WS600-UMB – Temperature, Relative Humidity, Precipitation, Air

WS600-UMB – Temperature, Relative Humidity,
Precipitation, Air Pressure, Wind
From the WS product family of professional intelligent measurement transducers
with digital interface for environmental
applications.
Integrated design with ventilated radiation
protection for measuring:
- Air temperature
- Relative humidity
- Precipitation intensity
- Precipitation type
- Precipitation quantity
- Air pressure
- Wind direction
- Wind speed
Relative humidity is measured by means
of a capacitive sensor element; a precision NTC measuring element is used to
measure air temperature.
WS600-UMB Compact weather station
Order No.
WS600-UMB EU, USA, Canada
WS600-UMB UK
Technical Data
Dimensions
Weight
Temperature
Principle
Measuring range
Accuracy
8370.U01
8370.U02
Relative humidity
Precipitation
intensity
Precipitation type
Air pressure
Wind direction
Wind speed
Precipitation is measured by way of a
24 GHz Doppler radar, which measures
the drop speed of an individual drop of
rain/snow.
General
Information
Precipitation quantity and intensity are
calculated from the correlation between
drop size and speed.
Accessories
Ø approx. 150 mm, height approx. 345 mm
approx. 2.2 kg
NTC
–50 … 60 ° C
±0.2 ° C (–20 ° C … +50 ° C),
otherwise ±0.5 ° C ( > –30 ° C)
Capacitive
0 … 100 % RH
±2 % RH
0.01 mm
Drop size 0.3 … 5 mm
typ. > 90 %
Principle
Measuring range
Accuracy
Resolution
Measuring range
Reproducibility
Rain/snow
Principle
MEMS capacitive
Measuring range
300 … 1200 hPa
Accuracy
±1.5 hPa
Principle
Ultrasonic
Measuring range
0 … 359.9 °
Accuracy
±3 °
Principle
Ultrasonic
Measuring range
0 … 60 m/s
Accuracy
± 0.3 m/s or ±3 % (0 … 35 m/s)
Heating
40 VA at 24 VDC
Interface
RS485, 2-wire, half-duplex
Op. power consumption 24 VDC +/-10 % < 4 VA (without heating)
Operating humidity range 0 … 100 %
Op. temperature range
–50 … 60 ° C
Surge protection
Power supply 24V/4A
UMB Interface converter ISOCON
8379.USP
8366.USV1
8160.UISO
The difference in drop speed determines
the type of precipitation (rain/snow).
Maintenance-free measurement offers
a major advantage over the common
tipping spoon and tipping bucket
processes.
Ultrasonic sensor technology is used to
take wind measurements.
Measurement data are available for
further processing in the form of a
standard protocol (Lufft-UMB protocol).
All in One
Aspirated temperature/ humidity measurement
Maintenance-free operation
Open communication protocol:
ASCII
UMB
SDI12
Coming soon:
MODBUS, analog outputs
5
WS500-UMB – Air Pressure, Relative Humidity, Wind
From the WS product family of professional intelligent measurement transducers
with digital interface for environmental
applications.
WS500-UMB Compact weather station
Order No.
WS500-UMB
Technical Data
8373.U01
Temperature
Integrated design with ventilated radiation protection for measuring:
- Air temperature
- Relative humidity
- Air pressure
- Wind direction
- Wind speed
Relative humidity
Air pressure
Wind direction
Relative humidity is measured by means
of a capacitive sensor element; a precision NTC measuring element is used to
measure air temperature.
Maintenance-free measurement offers
a major advantage. Measurement data
are available for further processing in the
form of a standard protocol (Lufft-UMB
protocol).
Ultrasonic wind sensor
Maintenance-free operation
Open communication protocol:
ASCII
UMB
SDI12
Coming soon:
MODBUS, analog outputs
6
Wind speed
General
Information
Accessories
Dimensions
Weight
Principle
Measuring range
Accuracy
Ø approx. 150 mm, height approx. 290 mm
approx. 1.3 kg
NTC
-50 … 60 ° C
±0.2 ° C (–20 ° C … +50 ° C),
otherwise ±0.5 ° C (> -30 ° C)
Principle
Capacitive
Measuring range
0 … 100 % RH
Accuracy
±2 % RH
Principle
MEMS Capacitive
Measuring range
300 … 1200 hPa
Accuracy
±1.5 hPa
Principle
Ultrasonic
Measuring range
0 … 359.9 °
Accuracy
±3 °
Principle
Ultrasonic
Measuring range
0 … 60 m/s
Accuracy
±0.3 m/s or ±3 % (0 … 35 m/s)
Heating
20 VA at 24 VDC
Interface
RS485, 2-wire, half-duplex
Op. power consumption 24 VDC +/-10 % < 4 VA (without heating)
Operating humidity range 0 … 100 %
Op. temperature range
–50 … 60 ° C
Surge protection
Power supply 24V/4A
UMB Interface converter ISOCON
Traverse for R25 + WS500
8379.USP
8366.USV1
8160.UISO
8367.TRAV
WS400-UMB – Temperature, Relative Humidity,
Precipitation, Air Pressure
From the WS product family of professional intelligent measurement transducers
with digital interface for environmental
applications.
Integrated design with ventilated radiation
protection for measuring:
- Air temperature
- Relative humidity
- Precipitation intensity
- Precipitation type
- Precipitation quantity
- Air pressure
Relative humidity is measured by means
of a capacitive sensor element; a precision NTC measuring element is used to
measure air temperature.
Precipitation is measured by way of a
24 GHz Doppler radar, which measures
the drop speed of an individual drop of
rain/snow.
Precipitation quantity and intensity are
calculated from the correlation between
drop size and speed.
WS400-UMB Compact weather station
Order No.
WS400-UMB EU, USA, Canada
WS400-UMB UK
Technical Data
Dimensions
Weight
Temperature
Principle
Measuring range
Accuracy
8369.U01
8369.U02
Relative humidity
Precipitation
intensity
Precipitation type
Air pressure
General
Information
Accessories
Ø approx. 150 mm, height approx. 280 mm
approx. 2 kg
NTC
–50 … 60 ° C
±0.2 ° C (–20 ° C … +50 ° C),
otherwise ±0.5 ° C (> -30 ° C)
Capacitive
0 … 100 % RH
±2 % RH
0.01 mm
Measuring range drop size 0.3 … 5 mm
typ. > 90 %
Principle
Measuring range
Accuracy
Resolution
Measuring range
Reproducibility
Rain/snow
Principle
MEMS Capacitive
Measuring range
300 … 1200 hPa
Accuracy
±1.5 hPa
Heating
20 VA at 24 VDC
Interface
RS485, 2-wire, half-duplex
Op. power consumption 24 VDC +/-10 % < 4 VA (without heating)
Operating humidity range 0 … 100 %
Op. temperature range
–50 … 60 ° C
Surge protection
Power supply 24 V/4 A
UMB Interface converter ISOCON
8379.USP
8366.USV1
8160.UISO
The difference in drop speed determines the type of precipitation (rain/snow).
Maintenance-free measurement offers
a major advantage over the common
tipping spoon and tipping bucket processes. Measurement data are available
for further processing in the form of a
standard protocol (Lufft-UMB protocol).
Radar-based precipitation detection
Aspirated temperature/humidity measurement
Open communication protocol:
ASCII
UMB
SDI12
Coming soon:
MODBUS, analog outputs
7
WS300-UMB – Temperature, Air Pressure,
Relative Humidity
From the WS product family of professional intelligent measurement transducers
with digital interface for environmental
applications.
WS300-UMB Compact weather station
Order No.
WS300-UMB
Technical Data
8372.U01
Temperature
Integrated design with ventilated radiation
protection for measuring:
- Air temperature
- Relative humidity
- Air pressure
Relative humidity is measured by means
of a capacitive sensor element;
a precision NTC measuring element is
used to measure air temperature.
Measurement data are available for
further processing in the form of a
standard protocol (Lufft-UMB protocol).
Aspirated temperature/humidity measurement
Open communication protocol:
ASCII
UMB
SDI12
Coming soon:
MODBUS, analog outputs
8
Relative humidity
Air pressure
General
Information
Accessories
Dimensions
Weight
Principle
Measuring range
Accuracy
Ø approx. 150 mm, height approx. 225 mm
approx. 0.8 kg
NTC
–50 … 60 ° C
±0.2 ° C (–20 ° C … +50 ° C),
otherwise ±0.5 ° C (> –30 ° C)
Principle
Capacitive
Measuring range
0 … 100 % RH
Accuracy
±2 % RH
Principle
MEMS Capacitive
Measuring range
300 … 1200 hPa
Accuracy
±1.5 hPa
Interface
RS485, 2-wire, half-duplex
Op. power consumption 24 VDC +/-10 % < 4 VA
Operating humidity range 0 … 100 %
Op. temperature range
–50 … 60 ° C
Surge protection
8379.USP
Power supply 24 V/4 A
8366.USV1
UMB Interface converter ISOCON
8160.UISO
WS200-UMB – Ultrasonic Wind Sensor
From the WS product family of professional intelligent measurement transducers
with digital interface for environmental
applications.
Integrated design with ventilated radiation
protection for measuring:
- Wind direction
- Wind speed
Ultrasonic sensor technology is used to
take wind measurements.
Measurement data are available for
further processing in the form of a
standard protocol (Lufft-UMB protocol).
WS200-UMB Compact weather station
Order No.
WS200-UMB
Technical Data
8371.U01
Wind direction
Wind speed
General
Information
Accessories
Dimensions
Ø approx. 150 mm, height approx. 200 mm
Weight
approx. 0.8 kg
Principle
Ultrasonic
Measuring range
0 … 359.9 °
Accuracy
±3 °
Principle
Ultrasonic
Measuring range
0 … 60 m/s
Accuracy
±0.3 m/s or ±3 % (0 … 35 m/s)
Heating
20 VA at 24 VDC
Interface
RS485, 2-wire, half-duplex
Op. power consumption 24 VDC +/-10 % < 4 VA (without heating)
Operating humidity range 0 … 100 %
Op. temperature range
–50 … 60 ° C
Surge protection
8379.USP
Power supply 24 V/4 A
8366.USV1
UMB Interface converter ISOCON
8160.UISO
Ultrasonic wind measurement
Open communication protocol:
ASCII
UMB
SDI12
Coming soon:
MODBUS, analog outputs
9