Conductivity Conductivity Meters Meters Handheld conductivity meters Conductivity cells Portable conductivity meters Accessories Laboratory conductivity meters Electrical Conductivity The conductivity is a cumulative parameter for the ionic concentration of a solution. The more salt, acid or alkali in a solution, the greater its conductivity. The unit of conductivity is S/cm. The scale for aqueous solutions begins with pure water at a conductivity of 0.05 µS/cm (25°C). Naturally occurring waters such as drinking water or surface water have a conductivity in the range 100 - 1000 µS/cm. The upper end of the scale is reached by some bases such as potassium hydroxide solutions with a conductivity of just over 1000 mS/cm. Conductivity of aqueous solutions µS/cm 0,1 mS/cm 1 10 100 1 10 100 1000 Feedwater for high-pressure boilers Fully deionized water (ion exchanger) Deionized water Drinking water Wastewater Surface water Brackish water, sea water In practice conductivity measurements are used for applications such as monitoring plants in which ultrapure water is produced and determining the salinity of sea water. Industrial process water Concentrated acids and bases Conductivity is measured by making a measurement of the electrical resistance. The simplest kind of measuring cell used consists of two similar electrodes. An alternating voltage applied to one of the electrodes causes the ions in the solution to migrate towards the electrodes. The more ions in the solution, the greater the current which flows between the electrodes. The instrument measures the current and uses Ohm's law to calculate first the conductance of the solution and then - by taken the cell data into account - the conductivity. Literature 76 Further information on this subject can be requested from WTW: Application reports Offprints Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Laboratory & Field ORP pH General Features Conductivity Meters ISE Conductivity meters for every application Quality in a set of three - Simple to use - Proven with memory function - All-rounder with interface Portable conductivity meters Classic 82 robust, shockproof, waterproof, portable, conductivity measurement at depths down to 100 m Laboratory conductivity meters inoLab® – top quality in 3 stages - Simple and reliable - Compact and communicative - Flexible and powerful Portable conductivity meters Conductivity meter accessories ❍ Flow-thru cells ❍ Stands and cell holders ❍ Calibration and testing agents For documentation Software, printer and accessories Further instruments for conductivity measurement BOD 94 94 95 180 from page 96 Software, Printers Turbidity Multi-parameter instruments 88 89 89 Respiration Sample Preparation ❍ Standard cells ❍ Special cells 84 Colony Counter Conductivity cells 78 Conductivity Handheld conductivity meters MultiParameter from page Photometry Model Oxygen (D.O.) Handheld conductivity meters Customer Service Laboratory conductivity meters Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 77 General Information about handheld conductivity meters can be found on pages 14 - 17. Conductivity Handheld Conductivity Meters Meters Cond 315i, Cond 330i and Cond 340i NEW Features Handy Dust- and waterproof Easy to use GLP-conform Low-power system allows continuous operation for up to 2500 h Pocket-size precision Universal conductivity meters with large multifunction display for measurement of conductivity, temperature, salinity and total dissolved solids. With the proven dirt-insensitive Tetracon® 4-electrode system they offer the highest degree of precision and operating comfort. Long usability Complete in SET 78 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 General Features Cond 315i, Cond 330i, Cond 340i Laboratory & Field Handheld Conductivity Meters ISE ORP pH handy · waterproof · GLP-conform Oxygen (D.O.) Cond 315i: MultiParameter Conductivity The simple conductivity meter for meeting higher demands. With only 5 keys for error-free measurement with parallel temperature measurement, automatic temperature compensation, 4-electrode measuring technology Cond 330i: Respiration Sample Preparation BOD Robust and waterproof handheld conductivity meter for battery operation; with parallel temperature display, integrated datalogger, GLP supporting functions, automatic and manual temperature compensation with linear temperature function and non-linear function for ultrapure water and natural waters according to DIN 38 404 and EN 27 888. The temperature compensation can be switched off; either 20 °C or 25 °C can be selected as the reference temperature Colony Counter Cond 340i: Photometry As Cond 330i, but with additional analog and digital RS 232 output and optional mains power supply IP 66 IP 67 3 Year Warranty Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Customer Service Software, Printers Turbidity Cond 315i 79 SET Equipment SET equipment for Cond 315i, Cond 330i and Cond 340i • Professional case with built-in measuring set-up and separate compartment for measuring cell and accessories • Conductivity meter with batteries • Measuring cell as chosen • KCl solution 0.01 mol/l for system checks • Stand and measuring beaker • Plug-in power supply (only Cond 340i) • Operating instructions Each handheld conductivity meter is available in a complete equipment set Technical Data Model Cond 315i Measuring range/ resolution Conductivity Accuracy (±1 digit) Cond 330i Cond 340i 0.0 µS/cm … 500 mS/cm in 5 ranges or AutoRange 0.00 µS/cm ... 19.99 µS/cm (for K=0.1 cm-1) 0.000 µS/cm ... 1.999 µS/cm (for K=0.01 cm-1) Temperature Salinity TDS Resistivity 0.0 µS/cm … 500 mS/cm with 5 ranges in AutoRange 0.00 µS/cm ... 19.99 µS/cm (for K=0.1 cm-1) -5.0 °C ... +105.0 °C 0.0 … 70.0 – 0.00 ... 1999 MΩcm Conductivity Temperature ±0,5 % of value ±0.1 K ±0.5 % of value ±0.1 K Ref. temperature Tref 25 °C -5.0 °C … +105.0 °C 0.0 … 70.0 0 … 1999 mg/l 0.000 ... 1999 MΩcm 20 or 25 °C, selectable Cell constant Fixed 0.475 cm-1, 0.1 cm-1 0.475 cm-1 0.1 cm-1 and 0.01 cm-1 fixed and 0.25 ... 2.5 cm-1 and 0.09 ... 0.11 cm-1 adjustable Temperature compensation Automatic, can be switched off Automatic, can be switched off Temperaturecoefficient • Non-linear function for natural waters (nLF) to EN 27 888 (DIN 38 404) and ultrapure water function • No compensation • Non-linear function for natural waters (nLF) to EN 27 888 (DIN 38 404) and ultrapure water function • Linear compensation from 0.01 ... 2.99%/K • No compensation Display LCD display 60 x 45 mm visible area, simultaneous display of measurement, temperature and special characters Data storage – Data output Via display Via display or interface Interface – Self-configuring analog output 0 ... 2 V corresponding to display, or RS 232 bi-directional interface Operating time Mains operation – Continuous operation from mains supply 500 data sets (measurement, temperature, date/time, identity no.); time-controlled storage at 7 intervals 5 s ... 60 min, non-volatile data storage Battery operation = 500 ... 2500 h* with 4 x 1.5 V batteries with AutoSwitchOff after 1 h (except logger operation) *depending on conductivity 80 Protection type IP 66 and IP 67 to IEC 529 Dimensions 172 x 80 x 37 mm (H x B x D) Weight Approx. 300 g Certified to CE, TÜV/GS, UL and/or cETLus, CUL Warranty 3 years for the instrument Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Robust and waterproof battery-operated handheld conductivity meter 2C10-000 Cond 330i Robust and waterproof battery-operated handheld conductivity meter with datalogger 2C20-000 Cond 340i Robust and waterproof battery-operated handheld conductivity meter with datalogger and serial interface 2C30-000 Cond 340i Robust and waterproof handheld conductivity meter with datalogger and serial interface, for mains operation 2C30-010 Ordering Information SETs Order No. Cond 315i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C10-001 Cond 330i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C20-001 Cond 340i Handheld conductivity meter, including conductivity cell, professional case and accessories 2C30-001 Cond 340i Handheld conductivity meter with mains power supply, including conductivity cell, professional case and accessories2C30-011 Laboratory & Field Photometry Handheld Conductivity Meters SETs BOD Order No. Cond 315i Respiration Sample Preparation Handheld Conductivity Meters Colony Counter Ordering Information MultiParameter Conductivity Oxygen (D.O.) ISE ORP Conductivity measuring kit according to USP 24, with stainless steel flow-thru vessel for pharmaceutical water (see page 95). pH General Features Handheld Conductivity Meters 4-electrode conductivity measuring cell 4-electrode conductivity measuring cell with 3 m cable Ultrapure water conductivity cell SET ordering example Cond 330i + TetraCon® 325-3 conductivity cell 1 2 4 2C20-001 2 Please refer to page 88 for conductivity cells and page 94 ff. for other accessories Customer Service Note: Other conductivity cells in SET and instrument versions for 120 VAC/60 Hz are available on request Software, Printers TetraCon® 325 TetraCon® 325-3 LR 325/01 Turbidity Conductivity cells – please select one Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 81 General Information about portable conductivity meters can be found on pages 18 - 19. Conductivity Portable Conductivity MetersMeters ProfiLine LF 197 and ProfiLine LF 197-S Features Robust Shockproof Waterproof Portable Reliable Standard conductivity measurement and conductivity measurement at depths down to 100 m 82 WTW portable conductivity meters The WTW conductivity meters of the ProfiLine LF 197 series are both hose-proof (IP 66) and submersible (IP 67). They convince because of their high degree of operator comfort and foolproof operator guidance via the large multifunctional display. They are equipped with a carrying/support handle and carrying strap as standard. The portable conductivity meters are available in 2 versions: ProfiLine LF 197: ProfiLine conductivity meter, extremely robust, hose-proof (IP 66) and submersible (IP 67), for connection of TetraCon® 325 4-electrode measuring cells and depth armature TA 197 LF with up to 100 m cable, with large multifunctional display for temperature and measurement, automatic temperature compensation, selectable reference temperature of 20 °C or 25 °C, built-in memory, TDS and salinity measurements, RS 232 digital IP 66 IP 67 output, integrated carrying and support handle, built-in electrode storage sleeve, for rechargeable battery and mains operation, and including plug-in power supply and carrying strap ProfiLine LF 197-S: As ProfiLine LF 197 but with 2 analog outputs corresponding to display for conductivity and temperature values 3 Year Warranty Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Laboratory & Field General Features Portable Conductivity Meters Accessories for conductivity measurement at depths down to 100 m ORP pH Conductivity depth armature TA 197 LF with built-in temperature sensor, up to 100 m cable with waterproof plug (IP 67), pressure-resistant steel armoring (material VA 1.4571) with screw-off protective hood, pressure-resistant to max. 10 bar, fits into 2" boreholes Conductivity Temperature Salinity TDS 0.0 µS/cm ... 500 mS/cm in 5 ranges, additional 0.00 .. 19.99 µS/cm (at K=0.1 cm-1) -5.0 ... 99.9 °C/ ±0.1 K 0.0 ... 70.00 0 ... 1999 mg/l ProfiLine LF 197-S Accuracy (± 1 digit) Conductivity Temperature ±0.5% of value ±0.1 K Ref. temperature 20 °C or 25 °C, selectable Cell constant 0.1 cm-1 fixed and 0.45 ... 1.30 cm-1, adjustable Temperature compensation Automatic or manual Temperature coefficient • Non-linear function for natural waters to EN 27 888 (DIN 38 404) • Linear compensation from 0.50 ... 3.00 %/K • No compensation Display LCD display 60 x 35 mm visible area, simultaneous display of measurement, temperature, special characters Data storage Ring memory for 50 pairs of measurements (measurement, temperature) with data protection Data output Via display or interface Interface Unidirectional RS 232 interface Operating time Continuous operation from plug-in mains supply; or 150 ... 800 hours with rechargeable batteries (depends on conductivity) with AutoSwitchOff after 1 h Protection type IP 66 and IP 67 to IEC 529 Dimensions 230 x 185 x 90 mm (B x D x H) Weight Approx. 1.5 kg Certified to CE, TÜV/GS, UL, CUL Warranty 3 years for the instrument Oxygen (D.O.) ProfiLine LF 197 Measuring range/ resolution BOD MultiParameter Conductivity Model ISE Technical Data Portable conductivity meters Order No. ProfiLine LF 197 Robust, waterproof, submersible conductivity meter 300 350 ProfiLine LF 197-S As ProfiLine LF 197, but additionally with 2 analog recorder outputs 300 351 Note: 120 VAC / 60 Hz versions on request Turbidity Ordering Information Photometry Colony Counter Respiration Sample Preparation Unidirectional RS 232 interface 2 analog recorder outputs for measurement and temperature output corresponding to display 4-electrode conductivity depth armatures with built-in temperature sensors, cable (length optional) with waterproof plug (IP 67), VA 1.4571 steel armoring and screw-off protective hood, pressure resistant to max. 10 bar, fits into 2” boreholes Cable length Order No. Cable length Order No. 25 m 301 980 TA 197 LF-60 60 m 301 982 TA 197 LF-40 40 m 301 981 TA 197 LF-100 100 m 301 983 Please refer to page 88 for conductivity cells and page 94 ff. for other accessories Customer Service TA 197 LF-25 Software, Printers Depth armatures for conductivity measurements with ProfiLine LF 197 and ProfiLine LF 197-S Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 83 General Information about inoLab® laboratory instruments can be found on pages 20 - 25. Conductivity Laboratory Conductivity Meters Meters inoLab® Cond Level 1, inoLab® Cond Level 2, inoLab® Cond Level 3 inoLab® Level 1 Think innovative inoLab® Cond Level 1: simple and reliable Features Performance-oriented instrument range Simplified operator convenience Mainsindependent Suitable as bench and wall-mounted models Country-specific units ISO-conform documentation Application-oriented displays 84 Routine laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. 20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). inoLab® Level 2 inoLab® Cond Level 2: compact and communicative Standard laboratory conductivity meter with large multifunctional display, parallel temperature display and automatic temperature compensation. An integral measurement store with logger function and a real-time clock allow QA-conform data acquisition. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. 20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). IP 43 MultiCal® automatic calibration AutoRead automatic drift control for stable and reproducible measurements See innovative Feed and on/off keys keys for controlling the built-in printer 3 Year Warranty Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 General Features Touch innovative inoLab® Level 3 Laboratory & Field Laboratory Conductivity Meters pH inoLab® Cond Level 3 with Teminal Level 3 or PC software: flexible and powerful ORP High-performance laboratory conductivity meter with graphics display and digital recorder function, parallel display of temperature and automatic temperature compensation. An integral measurement store with logger function and a real-time clock allow QA-conform data acquisition. The optional built-in printer allows data printout on thermal paper accepted for use in official documents. Oxygen (D.O.) ISE 20 °C or 25 °C can be set as reference temperature. Both TDS and salinity measurements are possible as well as conductivity and temperature. The ability to set different cell constants means that other special conductivity cells can be connected as well as the TetraCon® 325 4-electrode conductivity cell and LR 325/01 ultrapure water conductivity cell (see page 93). Automatic memory function if bar-code reader is used AutoRead automatic drift control for stable and reproducible measurements RUN/ENTER triggers the measuring process IP 43 Selectable instrument language Extended GLP functions Limit input with acoustic alarm Meets all the requirements of USP 24 3 Year Warranty Free-of-charge software downloads for inoLab® pilot or terminal Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 BOD Respiration Sample Preparation Colony Counter Connection of bar-code reader or PC keyboard Photometry Graphic evaluation possible Turbidity Built-in digital plotter Software, Printers Features Customer Service Terminal Level 3 MultiParameter Conductivity An PC keyboard interface allows an external keyboard or a barcode reader to be connected. 85 Technical Data for laboratory conductivity meters Modelle Cond Level 1 Range/ Resolution Conductivity Cond Level 2 Cond Level 3 Temperature Salinity TDS: Resistivity: 0.0 µS/cm ... 500 mS/cm in 5 measuring ranges or AutoRange additionally for K = 0.1 cm-1: 0.00 µS/cm ... 19.99 µS/cm K = 0.01 cm-1: 0.000 µS/cm ... 1.999 µS/cm -5.0 ... +99.9 °C 0.0 ... 70.0 0 ... 1999 mg/l 0.000 ... 1999 MΩcm Accuracy (±1 digit) Conductivity Temperature ±0.5% of value ±0.1 K Reference temperature 20 °C or 25 °C, selectable Cell constants 0.475 cm-1, 0.1 cm-1 and 0.01 cm-1 fixed, freely selectable 0.25 ... 2.5 cm-1 and 0.09 ... 0.11 cm-1 Temperature compensation Automatic, manual or switched off Temperature coefficient • Non-linear function for natural water to EN 27 888 (DIN 38 404) • Linear compensation from 0.001 ... 2.999%/K • No compensation Calibration With 0.01 mol KCl Real-time clock – Non-volatile Data memory – 200 records (measurement, temperature) date/time, ident. no., time-controlled storage interval 5 s ... 60 min 2000 records (measurement, temperature) date/time, ident. no., time-controlled storage interval 1 s ... 60 days Data output Display Display or interface Display, PC or interface Analog interface – Self-configuring as analog output corresponding to display or as RS 232 bidirectional interface Digital interface – RS 232 bidirectional interface Operating time/ Energy supply 2500 h with 4 x 1.5 V standard batteries or mains supply Protection type IEC 529 / IP 43 without built-in printer Dimensions (B x D x H in mm) 230 x 210 x 70 300 x 250 x 70 300 x 250 x 70 Weight Approx. 1.3 kg Approx. 1.6 kg Approx. 1.6 kg Certified to CE, TÜV/GS, UL, CUL Warranty 3 years for the instrument With terminal: universal plug-in power supply 230 VAC or 120 VAC Without terminal: via PC interface 86 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Laboratory & Field ORP pH General Features Laboratory Conductivity Meters 1C20-010 inoLab® Cond Level 2 Compact precision conductometer with additional built-in printer for GLP-conform documentation 1C21-010 inoLab® Cond Level 3 Flexible and powerful precision – the intelligent conductivity measuring place consisting of multifunction box and universal terminal, with PC software/connection cable 1C30-010 1C31-010 inoLab® Cond Level 3 The integrated conductivity measuring place with PC software/connection cable; without printer/terminal 1C32-000 MultiParameter inoLab® Cond Level 3 The intelligent conductivity measuring place with additional built-in printer 1C10-011 inoLab® Cond Level 2 Including cell, passive multifunction box and accessories 1C20-011 inoLab® Cond Level 2 Including built-in printer, cell, passive multifunction box and accessories 1C21-011 inoLab® Cond Level 3 Including terminal, cell and accessories 1C30-011 inoLab® Cond Level 3 With built-in printer, including terminal, cell and accessories inoLab® Cond Level 3 Without printer/terminal, with PC software/connection cable, cell and accessories 1C31-011 1C32-001 Conductivity cells – please select one TetraCon® 325 TetraCon® 325-3 LR 325/01 4-electrode conductivity measuring cell 4-electrode conductivity measuring cell with 3 m cable Ultrapure water conductivity cell SET ordering example inoLab® Cond Level 1 + conductivity measuring cell LR 325/01 1 2 4 1C10-011 4 Note: Other measuring cells in SET and instrument versions for 120 VAC/60 Hz are available on request Customer Service Software, Printers Turbidity Please refer to page 88 for conductivity cells and page 94 ff. for other accessories Respiration Sample Preparation Including cell, passive multifunction box and accessories Colony Counter Order No. inoLab® Cond Level 1 BOD Ordering Information for inoLab® conductivity meters SETs – “ready to go” inoLab® Cond SETs Oxygen (D.O.) 1C10-010 inoLab® Cond Level 2 Compact precision conductometer with serial interface Conductivity Order No. inoLab® Cond Level 1 Simple and reliable conductometer for routine work Photometry inoLab® laboratory conductometers ISE Ordering Information for inoLab® conductivity meters Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 87 Conductivity Conductivity cells Meters TetraCon® TetraCon® conductivity cells For more than 50 years WTW has been one of the leading manufacturers worldwide of precision conductivity meters and cells. The TetraCon® 4-electrode system is the perfect result of a logical, practice-oriented further development and sets a new standard for professional conductivity measurements. In comparison with conventional measuring cells with 2 electrodes, the TetraCon® conductivity cell offers numerous technical advantages: • Highest degree of precision and linearity by optimized cell geometry • Extremely large measuring range with just one cell • Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes • With built-in temperature sensor as standard • Smallest immersion depth possible • Ideal sample exchange – no dead volume • No measuring errors even with very dirty electrode – contact resistance on the electrode surface is automatically compensated • No measuring errors from cable influences • No measuring errors from primary or secondary polarization effects • No measuring errors from alteration to the electrical marginal field during contact with base or side walls • No danger of breakage owing to robust epoxy casting technique Special conductivity depth armatures for ProfiLine LF 197 and ProfiLine LF 197-S can be found on page 83 88 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 4-electrode cell made of glass with built-in temperature sensor. For universal use, even in partially aqueous or highly aggressive media. 4-electrode cell with built-in temperature sensor for measurements in pastes, creams and emulsions With built-in temperature sensor and flow-thru vessel D 01/T for the measurement of small conductivities (<1 µS/cm), e.g. boiler feed water or deionized water. Electrode material graphite Shaft material epoxy Shaft length 120 mm Cell constant K = 0.475 cm-1 Diameter 15.3 mm Cable length 1.5 m Measuring range 1 µS/cm ... 2 S/cm* Temperature range 0 ... 90 °C Electrode material platinum Shaft length 120 mm Cell constant K approx. 1 cm-1 Diameter 20 mm Cable length 1.5 m Measuring range 1 µS/cm ... 1 S/cm* Electrode material graphite Shaft material epoxy Shaft length 120 mm Cell constant K = 0.491 cm-1 Diameter 15.3 mm Cable length 1.5 m Measuring range 1 µS/cm ... 2 S/cm* Electrode material V4A steel Shaft material V4A steel Shaft length 120 mm Cell constant K = 0.1 cm-1 Diameter 12 mm Cable length 1.5 m Min./max. immersion depth 35/110 mm and flow-thru measurements Measuring range 0.001 µS/cm ... 300 µS/cm * Measuring range depends on particular instrument Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Laboratory & Field Colony Counter 4-electrode cell with built-in temperature sensor Photometry Ultrapure water conductivity cell LR 325/01 Turbidity Special conductivity cell TetraCon® 325/S Software, Printers Special conductivity cell TetraCon® 325/Pt Customer Service Standard conductivity cell TetraCon® 325 Respiration Sample Preparation BOD MultiParameter Conductivity Oxygen (D.O.) ISE ORP pH General Features Conductivity Cells 89 Trace conductivity cell LR 325/001 With built-in temperature sensor and flow-thru vessel for the measurement of conductivity and resistance in boiler feed water or deionized water as well as in partially aqueous and nonaqueous media. Flow-thru vessel Electrode material Shaft material Shaft length Cell constant K= V4A steel V4A steel V4A steel 120 mm 0.01 cm-1 Conductivity flow-thru cell TetraCon® DU/T Conductivity measuring cell LDM 4-electrode cell with built-in temperature sensor for standard applications in laboratories and production. Connection via 10 mm dia. hose nozzles. For small sample volumes with injection syringe for sampling Electrode material graphite Shaft material epoxy Length 155 mm Filling volume 7 ml Cell constant K = 0.778 cm-1 Measuring range 1 µS/cm ... 2 S/cm* Adapter cable KKDU 325, length 1 m, is necessary for the connection. Cell constant K approx. 150 cm-1 Dialysis conductivity cell TetraCon® DU/TH Conductivity flow-thru cell LDM/S As TetraCon‚ DU/T, but for dialyzers with connectors to DIN 58 352 (Hansen connectors). For column chromatography or minute sample volumes. Adapter cable KKDU 325, length 1 m, is necessary for the connection. Cell constant K approx. 15 cm-1 Adapter cable K-LDM with built-in 30 kΩ fixed resistor is necessary for the connection. Volume Temperature approx. 4 ml 0 ... 90 °C Diameter 20 mm Cable length 1.5 m Min./max. immersion depth 35/110 mm and flow-thru measurements Measuring range 0.0001 µS/cm ... 30 µS/cm 90 * Measuring range depends on particular instrument Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Laboratory & Field pH General Features Selection Guide ORP 2 2 2 2 2 2 2 2 2 ● ● ● 5 5 5 5 5 5 5 5 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● BOD ● ● ● ● 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 ● ● ● ● ● ●* ● ● ● ● 4 4 4 4 5 5 5 5 ● ● 4 4 4 4 4 4 4 4 5 5 5 5 ● ● ● 4 4 4 4 4 4 4 4 Adapter (possible conversion with cell constants) is required: Adapter cable KLF 10 Adapter cable K/LTA together with temperature sensor TFK 325 or TFK 150 Adapter cable K/LDM Connection cable KKDU Connection cable KKDU 325 * not for Cond 315i Customer Service Software, Printers Turbidity 1 2 3 4 5 Respiration Sample Preparation ● Colony Counter ● ● Photometry ● MultiParameter 3 3 ● ISE 2 2 2 Oxygen (D.O.) 1 1 1 1 1 1 1 Conductivity LF 597 ● ● ● LF 197 ● 2 2 2 2 2 2 2 2 2 LF 196 2 2 2 ● ● ● ● ● ● ● ● ● ● ● MultiLine® P3 pH/LF, pH/Cond 340i 2 2 2 ● ● ● ● ● ● ● ● ● ● ● MultiLine® P4, Multi 340i 2 2 2 2 2 2 MultiLab® P4/P5 2 2 2 ● ● ● ● ● ● ● ● MultiLab® 540 2 2 2 LF 3000 2 2 2 LF 539 inoLab® Cond, pH/Cond, Multi 2 2 2 LF 538 Cond 315i/330i/340i 2 2 2 LF 537 LF 330/340A LF 318 LF 315 LF 96 1 1 1 1 1 1 1 LF 320/323/325 LTA LTA 1 LTA 01 LTA 10 LTA 100 LTA/S LTA/KS LR 01/T LR 001/T LDM LDM/S KLE 1 ● KLE 1/T KLE 315 TetraCon® 96 TetraCon® 96-1,5 TetraCon® 96-ATetraCon® 96 A-4 TetraCon® 96-T-100 m TetraCon® 325 TA 197 LF TetraCon® L TetraCon® 325/Pt TetraCon® DU/T TetraCon® DU/TH KDU 1/T KDU 1/TH LR 325/01 LR 325/001 TetraCon® 325/S LF 95 Measuring cell LF 90 Selection Guide Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 91 Ordering Information Standard conductivity cells Order No. KLE 315 2-electrode conductivity cell with 1.5 m cable and waterproof plug 301 965 TetraCon® 325 4-electrode conductivity cell with built-in temperature sensor, K = 0.475 cm-1 with waterproof plug (IP 68) and 1.5 m cable 301 960 TetraCon® 325-3 As TetraCon®‚ 325, but cable length 3 m 301 970 LTA 1 Glass/platinum 2-electrode conductivity cell, K approx. 1 cm-1 (adapter cable K/LTA required) 301 310 LTA 100 Glass/platinum 2-electrode conductivity cell with adjustable cell constant, K = 1 cm-1 (adapter cable K/LTA required) 301 200 TetraCon® 96 4-electrode conductivity cell with built-in temperature sensor, K = 0.609 cm-1, 1 m cable 301 244 TetraCon® L Glass/platinum 4-electrode conductivity cell with built-in temperature sensor, K approx. 1.0 cm-1, for universal use, even in partially aqueous or highly aggressive inorganic media. 301 255 TetraCon® 325/Pt Glass/platinum 4-electrode conductivity cell with built-in temperature sensor; can also be used in partially aqueous or highly aggressive solutions, K approx. 1 cm-1 301 964 For conductivity measurements at depths down to 20 m TetraCon® 325-6 As TetraCon® 325, but cable length 6 m 301 971 TetraCon® 325-10 As TetraCon® 325, but cable length 10 m 301 972 TetraCon® 325-15 As TetraCon® 325, but cable length 15 m 301 973 TetraCon® 325-20 As TetraCon® 325, but cable length 20 m 301 974 Suitable accessories A 325/K Plastic armoring with protective hood 903 830 A 325/S Steel armoring with stainless steel protective hood, material no. 1.4571 903 831 For conductivity measurements at depths down to 100 m TA 197 LF-25 4-electrode conductivity depth cell with built-in temperature sensor, 25 m cable with waterproof plug (IP 68), pressure resistant steel armoring and screw-off protective hood, fits into 2” boreholes 301 980 TA 197 LF-40 As TA 197 LF-25, but with 40 m cable 301 981 TA 197 LF-60 As TA 197 LF-25, but with 60 m cable 301 982 TA 197 LF-100 As TA 197 LF-25, but with 100 m cable 301 983 Ordering Information Flow-thru conductivity cells Order No. TetraCon® DU/T Flow-thru cell with built-in temperature sensor for all standard applications in laboratories and production, connection via 10 mm dia. hose nozzles, K = 0.778 cm-1, without cable 301 252 TetraCon® DU/TH Flow-thru cell with built-in temperature sensor for checking dialyzers, connection via DIN 58 352 “Hansen connectors”, K = 0.778 cm-1, without cable 301 254 LDM/S Conductivity flow-thru cell for column chromatography or minute sample volumes, K = approx. 15 cm-1 301 750 KDU 1/T Conductivity flow-thru cell with built-in temperature sensor, for all standard applications in laboratories and production, connection via 10 mm dia. hose nozzles, K approx. 0. 8 cm-1, without cable 301 530 KDU 1/TH Flow-thru cell with built-in temperature sensor for checking dialyzers, connection via DIN 58 352 “Hansen connectors”, K approx. 0. 8 cm-1, without cable 301 535 92 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 General Features Ordering Information Laboratory & Field Conductivity Cells Conductivity cells for special applications Pure and ultrapure water measurements LTA 01 Glass/platinum 2-electrode conductivity cell for ultrapure water, K approx. 0.1 cm-1 301 410 LR 01/T Ultrapure water cell with built-in temperature sensor, with flow-thru vessel D 01/T as standard, K = 0.100 cm-1, with 1.5 m cable and waterproof plug 302 520 LR 001/T Trace conductivity cell with built-in temperature sensor and flow-thru vessel for the measurement of conductivity in boiler feed water or deionized water as well as in partially aqueous and non-aqueous media, K = 0.0100 cm-1, with 1.5 m cable 302 530 LR 325/001 Trace conductivity cell with built-in temperature sensor and flow-thru vessel for the measurement of conductivity in boiler feed water or deionized water as well as in partially aqueous and non-aqueous media, K = 0.0100 cm-1, cable with waterproof plug 301 962 pH 301 961 ORP Ultrapure water cell with built-in temperature sensor, K = 0.100 cm-1, with flow-thru vessel D 01/T and waterproof plug ISE LR 325/01 301 603 Special applications LDM Conductivity measuring cell for small sample volumes with injection syringe for sampling, K = approx. 150 cm-1, without cable 301 700 LTA 10 Glass/platinum 2-electrode conductivity cell for extremely high conductivity values, K approx. 10 cm-1 301 112 LTA Glass/platinum 2-electrode conductivity cell with special length, suitable for measurements in test tubes (13 mm dia.), K = approx. 1 cm-1 301 100 Connection cables and accessories KLF 10 Adapter cable for connection of 2-electrode conductivity cell and TFK 530 303 224 K/LTA Adapter cable for connection of 2-electrode conductivity cell and TFK 325 or TFK 150 301 429 K-LDM Adapter cable with built-in 30 kohm fixed resistor, length 1 m 301 430 KKDU Connection cable with 1 m cable 301 532 KKDU 325 Connection cable with waterproof plug and 1 m cable 301 963 TH 340 Telescopic extension for TetraCon® 325 ..., 1.5 ... 3 m, with sensor holder 402 802 Protective armoring 1 SM 325 2 TG/Oxi-LF 2 3 Colony Counter Photometry Turbidity Software, Printers 3 1 Shock-absorbing, rubber protective armoring with folding support and sensor cable clamping device Sleeve set, suitable for SM 325 protective armoring, consisting of electrode sleeve, holding device and additional carrying strap for field use. Can also be used for storing the sensor. FM 325/Oxi-LF Field armoring, specially designed for rough use on-site and in industry, extremely robust and shock-resistant thanks to protective armoring with integrated electrode sleeve, carrying handle and additional carrying strap with holding device, sensor cable clamping device and folding support for laboratory measurements Ordering Information Protective armoring Order No. SM 325 Shock-absorbing, rubber protective armoring 902 818 TG/Oxi-LF Sleeve set, suitable for protective armoring SM 325 902 812 FM 325/Oxi-LF Field armoring, specially for rough conditions 902 813 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Customer Service for safe on-site use Conductivity 2-electrode conductivity cell for pastes, K = 0.901 cm-1 MultiParameter LTA/KS BOD 301 602 Respiration Sample Preparation 4-electrode conductivity cell for pastes and emulsions with built-in temperature sensor, K = 0.491 cm-1, with waterproof plug and 1.5 m cable Oxygen (D.O.) Conductivity measurements in pastes and emulsions TetraCon® 325/S 93 Software and printers Information is given on pages 180 - 183. Conductivity Conductivity Meter Accessories Meters ❍ ❍ ❍ ❍ Protective armoring Flow-thru vessels Stands and cell holders Calibration and testing agents page 93 94 94 95 Flow-thru vessels Ordering Information for LTA 1, LTA, LTA 01 and TFK 530 D 530 Order No. Flow-thru vessel of transparent PVC, suitable for conductivity cells and temperature sensors, I.D. 44 mm, V*=97 ml 108 060 Flow-thru vessel of transparent PVC, I.D. 18 mm, V*=13 ml 203 730 for TetraCon® 325 D 201 for TetraCon® 96-1,5, TetraCon® 96 and KLE 1 D 1/T Flow-thru vessel, glass I.D. 24 mm, V*=36 ml 302 730 for LR 01/T and LTA 01 D 01/T Flow-thru vessel, glass I.D. 18 mm, V*=17 ml 302 750 Flow-thru vessel I.D. 27 mm, V*=40 ml 302 700 for LTA 100 D 100 V*: filling volume without sensor Stand and cell holder Stand STH 650 Benchtop stand with flexible electrode holder for measuring cells and temperature sensors Ordering Information Benchtop stand and cell holder STH 650 94 Benchtop stand with flexible electrode holder for pH electrodes, ion sensitive electrodes, reference electrodes, temperature sensors, oxygen sensors and TetraCon® 325 conductivity cells Order No. 109 809 Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 Calibration and testing agents Shelf life 2 years, NIST traceable with accuracy ±3% Calibration standard 15 µS/cm Shelf life 1 year, NIST traceable with accuracy ±2% As USP Kit 1, but flow-thru vessel made of stainless steel instead of D01/T 300 568 Calibration agents KS 100µS Calibration standard 100 µS/cm, shelf life 2 years, NIST traceable with accuracy ±3% (300 ml) 300 578 KS 15µS Calibration standard 15 µS/cm, shelf life 1 year, NIST traceable with accuracy ±2% (300 ml) 300 579 EP/SET Calibration and platinization set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l, 30 ml platinizing solution, 1 calibration vessel), only for platinized cells 300 570 E/SET Calibration set (6 x 50 ml bottles calibration and control standard, KCl 0.01 mol/l) 300 572 Testing agents for conductivity meters 6R/SET/LAB 1 Testing set for checking the conductivity meters according to ISO 9000. Allows the measured values to be traced back to national standards. 302 870 Only for LF 3000, LF 539, LF 537 and MultiLab® P4/P5 Testing set for checking the conductivity meters according 302 872 to ISO 9000. Allows the measured values to be traced back to national standards. ISE Oxygen (D.O.) Customer Service 6R/SET/LAB 2 Colony Counter USP Kit 2 Photometry 300 569 Turbidity Kit for measuring the conductivity according to USP 24, consisting of LR 325/01 Ultrapure water cell, D01/T Glass flow-thru vessel, NIST traceable 15 µS standard with accuracy ±2% and 6R/SET/LabTesting set Respiration Sample Preparation Order No. USP Kit 1 Software, Printers Kit for measuring the conductivity according to USP 24 BOD Ordering Information Conductivity Calibration standard 100 µS/cm MultiParameter NEW ORP pH Kit for measuring the conductivity according to USP 24 This kit contains LR 325/01 Ultrapure water cell, D01/T Flow-thru vessel made of glass (USP-KIT 1) or stainless steel (USP-KIT 2), NIST traceable 15 µS standard with accuracy ±2% and 6R/SET/LabTesting set Laboratory & Field General Features Conductivity Meter Accessories Wissenschaftlich-Technische Werkstätten GmbH & Co. KG · Dr.-Karl-Slevogt-Straße 1 · 82362 Weilheim · Germany · Tel.: +49 (0) 881-1 83-0 · Fax: +49 (0) 881-62 53 9 95
© Copyright 2026 Paperzz