The rechargeable batteries are lead-lead dioxide (12V60Ah/20hr) systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus immobilized. Should the battery be accidentally overcharged producing bydrogen and oxygen, Special one-way valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. UN60-12S Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid General Feature Performance Characteristics Absorbent Glass Mat(AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge. Capacity 77°F(25 ) ℃ Internal Resistance Self-Discharge ℃ 57Ah 54Ah 40Ah °F(40℃) 77°F(25℃) 32°F(10℃) 5°F(-15℃) ℃):6mΩ 102% 104 100% 85% 65% Capacity after 3 month storage 90% Capacity after 6 month storage 80% Capacity after 12month storage 60% ℃ SPECIFICATION ……………… 12V ……………… 6 Length(mm/inch) ……………… 250/9.84 Width(mm/inch ……………… 160/6.30 Height(mm/inch) ……………… 178/7.01 Total Height(mm/inch) ………… 197/7.76 Approx. Weight(kg/lbs) ………… 18/39.7 Max. discharge current77°F(25 ): 600A(5S) Nominal voltage Number of cell : ~13.8 V/77°F/(25℃) Cycle:14.4~14.7 V/77°F/(25℃) Max. Current:15A Charge (Constant Voltage) Float 13.6 Discharge Constant Current (Amperes at 77° F25 End Point Volts/Cell 250±1 1 ± 79 1 5min 10min 15min 30min 1.60V 195 145 111 67.0 1.65V 186 139 107 65.0 1.70V 176 132 102 63.0 1.75V 164 124 96.5 60.8 1.80V 150 115 90.0 58.4 1h ℃) 3h 5h 10h 20h 40.0 16.9 11.3 6.00 3.20 38.8 16.5 11.2 5.95 3.15 37.5 16.0 11.0 5.90 3.15 36.2 15.5 10.8 5.80 3.10 34.8 14.9 10.5 5.70 3.00 Discharge Constant Power (watts at 77° F 25 End Point Volts/Cell Terminal(F5) 1 ± 06 1 60Ah Full charged Battery77°F(25 Capacity affected by Temperature (10 hour rate) 68°F(20 ) 1± 871 、 10 hour rate (5.7A、10.8V) 5 hour rate (10.8A、10.5V) 1 hour rate (40A、9.6V) 20 hour rate (3A 10.8V) 20 3 7 5min 10min 15min 30min 45min ℃) 1h 2h 3h 5h 1.60V 350 250 198 125 94.1 76.0 44.0 32.5 21.8 1.65V 337 241 191 121 92.3 74.7 43.1 31.8 21.4 1.70V 322 231 183 116 90.3 73.3 42.1 31.0 20.9 1.75V 305 220 175 112 88.3 71.8 41.0 30.2 20.4 1.80V 286 208 166 107 86.0 70.0 39.8 29.3 19.8 (Note)The above characteristics data are average values obtained Within three charge/discharge cycles not the minimum values. Page1 of 2 UN60-12S (12V60Ah) charge characteristic curve t n e r r u C e g a t l o V (%) (rCA) (V) 120 0.25 d e g r a h C e m u l o V 100 80 0.20 0.15 60 40 20 0.10 0.05 15.0 Charged ) V ( e g a t l o v y r t t a B volume 14.0 Charge voltage 13.0 12.0 11.0 0 0 Discharge characteristic(25℃) Constant voltage charging characteristic (0.25CA,25℃ ) Charging current 0 2 4 6 8 10 12 14 16 18 13.0 12.0 11.0 10.0 16A 180A 9.0 8.0 0 01 2 3 5 20 10.8A 6A 3A 60A 40A 10 20 30 60 2 3 5 10 20 30 min h Discharge time Charging time( hours) Temperature effects on float life Cycle service life in relation to depth of discharge 120 15 100 ) s r a e y ( e f i L 2.30V/cell 10 %) (y ti c paa C 5 80 60 100%D.O.D 30% Depth of discharge 50%D.O.D 40 20 0 10 20 30 40 50 0 200 400 Temperature(℃) e g a t l o V g n i g r a h C ) V 8 / V ( ) V 6 / V ( 15.6 10.4 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2 1200 1400 1 10 )% (y ti ca pa C CYC LE USE STAN D BY USE 1 00 90 80 70 60 40 ℃ 2 0℃ 30 ℃ 50 -10 0 10 20 30 40 50 Ambient temperature(℃) 40 60 0 2 4 6 8 10 12 14 16 18 20 S to r a g e t im e: m on t h s Life characteristics of standby use Temperature effects on capacity 120 %) (y ti ca p Ca 1000 Se lf -d is ch ar g e c h a r a c t e r i s t i c ) l l e c / V ( ) V 4 / V ( 800 Number of cycles(cycles) Relationship between charging voltage and temperature ) V 2 1 / V ( 600 120 100 ) % ( y t i c a p a C 80 60 Testing conditions floating voltage:2.27 to 2.30V/cell 40 20 100 60 4 6 Life(year) 1.0C 2.0C 40 20 0 0 0.05C 0.1C 0.2C 80 8 -20 -10 0 10 20 30 40 Temperature(℃ ) DONGGUAN OREMA POWER CO., LTD Add: Daping Industrial Area, Tangxia Town, 523722 Dongguan China TEL: +86-769- 8201 6663 +86-769- 8786 5131 www.oremabattery.com FAX: +86-769- 87865135 Page2 of 2 50
© Copyright 2025 Paperzz