MEDIUM VOLTAGE DIN Fuse-Links MV DIN 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps Standards/Approvals: DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) Description: Catalogue Symbol: 36TDQSJ(amp) 36TFQSJ(amp) 3TXQEJ(amp) Class of Operation: Back-up as IEC 60282-1 (2005) Dimensional Data: Fuse Reference A C D Weight (Kg) 76 6.0 TDQSJ 537 54 51 TXQEJ 537 88 88 TFQSJ 537 80 SJ Outline 2.9 6.5 Packaging: All fuse-links are individually. MOQ: 3 Packaging 100% recyclable Technical Data: DIN fuse-links 17.5kV - 36kV Rated voltage: Amps: 3.15A to 63A Rated breaking capacity: 20kA to 35.5kA Rated frequency: 50Hz - 60Hz Suitable for outdoor and indoor use RoHS compliant EJ Outline Striker Diagram: S = Spring Striker 50N to DIN 43625 and IEC 60282-1 designation “medium” E = Spring Striker 80N to IEC 60282-1 designation “medium” Force x Travel diagram for 50N Din striker 60 Force x Travel diagram for 80N Din striker 100 90 50 80 70 Force (N) Force (N) 40 30 20 60 50 40 30 20 10 0 A range of medium voltage DIN Fuses, complete with sealed striker, suitable for transformer protection. The fuses can be used even where there is no secondary LV protection, provided they are used with fuse switches fitted with instantaneous striker tripping. 10 0 REV B - 10/4/2007 4 8 12 16 Travel (mm) 20 24 28 32 0 0 4 8 12 16 20 Travel (mm) 24 28 32 36 Form No. 36kV DIN Page 1 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links MV DIN 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps Table of Ratings Standard Approvals: Technical Data: Part Number 36TDQSJ3.15 36TDQSJ6.3 36TDQSJ10 36TDQSJ16 36TDQSJ20 36TDQSJ25 36TFQSJ31.5 36TFQSJ40 36TFQSJ50 36TXQEJ63* DIN 43625, VDE 0670 part 4, VDE 0670 part 402 and IEC 60282-1 (2005) 3.15, 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 Amps Breaking Capacity Current Rating In (A) I1 (kA) 3.15 Minimum Breaking Capacity I3 (A) 20 6.3 35.5 16 35.5 10 20 31.5 40 50 * Not compliant with VDE 0670 part 402 44 165 35.5 178 20 360 52 117 62 98.0 116 35.5 63 402 112 35.5 34 1.0 X 102 35 98 35.5 Minimum PreArcing 18 684 85 73.4 96 52.4 255 Joule Integral (I2t) W 1455 70 35.5 25 mΩ 23 23 35.5 Cold Resistance & Watts Loss in Free Air 116 36.8 133 35.0 271 Length Diameter Weight mm Maximum Operating mm kg 2.0 X 101 2.4 X 102 537 51 2.9 3.1 X 102 3.6 X 103 537 51 2.9 4.6 X 102 8.9 X 102 1.2 X 103 2.1 X 103 4.1 X 103 8.3 X 103 1.1 X104 1.2 X 103 5.1 X 103 8.2 X104 1.5 X 104 2.3 X 104 3.9 X 104 8.1 X 104 6.2 X 104 537 51 537 2.9 51 537 2.9 51 537 2.9 51 537 2.9 51 537 6.0 76 537 6.0 76 537 6.0 88 6.5 Cross-Reference MESA 36TDQSJ3.15 36TDQSJ6.3 36TDQSJ10 36TDQSJ16 36TDQSJ20 36TDQSJ25 N/A 67150.0060 67150.0100 67150.0160 67150.0200 67150.0250 N/A 3000813 3000813 3000813 3000813 3000813 36TXQEJ63 67150.0630 3002413 36TFQSJ31.5 36TFQSJ40 36TFQSJ50 67150.0320 67150.0400 67150.0500 N/A CF-36/6.3 CF-36/10 CF-36/16 CF-36/20 CF-36/25 3001613 3001613 3002413 (80N Striker) (50N Striker) 4266010 4266011 4266012 4265010 4265011 4265012 N/A 4266005 4266006 4266007 4266008 4266009 CF-36/31.5 CF-36/40 CF-36/50 CF-36/63 4266013 N/A 4265005 4265006 4265007 4265008 4265009 N/A 51006 549 M0 51006 550 M0 51006 551 M0 51006 552 M0 51006 553 M0 N/A ES 6515-006 ES 6515-010 ES 6515-016 ES 6515-020 ES 6515-025 N/A IB-D1 IB-D1 IB-D1 IB-D1 & IB-D2 IB-D1 & IB-D2 N/A 1YMB531006M0001 1YMB531006M0002 1YMB531006M0003 N/A 1YMB531006M0004 4265013 51006 557 M0 ES 6515-063 IB-D3 N/A 51006 554 M0 51006 555 M0 51006 556 M0 ES 6515-030 ES 6515-040 ES 6515-050 IB-D2 IB-D2 IB-D3 N/A 1YMB531006M0005 N/A Watts Loss Comparison Lowest Watts Loss Part Number 36TDQSJ3.15 36TDQSJ6.3 36TDQSJ10 36TDQSJ16 36TDQSJ20 36TDQSJ25 36TFQSJ31.5 36TFQSJ40 36TFQSJ50 36TXQEJ63 Watts Loss 34 44 52 62 85 96 116 133 271 Watts Loss Watts Loss 39 65 67 84 100 42 70 79 66 87 119 176 183 271 102 144 186 224 MESA Watts loss 39 50 98 120 133 171 207 198 240 Watts Loss 41 27 46 66 85 113 134 112 175 Watts Loss Watts Loss Watts Loss 171 207 198 135 198 237 125 164 195 39 50 98 120 133 240 54 48 94 110 118 268 32 55 82 85 87 235 Watts Loss 137 93 109 144 176 - Form No. 36kV DIN Page 2 of 10 Data sheet 720107 DRN APPD DATE VIRTUAL PRE-ARCING TIME IN SECONDS 0.01 0.1 1 10 100 1000 10000 10 4/6/07 MPJ DATE DRN 10/4/07 MPJ RE-DRAWN ON EXCEL. ECN11268 APPD BURTON-ON-THE-WOLDS LEIC, LE12 5TH, UK. TEL. 01509 882600 FAX 01509 882786 PF 1046 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps 3.15A ADDED. ECN11534 APPD DATE DRN 100000 FUSE TYPES: TDQ / TFQ 100 1000 10000 R.M.S. SYMMETRICAL PROSPECTIVE CURENT IN AMPERES G H 50A 40A 31.5A 25A 20A 16A 10A 6.3A 3.15A CURVES RELATE TO MEAN PRE_ARCING TIMES WITH A TOLERANCE OF ±10% ON CURRENT TIME- CURRENT CHARACTERISTIC FOR 36kV FUSE-LINKS MEDIUM VOLTAGE DIN Fuse-Links MV DIN Time Current Curves Form No. 36kV DIN Page 3 of 10 Data sheet 720107 APPD DATE DRN VIRTUAL PRE-ARCING TIME IN SECONDS 0.01 0.1 1 10 100 1000 10000 10 APPD DATE DRN DRN MPJ B FUSE TYPES: TXQ 10/4/07 RE-DRAWN ON EXCEL. ECN11268 APPD DATE BURTON-ON-THE-WOLDS LEIC, LE12 5TH, UK. TEL. 01509 882600 FAX 01509 882786 100 1000 10000 R.M.S. SYMMETRICAL PROSPECTIVE CURENT IN AMPERES 63A CURVES RELATE TO MEAN PRE_ARCING TIMES WITH A TOLERANCE OF ±10% ON CURRENT TIME- CURRENT CHARACTERISTIC FOR 36kV FUSE-LINKS PF 1253 100000 MEDIUM VOLTAGE DIN Fuse-Links 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps MV DIN Time Current Curves Form No. 36kV DIN Page 4 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links MV DIN 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps Cut-Off Curves REF. No. PF 2046 CUT-OFF CURRENT CHARACTERISTIC FOR 36kV FUSE-LINKS FUSE TYPE TDQ/TFQ NOTES 1. CURVES SHOW EXTREME MAXIMUM VALUES WHICH WILL NOT BE EXCEEDED UNDER CONDITIONS STATED IN 2 AND 3 BELOW. 2. FOR HIGH VALUES OF PROSPECTIVE CURRENT A SYMMETRICAL FAULT GIVES THE HIGHEST CUT-OFFCURRENT. FOR LOW VALUES OF PROSPECTIVE CURRENT, WHERE THERE IS LITTLE OR NO CURRENT LIMITATION, AN ASYMMETRICAL FAULT PASSES THE HIGHEST PEAKCURRENT. THE CURVES ARE THEREFORE BASED ON THE DEGREE OF ASYMMETRY WHICH GIVES THE MAXIMUM CUT-OFF CURRENT AT ANY PARTICULAR VALUE OF PROSPECTIVE CURRENT. 3. CURVES RELATE TO FREQUENCY OF 50 Hz AND A RECOVERY VOLTAGE EQUAL TO THE FUSE RATED VOLTAGE. 100000 PEAK CUT-OFF CURRENT IN AMPERE S 31.5A 50A 10000 1000 3.15A 100 100 DRN DATE APPD 40A 1000 6.3A 10A 16A 20A 25A 10000 100000 R.M.S. SYMMETRICAL PROSPECTIVE CURRENT IN AMPERES F DRN MPJ DATE 4/6/07 APPD 3.15A ADDED MPJ. ECN11534 E DRN MPJ DATE 21/3/07 APPD D RE-DRAWN IN EXCEL MPJ. ECN11268 PF2046 BURTON-ON-THE-WOLDS, LEICS., LE12 5TH, U.K. TEL +44 (0) 1509 882600 FAX +44 (0) 1509 882786 Form No. 36kV DIN Page 5 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links MV DIN 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps Cut-Off Curves 36kV REF. No. PF 2253 CUT-OFF CURRENT CHARACTERISTIC FOR 36kV FUSE-LINKS FUSE TYPE TXQ NOTES 1. CURVES SHOW EXTREME MAXIMUM VALUES WHICH WILL NOT BE EXCEEDED UNDER CONDITIONS STATED IN 2 AND 3 BELOW. 2. FOR HIGH VALUES OF PROSPECTIVE CURRENT A SYMMETRICAL FAULT GIVES THE HIGHEST CUT-OFFCURRENT. FOR LOW VALUES OF PROSPECTIVE CURRENT, WHERE THERE IS LITTLE OR NO CURRENT LIMITATION, AN ASYMMETRICAL FAULT PASSES THE HIGHEST PEAKCURRENT. THE CURVES ARE THEREFORE BASED ON THE DEGREE OF ASYMMETRY WHICH GIVES THE MAXIMUM CUT-OFF CURRENT AT ANY PARTICULAR VALUE OF PROSPECTIVE CURRENT. 3. CURVES RELATE TO FREQUENCY OF 50 Hz AND A RECOVERY VOLTAGE EQUAL TO THE FUSE RATED VOLTAGE. PEAK CUT-OFF CURRENT IN AMPERES 100000 63A 10000 1000 100 100 DRN DATE APPD C 1000 10000 R.M.S. SYMMETRICAL PROSPECTIVE CURRENT IN AMPERES DRN DATE APPD B DRN MPJ DATE 20/4/07 APPD 1st ISSUE MPJ ECN11268 A 100000 PF2253 BURTON-ON-THE-WOLDS, LEICS., LE12 5TH, U.K. TEL +44 (0) 1509 882600 FAX +44 (0) 1509 882786 Form No. 36kV DIN Page 6 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps MV DIN KEMA Certificate This certificate refers to SFQDJ 36kV fuse-links, which are electrically identical to the new T range, other than the fuses are sealed for outdoor use, have a brown ceramic body and use a 50N striker. Form No. 36kV DIN Page 7 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps MV DIN KEMA Certificate This certificate refers to SDQDJ 36kV fuse-links, which are electrically identical to the new T range, other than the fuses are sealed for outdoor use, have a brown ceramic body and use a 50N striker. Form No. 36kV DIN Page 8 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps MV DIN KEMA Report This certificate refers to SFQDJ 36kV fuse-links, which are electrically identical to the new T range, other than the fuses are sealed for outdoor use, have a brown ceramic body and use a 50N striker. Form No. 36kV DIN Page 9 of 10 Data sheet 720107 MEDIUM VOLTAGE DIN Fuse-Links 36kV, Current Limiting Back-Up Fuse-Links, 3.15 to 63 Amps MV DIN KEMA Report This certificate refers to SFQAJ 36kV fuse-links, which are electrically identical to the new T range, other than the fuses are sealed for outdoor use, have a brown ceramic body and use a 50N striker. Form No. 36kV DIN Page 10 of 10 Data sheet 720107 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Cooper Bussmann: 36TDQSJ16 36TDQSJ20 36TDQSJ25 36TFQSJ31.5 Eaton: 36TFQSJ40 36TFQSJ50
© Copyright 2026 Paperzz