 15 Bolt 2 17 SS C1220T-11/2H Pressure balancing line h2 16 Air bleed plug Drain plug C3771 SCM435 SCM435 Matching flange SS400 E h 12 9 21 Hexagon socket cap screw Blank cap Blank pulg Bolt Stud bolt Hexagon socket set screw Cock holder Handle Cock Cover h1 1 d2 10 Handle position when filter is switched (as seen from the handle side) A Left in operation, right in stand-by. B Left in stand-by, right in operation. Main body ILL # 2 4 2 NAME SCM435 SS400 SCM435 SS400 SS400 SCM435 FCD450 FCD450 FCD450 SS400 STPG370 SS400 MATERIAL 4 1 1 2 2 2 1 1 1 2 With bolts, nuts and gasket COS-L-08∼24 COS-L-04・06 With nut 1 QTY REMARKS ( Dimension CODE Part Size MODEL COS-L-04 15A COS-L-06 20A COS-L-08 25A COS-L-10 32A COS-L-12 40A COS-L-16 50A COS-L-20 65A COS-L-24 80A COS-L-28 90A COS-L-32 100A JISB 2401.1A COS-L-12-24 COS-L-04-10 2 Filter element 8 〃 〃 JISB 2401.1A 1 H 18 14 1 1 1 4 2 2 8 6 NBR NBR NBR NBR NBR NBR Distance for Element Removal Element Weight ) = B type "O"ring and packing (kg) 272 110 252 90 12 335 135 310 110 15 415 160 390 135 15 620 250 580 210 19 760 320 700 260 19 15A 20A 25A 32A 40A 50A 65A 80A 90A 100A 170 150 313 155 55 540 150 62.2 25 G-60 t3×φ91/φ78 t2×φ56/φ39 P-38 P-25 − 200 250 388 201 70 680 200 82.2 32 G-80 t3×φ116/φ103 t2×φ78/φ59 P-50 P-30 G-55 250 250 476 246 95 830 250 102.2 60 G-105 t3×φ142/φ128 t2×φ98/φ74 G-80 P-50 G-80 t2×φ140/φ116 G-120 P-55 G-120 t2×φ202/φ162 G-135 G-55 G-140 320 300 725 415 135 1320 400 153.0 140 G-155 t3×φ218/φ200 (423) (147.0) 450 300 902 526 158 1550 550 59 202 250 G-210 G-250 ASSEMBLY PART NUMBER Port Size CODE PORT SIZE 15A 04 20A 06 25A 08 32A 10 40A 12 50A 16 65A 20 80A 24 90A 28 100A 32 Fluid flow direction Filter Medium Code CODE CODE 60K 100K 150K 200K 50UK 60W 100W 150W 200W 50UW 40UW 20UW 10UW 5UW 40U 20U 10U FLOW DIRECTION Flow direction for nominal rated medium and strainer A (See the drawing below) Flow direction for notch wire B (See the drawing below) Sample part number COS-L-08-A-10U MATERIAL 60Mesh 100Mesh 150Mesh 200Mesh 50Micron 60Mesh 100Mesh 150Mesh 200Mesh 50Micron 40Micron 20Micron 10Micron 5Micron 40Micron 20Micron 10Micron Notch wire Strainer Nominal Rated Medium Flow direction A and B Flow direction A Flow direction B IN OUT IN OUT IN IN OUT OUT REPLACEMENT ELEMENT PART NUMBER Fluid flow direction Port Size Filter Medium Code Sample part number P-COS-L-06-A-10U PRESSURE DROP INFORMATION ISO VG32 Viscosity: 32 cSt (40℃) Viscosity 35cSt Operating housing 8 -0 0.15 0 Condition -1 Amount of leakage Leakage 0.2 -04 housing to the stand-by housing through cock clearance,it is specified as shown in table below. -06 PRESSURE DROP (MPa) Cock leakage : Amount of fluid leakage from the operating -1 0.1 2 6 -1 -20 0.05 -24 Stand-by housing 0 100 400 -1 0 8 -0 0.1 -12 -16 0.05 0.05 -16 -20 -24 100 200 300 400 600 -06 0.15 -12 0 500 0.2 -04 PRESSURE DROP (MPa) -0 -1 0.1 0 8 -04 0.15 300 150Mesh(150W) 0.2 -06 PRESSURE DROP (MPa) 150Mesh(150K) 200 500 -20 -24 0 600 60 100 200 300 400 500 600
© Copyright 2026 Paperzz