MAX series

Ordering information
AC-DC Power Supplies Configurable Type
MAX series
M1O -
OOOO-OO-OO
1
6
7
8
9
10
11
M3T - OOOOOOOO-OO-OO
1
2
Recommended EMI/EMC Filter
MAX1600F NAC-30-472
R
3
4
5
6
7
MAX1600T TAC-10-683
MAX3200T TAC-20-683
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended to connect with several devices.
MAX
8
9
10
11
1 Abbreviation type name
of MAX series
M1F : MAX1600F
M1T : MAX1600T
M3T : MAX3200T
2 Slot 8 Output module
3 Slot 7 Output module
4 Slot 6 Output module
5 Slot 5 Output module
6 Slot 4 Output module
7 Slot 3 Output module
8 Slot 2 Output module
9 Slot 1 Output module
10 Parallel code
11 Series and option code *7
Refer to instruction manual
8 7 6 5 4 3 2 1
Slot
* The number of slot is
different depending on
the model.
SPECIFICATIONS
INPUT
OUTPUT
FUNCTION
ISOLATION
MAX
ENVIRONMENT
SAFTY AND
NOISE
REGULATIONS
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
AC100V *1
CURRENT[A]
AC200V *2
AC100V *1
POWER FACTOR
AC200V *2
INRUSH CURRENT AC100V
[A]
AC200V
AC100V *1
EFFICIENCY[%]
AC200V *2
LEAKAGE CURRENT [mA] *3
*4
NUMBER OF SLOT
TOTAL MAXIMUM AC90 - 150V *5
POWER[W]
AC170 - 264V *5
START-UP TIME AC100V *1
[ms]
AC200V *2
HOLD-UP TIME[ms] *1
ALARM
INPUT-OUTPUT, RC
INPUT-FG
OUTPUT, RC-FG
OPERATING TEMP.,HUMID. AND ALTITUDE *5
STORAGE TEMP.,HUMID. AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE
OTHERS
WEIGHT
COOLING METHOD
*6
MAX1600F (M1F)
MAX1600T (M1T)
MAX3200T (M3T)
AC170 - 264 3f
AC170 - 264 3f
AC85 - 264 1f / DC120 - 350
47 - 63
47 - 63
47 - 63
19typ
10typ
6.5typ
13typ
0.99typ
0.95typ
0.95typ
0.95typ
20/40typ (Primary inrush current/Secondary inrush current) 40/40typ (Primary inrush current/Secondary inrush current) 40typ
40typ
78typ
82typ
85typ
85typ
1.5max
2max
2max
4
4
8
1500
1600
1600
3200
700typ
500typ
500typ
500typ
20typ
20typ
20typ
FAN ALARM
FAN AND OPEN PHASE ALARM FAN AND OPEN PHASE ALARM
AC3,000V 1minute, Cutoff current=25mA, DC500V 50MW min (At Room Temperature) (Cutoff current = 100mA : MAX3200T)
AC2,000V 1minute, Cutoff current=25mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current=100mA, DC500V 50MW min (At Room Temperature)
-20 to +65C, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
19.6m/s 2 , 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s 2 , 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, Complies with DEN-AN (At only AC input)
Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B Complies with FCC-A, VCCI-A, CISPR22-A and EN55011-A
Complies with IEC61000-3-2 *8
200X97X300mm (WXHXD)
340X97X300mm (WXHXD)
200X97X300mm (WXHXD)
[7.87X3.82X11.81 inches]
[7.87X3.82X11.81 inches]
[13.39X3.82X11.81 inches]
7kg max
Forced cooling (built-in)
7kg max
*1 It is a value when M1F-HFEC-00 (MAX1600F : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1500W.
The value changes by composing the output modules.
*2 It is a value when M1F-HFEC-00 (MAX1600F : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1600W or
M1T-HFEC-00 (MAX1600T : 5V80A, 12V34A, 15V27A, 24V17A) outputs 1600W or
M3T-HHFFEECC-00 (MAX3200T : 5V80AX2, 12V34AX2, 15V27AX2, 24V17AX2) outputs 3200W.
The value changes by composing the output modules.
14kg max
*3
*4
*5
*6
*7
*8
Complies with IEC60950 at AC240V 60Hz.
Each output module is insulated.
Refer to derating.
Case size contains neither the terminal blocks (cover) nor the screw.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
MAX-2
MAX_E.indd 2
15.6.18 5:57:51 PM
MAX series
Output module specifications
CODE
ITEM
Number of slots used
VOLTAGE[V]
CURRENT[A]
LINE REGURATION[mV]max
LOAD REGURATION[mV]max
0 to +50C*1
RIPPLE
[mV]max
-20 to 0C*1
0 to +50C*1
RIPPLE NOISE
[mV]max
-20 to 0C*1
0 to +50C
TEMPRATURE
COEFFICIENT[mV]max -10 to +50C
*2
DRIFT[mV]max
OUTPUT VOLTAGE SETTING[V]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OUTPUT
CURRENT IN
PARALLEL[A]
TWO MODULES
IN PARALLEL
THREE MODULES
IN PARALLEL
FOUR MODULES
IN PARALLEL
FIVE MODULES
IN PARALLEL
SIX MODULES
IN PARALLEL
SEVEN MODULES
IN PARALLEL
EIGHT MODULES
IN PARALLEL
*3
F
E
D
C
B
A
1
1
1
1
1
1
15
12
7.5
5
3.3
2
27
34
54
80
80
80
60
48
30
20
20
20
120
100
60
40
40
40
120
120
120
80
80
80
160
160
160
140
140
140
150
150
150
120
120
120
180
180
180
160
160
160
150
120
75
50
40
40
225
180
120
75
60
60
60
48
30
20
12
12
2.00 - 2.06 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60
1.98 - 2.20 2.64 - 3.63 4.00 - 5.50 6.00 - 8.25 9.60 - 13.20 12.00 - 16.50
Works over 105% of rated current automatic recovery
4.00 - 5.50 4.00 - 5.50 5.75 - 7.00 8.63 - 10.50 13.80 - 16.80 17.25 - 21.00
G
1
18
22
72
150
120
160
150
180
180
270
72
18.00 - 18.72
14.40 - 19.80
144
216
300
360
444
516
600
40
60
80
100
120
140
160
144
216
300
360
444
516
600
144
216
300
360
444
516
600
97
146
195
243
292
341
390
61
92
125
153
196
217
250
49
73
100
122
149
173
200
H
1
24
17
96
150
120
160
150
180
240
360
96
24.00 - 24.96
19.20 - 26.40
I
1
28
14.5
112
180
120
160
150
180
280
420
112
28.00 - 29.12
22.40 - 30.80
O
1
BLANK
PANEL
MAX
20.70 - 25.20 27.60 - 33.60 32.20 - 39.20
31
46
63
77
92
107
127
26
40
54
66
80
94
108
-
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN : RM101).
Ripple and Ripple Noise is measured by using measuring board with capacitor of 470mF between 20mm to 100mm from the output terminal.
*2 Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Modulars in parallel are built to order and are not possible for the user to assemble them.
Block diagram
MAX1600F
VARIOUS
SIGNALS
FUSE
INPUT
VOLTAGE
AC85 - 264V
(1f)
AC250V
50A
REMOTE
ON/OFF
NOISE
FILTER
INRUSH
CURRENT
LIMITING
ACTIVE
FILTER
RECTIFIER
AND
FILTER
OUTPUT
MODULE
2-4SLOTS
DC
OUTPUT
FG
INTERNAL
REGURATOR
FAN
ALARM
MAX1600T / MAX3200T
FUSE
AC250V 15A (MAX1600T)
AC250V 30A (MAX3200T)
INPUT
VOLTAGE
AC170 - 264V
(3f)
MAX
VARIOUS
SIGNALS
NOISE
FILTER
RECTIFIER
INRUSH
CURRENT
LIMITING
FILTER
OUTPUT
MODULE
2-4SLOTS
(MAX1600T)
4-8SLOTS
(MAX3200T)
REMOTE
ON/OFF
DC
OUTPUT
FG
OPEN PHASE
INTERNAL
REGURATOR
FAN
ALARM
MAX-3
MAX-3
MAX_E.indd 3
15.6.18 5:57:52 PM
MAX series
MAX1600F / MAX1600T external view
AC (L1)
input
(15) 9.5 16 16
13
[0.59] [0.37] [0.63] [0.63]
[0.51]
27max
Name plate
[1.06]
M5
Output
terminal (-)
input
M5
AC (L)
20
AC (L2)
FG
FG
AC (L3)
8-M4
Mounting Hole
(Both sides)
slot2
9 14 17 14
[0.37]
[0.35] [0.55] [0.67] [0.55]
(76)
[2.99]
[1.42]
36
[1.42]
CN1
(9.5)
[0.98]
slot1
(24.8)
M5
160t0.5
[6.3] 200
slot3
[1.42]
Output
terminal (+)
(182)
36 [7.17] 36
slot4
MAX1600T
241t0.5
[9.49] 300
25
max
Output voltage
[0.98]
adjustable potentiometer (VR1)
[7.87]
13
[0.51]
[0.79]
AC (N)
(15) 9.5 16 16
[0.59] [0.37] [0.63] [0.63]
35
[1.38]
[11.81]
MAX1600F
Input terminal cover
67t0.5
Mounting Hole
(Both sides)
[2.64] 97
[3.82]
Tolerance : t1 [t0.04]
Weight : 7kg max
PCB Material/thickness : FR-4/1.6mm [0.06]
Chassis material : Stainless steel SUS430
Dimensions in mm, [ ]= inches
241t0.5
Mounting torque : 1.5N-m (16kgf-cm) max
[9.49]
Keep drawing current per terminal bellow 80A of output terminal.
The housing for the remote sensing unused is mounted on CN1 of each output module.
However, when the output module is connected in parallel, the housing is mounted on only master output module.
¶ Output terminal covers are appended.
15
8-M4
¶
¶
¶
¶
¶
¶
¶
¶
[0.59]
MAX
AIR FLOW
35
[1.38]
MAX3200T external view
AC(L3)
13
[0.37]
[0.51]
[0.59]
16 16
[0.63] [0.63]
input
AC(L2)
AC(L1)
27max
Name plate
[1.06]
M5
Output terminal(–)
150 t0.5
36
[1.42]
36
Output terminal(+)
[1.42]
slot8
12-M4
Mounting Hole
(Both sides)
slot7
[5.91]
FG
(15) 9.5
[13.39]
340
36
[1.42]
[12.68]
36
slot5
[1.42]
(322)
slot6
150 t0.5
[5.91]
[1.38]
300
[11.81]
[0.98]
Tolerance : t1 [t0.04]
Weight : 14kg max
PCB Material/thickness : FR-4/1.6mm [0.06]
Chassis material : Stainless steel SUS430
241t0.5
Dimensions in mm, [ ]= inches
[9.49]
Mounting torque : 1.5N-m (16kgf-cm) max
Keep drawing current per terminal bellow 80A of output terminal.
The housing for the remote sensing unused is mounted on CN1 of each output module.
However, when the output module is connected in parallel, the housing is mounted on only master output module.
¶ Output terminal covers are appended.
97
8-M4
Mounting Hole
(Both sides)
[3.82]
adjustable potentiometer(VR1)
67t0.5
¶
¶
¶
¶
¶
¶
¶
¶
[9.49]
25max
(76)
[2.99]
35
241t0.5
Output voltage
adjustable potentiometer(VR1)
[2.64]
[0.35] [0.55] [0.67] [0.55]
[0.59]
[0.37]
15
9 14 17 14
20
CN1
(9.5)
[1.42]
36
slot1
MAX
(24.8) 36
M5
[0.98]
slot2
[1.42]
slot3
[0.79]
36
[1.42]
slot4
AIR FLOW
35
[1.38]
MAX-4
MAX_E.indd 4
15.6.18 5:57:52 PM
MAX series
Function connector (CN1) pinassign
CN1
1
3
5
7
9
2
4
6
8
10 12
11
Maiting connector and terminal of output module CN1
Connector Mating connector
CN1
Terminal
Mfr.
Chain : SPHD-002T-P0.5
S12B-PHDSS PHDR-12VS Loose : BPHD-001T-P0.5
J.S.T
: BPHD-002T-P0.5*1
*1 Ratchet Hand is nothing
Pin connection and function of output module CN1
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
+M
-M
+S
-S
TRM
-S
RC2
-S
RC3
ALM
IOG
TMP
Function
: +Output voltage monitoring
: -Output voltage monitoring
: +Remote sensing
: -Remote sensing, Signal ground
: Adjustment of output Voltage
: -Remote sensing, Signal ground
: Remote ON/OFF
: -Remote sensing, Signal ground
: Remote ON/OFF
: Fan alarm (and open phase alarm)*
: Inverter operation monitor
: Thermal detection signal
MAX
*MAX1600T / MAX3200T
MAX
MAX-5
MAX-5
MAX_E.indd 5