North America and Brazil John Deere Power Systems 3801 West Ridgeway Avenue P.O. Box 5100 Waterloo, IA 50704-5100 Phone 800-533-6446 FAX 319-292-5075 [email protected] Mexico Industrias John Deere S.A. de C.V. Boulevard Diaz Ordaz No. 500 Garza Garcia, Nuevo Leon 66210 Mexico Phone 52 (81) 8040-1212 FAX 52 (81) 1052-8482 Europe, Africa and Middle East John Deere Power Systems Usine de Saran La Foulonnerie -B.P. 11013 45401 Fleury-les-Aubrais Cedex - France Phone (33) 2 38 82 61 19 FAX (33) 2 38 82 60 00 [email protected] Central America, South America and Caribbean Tradewinds Power Corp. 5820 NW 84th Avenue Miami, FL 33166 Phone 305-592-9745 FAX 305-592-7461 Argentina Industrias John Deere Argentina, S.A. Juan Orsetti 481 2152 Grandero Baigorria Sante Fe, Argentina Phone 54-341-471-8000 FAX 54-341-471-8001 Australia and New Zealand John Deere Limited, Power Systems Division 49 Smeaton Grange Road Narellan NSW 2567 Australia Phone 612 46474857 FAX 612 46461236 Far East John Deere Asia Ltd Suite 903, 9th Floor Lippo Sun Plaza, 28 Canton Road Tsim Sha Tsui, Kowloon, Hong Kong Phone 852 3105 0818 FAX 852 3105 0331 www.JohnDeere.com/gendrive [email protected] DSWT39 Litho in U.S.A. (05-11) © 2005 JOHN DEERE Generator Drive Diesel Engine Ratings Contents Engine Identification........................................2–3 Features and Benefits .....................................4–5 Generator Drive Engines Non-Regulated PowerTech..........................6–9 Tier 1 PowerTech .....................................10–11 Tier 2 PowerTech .....................................12–13 Tier 3 PowerTech E Tier 3 PowerTech Plus.............................14–15 Conversions........................................................16 Identification Plate Factory Manufactured by: RG Waterloo, IA CD Saran, France PE Torreon, Mexico *RG 6135 H 123456* JOHN DEERE Engine Serial Number *RG6135H123456* Number of Cylinders and Total Displacement 6135 6 Cylinders, 13.5 Liters 6125 6 Cylinders, 12.5 Liters 6090 6 Cylinders, 9.0 Liters 6081 6 Cylinders, 8.1 Liters 6068 6 Cylinders, 6.8 Liters 4045 4 Cylinders, 4.5 Liters 5030 5 Cylinders, 3.0 Liters 3029 3 Cylinders, 2.9 Liters 4024 4 Cylinders, 2.4 Liters Air Intake System D Naturally Aspirated T Turbocharged A Turbocharged and Aftercooled, Air-to-Water H Turbocharged and Aftercooled, Air-to-Air Engine Serial Number RG6135HF485 DEERE & COMPANY MOLINE, ILLINOIS MADE IN USA RG 6 135 H F 485 Engine Controls (Tier 3/Stage III A) 0 Mechanical Controls 5 Electronic Controls Emissions Certification 001 Tier 1/Stage I 070 Tier 2/Stage II 8 Tier 3/Stage III A 9 Interim Tier 4/Stage III B Model Designation Key Below is a key for the engine models shown in this guide. A model designated as 6135H is a 6-cylinder, 13.5 liter turbocharged and aftercooled, air-to-air engine. A model designated as a 4045T is a 4-cylinder, 4.5 liter turbocharged engine. Valves Per Cylinder (Tier 3/Stage III A) 2 2-Valves 4 4-Valves User Type F OEM (John Deere Power Systems) XX Other letters are used to identify John Deere Equipment Manufacturing Locations 613 5 H Indicates Air Intake System Displacement in Liters Number of Cylinders 2 3 Features and Benefits Standby and Prime John Deere Generator Drive Engines for Standby and Prime Applications Power Density Options and accessories • Best-in-class power density – Standby: 4.5L, 6.8L, 12.5L, and 13.5L – Prime: 4.5L, 6.8L, 12.5L, and 13.5L • Competitive power density – Standby: 2.4L, 3.0L, 8.1L, and 9.0L – Prime: 2.4L, 3.0L, 8.1L, and 9.0L Emissions • Full EPA emissions-certified product range (2.4L–13.5L) • Non-certified engines also available for non-regulated markets 4 • • • • • • Oil pans, fuel filter sizes, and instrument panel types Cooling packages Air cleaner element types Optional auxiliary drive Wide range of fan speed ratios Either-side engine service User-friendly features • Low operating costs and low maintenance requirements • Exceptional block-loading response capabilities • Outstanding reliability and durability • Longer service intervals • Excellent cold starting • Low noise 5 TM Generator Drive Power Ratings 50 Hz Engine Model 6 Rated Speed Engine Power Prime Engine Power Standby Prime Ratings Standby Ratings Typical Generator Efficiency Typical Fan Power RPM kW hp kVA kWe kW hp kVA kWe % kW 3029D 1500 27 36 28-29 22-23 31 41 32-34 26-27 88-92 2.0 3029T 1500 38 51 40-41 32-33 42 56 44-46 35-37 88-92 2.0 4024T 4024T 1500 1500 19 28 25 38 20 30 16 24 21 31 28 42 23 34 18 27 88 88 0.1 1.0 4045D 4045T 4045T 4045T 4045T 4045H 4045H 4045H 1500 1500 1500 1500 1500 1500 1500 1500 40 56 63 63 75 72 91 109 54 75 84 84 101 96 122 146 41-44 59-62 65-68 66-70 79-83 76-80 96-100 112-118 33-35 47-50 52-54 53-55 63-66 61-64 77-80 90-94 44 62 70 70 83 80 102 120 59 83 94 94 111 107 137 161 46-49 66-69 73-76 74-78 88-92 85-89 108-113 125-131 37-39 53-55 58-61 59-62 70-74 68-71 86-90 100-104 88-92 88-92 88-92 88-92 88-92 88-92 88-92 88-92 2.0 2.0 3.5 2.5 4.8 3.0 4.0 6.0 5030T 5030H 1500 1500 38 56 50 75 40 60 32 48 42 62 56 84 45 66 36 53 88 88 1.3 1.9 6068T 6068T 6068T 6068T 6068H 6068H 6068H 6068H 1500 1500 1500 1500 1500 1500 1500 1500 85 94 95 109 111 140 166 188 114 126 127 146 149 188 223 252 90-94 100-104 100-105 115-121 117-123 148-155 175-183 195-204 72-75 80-83 80-84 92-97 94-98 118-124 156-163 156-163 94 104 105 121 123 155 183 207 126 139 141 162 165 208 245 278 100-104 110-116 111-116 129-135 130-136 165-172 194-202 216-226 80-83 88-93 89-93 103-108 104-109 132-138 155-162 173-181 88-92 88-92 88-92 88-92 88-92 88-92 88-92 88-92 3.5 3.5 3.5 4.0 4.5 5.5 6.5 10.4 6081T 6081T 6081A 6081A 6081A 6081H 6081H 1500 1500 1500 1500 1500 1500 1500 119 144 142 168 192 182 231 160 193 190 225 257 244 310 125-131 152-159 150-157 178-186 202-212 192-201 244-255 100-105 121-127 120-126 142-149 162-169 154-161 195-204 131 169 157 187 225 200 268 175 227 210 250 302 268 359 139-145 179-187 166-174 199-207 239-250 212-222 284-297 111-116 143-150 133-139 159-166 191-200 170-178 227-238 88-92 88-92 88-92 88-92 88-92 88-92 88-92 4.5 6.0 5.5 6.5 8.0 7.0 9.5 6125H 6125H 6125H 6125H 6125H 1500 1500 1500 1500 1500 275 273 318 320 350 368 366 427 429 469 291-304 288-302 337-352 339-354 370-388 233-243 231-241 269-281 271-283 296-310 302 300 350 352 387 405 402 469 472 519 320-335 318-333 372-388 374-390 411-429 256-268 255-266 297-311 299-312 329-344 88-92 88-92 88-92 88-92 88-92 10.5 10.5 12.3 12.5 13.5 All ratings are subject to change. Non-Regulated PowerTech Non-regulated PowerTech 7 TM Generator Drive Power Ratings 60 Hz Engine Model 8 Rated Speed Engine Power Prime RPM kW 3029D 1800 4045T 1800 All ratings are subject to change. Prime Ratings Engine Power Standby kW hp kVA kWe 31 42 31-33 25-26 35 90 121 94-98 75-78 100 hp Standby Ratings Typical Generator Efficiency Typical Fan Power kVA kWe % kW 47 35-37 28-30 88-92 3.0 134 104-109 83-87 88-92 4.8 Non-Regulated PowerTech Non-regulated PowerTech 9 Tier 1 PowerTech TM Engine Model 10 Rated Speed Engine Power Prime Prime Ratings Engine Power Standby Standby Ratings Typical Generator Efficiency Typical Fan Power RPM kW hp kVA kWe kW hp kVA kWe % kW 3029T 1800 43 58 44-46 35-37 48 64 49-51 39-41 88-92 3.0 4045D 4045T 4045T 4045T 4045T 4045T 4045H 4045H 1800 1800 1800 1800 1800 1800 1800 1800 48 67 74 76 82 90 86 111 64 90 99 102 110 121 115 149 50-52 70-73 76-80 79-82 85-89 94-98 89-93 115-120 40-42 56-58 61-64 63-66 68-71 75-78 71-74 92-96 53 74 82 84 91 100 95 123 71 99 110 113 122 134 127 165 55-58 78-81 85-90 88-92 95-100 105-109 99-104 129-134 44-46 62-65 68-72 70-74 76-80 84-87 79-83 103-107 88-92 88-92 88-92 88-92 88-92 88-92 88-92 88-92 2.6 3.7 4.1 4.1 4.5 5.0 4.8 6.0 6068T 6068T 6068T 6068T 6068H 6068H 6068H 1800 1800 1800 1800 1800 1800 1800 101 111 112 128 133 168 189 135 149 150 172 178 225 253 105-110 115-120 116-121 132-139 137-144 174-182 196-205 84-88 92-96 93-97 106-111 110-115 139-146 157-164 112 123 124 142 148 187 210 150 165 166 190 198 251 282 116-122 129-134 129-135 148-155 154-161 195-204 220-230 93-98 103-107 103-108 118-124 123-129 156-163 176-184 88-92 88-92 88-92 88-92 88-92 88-92 88-92 5.6 6.3 6.3 7.1 7.5 9.3 10.4 6081T 6081T 6081A 6081A 6081A 6081H 6081H 1800 1800 1800 1800 1800 1800 1800 142 166 168 201 220 218 263 190 223 225 270 295 292 353 147-154 172-180 174-182 209-219 228-238 226-236 273-285 118-123 138-144 139-146 167-175 182-190 181-189 218-228 157 194 187 224 259 240 308 211 260 250 300 347 322 413 164-172 202-211 195-204 234-244 270-282 251-262 322-336 131-138 162-169 156-163 187-195 216-226 201-210 258-269 88-92 88-92 88-92 88-92 88-92 88-92 88-92 7.8 9.5 9.3 11.2 13.0 11.9 15.3 6125A 6125H 6125H 1800 1800 1800 300 327 382 402 439 512 311-326 340-356 397-415 249-261 272-285 318-332 6125H 1800 418 561 404-421 323-337 330 360 420 460 442 483 563 617 344-360 376-394 439-459 491-514 275-288 301-315 351-367 393-411 88-92 88-92 88-92 90-94 16.4 17.9 20.9 23.1 All ratings are subject to change. Tier 1 PowerTech Generator Drive Power Ratings 60 Hz 11 Tier 2 PowerTech TM Engine Model 12 Rated Speed Engine Power Prime Engine Power Standby Prime Ratings Standby Ratings Typical Generator Efficiency Typical Fan Power RPM kW hp kVA kWe kW hp kVA kWe % kW 3029T 1800 44 59 46-48 37-38 48 64 50-52 40-42 88-92 2.4 4024T 1800 32 43 34 27 36 48 38 30 88 1.8 4045D 4045T 4045T 4045H 4045H 4045H 1800 1800 1800 1800 1800 1800 46 67 76 98 106 130 62 90 102 131 142 174 48-50 70-73 79-83 102-107 109-115 134-141 38-40 56-58 64-66 82-85 87-92 107-112 50 74 84 108 117 143 67 99 113 145 157 192 52-55 77-81 88-92 113-118 121-128 148-156 42-44 62-65 70-73 90-94 97-102 119-124 88-92 88-92 88-92 88-92 88-92 88-92 2.5 3.7 4.2 5.4 5.9 7.2 5030T 5030H 1800 1800 54 65 72 87 56 68 45 54 60 72 80 96 63 75 50 60 88 88 3.0 3.6 6068T 6068H 6068H 6068H 6068H 1800 1800 1800 1800 1800 112 149 170 191 213 150 200 228 256 286 116-122 155-162 177-185 198-207 221-231 93-97 124-130 141-148 159-166 177-185 123 164 187 210 234 165 220 250 282 314 129-134 171-179 195-204 219-229 245-256 103-108 137-143 156-163 176-184 196-205 88-92 88-92 88-92 88-92 88-92 6.2 8.2 9.4 10.5 11.7 6081H 6081H 6081H 6081H 1800 1800 1800 1800 210 236 263 289 282 317 352 388 226-236 254-266 283-295 311-325 181-189 203-212 226-236 249-260 231 260 289 318 310 349 388 426 249-261 281-293 312-326 343-359 200-208 225-235 250-261 275-287 90-94 90-94 90-94 90-94 11.6 13.0 14.5 15.9 6125H 6125H 6125H 6125H 1800 1800 1800 1800 300 327 382 418 402 439 512 561 312-326 340-356 397-415 435-454 249-261 272-285 318-332 348-364 330 360 420 460 442 483 563 617 345-361 376-394 439-459 481-503 276-288 301-315 351-367 385-402 88-92 88-92 88-92 88-92 16.4 17.9 20.9 23.0 All ratings are subject to change. Tier 2 PowerTech Generator Drive Power Ratings 60 Hz 13 TM Generator Drive Power Ratings 60 Hz Engine Model Rated Speed Engine Power Prime Engine Power Standby Prime Ratings Standby Ratings Typical Generator Efficiency Typical Fan Power RPM kW hp kVA kWe kW hp kVA kWe % kW 6068H 1800 214 286 226 181 235 315 250 200 90 12.9 6090H 6090H 6090H 6090H 6090H* 1800 1800 1800 1800 1800 208 235 261 287 311 279 315 350 384 417 226 255 284 312 338 181 204 227 249 271 229 258 287 315 344 307 346 385 422 461 250 281 312 344 375 200 225 250 275 300 92 92 92 92 92 12.6 14.2 15.8 17.3 18.9 6135H 6135H 6135H* 1800 1800 1800 365 419 466 489 561 624 397 455 508 317 364 407 401 460 516 538 617 691 438 500 562 350 400 450 92 92 92 22.1 25.3 28.4 Typical Generator Efficiency Typical Fan Power Tier 3 PowerTech Plus & PowerTech E Tier 3 PowerTech Plus Tier 3 PowerTech E TM Generator Drive Power Ratings 60 Hz Engine Model Rated Speed Engine Power Prime RPM kW Engine Power Standby Prime Ratings hp kVA kWe kW hp Standby Ratings kVA kWe % kW 4045T* 1800 63 85 67 54 70 94 75 60 90 3.9 4045H* 1800 85 114 90 72 94 126 100 80 90 5.2 4045H* 1800 105 142 112 90 117 157 125 100 90 6.4 6068H 6068H 1800 1800 134 161 180 216 141 169 113 135 147 177 197 237 156 186 125 149 90 90 8.0 11.0 *Preliminary data, ratings are subject to change. 14 All ratings are subject to change. 15 Conversions Customer Support Brake Horsepower (BHP) BHP = ______________ RPM x Torque With more than 4,000 service locations worldwide, John Deere is always handy when you need service and support. You’ll find an authorized John Deere dealer or engine distributor almost anywhere in the world. 5252 Torque Torque =____________ BHP x 5252 RPM Fuel Consumption Gal/hr =_____________ BHP x BSFC 7.2 lbs/gal Generator Drive Rating (kWe) kWe = [Engine Power (kW) Fan Power Loss (kW)] x Generator Efficiency Power Factor (PF) PF = kWe/kVA = ___________ Real Power Apparent Power PF Constant = 0.80 English to Metric Newton-meter = lb-ft x 1.356 Newton = lb force x 4.448 Meter = ft x 0.3048 Millimeter = in x 25.4 Kilogram = lb x 0.454 Liter = gal x 3.785 Liter = cu in x 0.01639 Kilowatt = hp x 0.746 x amps)) (Kilowatt = (volts 1000 Celsius = (deg F-32) x 0.556 16 We have centralized parts warehouses in the United States and Europe, plus numerous worldwide depots that employ overnight parts shipping—so you’ll never have to wait long for parts. In addition, John Deere service personnel are highly trained technicians who stay on top of changing engine technologies and service techniques. John Deere dealers and distributors are your best source for service, knowledge, and engine accessories. They’re one of the many reasons to specify John Deere engines in your generator sets.
© Copyright 2026 Paperzz