Calibration and Measurement Capabilities Amount of substance, Gases, Brazil, INMETRO (Instituto Nacional de Metrologia, Qualidade e Tecnologia) The expanded uncertainty ranges given in the following CMCs may be expressed according to two conventions. For 'Uncertainty convention 1', the expanded uncertainty range spans from the smallest numerical value of the uncertainty to the largest numerical value of the uncertainty found within the quantity range. For 'Uncertainty convention 2', the expanded uncertainty range is expressed as the uncertainty of the smallest value of the quantity to the uncertainty of the largest value of the quantity. The expanded uncertainties correspond to k = 2 (level of confidence 95%). Measurand NMI Service Identifier 8833b Measurement Service SubCategory Environmental nitrogen Analyte or Component Quantity From To Unit From To Unit Is the expanded uncertainty a relative one? carbon monoxide Amount-ofsubstance fraction 3 90 mmol/m ol 1.0 1.0 % Yes 0.75 0.75 % Yes 0.5 0.5 % Yes 10 propane 8833g Environmental nitrogen propane 8833h Environmental nitrogen carbon monoxide 8833j Environmental nitrogen sulfur dioxide 8633b Environmental nitrogen carbon monoxide 8897b Environmental nitrogen carbon dioxide 8123 Environmental nitrogen propane 8634 Environmental nitrogen carbon monoxide 200 Amount-ofsubstance fraction Amount-ofsubstance fraction Amount of substance fraction Amount of substance fraction Amount of substance fraction Amount of substance fraction Amount of substance fraction carbon dioxide propane Fuel synthetic natural gas methane Amount-ofsubstance fraction carbon dioxide nitrogen 8833l Environmental Range of Expanded Uncertainties as Disseminated Range of Certified Values in Reference Materials Matrix carbon dioxide 8833a Dissemination Range of Measurement Capability nitrogen nitrogen monoxide Amount-ofsubstance fraction The BIPM key comparison database, October 2015 mmol/m ol µmol/mo 3500 l 150 From To Unit Range of Expanded Uncertainties for Mechanism(s) Certified Value for Measurement Is the Service expanded Delivery From To Unit uncertainty a relative one? Comment(s) Calibration service Approved on 27 March 2013 Comment(s) 100 3500 µmol/mo l 1.0 0.5 % Yes Calibration service Approved on 27 March 2013 Uncertainty convention 2 1 500 µmol/mo l 3.0 2.0 % Yes Calibration service Approved on 27 March 2013 Uncertainty convention 2 50 5000 µmol/mo l 2 1 % Yes Calibration services Approved on 06 September 2012 Uncertainty convention 2 1 100 mmol/m ol 1.0 0.75 % Yes 1 100 mmol/ mol 0.75 0.6 % Yes MRC 8633 Approved on 27 March 2013 Uncertainty convention 2 10 200 mmol/m ol 0.75 0.5 % Yes 10 200 mmol/ mol 0.75 0.5 % Yes MRC 8897 Approved on 27 March 2013 Uncertainty convention 2 300 50000 µmol/mo l 1.0 0.6 % Yes 300 50000 µmol/m ol 1.0 0.6 % Yes MRC 8123 Approved on 27 March 2013 Uncertainty convention 2 1 100 mmol/m ol 1.0 0.75 % Yes 1 100 mmol/ mol 0.75 0.6 % Yes MRC 8634 Approved on 27 March 2013 Uncertainty convention 2 10 200 0.75 0.5 % Yes 10 200 0.75 0.5 % Yes 0.3 3.5 1.0 0.6 % Yes 0.3 3.5 1.0 0.6 % Yes 700 920 0.5 0.35 % Yes Calibration service Approved on 20 November 2014 Uncertainty convention 2 5 70 1.0 0.7 % Yes 5 100 1.0 0.75 % Yes 30 70 2.0 2.0 % Yes Calibration services Approved on 20 November 2014 Uncertainty convention 2 mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol µmol/mo l mmol/ mol mmol/ mol 1/2 Calibration and Measurement Capabilities Measurand NMI Service Identifier Measurement Service SubCategory Dissemination Range of Measurement Capability Range of Expanded Uncertainties as Disseminated Range of Certified Values in Reference Materials Matrix Range of Expanded Uncertainties for Mechanism(s) Certified Value for Measurement Is the Service expanded Delivery From To Unit uncertainty a relative one? Comment(s) Comment(s) MRC 8427 Approved on 20 November 2014 Uncertainty convention 2 From To Unit From To Unit Is the expanded uncertainty a relative one? 50 500 µmol/mo l 2 1 % Yes 10 200 mmol/m ol 1.0 1.0 % Yes Calibration service Approved on 21 October 2015 10 200 mmol/m ol 1.0 1.0 % Yes Calibration service Approved on 21 October 2015 100 1000 µmol/mo l 1.0 1.0 % Yes Calibration service Approved on 21 October 2015 Uncertainty convention 2 100 1000 µmol/mo l 1.0 1.0 % Yes Calibration service Approved on 21 October 2015 Uncertainty convention 2 50 500 µmol/mo l 2 1 % Yes Calibration services Approved on 21 October 2015 Uncertainty convention 2 30 1000 µmol/mo l 2.0 0.6 % Yes 30 1000 µmol/m ol 2.0 0.6 % Yes MRC 8416 Approved on 21 October 2015 Uncertainty convention 2 30 1000 µmol/mo l 2.0 0.6 % Yes 30 1000 µmol/m ol 2.0 0.6 % Yes MRC 8936 Approved on 21 October 2015 Uncertainty convention 2 700 980 mmol/m ol 0.1 0.3 % Yes Calibration service Approved on 21 October 2015 Uncertainty convention 1 ethane 5 100 0.6 0.6 % Yes propane 1 45 0.6 0.6 % Yes i-butane 0.5 10 0.8 0.8 % Yes n-butane 0.5 10 0.8 0.8 % Yes i-pentane 0.2 2 1.5 1.2 % Yes n-pentane 0.2 2 1.5 1.2 % Yes n-hexane 0.1 1.5 2.0 1.5 % Yes carbon dioxide 5 70 0.5 0.5 % Yes 5 100 1.0 1.0 % Yes Analyte or Component 8427 Forensic nitrogen ethanol 8833d Environmental nitrogen carbon dioxide 8833f Environmental synthetic air carbon dioxide 8833c Environmental nitrogen carbon dioxide 8833e Environmental synthetic air carbon dioxide 8833i Forensic nitrogen ethanol 8416a Environmental nitrogen methane 8936a Environmental synthetic air methane 8833a Fuel synthetic natural gas methane Quantity Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction Amount-ofsubstance fraction nitrogen 8833m Environmental nitrogen methane 8833n Environmental synthetic air methane Amount-ofsubstance fraction Amount-ofsubstance fraction The BIPM key comparison database, October 2015 mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol mmol/m ol From To Unit 50 500 µmol/m ol 2 1 % Yes 10 20000 µmol/mo 0 l 1.0 0.75 % Yes Calibration service Approved on 21 October 2015 Uncertainty convention 2 10 20000 µmol/mo 0 l 1.0 0.75 % Yes Calibration service Approved on 21 October 2015 Uncertainty convention 2 2/2
© Copyright 2026 Paperzz