Ordering information AC-DC Power Supplies Configurable Type MAX series M1O - OOOO-OO-OO 1 6 7 8 9 10 11 M3T - OOOOOOOO-OO-OO 1 2 Recommended EMI/EMC Filter MAX1600F NAC-30-472 R 3 4 5 6 7 MAX1600T TAC-10-683 MAX3200T TAC-20-683 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The EMI/EMC Filter is recommended to connect with several devices. MAX 8 9 10 11 1 Abbreviation type name of MAX series M1F : MAX1600F M1T : MAX1600T M3T : MAX3200T 2 Slot 8 Output module 3 Slot 7 Output module 4 Slot 6 Output module 5 Slot 5 Output module 6 Slot 4 Output module 7 Slot 3 Output module 8 Slot 2 Output module 9 Slot 1 Output module 10 Parallel code 11 Series and option code *7 Refer to instruction manual 8 7 6 5 4 3 2 1 Slot * The number of slot is different depending on the model. SPECIFICATIONS INPUT OUTPUT FUNCTION ISOLATION MAX ENVIRONMENT SAFTY AND NOISE REGULATIONS MODEL VOLTAGE[V] FREQUENCY[Hz] AC100V *1 CURRENT[A] AC200V *2 AC100V *1 POWER FACTOR AC200V *2 INRUSH CURRENT AC100V [A] AC200V AC100V *1 EFFICIENCY[%] AC200V *2 LEAKAGE CURRENT [mA] *3 *4 NUMBER OF SLOT TOTAL MAXIMUM AC90 - 150V *5 POWER[W] AC170 - 264V *5 START-UP TIME AC100V *1 [ms] AC200V *2 HOLD-UP TIME[ms] *1 ALARM INPUT-OUTPUT, RC INPUT-FG OUTPUT, RC-FG OPERATING TEMP.,HUMID. AND ALTITUDE *5 STORAGE TEMP.,HUMID. AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE HARMONIC ATTENUATOR CASE SIZE OTHERS WEIGHT COOLING METHOD *6 MAX1600F (M1F) MAX1600T (M1T) MAX3200T (M3T) AC170 - 264 3f AC170 - 264 3f AC85 - 264 1f / DC120 - 350 47 - 63 47 - 63 47 - 63 19typ 10typ 6.5typ 13typ 0.99typ 0.95typ 0.95typ 0.95typ 20/40typ (Primary inrush current/Secondary inrush current) 40/40typ (Primary inrush current/Secondary inrush current) 40typ 40typ 78typ 82typ 85typ 85typ 1.5max 2max 2max 4 4 8 1500 1600 1600 3200 700typ 500typ 500typ 500typ 20typ 20typ 20typ FAN ALARM FAN AND OPEN PHASE ALARM FAN AND OPEN PHASE ALARM AC3,000V 1minute, Cutoff current=25mA, DC500V 50MW min (At Room Temperature) (Cutoff current = 100mA : MAX3200T) AC2,000V 1minute, Cutoff current=25mA, DC500V 50MW min (At Room Temperature) AC500V 1minute, Cutoff current=100mA, DC500V 50MW min (At Room Temperature) -20 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max 19.6m/s 2 , 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s 2 , 11ms, once each X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, Complies with DEN-AN (At only AC input) Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B Complies with FCC-A, VCCI-A, CISPR22-A and EN55011-A Complies with IEC61000-3-2 *8 200X97X300mm (WXHXD) 340X97X300mm (WXHXD) 200X97X300mm (WXHXD) [7.87X3.82X11.81 inches] [7.87X3.82X11.81 inches] [13.39X3.82X11.81 inches] 7kg max Forced cooling (built-in) 7kg max *1 It is a value when M1F-HFEC-00 (MAX1600F : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1500W. The value changes by composing the output modules. *2 It is a value when M1F-HFEC-00 (MAX1600F : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1600W or M1T-HFEC-00 (MAX1600T : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1600W or M3T-HHFFEECC-00 (MAX3200T : 5V80AX2, 12V34AX2, 15V27AX2, 24V17AX2) outputs 3200W. The value changes by composing the output modules. 14kg max *3 *4 *5 *6 *7 *8 Complies with IEC60950 at AC240V 60Hz. Each output module is insulated. Refer to derating. Case size contains neither the terminal blocks (cover) nor the screw. Please contact us about safety approvals for the model with option. Please contact us about class C. MAX-2 MAX_E.indd 2 15.6.18 5:57:51 PM MAX series Output module specifications CODE ITEM Number of slots used VOLTAGE[V] CURRENT[A] LINE REGURATION[mV]max LOAD REGURATION[mV]max 0 to +50C*1 RIPPLE [mV]max -20 to 0C*1 0 to +50C*1 RIPPLE NOISE [mV]max -20 to 0C*1 0 to +50C TEMPRATURE COEFFICIENT[mV]max -10 to +50C *2 DRIFT[mV]max OUTPUT VOLTAGE SETTING[V] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] OUTPUT CURRENT IN PARALLEL[A] TWO MODULES IN PARALLEL THREE MODULES IN PARALLEL FOUR MODULES IN PARALLEL FIVE MODULES IN PARALLEL SIX MODULES IN PARALLEL SEVEN MODULES IN PARALLEL EIGHT MODULES IN PARALLEL *3 F E D C B A 1 1 1 1 1 1 15 12 7.5 5 3.3 2 27 34 54 80 80 80 60 48 30 20 20 20 120 100 60 40 40 40 120 120 120 80 80 80 160 160 160 140 140 140 150 150 150 120 120 120 180 180 180 160 160 160 150 120 75 50 40 40 225 180 120 75 60 60 60 48 30 20 12 12 2.00 - 2.06 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 1.98 - 2.20 2.64 - 3.63 4.00 - 5.50 6.00 - 8.25 9.60 - 13.20 12.00 - 16.50 Works over 105% of rated current automatic recovery 4.00 - 5.50 4.00 - 5.50 5.75 - 7.00 8.63 - 10.50 13.80 - 16.80 17.25 - 21.00 G 1 18 22 72 150 120 160 150 180 180 270 72 18.00 - 18.72 14.40 - 19.80 144 216 300 360 444 516 600 40 60 80 100 120 140 160 144 216 300 360 444 516 600 144 216 300 360 444 516 600 97 146 195 243 292 341 390 61 92 125 153 196 217 250 49 73 100 122 149 173 200 H 1 24 17 96 150 120 160 150 180 240 360 96 24.00 - 24.96 19.20 - 26.40 I 1 28 14.5 112 180 120 160 150 180 280 420 112 28.00 - 29.12 22.40 - 30.80 O 1 BLANK PANEL MAX 20.70 - 25.20 27.60 - 33.60 32.20 - 39.20 31 46 63 77 92 107 127 26 40 54 66 80 94 108 - *1 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM101). Ripple and Ripple Noise is measured by using measuring board with capacitor of 470mF between 20mm to 100mm from the output terminal. *2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. *3 Modulars in parallel are built to order and are not possible for the user to assemble them. Block diagram MAX1600F VARIOUS SIGNALS FUSE INPUT VOLTAGE AC85 - 264V (1f) AC250V 50A REMOTE ON/OFF NOISE FILTER INRUSH CURRENT LIMITING ACTIVE FILTER RECTIFIER AND FILTER OUTPUT MODULE 2-4SLOTS DC OUTPUT FG INTERNAL REGURATOR FAN ALARM MAX1600T / MAX3200T FUSE AC250V 15A (MAX1600T) AC250V 30A (MAX3200T) INPUT VOLTAGE AC170 - 264V (3f) MAX VARIOUS SIGNALS NOISE FILTER RECTIFIER INRUSH CURRENT LIMITING FILTER OUTPUT MODULE 2-4SLOTS (MAX1600T) 4-8SLOTS (MAX3200T) REMOTE ON/OFF DC OUTPUT FG OPEN PHASE INTERNAL REGURATOR FAN ALARM MAX-3 MAX-3 MAX_E.indd 3 15.6.18 5:57:52 PM MAX series MAX1600F / MAX1600T external view AC (L1) input (15) 9.5 16 16 13 [0.59] [0.37] [0.63] [0.63] [0.51] 27max Name plate [1.06] M5 Output terminal (-) input M5 AC (L) 20 AC (L2) FG FG AC (L3) 8-M4 Mounting Hole (Both sides) slot2 9 14 17 14 [0.37] [0.35] [0.55] [0.67] [0.55] (76) [2.99] [1.42] 36 [1.42] CN1 (9.5) [0.98] slot1 (24.8) M5 160t0.5 [6.3] 200 slot3 [1.42] Output terminal (+) (182) 36 [7.17] 36 slot4 MAX1600T 241t0.5 [9.49] 300 25 max Output voltage [0.98] adjustable potentiometer (VR1) [7.87] 13 [0.51] [0.79] AC (N) (15) 9.5 16 16 [0.59] [0.37] [0.63] [0.63] 35 [1.38] [11.81] MAX1600F Input terminal cover 67t0.5 Mounting Hole (Both sides) [2.64] 97 [3.82] Tolerance : t1 [t0.04] Weight : 7kg max PCB Material/thickness : FR-4/1.6mm [0.06] Chassis material : Stainless steel SUS430 Dimensions in mm, [ ]= inches 241t0.5 Mounting torque : 1.5N-m (16kgf-cm) max [9.49] Keep drawing current per terminal bellow 80A of output terminal. The housing for the remote sensing unused is mounted on CN1 of each output module. However, when the output module is connected in parallel, the housing is mounted on only master output module. ¶ Output terminal covers are appended. 15 8-M4 ¶ ¶ ¶ ¶ ¶ ¶ ¶ ¶ [0.59] MAX AIR FLOW 35 [1.38] MAX3200T external view AC(L3) 13 [0.37] [0.51] [0.59] 16 16 [0.63] [0.63] input AC(L2) AC(L1) 27max Name plate [1.06] M5 Output terminal(–) 150 t0.5 36 [1.42] 36 Output terminal(+) [1.42] slot8 12-M4 Mounting Hole (Both sides) slot7 [5.91] FG (15) 9.5 [13.39] 340 36 [1.42] [12.68] 36 slot5 [1.42] (322) slot6 150 t0.5 [5.91] [1.38] 300 [11.81] [0.98] Tolerance : t1 [t0.04] Weight : 14kg max PCB Material/thickness : FR-4/1.6mm [0.06] Chassis material : Stainless steel SUS430 241t0.5 Dimensions in mm, [ ]= inches [9.49] Mounting torque : 1.5N-m (16kgf-cm) max Keep drawing current per terminal bellow 80A of output terminal. The housing for the remote sensing unused is mounted on CN1 of each output module. However, when the output module is connected in parallel, the housing is mounted on only master output module. ¶ Output terminal covers are appended. 97 8-M4 Mounting Hole (Both sides) [3.82] adjustable potentiometer(VR1) 67t0.5 ¶ ¶ ¶ ¶ ¶ ¶ ¶ ¶ [9.49] 25max (76) [2.99] 35 241t0.5 Output voltage adjustable potentiometer(VR1) [2.64] [0.35] [0.55] [0.67] [0.55] [0.59] [0.37] 15 9 14 17 14 20 CN1 (9.5) [1.42] 36 slot1 MAX (24.8) 36 M5 [0.98] slot2 [1.42] slot3 [0.79] 36 [1.42] slot4 AIR FLOW 35 [1.38] MAX-4 MAX_E.indd 4 15.6.18 5:57:52 PM MAX series Function connector (CN1) pinassign CN1 1 3 5 7 9 2 4 6 8 10 12 11 Maiting connector and terminal of output module CN1 Connector Mating connector CN1 Terminal Mfr. Chain : SPHD-002T-P0.5 S12B-PHDSS PHDR-12VS Loose : BPHD-001T-P0.5 J.S.T : BPHD-002T-P0.5*1 *1 Ratchet Hand is nothing Pin connection and function of output module CN1 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 +M -M +S -S TRM -S RC2 -S RC3 ALM IOG TMP Function : +Output voltage monitoring : -Output voltage monitoring : +Remote sensing : -Remote sensing, Signal ground : Adjustment of output Voltage : -Remote sensing, Signal ground : Remote ON/OFF : -Remote sensing, Signal ground : Remote ON/OFF : Fan alarm (and open phase alarm)* : Inverter operation monitor : Thermal detection signal MAX *MAX1600T / MAX3200T MAX MAX-5 MAX-5 MAX_E.indd 5 15.6.18 5:57:53 PM
© Copyright 2026 Paperzz