COS-L MODEL

SWITCHABLE FILTER (L TYPE)
COS-L MODEL
1MPa(10kgf/cm2)
1.This is a steel-structure, switchable duplex housing.
Maximum operating pressure……1MPa(10kgf/F)
2.Easy handle operation allows changing and cleaning of
element without interrupting of operation.
3.Element material - nominal rated medium and strainer …
Type A. Notch wire … Type B.
Flow direction is different between type A and B.
4.Standard flange is JIS 10K-FF.
5.Due to the cock structure, internal leak occurs in the
stand-by period. (Leakage is adjusted within the specified
volume as shown in the table on the next page).
COS-L-08∼24
A
C
d
6
4-d 1
7
For COS-L 04,06
Name plate
6
PART LIST
"O"ring
"O"ring
"O"ring
Packing
Packing
"O"ring
F
B
L
7
d
ロ
R
イ
11 JIS-10K PL,FF
04,08,12,20,28 Matching flange is
a different I.D.flange.
4
5
3 20 19 13 15
Bolt
2
17
SS
C1220T-11/2H
Pressure balancing line
h2
16
Air bleed plug
Drain plug
C3771
SCM435
SCM435
Matching flange
SS400
E
h
12
9 21
Hexagon socket cap screw
Blank cap
Blank pulg
Bolt
Stud bolt
Hexagon socket set screw
Cock holder
Handle
Cock
Cover
h1
1
d2
10
Handle position when filter is switched
(as seen from the handle side)
A Left in operation, right in stand-by.
B Left in stand-by, right in operation.
Main body
ILL #
2
4
2
NAME
SCM435
SS400
SCM435
SS400
SS400
SCM435
FCD450
FCD450
FCD450
SS400
STPG370
SS400
MATERIAL
4
1
1
2
2
2
1
1
1
2
With bolts, nuts
and gasket
COS-L-08∼24
COS-L-04・06
With nut
1
QTY
REMARKS
(
Dimension
CODE Part
Size
MODEL
COS-L-04 15A
COS-L-06 20A
COS-L-08 25A
COS-L-10 32A
COS-L-12 40A
COS-L-16 50A
COS-L-20 65A
COS-L-24 80A
COS-L-28 90A
COS-L-32 100A
JISB 2401.1A
COS-L-12-24
COS-L-04-10
2
Filter element
8
〃
〃
JISB 2401.1A
1
H
18
14
1
1
1
4
2
2
8
6
NBR
NBR
NBR
NBR
NBR
NBR
Distance for
Element Removal
Element Weight
) = B type
"O"ring and packing
(kg)
272 110 252
90
12
335 135 310 110
15
415 160 390 135
15
620 250 580 210
19
760 320 700 260
19
15A
20A
25A
32A
40A
50A
65A
80A
90A
100A
170 150 313 155
55
540 150 62.2
25
G-60
t3×φ91/φ78
t2×φ56/φ39
P-38
P-25
−
200 250 388 201
70
680 200 82.2
32
G-80
t3×φ116/φ103
t2×φ78/φ59
P-50
P-30
G-55
250 250 476 246
95
830 250 102.2 60 G-105 t3×φ142/φ128
t2×φ98/φ74
G-80
P-50
G-80
t2×φ140/φ116
G-120
P-55
G-120
t2×φ202/φ162
G-135 G-55 G-140
320 300 725 415 135 1320
400 153.0
140 G-155 t3×φ218/φ200
(423) (147.0)
450 300 902 526 158 1550 550
59
202 250 G-210
G-250
ASSEMBLY PART NUMBER
Port Size
CODE PORT SIZE
15A
04
20A
06
25A
08
32A
10
40A
12
50A
16
65A
20
80A
24
90A
28
100A
32
Fluid flow direction
Filter Medium Code
CODE
CODE
60K
100K
150K
200K
50UK
60W
100W
150W
200W
50UW
40UW
20UW
10UW
5UW
40U
20U
10U
FLOW DIRECTION
Flow direction for nominal
rated medium and strainer
A
(See the drawing below)
Flow direction for
notch wire
B
(See the drawing below)
Sample part number
COS-L-08-A-10U
MATERIAL
60Mesh
100Mesh
150Mesh
200Mesh
50Micron
60Mesh
100Mesh
150Mesh
200Mesh
50Micron
40Micron
20Micron
10Micron
5Micron
40Micron
20Micron
10Micron
Notch
wire
Strainer
Nominal
Rated Medium
Flow direction A and B
Flow direction A
Flow direction B
IN
OUT
IN
OUT
IN
IN
OUT
OUT
REPLACEMENT ELEMENT PART NUMBER
Fluid flow direction
Port Size
Filter Medium Code
Sample part number P-COS-L-06-A-10U
PRESSURE DROP INFORMATION
ISO VG32
Viscosity: 32 cSt
(40℃)
Viscosity
35cSt
Operating housing
8
-0
0.15
0
Condition
-1
Amount of leakage
Leakage
0.2
-04
housing to the stand-by housing through cock
clearance,it is specified as shown in table below.
-06
PRESSURE DROP (MPa)
Cock leakage : Amount of fluid leakage from the operating
-1
0.1
2
6
-1
-20
0.05
-24
Stand-by housing
0
100
400
-1
0
8
-0
0.1
-12
-16
0.05
0.05
-16
-20
-24
100
200
300
400
600
-06
0.15
-12
0
500
0.2
-04
PRESSURE DROP (MPa)
-0
-1
0.1
0
8
-04
0.15
300
150Mesh(150W)
0.2
-06
PRESSURE DROP (MPa)
150Mesh(150K)
200
500
-20
-24
0
600
60
100
200
300
400
500
600