POST FRAME LIGHT GAUGE APPLICATION GUIDE Lebanon, PA • 888.339.0059 Bridgton, ME • 888.339.0059 Howe, IN • 866.562.3782 www.everlastroofing.com Post Frame Frame Light Light Gauge Guage Post Table of Contents Post Frame Trim Light Gauge Trim LG 02 - LG 03 Application Guidelines Safety and Minimum Slope Handling and Storage Installation / Ventilation / Cutting Coverage / Overlap/Screw / Nail Patterns LG 04 LG 05 LG 06 LG 07 - LG 08 Post Frame Details Post Frame Ridge and Hip Post Frame Rake & Corner Post Frame Base Angle Post Frame Fascia Post Frame Gable Post Frame J Channel Post Frame Double Angle Post Frame Sidewall Post Frame Drip Cap Post Frame Post Trim Post Frame Endwall Post Frame F & J Trim Post Frame Inside Corner Post Frame Overhead Door Post Frame Track Cover Post Frame Drip Edge Post Frame Fascia & Soffit Post Frame Formed Valley Post Frame Notched Endwall All information is LG 09 LG 10 LG 11 LG 12 LG 13 LG 14 LG 15 LG 16 LG 17 LG 18 LG 19 LG 20 LG 21 LG 22 LG 23 LG 24 LG 25 LG 26 LG 27 © copyright Everlast Roofing, Inc. 2010 Post Frame Frame Light Light Gauge Guage Post A C L P G M E K O H N B I J F D Coverage/Overlap and Screw/Nail Pattern of Everlast II™ Everlast II™ Post Frame Trim TLURC1xx Purpose: F 29 Ga. Rake & Corner B 29 Ga. Gable Trim 29 Ga. AG4 Gable Trim C 10’2” 10’2” TLGT5xx F 7/8˝ D TLFS17xx 29 Ga. Base Angle 10’2” TLBA3xx F 1˝ F 4 1/8˝ 1/ 4 1/2˝ 2˝ 1˝ 4˝ 4˝ C 10’ 12’ 14’ 16’ TLRC2xxxx C 5 1/ ˝ 2 10’6” 1 3/4˝ 29 Ga. 13” Univ. Ridge 4 1/2˝ A 7/8˝ 1˝ 2˝ 1/ 29 Drip Edge “F”Ga. 6.5” Trim 3˝ F 10’2” TL6.5F60xx F I F 29 Ga. “J” Channel 10’2” TLJC6xx G P 1˝ All information is I 29 Ga. Drip Cap 10’2” TLDC9xx J 29 Ga. Post Trim © copyright K F 1 1 2˝ / 7/8˝ 7/8˝ F 29 Ga. Univ. Sidewall 10’2” TLUS8xx 1˝ 1 2˝ ˝ 1/ 2 3/8˝ 3/4˝ 4 1/2˝ 3/4˝ H 10’2” TLDA7xx 4˝ LG-02 29 Ga. Double Angle F 2 5/8˝ E 1 3 4˝ / 29 Ga. Fascia Trim 10’2” TLFT4xx 3 1/2˝ 1˝ Everlast Roofing, Inc. 2010 29 Ga. Notched Endwall EL K 29 Ga. Univ. Endwall L 29 Ga. “F” & “J” 7/8˝ 1˝ E 11 /2 ˝ 5/8˝ 4 1/8˝ This application guide is intended to assist in the application of light gauge Everlast Roofing products on 1 3/ 4˝ 4˝ 1 3/ 1˝ 4 1/2˝ post frame structures. The details and illustrations in this manual may not be applicable to all building plans F or field situations. It is the buyer's responsibility to verify all applicable code requirements, check all field measurements, and determine suitability of the material for the job. A C L P G M E K O H N B I J F D Post Frame Trim Coverage/Overlap and Screw/Nail Pattern of Everlast II™ Everlast II™ Post Frame Trim B C F 29 Ga. Rake & Corner C 10’ 12’ 14’ 16’ TLRC2xxxx 29 Ga. Gable Trim C F 7/8˝ 29 Ga. AG4 Gable Trim 1˝ F 2˝ 1/ 4 1/2˝ 5 1/ ˝ 2 1 3/ 4˝ 1˝ 3˝ 29 Drip Edge “F”Ga. 6.5” Trim F 10’2” TL6.5F60xx I F F 29 Ga. “J” Channel G 10’2” TLJC6xx 29 Ga. Double Angle P F 1 1 2˝ / 1 2˝ F 7/8˝ F 3 1/2˝ 1˝ 1˝ 7/8˝ 29 Ga. Univ. Sidewall 10’2” TLUS8xx 1˝ ˝ 1/ 2 3/8˝ 4 1/2˝ 3/4˝ 4˝ 3/4˝ H 10’2” TLDA7xx 2 5/8˝ E 2˝ 1/ 1˝ 1 3 4˝ / 29 Ga. Fascia Trim 10’2” TLFT4xx 11 /2 4 1/2˝ F E 1˝ ˝ 4˝ 5/8˝ 7/8˝ 4 1/8˝ 1 3/ 10’2” TLBA3xx 4 1/8˝ 1˝ 4˝ 29 Ga. Base Angle F 4 1/2˝ 4˝ D 10’2” TLFS17xx 10’2” TLGT5xx 7/8˝ 10’6” TLURC1xx 1 3/4˝ 29 Ga. 13” Univ. Ridge A J 10’2” TLDC9xx P 29 Ga. Post Trim K 29 Ga. Notched Endwall EL K 42” TLNEEL32xx 10’2” TLPT10xxxx 29 Ga. Univ. Endwall F F 1˝ 2 3/8˝ 1 1/2˝ Notched to fit panel profile F 4 8 7/ F 1˝ 9/16˝ ˝ 1˝ 5˝ 7 1/2˝ 7 3/4˝ 9 3/4˝ 11˝ 29 Ga. “F” & “J” 10’2” TLFJ12xx F 6˝ 3 1/2˝ 5 1/2˝ 6˝ 7 1/4˝ L 10’2” TLUE11xx 6˝ 1˝ 7/8˝ 2 3/8˝ 29 Ga. Drip Cap I ˝ 29 Ga. 11.25” Fascia & Soffit M 29 Ga. Inside Corner 10’2” TLIC13xx N P 29 Ga. Overhead Door 10’2” 12’6” TLODT14xx O 29 Ga. Track Cover Cannonball FM 10’2” TLCT15xx 4 1/2˝ 1˝ F Jan. 07 All information is © copyright 7 8˝ / 9˝ 4 1/2˝ 4 3/4˝ 8˝ 5/ 1˝ F 1 3/4˝ 7˝ 4 3/4˝ F 1˝ 2˝ 5 1/2˝ 11 1/4˝ 1 3/4˝ 7/8˝ 10’2” TLFS17xx /1 ˝3 8 L 1 1/2˝ 1˝ Everlast Roofing, Inc. 2010 F 8˝ 5/ LG-03 Post Frame Light Gauge Guage Application Guidelines Safety: Always work safely when installing metal products. Use extreme caution on a roof at all times, and wear gloves and safety glasses to avoid injury. Hearing protection should be used when power-cutting metal panels. Do not walk on panels until all fasteners are installed. Metal panels are slippery when wet, dusty, frosty or oily. Do not attempt to walk on a metal roof under these conditions. Always use OSHA recommended safety harness or equipment when working on a roof. Wear soft-soled shoes to improve traction and to minimize damage to the paint finish. Always be aware of your position on the roof relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels on a windy day can be dangerous and should be avoided. Consult OSHA guidelines for more comprehensive safety requirements. Minimum Slope: Everlast Roofing light gauge products are designed to be installed on pitches of no less than 3:12. Please contact an Everlast sales representative for product recommendations on lower sloped roofs. ALLOWABLE UNIFORM LIVE LOADS IN POUNDS PER SQUARE FOOT Live Load based on L/180 deflection Span (Feet) 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 29 Gauge (.015) 156 79 46 - - 207 105 61 - - 1. 2. 3. 4. 5. LG-04 Wind Load (Stress) Maximum allowable loads are based upon a continuous three span sheet application. Calculated in accordace with the 1996 AISI Cold Formed Steel Design Manual. Maximum allowable loads for wind have been increased by 33%. Allowable deflection loads are limited by a maximum deflection ratio of L/180 of span. Everlast Roffing, Inc. reserves the right to change the specifications of its products without notice. All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Light Guage Gauge Handling: A. Do not lift panels from ends while flat. Lift the panels on edge when moving individual panels or when moving panels onto the roof. B. Do not unload in a jerking or bouncing fashion. While unloading, the bundle must be handled at lift point, specified by Everlast Roofing, Inc. Panels greater than 25' long should be unloaded using spreader bar to prevent panels from bending. C. Although the paint coating is tough, dragging panels across the surface of one another will almost certainly damage the finish. Improper handling of metal panels may cause scratches to the paint finish. ELR offers matching touch up paint in a variety of standard colors in the event of any scratches to the paint finish. Please note: touch up paint will not weather as well or at the same rate as the original coating or finish. Storage: A. If the material is not to be used immediately, it should be stored in a dry place. Moisture trapped between sheets may cause damage to the paint system. The paint system may become soft or water stains may appear which can detract from the appearance and affect the service life of the material. To avoid problems store the materials in a well-ventilated dry area. Stack the materials in an incline position. DO NOT USE PLASTIC TO COVER MATERIALS. THIS CAN CAUSE SWEATING OR CONDENSATION! All information is © copyright Everlast Roofing, Inc. 2010 LG-05 Post Frame Light Gauge Guage Installation Recommendations: - - - - - Panels can be installed over open purlins. See load chart for spacing Panels should be installed against any prevailing wind Panels should be installed square, plumb and properly aligned to one another Galvanized and galvalume panels should remain void of any condensation containing copper, lead or uncoated steel materials In situations where an endlap of a panel is required, be certain to overlap upper panel a minimum of 8” over lower panel and apply sealant and butyl lap tape uniformly between the two panels. Ventilation/Insulation: Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. Condensation occurs when moistureladen air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique to metal buildings; these problems are common to all types of construction. In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on cold surfaces, either inside the building or within the wall/roof/system cavity. The arrangement of the building’s insulation system and vapor retarder is the responsibility of the building designer. These are some basic guides to help control condensation. A. B. C. D. The insulation should have a vapor retarder face on the “warm” side of the insulation. For most buildings, this means that the vapor retarder is on the inside surface (toward the building’s interior). The thickness of the insulation must be designed to maintain temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature. All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor. Building ventilation, whether by gravity ridge vent, power-operated fans, or other means, contributes significantly to reduced condensation. The movement of air to the outside of the building reduces the interior level of vapor pressure. On the buildings that have an attic space or are being retrofitted with metal roofing systems, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Contact your local building code official or an engineer on proper ventilation practices for you area. Cutting: Everlast recommends the use of tin snips or a "nibbler" type electric tool to field cutting metal panels. Cutting metal panels may create metal shavings. A. B. These shavings and/or chips must be removed immediately from the panel surface. Failure to remove such shavings or chips may cause staining and/or rust on the panel.. Any such surface damage will void the warranty. For your protection goggles should be worn when cutting metal panels and flashing. * This same principle applies when driving steel fasteners (see pages LG07 & LG08) LG-06 All information is © copyright Everlast Roofing, Inc. 2010 Coverage/Overlap and Screw/Nail Pattern of Everlast II™ CO OV L ER R VE AG E AP Siphon Groove Woodscrew Roof Structure SCREW PATTERN NAIL PATTERN *Note - minimum of 1" fastener penetration is recommended All information is © copyright Everlast Roofing, Inc. 2010 LG-07 Coverage/Overlap and Screw/Nail Pattern of Everdrain™ CO OV L ER V A ER GE AP Siphon Groove Wood Screw Roof Structure SCREW PATTERN LG-08 All information is NAIL PATTERN © copyright Everlast Roofing, Inc. 2010 Post Frame Vented Universal Ridge Ridge Ridge Vent Ridge Cap Fastener Panel Vapor Barrier Profile 01 Universal Ridge TLURC1xx All information is © copyright Everlast Roofing, Inc. 2010 LG-09 Post Frame Rake & Corner Panel Post Caulk Fastener Girt Caulk Fastener Profile 02 Rake & Corner TLRC2xxxx LG-10 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Base Angle Panel Inside Closure Skirt Board Fastener Caulk 1˝ Profile 03 Base Angle TLBA3xx All information is © copyright Everlast Roofing, Inc. 2010 LG-11 Post Frame Fascia Trim Roof Fastener Inside Closure Caulk Panel Caulk Purlin Caulk Fastener Caulk Roof Truss Outside Closure Post Panel Top Plate Fastener Profile 04 Fascia Trim TLFT4xx LG-12 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Gable Trim Panel Caulk Purlin Caulk End Rafter Outside Closure Panel Profile 05 Gable Trim TLGT5xx All information is © copyright Everlast Roofing, Inc. 2010 LG-13 Post Frame “J” Channel Door Jamb Door Girt Door Stop Caulk 'J' Channel Panel Fastener Profile 06 “J” Channel TLJC6xx LG-14 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Double Angle Panel Girt Caulk Fastener Inside Closure Fastener Butyl Tape Caulk Outside Closure Panel Profile 07 Double Angle TLDA7xx All information is © copyright Everlast Roofing, Inc. 2010 LG-15 Post Frame Universal Sidewall Panel Inside Closure Girt Fastener Panel Butyl Tape Caulk Fastener Purlin Sloping Rafter Profile 08 Universal Sidewall TLUS8xx LG-16 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Drip Cap Panel Caulk Fastener Inside Closure Window Unit Profile 09 Drip Cap TLDC9xx All information is © copyright Everlast Roofing, Inc. 2010 LG-17 Post Frame Post Trim Door Jamb Door Girt Fastener Door Stop Caulk 'J' Channel Fastener Panel Profile 10 Post Trim TLPT10xxxx LG-18 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Universal Endwall Panel Inside Closure Girt Fastener Butyl Tape Fastener Butyl Tape Outside Closure Purlin Profile 11 Universal Endwall TLUE11xx All information is © copyright Everlast Roofing, Inc. 2010 LG-19 Post Frame “F” & “J” Trim Panel Fastener Caulk Inside Closure Facia Board Post Trim Soffit Wall Structure Fastener Panel Profile 12 “F” & “J” Trim TLFJ12xx LG-20 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Inside Corner Girt Caulk Fastener Post Fastener Girt Caulk Profile 13 Inside Corner TLIC13xx All information is © copyright Everlast Roofing, Inc. 2010 LG-21 Post Frame Overhead Door Panel Door Header Door Stops Man Door Overhead Door Profile 14 Overhead Door TLODT14xx LG-22 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Track Cover Cannonball FM Panel Caulk Fastener Girt 15 Track Cover Cannonball FM Profile TLCT15xx All information is © copyright Everlast Roofing, Inc. 2010 LG-23 Post Frame Drip Edge EL Panel Fastener Inside Closure Drip Edge Butyl Tape Facia Board Caulk Post Trim Soffit Profile 60 Drip Edge TL6.5F60xx LG-24 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Fascia & Soffit Panel Fastener Butyl Tape Inside Closure Fastener Facia Board Girt Fastener Soffit Panel Profile 17 Fascia & Soffit TLFS17xx All information is © copyright Everlast Roofing, Inc. 2010 LG-25 Post Frame Formed Valley Valley Closure Panel Vapor Barrier Solid Roof Structure Formed Valley Profile 19 Formed Valley TLFV19xx LG-26 All information is © copyright Everlast Roofing, Inc. 2010 Post Frame Notched Endwall EL Panel Caulk Fastener Inside Closure Notched to fit panel profile Girt Butyl Tape Top & Bottom of Closure Outside Closure Purlin Profile 32 Notched Endwall EL TLNEEL32xx All information is © copyright Everlast Roofing, Inc. 2010 LG-27 Notes 10 Enterprise Court Lebanon, PA 17042 Office: 888-339-0059 Fax: 717-270-6569 P.O. Box 278, 81 South High St. 7180 N 050 E Bridgton, ME 04009-0278 Howe, IN 46746 Office: 888-339-0059 Office: 866-562-3782 Fax: 207-647-5599 Fax: 260-562-3738 All information is © copyright Everlast Roofing, Inc. 2010
© Copyright 2025 Paperzz