View PDF - Bell Power Systems, Inc.

North America and Brazil
John Deere Power Systems
3801 West Ridgeway Avenue
P.O. Box 5100
Waterloo, IA 50704-5100
Phone 800-533-6446
FAX 319-292-5075
[email protected]
Mexico
Industrias John Deere S.A. de C.V.
Boulevard Diaz Ordaz No. 500
Garza Garcia, Nuevo Leon 66210
Mexico
Phone 52 (81) 8040-1212
FAX 52 (81) 1052-8482
Europe, Africa and Middle East
John Deere Power Systems
Usine de Saran
La Foulonnerie -B.P. 11013
45401 Fleury-les-Aubrais Cedex - France
Phone (33) 2 38 82 61 19
FAX (33) 2 38 82 60 00
[email protected]
Central America, South America
and Caribbean
Tradewinds Power Corp.
5820 NW 84th Avenue
Miami, FL 33166
Phone 305-592-9745
FAX 305-592-7461
Argentina
Industrias John Deere Argentina, S.A.
Juan Orsetti 481
2152 Grandero Baigorria
Sante Fe, Argentina
Phone 54-341-471-8000
FAX 54-341-471-8001
Australia and New Zealand
John Deere Limited,
Power Systems Division
49 Smeaton Grange Road
Narellan NSW 2567 Australia
Phone 612 46474857
FAX 612 46461236
Far East
John Deere Asia Ltd
Suite 903, 9th Floor
Lippo Sun Plaza, 28 Canton Road
Tsim Sha Tsui, Kowloon,
Hong Kong
Phone 852 3105 0818
FAX 852 3105 0331
www.JohnDeere.com/gendrive
[email protected]
DSWT39 Litho in U.S.A. (05-11)
© 2005 JOHN DEERE
Generator Drive
Diesel Engine Ratings
Contents
Engine Identification........................................2–3
Features and Benefits .....................................4–5
Generator Drive Engines
Non-Regulated PowerTech..........................6–9
Tier 1 PowerTech .....................................10–11
Tier 2 PowerTech .....................................12–13
Tier 3 PowerTech E
Tier 3 PowerTech Plus.............................14–15
Conversions........................................................16
Identification Plate
Factory Manufactured by:
RG
Waterloo, IA
CD
Saran, France
PE
Torreon, Mexico
*RG 6135 H 123456*
JOHN DEERE
Engine Serial Number
*RG6135H123456*
Number of Cylinders and Total Displacement
6135 6 Cylinders, 13.5 Liters
6125 6 Cylinders, 12.5 Liters
6090 6 Cylinders, 9.0 Liters
6081 6 Cylinders, 8.1 Liters
6068 6 Cylinders, 6.8 Liters
4045 4 Cylinders, 4.5 Liters
5030 5 Cylinders, 3.0 Liters
3029 3 Cylinders, 2.9 Liters
4024 4 Cylinders, 2.4 Liters
Air Intake System
D
Naturally Aspirated
T
Turbocharged
A
Turbocharged and Aftercooled, Air-to-Water
H
Turbocharged and Aftercooled, Air-to-Air
Engine Serial Number
RG6135HF485
DEERE & COMPANY MOLINE, ILLINOIS MADE IN USA
RG 6 135 H F 485
Engine Controls (Tier 3/Stage III A)
0
Mechanical Controls
5
Electronic Controls
Emissions Certification
001
Tier 1/Stage I
070
Tier 2/Stage II
8
Tier 3/Stage III A
9
Interim Tier 4/Stage III B
Model Designation Key
Below is a key for the engine models shown in this guide.
A model designated as 6135H is a 6-cylinder, 13.5 liter
turbocharged and aftercooled, air-to-air engine. A model
designated as a 4045T is a 4-cylinder, 4.5 liter
turbocharged engine.
Valves Per Cylinder (Tier 3/Stage III A)
2
2-Valves
4
4-Valves
User Type
F
OEM (John Deere Power Systems)
XX
Other letters are used to identify
John Deere Equipment
Manufacturing Locations
613 5 H
Indicates Air Intake System
Displacement in Liters
Number of Cylinders
2
3
Features and Benefits
Standby and Prime
John Deere Generator Drive Engines for
Standby and Prime Applications
Power Density
Options and accessories
• Best-in-class power density
– Standby: 4.5L, 6.8L, 12.5L, and 13.5L
– Prime: 4.5L, 6.8L, 12.5L, and 13.5L
• Competitive power density
– Standby: 2.4L, 3.0L, 8.1L, and 9.0L
– Prime: 2.4L, 3.0L, 8.1L, and 9.0L
Emissions
• Full EPA emissions-certified product range
(2.4L–13.5L)
• Non-certified engines also available for
non-regulated markets
4
•
•
•
•
•
•
Oil pans, fuel filter sizes, and instrument panel types
Cooling packages
Air cleaner element types
Optional auxiliary drive
Wide range of fan speed ratios
Either-side engine service
User-friendly features
• Low operating costs and low maintenance
requirements
• Exceptional block-loading response capabilities
• Outstanding reliability and durability
• Longer service intervals
• Excellent cold starting
• Low noise
5
TM
Generator Drive Power Ratings 50 Hz
Engine
Model
6
Rated
Speed
Engine Power
Prime
Engine Power
Standby
Prime
Ratings
Standby
Ratings
Typical
Generator
Efficiency
Typical
Fan
Power
RPM
kW
hp
kVA
kWe
kW
hp
kVA
kWe
%
kW
3029D
1500
27
36
28-29
22-23
31
41
32-34
26-27
88-92
2.0
3029T
1500
38
51
40-41
32-33
42
56
44-46
35-37
88-92
2.0
4024T
4024T
1500
1500
19
28
25
38
20
30
16
24
21
31
28
42
23
34
18
27
88
88
0.1
1.0
4045D
4045T
4045T
4045T
4045T
4045H
4045H
4045H
1500
1500
1500
1500
1500
1500
1500
1500
40
56
63
63
75
72
91
109
54
75
84
84
101
96
122
146
41-44
59-62
65-68
66-70
79-83
76-80
96-100
112-118
33-35
47-50
52-54
53-55
63-66
61-64
77-80
90-94
44
62
70
70
83
80
102
120
59
83
94
94
111
107
137
161
46-49
66-69
73-76
74-78
88-92
85-89
108-113
125-131
37-39
53-55
58-61
59-62
70-74
68-71
86-90
100-104
88-92
88-92
88-92
88-92
88-92
88-92
88-92
88-92
2.0
2.0
3.5
2.5
4.8
3.0
4.0
6.0
5030T
5030H
1500
1500
38
56
50
75
40
60
32
48
42
62
56
84
45
66
36
53
88
88
1.3
1.9
6068T
6068T
6068T
6068T
6068H
6068H
6068H
6068H
1500
1500
1500
1500
1500
1500
1500
1500
85
94
95
109
111
140
166
188
114
126
127
146
149
188
223
252
90-94
100-104
100-105
115-121
117-123
148-155
175-183
195-204
72-75
80-83
80-84
92-97
94-98
118-124
156-163
156-163
94
104
105
121
123
155
183
207
126
139
141
162
165
208
245
278
100-104
110-116
111-116
129-135
130-136
165-172
194-202
216-226
80-83
88-93
89-93
103-108
104-109
132-138
155-162
173-181
88-92
88-92
88-92
88-92
88-92
88-92
88-92
88-92
3.5
3.5
3.5
4.0
4.5
5.5
6.5
10.4
6081T
6081T
6081A
6081A
6081A
6081H
6081H
1500
1500
1500
1500
1500
1500
1500
119
144
142
168
192
182
231
160
193
190
225
257
244
310
125-131
152-159
150-157
178-186
202-212
192-201
244-255
100-105
121-127
120-126
142-149
162-169
154-161
195-204
131
169
157
187
225
200
268
175
227
210
250
302
268
359
139-145
179-187
166-174
199-207
239-250
212-222
284-297
111-116
143-150
133-139
159-166
191-200
170-178
227-238
88-92
88-92
88-92
88-92
88-92
88-92
88-92
4.5
6.0
5.5
6.5
8.0
7.0
9.5
6125H
6125H
6125H
6125H
6125H
1500
1500
1500
1500
1500
275
273
318
320
350
368
366
427
429
469
291-304
288-302
337-352
339-354
370-388
233-243
231-241
269-281
271-283
296-310
302
300
350
352
387
405
402
469
472
519
320-335
318-333
372-388
374-390
411-429
256-268
255-266
297-311
299-312
329-344
88-92
88-92
88-92
88-92
88-92
10.5
10.5
12.3
12.5
13.5
All ratings are subject to change.
Non-Regulated PowerTech
Non-regulated PowerTech
7
TM
Generator Drive Power Ratings 60 Hz
Engine
Model
8
Rated
Speed
Engine Power
Prime
RPM
kW
3029D
1800
4045T
1800
All ratings are subject to change.
Prime
Ratings
Engine Power
Standby
kW
hp
kVA
kWe
31
42
31-33
25-26
35
90
121
94-98
75-78
100
hp
Standby
Ratings
Typical
Generator
Efficiency
Typical
Fan
Power
kVA
kWe
%
kW
47
35-37
28-30
88-92
3.0
134
104-109
83-87
88-92
4.8
Non-Regulated PowerTech
Non-regulated PowerTech
9
Tier 1 PowerTech
TM
Engine
Model
10
Rated
Speed
Engine Power
Prime
Prime
Ratings
Engine Power
Standby
Standby
Ratings
Typical
Generator
Efficiency
Typical
Fan
Power
RPM
kW
hp
kVA
kWe
kW
hp
kVA
kWe
%
kW
3029T
1800
43
58
44-46
35-37
48
64
49-51
39-41
88-92
3.0
4045D
4045T
4045T
4045T
4045T
4045T
4045H
4045H
1800
1800
1800
1800
1800
1800
1800
1800
48
67
74
76
82
90
86
111
64
90
99
102
110
121
115
149
50-52
70-73
76-80
79-82
85-89
94-98
89-93
115-120
40-42
56-58
61-64
63-66
68-71
75-78
71-74
92-96
53
74
82
84
91
100
95
123
71
99
110
113
122
134
127
165
55-58
78-81
85-90
88-92
95-100
105-109
99-104
129-134
44-46
62-65
68-72
70-74
76-80
84-87
79-83
103-107
88-92
88-92
88-92
88-92
88-92
88-92
88-92
88-92
2.6
3.7
4.1
4.1
4.5
5.0
4.8
6.0
6068T
6068T
6068T
6068T
6068H
6068H
6068H
1800
1800
1800
1800
1800
1800
1800
101
111
112
128
133
168
189
135
149
150
172
178
225
253
105-110
115-120
116-121
132-139
137-144
174-182
196-205
84-88
92-96
93-97
106-111
110-115
139-146
157-164
112
123
124
142
148
187
210
150
165
166
190
198
251
282
116-122
129-134
129-135
148-155
154-161
195-204
220-230
93-98
103-107
103-108
118-124
123-129
156-163
176-184
88-92
88-92
88-92
88-92
88-92
88-92
88-92
5.6
6.3
6.3
7.1
7.5
9.3
10.4
6081T
6081T
6081A
6081A
6081A
6081H
6081H
1800
1800
1800
1800
1800
1800
1800
142
166
168
201
220
218
263
190
223
225
270
295
292
353
147-154
172-180
174-182
209-219
228-238
226-236
273-285
118-123
138-144
139-146
167-175
182-190
181-189
218-228
157
194
187
224
259
240
308
211
260
250
300
347
322
413
164-172
202-211
195-204
234-244
270-282
251-262
322-336
131-138
162-169
156-163
187-195
216-226
201-210
258-269
88-92
88-92
88-92
88-92
88-92
88-92
88-92
7.8
9.5
9.3
11.2
13.0
11.9
15.3
6125A
6125H
6125H
1800
1800
1800
300
327
382
402
439
512
311-326
340-356
397-415
249-261
272-285
318-332
6125H
1800
418
561
404-421
323-337
330
360
420
460
442
483
563
617
344-360
376-394
439-459
491-514
275-288
301-315
351-367
393-411
88-92
88-92
88-92
90-94
16.4
17.9
20.9
23.1
All ratings are subject to change.
Tier 1 PowerTech
Generator Drive Power Ratings 60 Hz
11
Tier 2 PowerTech
TM
Engine
Model
12
Rated
Speed
Engine Power
Prime
Engine Power
Standby
Prime
Ratings
Standby
Ratings
Typical
Generator
Efficiency
Typical
Fan
Power
RPM
kW
hp
kVA
kWe
kW
hp
kVA
kWe
%
kW
3029T
1800
44
59
46-48
37-38
48
64
50-52
40-42
88-92
2.4
4024T
1800
32
43
34
27
36
48
38
30
88
1.8
4045D
4045T
4045T
4045H
4045H
4045H
1800
1800
1800
1800
1800
1800
46
67
76
98
106
130
62
90
102
131
142
174
48-50
70-73
79-83
102-107
109-115
134-141
38-40
56-58
64-66
82-85
87-92
107-112
50
74
84
108
117
143
67
99
113
145
157
192
52-55
77-81
88-92
113-118
121-128
148-156
42-44
62-65
70-73
90-94
97-102
119-124
88-92
88-92
88-92
88-92
88-92
88-92
2.5
3.7
4.2
5.4
5.9
7.2
5030T
5030H
1800
1800
54
65
72
87
56
68
45
54
60
72
80
96
63
75
50
60
88
88
3.0
3.6
6068T
6068H
6068H
6068H
6068H
1800
1800
1800
1800
1800
112
149
170
191
213
150
200
228
256
286
116-122
155-162
177-185
198-207
221-231
93-97
124-130
141-148
159-166
177-185
123
164
187
210
234
165
220
250
282
314
129-134
171-179
195-204
219-229
245-256
103-108
137-143
156-163
176-184
196-205
88-92
88-92
88-92
88-92
88-92
6.2
8.2
9.4
10.5
11.7
6081H
6081H
6081H
6081H
1800
1800
1800
1800
210
236
263
289
282
317
352
388
226-236
254-266
283-295
311-325
181-189
203-212
226-236
249-260
231
260
289
318
310
349
388
426
249-261
281-293
312-326
343-359
200-208
225-235
250-261
275-287
90-94
90-94
90-94
90-94
11.6
13.0
14.5
15.9
6125H
6125H
6125H
6125H
1800
1800
1800
1800
300
327
382
418
402
439
512
561
312-326
340-356
397-415
435-454
249-261
272-285
318-332
348-364
330
360
420
460
442
483
563
617
345-361
376-394
439-459
481-503
276-288
301-315
351-367
385-402
88-92
88-92
88-92
88-92
16.4
17.9
20.9
23.0
All ratings are subject to change.
Tier 2 PowerTech
Generator Drive Power Ratings 60 Hz
13
TM
Generator Drive Power Ratings 60 Hz
Engine
Model
Rated
Speed
Engine Power
Prime
Engine Power
Standby
Prime
Ratings
Standby
Ratings
Typical
Generator
Efficiency
Typical
Fan
Power
RPM
kW
hp
kVA
kWe
kW
hp
kVA
kWe
%
kW
6068H
1800
214
286
226
181
235
315
250
200
90
12.9
6090H
6090H
6090H
6090H
6090H*
1800
1800
1800
1800
1800
208
235
261
287
311
279
315
350
384
417
226
255
284
312
338
181
204
227
249
271
229
258
287
315
344
307
346
385
422
461
250
281
312
344
375
200
225
250
275
300
92
92
92
92
92
12.6
14.2
15.8
17.3
18.9
6135H
6135H
6135H*
1800
1800
1800
365
419
466
489
561
624
397
455
508
317
364
407
401
460
516
538
617
691
438
500
562
350
400
450
92
92
92
22.1
25.3
28.4
Typical
Generator
Efficiency
Typical
Fan
Power
Tier 3 PowerTech Plus & PowerTech E
Tier 3 PowerTech Plus
Tier 3 PowerTech E
TM
Generator Drive Power Ratings 60 Hz
Engine
Model
Rated
Speed
Engine Power
Prime
RPM
kW
Engine Power
Standby
Prime
Ratings
hp
kVA
kWe
kW
hp
Standby
Ratings
kVA
kWe
%
kW
4045T*
1800
63
85
67
54
70
94
75
60
90
3.9
4045H*
1800
85
114
90
72
94
126
100
80
90
5.2
4045H*
1800
105
142
112
90
117
157
125
100
90
6.4
6068H
6068H
1800
1800
134
161
180
216
141
169
113
135
147
177
197
237
156
186
125
149
90
90
8.0
11.0
*Preliminary data, ratings are subject to change.
14
All ratings are subject to change.
15
Conversions
Customer Support
Brake Horsepower (BHP)
BHP = ______________
RPM x Torque
With more than 4,000 service locations
worldwide, John Deere is always handy when
you need service and support. You’ll find an
authorized John Deere dealer or engine
distributor almost anywhere in the world.
5252
Torque
Torque =____________
BHP x 5252
RPM
Fuel Consumption
Gal/hr =_____________
BHP x BSFC
7.2 lbs/gal
Generator Drive Rating (kWe)
kWe = [Engine Power (kW) Fan Power Loss (kW)]
x Generator Efficiency
Power Factor (PF)
PF = kWe/kVA = ___________
Real Power
Apparent Power
PF Constant = 0.80
English to Metric
Newton-meter = lb-ft x 1.356
Newton = lb force x 4.448
Meter = ft x 0.3048
Millimeter = in x 25.4
Kilogram = lb x 0.454
Liter = gal x 3.785
Liter = cu in x 0.01639
Kilowatt = hp x 0.746
x amps))
(Kilowatt = (volts
1000
Celsius = (deg F-32) x 0.556
16
We have centralized parts warehouses in the
United States and Europe, plus numerous
worldwide depots that employ overnight parts
shipping—so you’ll never have to wait long for
parts. In addition, John Deere service
personnel are highly trained technicians who
stay on top of changing engine technologies
and service techniques.
John Deere dealers and distributors are your
best source for service, knowledge, and engine
accessories. They’re one of the many reasons
to specify John Deere engines in your
generator sets.