Q-Eye PSC MT

Stationary Flow Meter
for Pipes and Open Channels
Q-Eye PSC MT
Q-Eye PSC MT
The Q-Eye PSC MT permanent velocity area flow meter is
designed for applications in full or partially full pipes
100 - 2000 mm (4 – 80 inches) in diameter, or open channels with flow depths 40 – 2000 mm (1,5 - 80 inches).
It uses advanced Doppler profiling technology to directly measure velocity profiles making it the best choice
for sites with non-uniform, rapidly changing, backwatered, near zero, negative or reverse flow conditions.
This eliminates the need for on-site calibration, thereby
reducing significantly the cost of installation.
Combined with an integral upward looking ultrasonic
or a secondary external pressure sensor (optional) for
determining the depth, the meter is using a numerical
model for averaged velocity in the entire cross section
and the continuity equation to calculate flow.
Profiling Technology
Pulsed wave Doppler systems use a transducer that transmits short acoustic pulses. The received echo is rangegated to provide velocity measurements selectively from
a small segment along the acoustic beam, step by step
over the entire velocity profile.
Reflections of particles in other areas do not have any
influence on the velocity measurement. Additionally the
1 MHz sensor provides higher data resolution by detecting smaller particles.
Flow Meter
Q-Eye PSC MT (Insertion)
The system can be equipped with up to 4 analog
inputs, up to 4 analog outputs, 2 digital outputs and 4
relays.
Data Transmission
Automatic data transmission via GPRS communication
is an option and can be used worldwide. The logged
data can be sent to any host computer (FTP-Server)
or to HydroVision’s web-based HydroCenter at a userselectable frequency (typically 4 times a day, once a day
or once a week). Alternatively, WLAN and Ethernet are
available.
2
The Q-Eye PSC MT is ideal for permanent
flow monitoring studies/surveys:
»»Wastewater collection systems
(Infiltration studies, hydraulic model calibration,
event notification, long term trend analysis)
»»Combined sewer systems (Characterize combined
sewer overflow (CSO) impacts)
»»Wastewater treatment facilities
(Influent measurement, real-time process control,
effluent measurement)
»»Irrigation channels (Supply management)
»»Industrial flows (Flow measurement, process
optimization)
»»Storm water runoff monitoring
Technical Information
Q-Eye PSC MT
Transmitter
Parameterization of the measurement site and data visualization is easily possible using the standard web-browser of your
already existing smartphone, tablet PC or notebook – there is
no need for any additional software or App. The interface is
graphical and menu-driven for rapid comissioning. Your flow
meter can be accessed from anywhere - anytime 24/7.
Software
Insertion Type
Q-Eye PSC MT is a major improvement in open channel flow
measurement. It’s the latest entry in the HydroVision family of
high accuracy metering products. This flow computer incorporates all of the required algorithms and software to ensure
accuracy and repeatability. The IP65 (NEMA 4X) compact flow
display computer has a 4x20 alphanumeric LCD display and a 4
button keypad. All configuration data and measured and calculated data are stored inside an 16GB Micro-SD card. It controls the measurements, calculates the flow rate and provides
freely programmable current outputs, status alarm, frequency
outputs and totalizer readings.
Low Profile
Velocity Area Sensor
Sensors
Mounting Systems
Mounting Plate, Spring Ring and
Scissors Rings
The submergible depts and velocity sensor which measures
only 15x25x108 mm is the smallest sensor of this type currently
available. A low profile means less interference, which results
in more accurate velocity measurements, especially in low-flow
situatuons. The insertion sensor is used, when the pipe is accessible from the outside only. For use in full pipes or partially
full pipes when used in conjunction with an ultrasonic pressure
depth sensor. These sensors can be installed into existing pipework through an 2“ ball valve.
All sensors can be attached to a mounting plate, spring and scissors rings to install the sensors in minutes and reducing time in
the manhole. The sensor is first attached to a carrier and can
than slide onto any of the compatible mounting systems. This
maintains a height, suitable for measuring flow rates and velocities at very low water levels. To install the sensors in rectangular, trapezoidal or earthen channels, we recommend the sensor mounting plate. Stainless steel spring rings simplify sensor
installation in cylindrical pipes. 6 standard diameter sizes from
200 mm (8 inches) to 600 mm (24 inches) are available. You can
install the sensor and fasten the cable to the downstream edge
of the ring in place before you enter the manhole. The self-expanding device is tight by expanding the band for a friction fit
inside the pipe. The adjustable scissors ring is installed in large
diameter pipes from 500 mm (20 inches) to 1450 mm (57 inches)
in diameter. It consists of a base section, one or more pairs of
extensions to fit the size of the pipe and a scissors mechanism.
Web-based data logging
HydroVision’s web-based data logging system enables real-time
remote access to your data.
WEB Data
hosted via the HV HydroCenter
HydroCenter is our web-based graphing and analysis platform that provides 24/7 web access to data collected with your
flow meter. Go to www.hydrocenter.de
3
Technical Data
Transmitter
Sensor - Mouse Type
Sensor - Insertion Type
Q-Eye PSC MT
Area Velocity Sensor
Specifications Transmitter
Sensor:
1x velocity, 1x water level
Frequency:
1 MHz
Range:
velocity ± 5,3 m/s
water level (ultrasonic) 0,04 -1,3 m
expandable via external
4-20 mA sensor
Accuracy:
± 1% of measured value
for v and h (ultrasonic)
± 2% for flow
Cable Length:
10 m incl. (max. 80m)
Sensor:
1 x velocity
1x water level
Frequency:
1 MHz
Number of Cells:
max. 18 cells
Display:
4 lines, 20 characters
Keyboard:
4 keys
Datalogger:
16GB Micro SD card
Particle Concentration:
> 50 ppm
Communication:
RS485
Material:
Epoxy
MODBUS (RS232 or RS485)
Protection Class:
IP68 (NEMA 6P)
WLAN
Dimensions:
108 x 25 x 15 mm (LxWxH)
GPRS
Insertion Sensor
Ethernet 10/100 Mbps
Inputs:
max. 4 x 4-20 mA
Sensor:
1D velocity for full-filled pipes incl. 2“ ball valve
Frequency:
1 MHz
2x digital
Range:
± 5,3 m/s
4x Relay
Accuracy:
< 0,5 % FS (for v > 1 m/s)
< 0,5 % FS ± 0,0025 m/s (for v < 1 m/s)
Cable Length:
10 m incl. (max. 80m)
Material:
Stainless steel
Dimensions:
diameter: 2“ ; length: 350 mm
2x digital
Outputs:
max. 4 x 4-20 mA
Power Supply:
85-260 VAC (48-60 Hz) or 9-36 VDC
Approval:
IP 65
Enclosure:
ABS, wall mounted
HydroVision GmbH
HydroVision ASIA Pte. Ltd
Gewerbestraße 61A
1 Cleantech Loop
87600 Kaufbeuren
#03-05 CleanTech One
Germany
Singapore 637141
tel. +49 - 8341 - 9662180
tel. +65 - 93299015
(velocity)
represented by:
fax +49 - 8341 - 9666030
[email protected]
[email protected]
www.hydrovision.de
www.hydrovision.de
© 2014/09 HydroVision GmbH. Specifications are for instruments at the time the literature was printed.
Due to continuous product testing and improvement, all specifications are subject to change without notice.