POST FRAME LIGHT GAUGE APPLICATION GUIDE

POST FRAME
LIGHT GAUGE
APPLICATION GUIDE
Lebanon, PA • 888.339.0059
Bridgton, ME • 888.339.0059
Howe, IN • 866.562.3782
www.everlastroofing.com
Post Frame
Frame Light
Light Gauge
Guage
Post
Table of Contents
Post Frame Trim
Light Gauge Trim
LG 02 - LG 03
Application Guidelines
Safety and Minimum Slope
Handling and Storage
Installation / Ventilation / Cutting
Coverage / Overlap/Screw / Nail Patterns
LG 04
LG 05
LG 06
LG 07 - LG 08
Post Frame Details
Post Frame Ridge and Hip
Post Frame Rake & Corner
Post Frame Base Angle
Post Frame Fascia
Post Frame Gable
Post Frame J Channel
Post Frame Double Angle
Post Frame Sidewall
Post Frame Drip Cap
Post Frame Post Trim
Post Frame Endwall
Post Frame F & J Trim
Post Frame Inside Corner
Post Frame Overhead Door
Post Frame Track Cover
Post Frame Drip Edge
Post Frame Fascia & Soffit
Post Frame Formed Valley
Post Frame Notched Endwall
All information is
LG 09
LG 10
LG 11
LG 12
LG 13
LG 14
LG 15
LG 16
LG 17
LG 18
LG 19
LG 20
LG 21
LG 22
LG 23
LG 24
LG 25
LG 26
LG 27
© copyright
Everlast Roofing, Inc. 2010
Post Frame
Frame Light
Light Gauge
Guage
Post
A
C
L
P
G
M
E
K
O
H
N
B
I
J
F
D
Coverage/Overlap
and Screw/Nail
Pattern of Everlast II™
Everlast
II™ Post Frame
Trim
TLURC1xx
Purpose:
F
29 Ga. Rake & Corner
B
29 Ga. Gable Trim
29 Ga. AG4 Gable Trim
C
10’2”
10’2” TLGT5xx
F
7/8˝
D
TLFS17xx
29 Ga. Base Angle
10’2” TLBA3xx
F
1˝
F
4 1/8˝
1/
4 1/2˝
2˝
1˝
4˝
4˝
C
10’ 12’ 14’ 16’ TLRC2xxxx
C
5 1/ ˝ 2
10’6”
1 3/4˝
29 Ga. 13” Univ. Ridge
4 1/2˝
A
7/8˝
1˝
2˝
1/
29
Drip
Edge
“F”Ga.
6.5”
Trim
3˝
F
10’2” TL6.5F60xx
F
I
F
29 Ga. “J” Channel
10’2” TLJC6xx
G
P
1˝
All information is
I
29 Ga. Drip Cap
10’2” TLDC9xx
J
29 Ga. Post Trim
© copyright
K
F
1 1 2˝ /
7/8˝
7/8˝
F
29 Ga. Univ. Sidewall
10’2” TLUS8xx
1˝
1
2˝
˝
1/
2 3/8˝
3/4˝
4 1/2˝
3/4˝
H
10’2” TLDA7xx
4˝
LG-02
29 Ga. Double Angle
F
2 5/8˝
E
1 3 4˝ /
29 Ga. Fascia Trim
10’2” TLFT4xx
3 1/2˝
1˝
Everlast Roofing, Inc. 2010
29 Ga. Notched Endwall EL
K
29 Ga. Univ. Endwall
L
29 Ga. “F” & “J”
7/8˝
1˝
E
11
/2
˝
5/8˝
4 1/8˝
This
application guide
is intended to assist in the application of light gauge Everlast Roofing products on
1 3/
4˝
4˝
1 3/
1˝
4 1/2˝
post frame structures. The details and
illustrations in this manual may not be applicable to all building plans
F
or field situations. It is the buyer's responsibility to verify all applicable code requirements, check all field
measurements, and determine suitability of the material for the job.
A
C
L
P
G
M
E
K
O
H
N
B
I
J
F
D
Post Frame Trim
Coverage/Overlap
and Screw/Nail
Pattern of Everlast II™
Everlast
II™ Post Frame
Trim
B
C
F
29 Ga. Rake & Corner
C
10’ 12’ 14’ 16’ TLRC2xxxx
29 Ga. Gable Trim
C
F
7/8˝
29 Ga. AG4 Gable Trim
1˝
F
2˝
1/
4 1/2˝
5 1/ ˝ 2
1 3/
4˝
1˝
3˝
29
Drip
Edge
“F”Ga.
6.5”
Trim
F
10’2” TL6.5F60xx
I
F
F
29 Ga. “J” Channel
G
10’2” TLJC6xx
29 Ga. Double Angle
P
F
1 1 2˝ /
1
2˝
F
7/8˝
F
3 1/2˝
1˝
1˝
7/8˝
29 Ga. Univ. Sidewall
10’2” TLUS8xx
1˝
˝
1/
2 3/8˝
4 1/2˝
3/4˝
4˝
3/4˝
H
10’2” TLDA7xx
2 5/8˝
E
2˝
1/
1˝
1 3 4˝ /
29 Ga. Fascia Trim
10’2” TLFT4xx
11
/2
4 1/2˝
F
E
1˝
˝
4˝ 5/8˝
7/8˝
4 1/8˝
1 3/
10’2” TLBA3xx
4 1/8˝
1˝
4˝
29 Ga. Base Angle
F
4 1/2˝
4˝
D
10’2” TLFS17xx
10’2” TLGT5xx
7/8˝
10’6” TLURC1xx
1 3/4˝
29 Ga. 13” Univ. Ridge
A
J
10’2” TLDC9xx
P
29 Ga. Post Trim
K
29 Ga. Notched Endwall EL
K
42” TLNEEL32xx
10’2” TLPT10xxxx
29 Ga. Univ. Endwall
F
F
1˝
2 3/8˝
1 1/2˝
Notched to fit panel profile
F
4
8
7/
F
1˝
9/16˝
˝
1˝
5˝
7 1/2˝
7 3/4˝
9 3/4˝
11˝
29 Ga. “F” & “J”
10’2” TLFJ12xx
F
6˝
3 1/2˝
5 1/2˝
6˝
7 1/4˝
L
10’2” TLUE11xx
6˝
1˝
7/8˝
2 3/8˝
29 Ga. Drip Cap
I
˝
29 Ga. 11.25” Fascia & Soffit
M
29 Ga. Inside Corner
10’2” TLIC13xx
N
P
29 Ga. Overhead Door
10’2” 12’6” TLODT14xx
O
29 Ga. Track Cover Cannonball FM
10’2” TLCT15xx
4 1/2˝
1˝
F
Jan. 07
All information is
© copyright
7 8˝ /
9˝
4 1/2˝
4 3/4˝
8˝
5/ 1˝
F
1 3/4˝
7˝
4 3/4˝
F
1˝
2˝
5 1/2˝
11 1/4˝
1 3/4˝
7/8˝
10’2” TLFS17xx
/1 ˝3 8
L
1 1/2˝
1˝
Everlast Roofing, Inc. 2010
F
8˝
5/
LG-03
Post Frame Light Gauge
Guage
Application Guidelines
Safety:
Always work safely when installing metal products. Use extreme caution on a roof at all times, and wear
gloves and safety glasses to avoid injury. Hearing protection should be used when power-cutting metal
panels. Do not walk on panels until all fasteners are installed. Metal panels are slippery when wet,
dusty, frosty or oily. Do not attempt to walk on a metal roof under these conditions. Always use OSHA
recommended safety harness or equipment when working on a roof. Wear soft-soled shoes to improve
traction and to minimize damage to the paint finish. Always be aware of your position on the roof
relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels on a
windy day can be dangerous and should be avoided. Consult OSHA guidelines for more comprehensive
safety requirements.
Minimum Slope:
Everlast Roofing light gauge products are designed to be installed on pitches of no less than 3:12.
Please contact an Everlast sales representative for product recommendations on lower sloped roofs.
ALLOWABLE UNIFORM LIVE LOADS IN POUNDS PER SQUARE FOOT
Live Load based on L/180 deflection
Span (Feet)
2ʹ0ʺ
2ʹ6ʺ
3ʹ0ʺ
3ʹ6ʺ
4ʹ0ʺ
2ʹ0ʺ
2ʹ6ʺ
3ʹ0ʺ
3ʹ6ʺ
4ʹ0ʺ
29 Gauge (.015)
156
79
46
-
-
207
105
61
-
-
1.
2.
3.
4.
5.
LG-04
Wind Load (Stress)
Maximum allowable loads are based upon a continuous three span sheet application.
Calculated in accordace with the 1996 AISI Cold Formed Steel Design Manual.
Maximum allowable loads for wind have been increased by 33%.
Allowable deflection loads are limited by a maximum deflection ratio of L/180 of span.
Everlast Roffing, Inc. reserves the right to change the specifications of its products without notice.
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Light Guage
Gauge
Handling:
A.
Do not lift panels from ends while flat. Lift the panels on edge when moving individual panels or when moving panels onto the roof.
B.
Do not unload in a jerking or bouncing fashion. While unloading, the bundle must be handled at lift point, specified by Everlast Roofing, Inc. Panels greater than 25' long should be unloaded using spreader bar to prevent panels from bending.
C.
Although the paint coating is tough, dragging panels across the surface of one another will almost certainly damage the finish. Improper handling of metal panels may cause scratches to the paint finish. ELR offers
matching touch up paint in a variety of standard colors in the event of any scratches to the paint finish.
Please note: touch up paint will not weather as well or at the same rate as the original coating or finish.
Storage:
A.
If the material is not to be used immediately, it should be stored in a dry place. Moisture trapped between
sheets may cause damage to the paint system. The paint system may become soft or water stains may appear which can detract from the appearance and affect the service life of the material. To avoid problems store the materials in a well-ventilated dry area. Stack the materials in an incline position. DO NOT USE PLASTIC TO COVER MATERIALS. THIS CAN CAUSE SWEATING OR CONDENSATION!
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-05
Post Frame Light Gauge
Guage
Installation Recommendations:
-
-
-
-
-
Panels can be installed over open purlins. See load chart for spacing
Panels should be installed against any prevailing wind
Panels should be installed square, plumb and properly aligned to one another
Galvanized and galvalume panels should remain void of any condensation containing copper, lead or uncoated steel materials
In situations where an endlap of a panel is required, be certain to overlap upper panel a minimum of 8” over lower panel and apply sealant and butyl lap tape uniformly between the two panels.
Ventilation/Insulation:
Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and
the resulting problems of moisture damage and loss of insulation efficiency. Condensation occurs when moistureladen air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon
creates problems that are not unique to metal buildings; these problems are common to all types of construction.
In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on
cold surfaces, either inside the building or within the wall/roof/system cavity. The arrangement of the building’s
insulation system and vapor retarder is the responsibility of the building designer. These are some basic guides to
help control condensation.
A.
B.
C.
D.
The insulation should have a vapor retarder face on the “warm” side of the insulation. For most buildings, this means that the vapor retarder is on the inside surface (toward the building’s interior).
The thickness of the insulation must be designed to maintain temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature.
All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor.
Building ventilation, whether by gravity ridge vent, power-operated fans, or other means, contributes significantly to reduced condensation. The movement of air to the outside of the building reduces the
interior level of vapor pressure. On the buildings that have an attic space or are being retrofitted with
metal roofing systems, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Contact your local building code official or an engineer on proper ventilation practices for you area.
Cutting:
Everlast recommends the use of tin snips or a "nibbler" type electric tool to field cutting metal panels. Cutting
metal panels may create metal shavings.
A.
B.
These shavings and/or chips must be removed immediately from the panel surface. Failure to remove such shavings or chips may cause staining and/or rust on the panel.. Any such surface damage will void the warranty.
For your protection goggles should be worn when cutting metal panels and flashing.
* This same principle applies when driving steel fasteners (see pages LG07 & LG08)
LG-06
All information is
© copyright
Everlast Roofing, Inc. 2010
Coverage/Overlap and Screw/Nail Pattern of Everlast II™
CO
OV
L
ER
R
VE
AG
E
AP
Siphon Groove
Woodscrew
Roof Structure
SCREW PATTERN
NAIL PATTERN
*Note - minimum of 1" fastener
penetration is recommended
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-07
Coverage/Overlap and Screw/Nail Pattern of Everdrain™
CO
OV
L
ER
V
A
ER
GE
AP
Siphon Groove
Wood Screw
Roof Structure
SCREW PATTERN
LG-08
All information is
NAIL PATTERN
© copyright
Everlast Roofing, Inc. 2010
Post Frame Vented
Universal
Ridge
Ridge
Ridge Vent
Ridge Cap
Fastener
Panel
Vapor Barrier
Profile
01 Universal Ridge
TLURC1xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-09
Post Frame Rake & Corner
Panel
Post
Caulk
Fastener
Girt
Caulk
Fastener
Profile
02 Rake & Corner
TLRC2xxxx
LG-10
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Base Angle
Panel
Inside Closure
Skirt
Board
Fastener
Caulk
1˝
Profile
03 Base Angle
TLBA3xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-11
Post Frame Fascia Trim
Roof
Fastener
Inside
Closure
Caulk
Panel
Caulk
Purlin
Caulk
Fastener
Caulk
Roof
Truss
Outside Closure
Post
Panel
Top Plate
Fastener
Profile
04 Fascia Trim
TLFT4xx
LG-12
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Gable Trim
Panel
Caulk
Purlin
Caulk
End Rafter
Outside Closure
Panel
Profile
05 Gable Trim
TLGT5xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-13
Post Frame “J” Channel
Door Jamb
Door
Girt
Door Stop
Caulk
'J' Channel
Panel
Fastener
Profile
06 “J” Channel
TLJC6xx
LG-14
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Double Angle
Panel
Girt
Caulk
Fastener
Inside Closure
Fastener
Butyl Tape
Caulk
Outside Closure
Panel
Profile
07 Double Angle
TLDA7xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-15
Post Frame Universal Sidewall
Panel
Inside Closure
Girt
Fastener
Panel
Butyl Tape
Caulk
Fastener
Purlin
Sloping Rafter
Profile
08 Universal Sidewall
TLUS8xx
LG-16
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Drip Cap
Panel
Caulk
Fastener
Inside Closure
Window Unit
Profile
09 Drip Cap
TLDC9xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-17
Post Frame Post Trim
Door Jamb
Door
Girt
Fastener
Door Stop
Caulk
'J' Channel
Fastener
Panel
Profile
10 Post Trim
TLPT10xxxx
LG-18
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Universal Endwall
Panel
Inside Closure
Girt
Fastener
Butyl Tape
Fastener
Butyl Tape
Outside
Closure
Purlin
Profile
11 Universal Endwall
TLUE11xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-19
Post Frame “F” & “J” Trim
Panel
Fastener
Caulk
Inside
Closure
Facia Board
Post Trim
Soffit
Wall Structure
Fastener
Panel
Profile
12 “F” & “J” Trim
TLFJ12xx
LG-20
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Inside Corner
Girt
Caulk
Fastener
Post
Fastener
Girt
Caulk
Profile
13 Inside Corner
TLIC13xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-21
Post Frame Overhead Door
Panel
Door Header
Door Stops
Man Door
Overhead
Door
Profile
14 Overhead Door
TLODT14xx
LG-22
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Track Cover Cannonball FM
Panel
Caulk
Fastener
Girt
15 Track Cover Cannonball FM
Profile
TLCT15xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-23
Post Frame Drip Edge
EL Panel
Fastener
Inside Closure
Drip Edge
Butyl Tape
Facia Board
Caulk
Post Trim
Soffit
Profile
60 Drip Edge
TL6.5F60xx
LG-24
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Fascia & Soffit
Panel
Fastener
Butyl Tape
Inside Closure
Fastener
Facia Board
Girt
Fastener
Soffit
Panel
Profile
17 Fascia & Soffit
TLFS17xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-25
Post Frame Formed Valley
Valley Closure
Panel
Vapor Barrier
Solid Roof Structure
Formed Valley
Profile
19 Formed Valley
TLFV19xx
LG-26
All information is
© copyright
Everlast Roofing, Inc. 2010
Post Frame Notched Endwall EL
Panel
Caulk
Fastener
Inside Closure
Notched to fit
panel profile
Girt
Butyl Tape
Top & Bottom
of Closure
Outside
Closure
Purlin
Profile
32 Notched Endwall EL
TLNEEL32xx
All information is
© copyright
Everlast Roofing, Inc. 2010
LG-27
Notes
10 Enterprise Court
Lebanon, PA 17042
Office: 888-339-0059
Fax: 717-270-6569
P.O. Box 278, 81 South High St.
7180 N 050 E
Bridgton, ME 04009-0278
Howe, IN 46746
Office: 888-339-0059
Office: 866-562-3782
Fax: 207-647-5599
Fax: 260-562-3738
All information is
© copyright
Everlast Roofing, Inc. 2010