Diaphragm Pumps Operating and Installation Instructions Read and observe these Operating and Installation Instructions! N 1200 A_E N 1200 AN.9E N 1200 S_E N 1200 ST.9E N 1400.1 A_E N 1400.3 A_E N 1400.1 S_E N 1400.3 S_E N 1400.2 A_E N 1400.2 AN.9E N 1400.2 S_E N 1400.2 AT.9E N 1400.1.2 A_E N 1400.2 SV.9E N 1400.1.2 S_E Contents KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Germany Phone +49-(0)7664-5909-0 Fax +49-(0)7664-5909-99 E-mail: [email protected] www.knf.de 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Page About this document................................................................. 2 Use ........................................................................................... 3 Safety ....................................................................................... 4 Technical Data ......................................................................... 6 Design and function .................................................................. 8 Installation and connection ..................................................... 14 Operation ................................................................................ 18 Servicing ................................................................................. 20 Troubleshooting ...................................................................... 28 Spare parts and accessories .................................................. 30 Decontamination declaration .................................................. 32 KNF 120845-121497 07/13 Translation of original Operating and Installation Instructions, english Keep for future use! About this document Diaphragm Pumps N 1200/1400 1. About this document 1.1. Using the Operating and Installation Instructions The Operating and Installation Instructions are part of the pump. Pass on the Operating and Installation Instructions to the next owner. Compliance with the Operating and Installation Instructions is essential for the safe and reliable operation of the pump. Failure to do so may result in severe or potentially lifethreatening injury and/or serious damage. Project pumps Customer-specific project pumps (pump models which begin with "PJ" or "PM") may differ from the Operating and Installation Instructions. For project pumps, also observe the agreed upon specifications. 1.2. Symbols and markings Warning A danger warning is located here. Possible consequences of a failure to observe the warning are specified here. The signal word, e.g. WARNING Warning, indicates the danger level. Measures for avoiding the danger and its consequences are specified here. Danger levels Signal word Meaning warns of immediDANGER ate danger WARNING CAUTION Consequences if not observed Death or serious injuries and/or serious damage are the consequence. warns of possible Death or serious injuries danger and/or serious damage are possible. warns of a possibly Minor injuries or damage are dangerous situapossible. tion Tab. 1 Other information and symbols An activity to be carried out (a step) is specified here. 1. The first step of an activity to be carried out is specified here. Additional, consecutively numbered steps follow. This symbol refers to important information. 2 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Use 2. Use 2.1. Proper use The pumps are exclusively intended for transferring gases and vapors. Owner's responsibility Operating parameters and conditions Only install and operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Protect the compressors with a pressure relief device between the pressure side of the compressor and the first shut-off valve. Only complete pumps may be taken into service. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The gas-tightness of the connections between the application pipes and the pump (or the pump connection) must be checked regularly; with leaky connections, there is a danger that hazardous gases or vapors may escape from the pump system. Requirements for transferred medium Before using a medium, check whether the medium can be transferred danger-free in the specific application case. Before using a medium, check the compatibility of the materials of the pump head, diaphragm and valves with the medium. Only transfer gases which remain stable under the pressures and temperatures occurring in the pump. 2.2. Improper use The pumps may not be operated in an explosive atmosphere. The pumps are not suitable for transferring liquids. The pumps are not suitable for transferring dusts. Pumps designed to create either a vacuum or an overpressure must not be used for these two purposes simultaneously. An overpressure must not be applied to the suction side of the pump. Pumps with three-phase motor are not provided for the operation with frequency converter. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 3 Safety Diaphragm Pumps N 1200/1400 3. Safety Note the safety precautions in chapters 6. Installation and connection, and 7. Operation. The pumps are built according to the generally recognized rules of technology and in accordance with the occupational safety and accident prevention regulations. Nevertheless, dangers can result during their use which lead to injuries to the user or others, or to damage to the pump or other property. Only use the pumps when they are in a good technical and proper working order, in accordance with their intended use, observing the safety advice within the operating and installation instructions, at all times. Personnel Make sure that only trained and instructed personnel or specially trained personnel work on the pumps. This especially applies to assembly, connection and servicing work. Make sure that the personnel has read and understood the operating and installation instructions, and in particular the "Safety" chapter. Working in a safetyconscious manner Observe the accident prevention and safety regulations when performing any work on the pump and during operation. The pump heads heat up during operation – avoid contact with them. Handling dangerous media Handling combustible media When transferring dangerous media, observe the safety regulations when handling these media. Be aware that the pumps are not designed to be explosion-proof. Make sure the temperature of the medium is always sufficiently below the ignition temperature of the medium, to avoid ignition or explosion. This also applies for unusual operational situations. Note that the temperature of the medium increases when the pump compresses the medium (compressor operation). Hence, make sure the temperature of the medium is sufficiently below the ignition temperature of the medium, even when it is compressed to the maximum permissible operating pressure of the pump. The maximum permissible operating pressure of the pump is stated in the technical specifications (chapter 4). If necessary, consider any external sources of energy, such as radiation, that may add heat to the medium. In case of doubt, consult the KNF customer service. 4 Environmental protection Store all replacement parts in a protected manner and dispose of them properly in accordance with the applicable environmental protection regulations. Observe the respective national and international regulations. This especially applies to parts contaminated with toxic substances. EC Directives / Standards For the purposes of the Machinery Directive 2006/42/EC, pumps are “partly completed machinery,” and are therefore to be regarded as not ready for use. Partly completed machinery may not be commissioned until such time as it has been determined that the machine in which the partly completed machinery is to be Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Safety assembled is in conformity with the provisions of the Machinery Directive 2006/42/EC. The following essential requirements of Annex I of Directive 2006/42/EC (general principles) are applied and observed: − − General Principles No. 1 No. 1.1.2. / 1.1.3. / 1.3.1. / 1.3.3. / 1.3.4. / 1.4.1. / 1.5.1. / 1.5.2. / 1.5.8. / 1.5.9. / 1.7.4. / 1.7.4.1. / 1.7.4.3. As these partly completed machinery are OEM-models the power supplies and the equipment for disconnecting and switching-off the partly completed machinery respectively have to be considered when mounting as well as over-current and overload protective gear. In addition a protection against mechanical parts in motion and hot parts, if existing, has to be provided when mounting. The pumps conform to the Directive 2011/65/EU (RoHS2). The pumps conform to the EC Directive 2004/108/EC concerning Electromagnetic Compatibility. The following harmonized standards have been used: Customer service and repairs DIN EN 55014-1/2 DIN EN 61000-3-2/3 DIN EN 60204-1 Only have repairs to the pumps carried out by the KNF Customer Service responsible. Use only genuine parts from KNF for servicing work. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 5 Technical Data Diaphragm Pumps N 1200/1400 4. Technical Data Pump materials Pump type N 1200 ANE N 1400._ANE N 1200 ATE N 1400._ATE N 1200 AVE N 1400._AVE N 1200 SNE N 1400._SNE N 1200 STE N 1400._STE N 1200 SVE N 1400._SVE Material Pump head Diaphragm Valve G-AlSi10Mg EPDM Stainless Steel 1.4310 G-AlSi10Mg PTFE-coated Stainless Steel 1.4310 G-AlSi10Mg FPM Stainless Steel 1.4310 Stainless Steel 1.4571 EPDM Stainless Steel 1.4310 Stainless Steel 1.4571 PTFE- coated Stainless Steel 1.4310 Stainless Steel 1.4571 FPM Stainless Steel 1.4310 Tab. 2 Pneumatic Performance Pump type N 1200 A_E N 1200 S_E N 1400.1 A_E N 1400.1 S_E N 1400.2 A_E N 1400.2 S_E N 1400.1.2 A_E N 1400.1.2 S_E N 1400.3 A_E N 1400.3 S_E Delivery* (l/min) at atm. pressure ** Maximum permissible operating pressure (bar g) Ultimate vacuum (mbar abs.) 150 6 100 300 - 100 300 6 - 300 - 100 150 - 20 Tab. 3 *Liters in standard state (1,013 mbar) **Pumps with PTFE- coated diaphragms: Delivery is about 85 %. Pneumatic Connections Pump type N 1200 A_E N 1200 S_E N 1400.1 A_E N 1400.1 S_E N 1400.2 A_E N 1400.2 S_E N 1400.3 A_E N 1400.3 S_E N 1400.1.2 A_E N 1400.1.2 S_E Suction side Pressure side Thread size M18x1,5 Thread size M22x1,5 Ø 15 Thread size M18x1,5 Ø 18 Thread size M22x1,5 Thread size M18x1,5 Ø 15 Thread size M22x1,5 Ø 18 Thread size M18x1,5 Thread size M18x1,5 Thread size M22x1,5 Thread size M22x1,5 Ø 15 Ø 18 Tab. 4 6 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Technical Data Electrical Data Parameter Electrical Data Value See type plate Tab. 5 Thermal-switch The pumps with capacitor motor are fitted as standard with a thermal-switch to protect against overloading. Weight Pump type N 1200 A_E N 1200 S_E N 1400 A_E N 1400 S_E Weight (kg) approx. 30,0 approx. 36,0 approx. 35,0 approx. 47,0 Tab. 6 Dimensions Pump type N 1200 A_E N 1200 S_E N 1400.1 A_E and N 1400.3 A_E N 1400.1 S_E N 1400.3 S_E N 1400.2 A_E and N 1400.1.2 A_E N 1400.2 S_E and N 1400.1.2 S_E Dimensions L x H x W [mm] 470 / 320 / 210 470 / 287 / 210 590 / 300 / 350 585 / 307 / 379 585 / 307 / 373 625 / 300 / 350 607 / 307 / 379 Tab. 7 Other parameters Parameter Permissible ambient temperature Value + 5 °C to + 40 °C Permissible media temperature + 5 °C to + 40 °C Maximum permissible ambient relative humidity 80 % for temperatures up to 31 °C, decreasing linearly to 50 % at 40 °C Max. altitude of site [m above sea level] Gas-tightness* of pump head/ heads (leak rate) (not tested) For .9 versions: Gas-tightness* of pump head/ heads (leak rate) 2000 approx. 6 x 10-3 mbar l/s < 6 x 10-3 mbar l/s Tab. 8 * After opening the pump head or the pump heads, or replacing the diaphragm(s) and reed valves the gas tightness is no longer guaranteed. A leak test is able to verify that the original standard of gas-tightness has been achieved. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 7 Design and function Diaphragm Pumps N 1200/1400 5. Design and function Design N 1200 A_E 1 2 3 4 5 Pneumatic pump inlet (M18x1,5) Terminal box (electrical connection) Motor Fan cover Pneumatic pump outlet (M18x1,5) Fig. 1: Diaphragm pump N 1200 A_E Design N 1200 S_E 1 2 3 4 5 Pneumatic pump outlet (M22x1,5) Pneumatic pump inlet (M22x1,5) Terminal box (electrical connection) Motor Fan cover Fig. 2: Diaphragm pump N 1200 S_E 8 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Design and function Design N 1400.1 A_E 1 2 3 4 5 6 7 Union nut Pneumatic head connection Pneumatic pump inlet (Ø 15) Terminal box (electrical connection) Motor Fan cover Pneumatic pump outlet (M18x1,5) Fig. 3: Diaphragm pump N 1400.1 A_E Design N 1400.1 S_E 1 2 3 4 5 6 7 Pneumatic pump outlet (M22x1,5) Pneumatic head connection Terminal box (electrical connection) Pneumatic pump inlet (Ø 18) Motor Fan cover Union nut Fig. 4: Diaphragm pump N 1400.1 S_E Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 9 Design and function Diaphragm Pumps N 1200/1400 Design N 1400.2 A_E 1 2 3 4 5 6 7 Pneumatic pump inlet (M18x1,5) Union nut Terminal box(electrical connection) Motor Fan cover Pneumatic pump outlet (Ø 15) Pneumatic head connection Fig. 5: Diaphragm pump N 1400.2 A_E Design N 1400.2 S_E 1 2 3 4 5 6 7 Union nut Pneumatic pump inlet (M22x1,5) Terminal box (electrical connection) Motor Fan cover Pneumatic pump outlet (Ø 18) Pneumatic head connection Fig. 6: Diaphragm pump N 1400.2 S_E 10 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Design and function Aufbau N 1400.1.2 A_E 1 2 3 4 5 6 7 Union nut Pneumatic head connection Pneumatic pump inlet (Ø 15) Terminal box (electrical connection) Motor Fan cover Pneumatic pump outlet (Ø 15) Fig. 7: Diaphragm pump N 1400.1.2 A_E Aufbau N 1400.1.2 S_E 1 2 3 4 5 6 7 Union nut Pneumatic head connection Terminal box (electrical connection) Pneumatic pump inlet (Ø 18) Fan cover Motor Pneumatic pump outlet (Ø 18) Fig. 8: Diaphragm pump N 1400.1.2 S_E Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 11 Design and function Diaphragm Pumps N 1200/1400 Aufbau N 1400.3 A_E 1 2 3 4 5 6 7 Union nut Pneumatic head connection Terminal box (electrical connection) Motor Fan cover Pneumatic pump inlet (M18x1,5) Pneumatic pump outlet (M18x1,5) Fig. 9: Diaphragm pump N 1400.3 A_E Aufbau N 1400.3 S_E 1 2 3 4 5 6 7 Union nut Pneumatic head connection Terminal box (electrical connection) Motor Fan cover Pneumatic pump inlet (M22x1,5) Pneumatic pump outlet (M22x1,5) Fig. 10: Diaphragm pump N 1400.3 S_E 12 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Design and function Function Diaphragm Pump 1 2 3 4 5 6 7 Outlet valve Inlet valve Transfer chamber Diaphragm Eccentric Connecting rod Pump drive Fig. 11: Pump headf Diaphragm pumps transfer, compress (depending on pump version) and evacuate gases and vapors. The elastic diaphragm (4) is moved up and down by the eccentric (5) and the connecting rod (6). In the downward stroke it aspirates the gas to be transferred via the inlet valve (2). In the upward stroke, the diaphragm presses the medium out of the pump head via the outlet valve (1). The transfer chamber (3) is hermetically separated from the pump drive (7) by the diaphragm. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 13 Installation and connection Diaphragm Pumps N 1200/1400 6. Installation and connection Only install the pumps under the operating parameters and conditions described in chapter 4, Technical data. Observe the safety precautions (see chapter 3). 6.1. Installation of the pump Before installation, store the pump at the installation location to bring it up to ambient temperature. Mounting dimensions See Fig. 12 (pump series N 1200__E), Fig. 13 (pump series N 1400.1__E and N 1400.3__E) or Fig. 14 (pump series N1400.2__E and N 1400.1.2__E) for the mounting dimensions. The mounting dimensions differ between pumps with cast heads and pumps with smooth heads (turned part) (see chapter 4, Technical Data). * bei N1200 S_E: M 22 x 1,5 Fig. 12: Mounting dimensions pump series N 1200__E (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) * bei N 1400.1S_E und N 1400.3S_E: M 22 x 1,5 Fig. 13: Mounting dimensions pump series N 1400.1__E and N 1400.3__E (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) 14 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Installation and connection * bei N 1400.2 S_E: M22 x 1,5 Fig. 14: Mounting dimensions pump series N 1400.2__E and N 1400.1.2__E (All dimensional tolerances conform to DIN ISO 2768-1, Tolerance Class V) Cooling air supply Installation location Install the pump so that the motor fan can intake sufficient cooling air. Make sure that the installation location is dry and the pump is protected against rain, splash, hose and drip water. The IP protection class of the pump motor is indicated on the type plate. Install the pump at the highest point in the system to prevent condensate from collecting in the pump head. Protect the pump from dust. Protect the pump from vibrations and jolts. Disengaging KNF recommends mechanically disengaging the pump from the piping system. This can be achieved with flexible tubing or pipes, for example. This will avoid transferring to the system any pump oscillations that may arise. 6.2. Electrical connection Extreme danger from electrical shock Only have the pump connected by an authorized specialist. GEFAHR Only have the pump connected when the power supply is disconnected. When connecting the device to a power source, the relevant standards, directives, regulations, and technical standards must be observed. In the electrical installation, arrangements (complying with EN 60335-1) must be made for disconnecting the pump motor from the electrical supply. The motors of the pump must be protected according to EN 60204-1 (protection against excess current, or overloading). For operating current see type plate. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 15 Installation and connection Diaphragm Pumps N 1200/1400 It is recommended that an additional “Emergency Stop” switch is installed. The pump must be installed so that contact with live parts (electrical connection) is impossible. Connecting pump 1. Compare the supply data with the data on the motor-plate. For operating current see type plate. The voltage must not vary by more than + 10% and - 10% from that shown on the type-plate. 2. Open terminal box cover. 3. All pumps except versions with 3 phase motor: Connect the mains cables to the connections L1 and N of the pump motor. 4. Connection of pumps with 3 phase motor according to Fig. 15 or Fig. 16. 5. Connect the earth (ground) wire to the motor. 6. Close the terminal cover box. Fig. 15: Y-Connection (high voltage) Fig. 16: ∆-Connection (low voltage) 16 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Installation and connection 6.3. Pneumatic connection Connected components Pressure relief device Pump exhaust Only connect components to the pump which are designed for the pneumatic data of the pump (see chapter 4, Technical data). Protect the compressors with a pressure relief device between the pressure side of the compressor and the first shut-off valve. If the pump is used as a vacuum pump, safely discharge the pump exhaust at the pump’s pneumatic outlet. Connecting pump A marking on the pump head shows the direction of flow. 1. Remove the protective plugs from the hose connection threads. 2. Connect the suction line and pressure line (see chapter 4, table 6 for the mounting dimensions). 3. Lay the suction and pressure line at a downward angle to prevent condensate from running into the pump. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 17 Operation Diaphragm Pumps N 1200/1400 7. Operation Only operate the pumps under the operating parameters and conditions described in chapter 4, Technical data. Make sure the pumps are used properly (see chapter 2.1). Make sure the pumps are not used improperly (see chapter 2.2). Observe the safety precautions (see chapter 3). The pumps are intended for installation. Before putting them into service it must be established that machinery or equipment in which they are installed meets the relevant regulations. Hazard of the pump head bursting due to excessive pressure increase Do not exceed max. permissible operating pressure (see chapter 4, Technical data). WARNING Monitor pressure during operation. If the pressure exceeds the maximum permissible operating pressure, immediately switch off pump and eliminate fault (see chapter 9. Troubleshooting). Only throttle or regulate the air or gas quantity in the suction line to prevent the maximum permissible operating pressure from being exceeded. If the air or gas quantity in the pressure line is throttled or regulated, make sure that the maximum permissible operating pressure is not exceeded. Ensure that the pump outlet is not closed or constricted. Excessive pressure (with all of the related hazards) can be prevented by placing a bypass line with a pressure-relief valve between the pressure and suctions sides of the pump. For further information, contact our technical adviser (see front page for telephone number). Automatic starting can cause personal injury and pump damage When the operation of the pump is interrupted by the WARNING thermal switch, the pump will restart automatically after cooling down. Take all necessary care to prevent this leading to a dangerous situation. Pump standstill 18 With the pump at a standstill, open pressure and suction lines to normal atmospheric pressure. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Operation The pump may not start up against pressure or vacuum during switch-on. This also applies in operation following a brief power failure. If a pump starts against pressure or vacuum, it may block. This activates the thermal switch, and the pump switches off. Make sure that normal atmospheric pressure is present in the lines during switch-on. Vapors as media The life of the diaphragm is prolonged if the formation of condensate is avoided. Therefore the following precautions should be taken: Run the pump for a few minutes to warm it up before handling saturated or nearly saturated vapours. KNF recommends: When transferring aggressive media, flush the pump prior to switch-off (see chapter 8.2.1) to increase the service life of the diaphragm. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 19 Servicing Diaphragm Pumps N 1200/1400 8. Servicing 8.1. Servicing schedule Component Pump Servicing interval - Regular inspection for external damage or leaks Tube connection - Regular inspection for external damage or leaks Diaphragm and reed - Replace if bent or worn valves - Replace at the latest, when pump output decreases Tab. 9 8.2. Cleaning 8.2.1. Flushing pump KNF recommends: When transferring aggressive media, flush the pump under atmospheric conditions some minutes with air (or, if necessary for safety reasons, with an inert gas) prior to switch-off to increase the service life of the diaphragm. 8.2.2. Cleaning pump Only use solvents for cleaning if the head materials cannot be attacked (check the resistance of the material). If compressed air is available, blow out the components. 8.3. Replacing diaphragm, reed valves and sealings 8.3.1. Pump types with stainless steel heads For .9 versions (increased gas-tightness) see b) in this chapter. a) Type range N1200 S_E N1400 S_E Conditions Motor disconnected from mains and de-energizedi Pump clean and free of dangerous substances Tubes/pipes removed from pump’s pneumatic inlet and outlet Information on procedure Health hazard due to dangerous substances in the pump! Depending on the substance transferred, caustic WARNUNG burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. 20 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Servicing For two-headed pumps: In principle, the maintenance work on both heads should be carried out at the same time. With multi-head pumps, parts of the individual pump heads can be confused. Replace diaphragm and reed valves of the individual pump heads consecutively. Spare parts Spare part* Diaphragm Position** (B) Cross recessed countersunk head screw O-Ring (G) (M) Reed valves (L/N) (L) and (N) Tab. 10 Tools and material Quantity 1 1 1 1 1 1 1 Tab. 11 Quantity 1 (per pump head) 3 (per pump head) 2 (per pump head) 2 (per pump head) * according to spare parts list, chapter 10 ** According to Fig. 17 Tools/Material* Allen key 5 with torque indicator Phillips screwdriver No. 2 Screwdriver blade width 4.5 mm Screwdriver blade width 5.5 mm Fork wrench 30 mm Fork wrench 27 mm (for two-headed pumps only) Pencil * according to accessories list, chapter 10 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 21 Servicing Diaphragm Pumps N 1200/1400 Housing Diaphragm Intermediate plate Head Hexagon socket head cap screw (F) Retainer plate (G) Cross recessed countersunk head screw (not .9-pump types) (H) Connecting rod (J) Slotted cheese head screw (K) Slotted cheese head screw (L) Reed valve (M) O-Ring (N) Reed valve (A) (B) (C) (D) (E) Fig. 17: Pump parts (Stainless steel version) The following item terms refer to Fig. 17, unless otherwise indicated. Removing pump head 1. Take the steps necessary to gain access to the motor cooling fan: Undo the screws that hold the fan cover (Fig. 2/5, p. 8 or Fig. 4/6, p. 9, Fig. 6/5, p. 10, Fig. 8/5, p. 11 and Fig. 10/5, p. 12) and remove the fan cover. 2. Only for two-headed pumps: Remove the pneumatic connection (.3 models), or connections (.1, .2 or .1.2 models) between the pump heads, loosen the union nuts (Fig. 4/7, p. 9 or Fig. 6/1, p. 10, Fig. 8/1, p. 11 and Fig. 10/1, p. 12) to do so 3. Mark the position of housing (A), intermediate plate (C) and head (D) relative to each other by a drawing line with a pencil. This helps avoid incorrect assembly later. 4. Undo the six hexagon socket head cap screws (E); lift off head (D) and intermediate plate (C). 22 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Servicing 5. For two-headed pumps: Carry out steps 3 and 4 for the second pump head. Changing diaphragm 1. Undo the three cross recessed countersunk head screws (G). 2. Remove retainer plate (F) and diaphragm (B). 3. Inspect all parts for dirt and clean them if necessary. 4. Turn the fan until the connecting rod (H) is in mid-stroke. 5. Lay the retainer plate (F) on the new diaphragm (B); place the diaphragm with retainer plate on the connecting rod (H). 6. Tighten the three new cross recessed countersunk head screws (G) firmly. 7. For two-headed pumps: Carry out steps 1 to 6 for the second pump head. Changing reed valves 1. Remove the two O-rings (M) from the intermediate plate. 2. Undo the reed valves screws (J) and (K). 3. Inspect all parts for dirt and clean them if necessary. 4. Replace reed valves (L) and (N). 5. For two-headed pumps: Carry out steps 1 to 4 for the second pump head. Mounting pump head 1. Place intermediate plate (C) on housing (A) according to the mark made previously (at the same time, keep the diaphragm in its mid-position by holding the motor fan). 2. Fit the two new O-rings (M) in the intermediate plate (C). 3. Place head (D) on intermediate plate (C) according to the mark made previously. 4. Tighten the hexagon socket head cap screws (E) uniformly and diagonally (tightening torque: 14 Nm). 5. Turn the fan to check that the pump rotates freely. 6. Remount fan cover (Fig. 2/5, p. 8 or Fig. 4/6, p. 9, Fig. 6/5, p. 10, Fig. 8/5, p. 11 and Fig. 10/5, p. 12 ). 7. For two-headed pumps: Remount the pneumatic connection(s). b) .9 versions (increased gas tightness) In principle, maintenance is performed as described in a), but with the following exceptions: Cross recessed countersunk head screws (G) are not present Retainer plate (F) is removed and retightened with a wrench for retainer plate (see chapter 10, Spare parts and accessories). Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 23 Servicing Diaphragm Pumps N 1200/1400 Please ask KNF for the order numbers of spare parts (see last page for phone number) 8.3.2. Pump types with aluminium head For .9 versions (increased gas-tightness) see b) in this chapter. a) Type range N1200 A_E N1400 A_E Conditions Motor disconnected from mains and de-energizedi Pump clean and free of dangerous substances Tubes/pipes removed from pump’s pneumatic inlet and outlet Information on procedure Health hazard due to dangerous substances in the pump! Depending on the substance transferred, caustic WARNUNG burns or poisoning are possible. Wear protective clothing if necessary, e.g. protective gloves. Clean pump with suitable measures. For two-headed pumps: In principle, the maintenance work on both heads should be carried out at the same time. With multi-head pumps, parts of the individual pump heads can be confused. Replace diaphragm and reed valves of the individual pump heads consecutively. Spare parts Spare part* Diaphragm Position** (B) Sealing (D) Cross recessed countersunk head screw Reed valves (L/N) (M) Tab. 12 24 (L) and (N) Quantity 1 (per pump head) 1 (per pump head) 3 (per pump head) 2 (per pump head) * according to spare parts list, chapter 10 ** according to Fig. 18 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Tools and material Servicing Quantity 1 1 1 1 1 1 1 Tools/Material* Allen key 5 with torque indicator Phillips screwdriver No. 2 Screwdriver blade width 4.5 mm Screwdriver blade width 5.5 mm Fork wrench 30 mm Fork wrench 27 mm (for two-headed pumps only) Pencil Tab. 13 * according to accessories list, chapter 10 Housing Diaphragm Headf Sealing Cover plate Hexagon socket head cap screw (G) Hexagon socket head cap screw (H) Hexagon socket head cap screw (J) Slotted cheese head screw (K) Slotted cheese head screw (L) Reed valve (M) Cross recessed countersunk head screw (not .9-pump types) (N) Reed valve (P) Roll pin (R) Retainer plate (S) Connecting rod (A) (B) (C) (D) (E) (F) Fig. 18: Pump parts (aluminium version) The following item terms refer to Fig. 18, unless otherwise indicated. Removing pump head 1. Take the steps necessary to gain access to the motor cooling fan: Undo the screws that hold the fan cover (Fig. 1/4, p. 8 or Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 25 Servicing Diaphragm Pumps N 1200/1400 Fig. 3/6, p. 9, Fig. 5/5, p. 10, Fig. 7/6, p. 11 and Fig. 9/5, p.12) and remove the fan cover. 2. Only for two-headed pumps: Remove the pneumatic connection (.3 models), or connections (.1, .2 or .1.2 models) between the pump heads, loosen the union nuts (Fig. 3/1, p. 9 or Fig. 5/2, p. 10, Fig. 7/1, p. 11 and Fig. 9/1, p.12) to do so 3. Mark the position of housing (A) and head (C) relative to each other by a drawing line with a pencil. This helps avoid incorrect assembly later. 4. Undo the hexagon socket head cap screws (E) and (G) (two screws each) and lift off cover plate (E) and sealing (D) from housing. 5. Undo the hexagon socket head cap screws (H) (four screws) and lift off head (C). 6. For two-headed pumps: Carry out steps 3 to 4 for the second pump head. Changing diaphragm 1. Undo the three cross recessed countersunk head screws (M). 2. Remove retainer plate (R) and diaphragm (B). 3. Inspect all parts for dirt and clean them if necessary. 4. Turn the fan until the connecting rod (S) is in mid-stroke. 5. Position the new diaphragm (B) on the connecting rod (S). 6. Lay the retainer plate (R) on the new diaphragm (B). The roll pin (P) fits in the small hole in the retainer plate. 7. Tighten the three new cross recessed countersunk head screws (M) firmly. 8. For two-headed pumps: Carry out steps 1 to 7 for the second pump head. Changing reed valves 1. Undo reed valve screws (J) and (K). 2. Inspect all parts for dirt and clean them if necessary. 3. Replace reed valves (L, 2 pieces) and (N, 1 piece). 4. For two-headed pumps: Carry out steps 1 to 3 for the second pump head. Mounting pump head 1. Place head (C) on the diaphragm according to the marks made previously, but check that the head of the valve fastening screw (K) lies directly above the hole in the retainer plate (R). 2. Place the new sealing (D) and cover plate (E) on housing (A). 3. Tighten the hexagon socket head cap screws (F), (G) and (H) uniformly and diagonally (tightening torque: 14 Nm). 4. Turn the fan to check that the pump rotates freely. 26 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Servicing 5. Remount fan cover (Fig. 1/4, p. 8 or Fig. 3/6, p. 9, Fig. 5/5, p. 10, Fig. 7/6, p. 11 and Fig. 9/5, p.12). 6. For two-headed pumps: Remount the pneumatic connection(s). b) .9 versions (increased gas tightness) In principle, maintenance is performed as described in a), but with the following exceptions: Cross recessed countersunk head screws (M) are not present Retainer plate (R) is removed and retightened with a wrench for retainer plate (see chapter 10, Spare parts and accessories). Please ask KNF for the order numbers of spare parts (see last page for phone number) Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 27 Troubleshooting Diaphragm Pumps N 1200/1400 9. Troubleshooting Extreme danger from electrical shock! Disconnect the pump power supply before working on the pump. Make sure the pump is de-energized and secure. DANGER Check the pump (see Tab. 14 and 15). Pump does not transfer Cause Pump is not connected with the power source. No voltage in the power source Fault remedy Connect pump with the power source. Thermal switch has operated following to over-heating. Connections or lines blocked. External valve is closed or filter is clogged. Condensate has collected in pump head. Working diaphragm or reed valves are worn. Check room fuse and switch on if necessary. Disconnect pump from mains. Allow pump to cool. Trace cause of over-heating and eliminate it. Check connections and lines. Remove blockage. Check external valves and filters. Detach the condensate source from the pump. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). Replace working diaphragm, safety diaphragm and, if necessary, reed valves (see chapter 8.3). Tab. 14 Flow rate, pressure or vacuum too low The pump does not achieve the output specified in the Technical data or the data sheet. Cause Fault remedy Condensate has collected in Detach the condensate source from the pump. pump head. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas). There is gauge pressure on Change the pressure conditions. pressure side and at the same time vacuum or a pressure above atmospheric pressure on suction side. Pneumatic lines or connection Disconnect pump from system to determine output values. parts have an insufficient cross Eliminate throttling (e.g. valve) if necessary. section. Use lines or connection parts with larger cross section if necessary. Leaks occur on connections, Eliminate leaks. lines or pump head. Connections or lines completely Check connections and lines. or partially jammed. Remove the jamming parts and particles. Head parts are soiled. Clean head components. Working diaphragm or reed valves are worn. Replace working diaphragm, safety diaphragm and, if necessary, reed valves (see chapter 8.3). Tab. 15 28 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Troubleshooting Fault cannot be rectified If you are unable to determine any of the specified causes, send the pump to KNF Customer Service (see last page for the address). 1. Flush the pump under atmospheric conditions some minutes with air (if necessary for safety reasons: with an inert gas) to free the pump head of dangerous or aggressive gases (see chapter 8.2.1). 2. Clean the pump (see chapter 8.2.2). 3. Send the pump to KNF with a filled out decontamination declaration (see chapter 11) and specification of the medium transferred. Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 29 Spare parts and accessories Diaphragm Pumps N 1200/1400 10. Spare parts and accessories Spare parts For .9 versions (increased gas tightness) please ask KNF for the order numbers of spare parts (see last page for phone number). N 1200 SNE, N 1400 SNE Spare part Diaphragm Cross recessed countersunk head screw Reed valve O-Ring Position* (B) (G) Order No. 014274 110732 (L,N) (M) 003475 007524 Tab. 16 *according to Fig. 17 N 1200 SVE, N 1400 SVE Spare part Diaphragm Cross recessed countersunk head screw Reed valve O-Ring Position* (B) (G) Order No. 003476 110732 (L,N) (M) 003475 002458 Tab. 17 * according to Fig. 17 N 1200 STE, N 1400 STE Spare part Diaphragm Cross recessed countersunk head screw Reed valve O-Ring Position* (B) (G) Order No. 003478 110732 (L,N) (M) 003475 006864 Tab. 18 * according to Fig. 17 N 1200 ANE, N 1400 ANE Spare part Diaphragm Cross recessed countersunk head screw Reed valve Sealing Tab. 19 30 Position* (B) (M) Order No. 014274 110732 (L,N) (D) 003475 110686 * according to Fig. 18 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 Diaphragm Pumps N 1200/1400 Spare parts and accessories N 1200 AVE, N 1400 AVE Spare part Diaphragm Cross recessed countersunk head screw Reed valve Sealing Position* (B) (M) Order No. 003476 110732 (L,N) (D) 003475 027274 Tab. 20 * according to Fig. 18 N 1200 ATE, N 1400 ATE Spare part Diaphragm Cross recessed countersunk head screw Reed valve Sealing Position* (B) (M) Order No. 003478 110732 (L,N) (D) 003475 027274 Tab. 21 * according to Fig. 18 Accessories Accessories Silencer/ Filter Pressure relief valve 0,5 - 4 bar Pressure relief valve 4 - 8 bar Wrench for retainer plate for pump type N 1200 A_E N 1400.1 A_E N 1400.2 A_E N 1400.3 A_E N 1200__E N 1400.2 __E N 1200__E N 1400.2 __E N 1200 AN.9E N 1200 ST.9E N 1400.2 AN.9E Order No. 000358 000355 000357 018816 Tab. 22 Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 31 Decontamination declaration Diaphragm Pumps N 1200/1400 11. Decontamination declaration The condition for the repair of a pump by KNF is the certification of the customer on the transferred media and on the cleaning of the pump (decontamination declaration). Copy this page. Enter the pump model, the Serial No. and the transferred media in the form below and sent the signed form together with the flushed and cleaned pump to KNF Customer Service (see last page for the address). Customer decontamination declaration for repair order We herewith confirm that the following media have been pumped with the pump listed below, and that the pump has been flushed and cleaned. Pump model Serial No. Fed media The pump contains neither aggressive, biological, radioactive, poisonous nor other dangerous media. Company 32 Date/Signature Translation of original Operating and Installation Instructions, english, KNF 120845-121497 07/13 KNF worldwide Benelux Netherlands KNF Verder B.V. Utrechtseweg 4a NL-3451 GG Vleuten Tel. 0031 (0)30 677 92 40 Fax 0031 (0)30 677 92 47 E-mail: [email protected] www.knf-verder.nl Benelux Belgium, Luxembourg KNF Verder N.V. Kontichsesteenweg 17 B-2630 Aartselaar Tel. 0032 (0)3 8719624 Fax 0032 (0)3 8719628 E-mail: [email protected] www.knf.be China KNF Neuberger Trading (Shanghai) Co., Ltd No. 36 Lane 1000 Zhang Heng Road Shanghai 201203, P.R. China Tel. 0086 (0)21 685 965 66 Fax 0086 (0)21 339 006 26 E-mail: [email protected] www.knf.com.cn Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Tel. 0049 (0)7664 5909-0 Fax 0049 (0)7664 5909-99 E-mail: [email protected] www.knf.de France, Morocco, Algeria KNF Neuberger 4, Bld. d’Alsace Z.I. F-68128 Village-Neuf Tel. 0033 (0)389 70 35 00 Fax 0033 (0)389 69 92 52 E-mail: [email protected] www.knf.fr Great Britain KNF Neuberger U.K. Ltd. Avenue 2 Station Lane Industrial Estate Witney Oxon OX28 4FA Tel. 0044 (0)1993 77 83 73 Fax 0044 (0)1993 77 51 48 E-mail: [email protected] www.knf.co.uk Sweden, Denmark, Finland, Norway KNF Neuberger AB Mejerivägen 4, P.O. Box 44060 SE-10073 Stockholm Tel. 0046 (0) 87445113 Fax 0046 (0) 87445117 E-mail: [email protected] www.knf.se India KNF Pumps + Systems (India) Pvt. Ltd. RAJIV GANDHI INFOTECH PARK Phase 1 Ganga Estate, Survey No. 152/2/2 Above AXIS BANK Hinjewadi Pune 411 057 Tel. 0091 (0)20 640 13 923 0091 (0)20 640 08 923 Fax 0091 (0)20 229 33 923 E-mail: [email protected] www.knfpumps.in Switzerland Sales KNF Neuberger AG Stockenstrasse 6 CH-8362 Balterswil Tel. 0041 (0)71 973 993 0 Fax 0041 (0)71 973 993 1 E-mail: [email protected] www.knf.ch Italy KNF ITALIA S.r.l. Via Flumendosa, 10 I-20132 Milano Tel. 0039 02 27 20 38 60 Fax 0039 02 27 20 38 48 E-mail: [email protected] www.knf.it Japan KNF Japan Co.Ltd. Across Shinkawa Bldg. Annex 3F 1-16-14 Shinkawa, Chuo-ku, Tokyo, Japan 104-0033 Tel. 0081 (0)3 3551-7931 Fax 0081 (0)3 3551-7932 E-mail: [email protected] www.knf.co.jp Taiwan KNF Neuberger Ltd. 9-2 FL., No., 24, Lane 123, Section 6, Ming Chuan East Road Taipei City, Taiwan Tel. 00886-2-2794-1011 Fax 00886-2-8792-1648 E-mail: [email protected] www.knftwn.com.tw USA, Canada, South America KNF NEUBERGER, INC. Two Black Forest Road Trenton, New Jersey 08691-1810 Tel. 001 (609) 890 86 00 Fax 001 (609) 890 83 23 E-mail: [email protected] www.knfusa.com South America Direct Phone: 001 609 649 1010 E-mail: [email protected] Korea KNF Neuberger Ltd. Woosan Bldg.RM#202, 336-4, Hwikyung-Dong Dongdaemun-Ku., 130-090, Seoul Tel. 0082 (0)2 959-0255/6 Fax 0082 (0)2 959-0254 E-mail: [email protected] www.knfkorea.com KNF product centres Product centre for gas pumps: Germany KNF Neuberger GmbH Alter Weg 3 D-79112 Freiburg Phone 0049(0)7664 5909-0 Fax 0049(0)7664 5909-99 E-mail: [email protected] www.knf.de Product centre for fluid pumps: Switzerland KNF FLODOS AG Wassermatte 2 CH-6210 Sursee Phone 0041(0)41 925 00 25 Fax 0041(0)41 925 00 35 E-mail: [email protected] www.knf-flodos.ch Product centre for micro pumps: Switzerland KNF Micro AG Zelglimatte 1b CH-6260 Reiden Tel. 0041(0)62 787 88 88 Fax 0041(0)62 787 88 99 E-mail: [email protected] www.knf-micro.ch
© Copyright 2026 Paperzz