Watermeter Type WS

Watermeter Type WS-PE
DN 40...100
for hot water up to 180°C / 200°C
Special Features
• Interchangeable measuring element
• No influence by external magnetic
fields
• Pulsers may be equipped easily
Application
• For measuring hot water up to 180°C
in pressure rate PN 16
• For measuring hot water up to 200°C
in pressure rate PN 40
• For special applications in power plants
Available Designs
Size
Temperature in °C
Pressure in bar
Body material
Order-No.
40
200
40
GS 45
o.r.
50
180
200
16
40
GG 25 GS 45
826338 825961
Installation requirements
• Unrestricted straight pipe 3 x DN
• No restrictions directly behind the meter
Sensus Metering Systems GmbH
Hannover D-30880 Laatzen • Meineckestraße 10
Weitere Informationen unter http://www.sensus.com
ML 4300 GB • Seite 1 von 2
65
180
200
16
40
GG 25
GS 45
826340 826003
80
100
180
200
180
200
16
40
16
40
GG 25
GS 45 GG 25 GS 45
826342 825963 826344 825965
Installation
Technical Data
Performance table COSMOS WS 180 / 200 °C
Qmax
Qn
Qt
Qmin
Size of meter
Maximum peak flow (few minutes)
Continuous flow
Transitional flow ± 2%
Minimum flow
Starting flow
DN
m³/h
m³/h
m³/h
m³/h
m³/h
Typical accuracy curve
DN
mm
mm
mm
mm
mm
40
300
195
80
352
170
50
270
195
80
325
170
65
300
205
100
345
200
80
300
205
100
345
200
100
360
235
110
385
260
DN
kg
kg
40
20.0
4.2
50
19.7
4.2
65
25.4
4.4
80
27.6
4.4
100
52.7
13.2
50
13.7
2.7
65
17.7
2.7
80
19.7
2.7
100
32.7
7.7
200°C PN 40
180°C PN 16
Size
Meter
Insert
65
50
25
3.75
1.10
0.35
Dimension picture
Weights
Size
Meter
Insert
50
25
15
2.25
0.70
0.25
Typical head loss curve
Dimensions
Size of meter
Overall length L
Height
H
H
g
Width
B
40
20
10
2.25
0.70
0.25
DN
kg
kg
Sensus Metering Systems GmbH
Hannover D-30880 Laatzen • Meineckestraße 10
Weitere Informationen unter http://www.sensus.com
ML4300 GB • Seite 2 von 2
01/2005
80
70
40
6.00
1.60
0.25
100
100
60
9.00
2.40
0.40