Stationary Flow Meter for Pipes and Open Channels Q-Eye PSC MT Q-Eye PSC MT The Q-Eye PSC MT permanent velocity area flow meter is designed for applications in full or partially full pipes 100 - 2000 mm (4 – 80 inches) in diameter, or open channels with flow depths 40 – 2000 mm (1,5 - 80 inches). It uses advanced Doppler profiling technology to directly measure velocity profiles making it the best choice for sites with non-uniform, rapidly changing, backwatered, near zero, negative or reverse flow conditions. This eliminates the need for on-site calibration, thereby reducing significantly the cost of installation. Combined with an integral upward looking ultrasonic or a secondary external pressure sensor (optional) for determining the depth, the meter is using a numerical model for averaged velocity in the entire cross section and the continuity equation to calculate flow. Profiling Technology Pulsed wave Doppler systems use a transducer that transmits short acoustic pulses. The received echo is rangegated to provide velocity measurements selectively from a small segment along the acoustic beam, step by step over the entire velocity profile. Reflections of particles in other areas do not have any influence on the velocity measurement. Additionally the 1 MHz sensor provides higher data resolution by detecting smaller particles. Flow Meter Q-Eye PSC MT (Insertion) The system can be equipped with up to 4 analog inputs, up to 4 analog outputs, 2 digital outputs and 4 relays. Data Transmission Automatic data transmission via GPRS communication is an option and can be used worldwide. The logged data can be sent to any host computer (FTP-Server) or to HydroVision’s web-based HydroCenter at a userselectable frequency (typically 4 times a day, once a day or once a week). Alternatively, WLAN and Ethernet are available. 2 The Q-Eye PSC MT is ideal for permanent flow monitoring studies/surveys: »»Wastewater collection systems (Infiltration studies, hydraulic model calibration, event notification, long term trend analysis) »»Combined sewer systems (Characterize combined sewer overflow (CSO) impacts) »»Wastewater treatment facilities (Influent measurement, real-time process control, effluent measurement) »»Irrigation channels (Supply management) »»Industrial flows (Flow measurement, process optimization) »»Storm water runoff monitoring Technical Information Q-Eye PSC MT Transmitter Parameterization of the measurement site and data visualization is easily possible using the standard web-browser of your already existing smartphone, tablet PC or notebook – there is no need for any additional software or App. The interface is graphical and menu-driven for rapid comissioning. Your flow meter can be accessed from anywhere - anytime 24/7. Software Insertion Type Q-Eye PSC MT is a major improvement in open channel flow measurement. It’s the latest entry in the HydroVision family of high accuracy metering products. This flow computer incorporates all of the required algorithms and software to ensure accuracy and repeatability. The IP65 (NEMA 4X) compact flow display computer has a 4x20 alphanumeric LCD display and a 4 button keypad. All configuration data and measured and calculated data are stored inside an 16GB Micro-SD card. It controls the measurements, calculates the flow rate and provides freely programmable current outputs, status alarm, frequency outputs and totalizer readings. Low Profile Velocity Area Sensor Sensors Mounting Systems Mounting Plate, Spring Ring and Scissors Rings The submergible depts and velocity sensor which measures only 15x25x108 mm is the smallest sensor of this type currently available. A low profile means less interference, which results in more accurate velocity measurements, especially in low-flow situatuons. The insertion sensor is used, when the pipe is accessible from the outside only. For use in full pipes or partially full pipes when used in conjunction with an ultrasonic pressure depth sensor. These sensors can be installed into existing pipework through an 2“ ball valve. All sensors can be attached to a mounting plate, spring and scissors rings to install the sensors in minutes and reducing time in the manhole. The sensor is first attached to a carrier and can than slide onto any of the compatible mounting systems. This maintains a height, suitable for measuring flow rates and velocities at very low water levels. To install the sensors in rectangular, trapezoidal or earthen channels, we recommend the sensor mounting plate. Stainless steel spring rings simplify sensor installation in cylindrical pipes. 6 standard diameter sizes from 200 mm (8 inches) to 600 mm (24 inches) are available. You can install the sensor and fasten the cable to the downstream edge of the ring in place before you enter the manhole. The self-expanding device is tight by expanding the band for a friction fit inside the pipe. The adjustable scissors ring is installed in large diameter pipes from 500 mm (20 inches) to 1450 mm (57 inches) in diameter. It consists of a base section, one or more pairs of extensions to fit the size of the pipe and a scissors mechanism. Web-based data logging HydroVision’s web-based data logging system enables real-time remote access to your data. WEB Data hosted via the HV HydroCenter HydroCenter is our web-based graphing and analysis platform that provides 24/7 web access to data collected with your flow meter. Go to www.hydrocenter.de 3 Technical Data Transmitter Sensor - Mouse Type Sensor - Insertion Type Q-Eye PSC MT Area Velocity Sensor Specifications Transmitter Sensor: 1x velocity, 1x water level Frequency: 1 MHz Range: velocity ± 5,3 m/s water level (ultrasonic) 0,04 -1,3 m expandable via external 4-20 mA sensor Accuracy: ± 1% of measured value for v and h (ultrasonic) ± 2% for flow Cable Length: 10 m incl. (max. 80m) Sensor: 1 x velocity 1x water level Frequency: 1 MHz Number of Cells: max. 18 cells Display: 4 lines, 20 characters Keyboard: 4 keys Datalogger: 16GB Micro SD card Particle Concentration: > 50 ppm Communication: RS485 Material: Epoxy MODBUS (RS232 or RS485) Protection Class: IP68 (NEMA 6P) WLAN Dimensions: 108 x 25 x 15 mm (LxWxH) GPRS Insertion Sensor Ethernet 10/100 Mbps Inputs: max. 4 x 4-20 mA Sensor: 1D velocity for full-filled pipes incl. 2“ ball valve Frequency: 1 MHz 2x digital Range: ± 5,3 m/s 4x Relay Accuracy: < 0,5 % FS (for v > 1 m/s) < 0,5 % FS ± 0,0025 m/s (for v < 1 m/s) Cable Length: 10 m incl. (max. 80m) Material: Stainless steel Dimensions: diameter: 2“ ; length: 350 mm 2x digital Outputs: max. 4 x 4-20 mA Power Supply: 85-260 VAC (48-60 Hz) or 9-36 VDC Approval: IP 65 Enclosure: ABS, wall mounted HydroVision GmbH HydroVision ASIA Pte. Ltd Gewerbestraße 61A 1 Cleantech Loop 87600 Kaufbeuren #03-05 CleanTech One Germany Singapore 637141 tel. +49 - 8341 - 9662180 tel. +65 - 93299015 (velocity) represented by: fax +49 - 8341 - 9666030 [email protected] [email protected] www.hydrovision.de www.hydrovision.de © 2014/09 HydroVision GmbH. Specifications are for instruments at the time the literature was printed. Due to continuous product testing and improvement, all specifications are subject to change without notice.
© Copyright 2025 Paperzz