[Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units Global Logical Node List for VAMP Protection Relays and Arc Protection Units About this Application Note The main purpose of this Application Note is to show the structure of all Logical Nodes that can be found in all VAMP Products Data Maps. Please note that there is no VAMP device in which you can find all Logical Nodes listed in this document. The subset of Logical Nodes found in each device is based on the VAMP Type and on the Ordering Code (e.g. LNs for Voltage Protection Functions or amount of LNs for Digital Inputs). This document uses for description of Protection Stages and Measurements, terminology and symbols found in VAMP Product manuals and uses terminology from IEC 61850 Standard for description of Data Objects. Note: All Logical Nodes listed in this document contain Mode, Behavior, Health and Name Plate Data Objects. This document does not intend to replace any official IEC 61850 documentation. Contact Information VAMP Technical Support [email protected] Version: 2.2 (22.9.2016) 1 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] Revision 2.2: Following Logical Nodes added: o o o o o 352 – Setting Group 3 353 – Setting Group 4 354 – Link 1 Down 355 – Link 2 Down 356 – Global trip (SG3GGIO135) (SG4GGIO136) (Lnk1DnGGIO1) (Lnk2DnGGIO1) (ALLPTRC1) Added: Appendix 1 - LLN0 and LPHD in Data Sets ANGEN.EN016 2 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units Index Logical Node name (Description in VAMPSET) 0. AR1ftGGIO16 (AR1 final trip) 1. AR2ftGGIO17 (AR2 final trip) 2. AR3ftGGIO18 (AR3 final trip) 3. AR4ftGGIO19 (AR4 final trip) 4. AR5RREC1 (Auto-reclose) (AR) 5. ARcftGGIO15 (AR critical final trip) 6. ARcreGGIO13 (AR critical request) 7. ARftGGIO14 (AR final trip) 8. ARlocGGIO2 (AR locked) 9. ARre1GGIO3 (AR request 1) 10. ARre2GGIO4 (AR request 2) 11. ARre3GGIO5 (AR request 3) 12. ARre4GGIO6 (AR request 4) 13. ARre5GGIO7 (AR request 5) 14. ARrunGGIO1 (AR running) 15. ARsh1GGIO8 (AR shot 1) 16. ARsh2GGIO9 (AR shot 2) 17. ARsh3GGIO10 (AR shot 3) 18. ARsh4GGIO11 (AR shot 4) 19. ARsh5GGIO12 (AR shot 5) 20. CBFPPIOC4 (CB failure protection) – Circuit Breaker Failure Protection (50BF) 21. CBWA1GGIO20 (CB wear alarm 1) 22. CBWA2GGIO21 (CB wear alarm 2) 23. CN01GGIO103 (Counter 1) 24. CN02GGIO104 (Counter 2) 25. CN03GGIO105 (Counter 3) 26. CN04GGIO106 (Counter 4) 27. CN05GGIO107 (Counter 5) 28. CN06GGIO108 (Counter 6) 29. CN07GGIO109 (Counter 7) 30. CN08GGIO110 (Counter 8) 31. CN09GGIO111 (Counter 9) 32. CN10GGIO112 (Counter 10) 33. CN11GGIO113 (Counter 11) 34. CN12GGIO114 (Counter 12) 35. CN13GGIO115 (Counter 13) 36. CN14GGIO116 (Counter 14) 37. CN15GGIO117 (Counter 15) 3 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 38. CN16GGIO118 (Counter 16) 39. CN17GGIO119 (Counter 17) 40. CN18GGIO120 (Counter 18) 41. CN19GGIO121 (Counter 19) 42. CN20GGIO122 (Counter 20) 43. CN21GGIO123 (Counter 21) 44. CN22GGIO124 (Counter 22) 45. CN23GGIO125 (Counter 23) 46. CN24GGIO126 (Counter 24) 47. CN25GGIO127 (Counter 25) 48. CN26GGIO128 (Counter 26) 49. CN27GGIO129 (Counter 27) 50. CN28GGIO130 (Counter 28) 51. CN29GGIO131 (Counter 29) 52. CN30GGIO132 (Counter 30) 53. CN31GGIO133 (Counter 31) 54. CN32GGIO134 (Counter 32) 55. CTAlmGGIO22 (CT alarm) 56. DEF1PTOC9 (IoDir>) – Directional Earth-Fault Protection Stage 1 (67N) 57. DEF2PTOC10 (IoDir>>) – Directional Earth-Fault Protection Stage 2 (67N) 58. dfdtPFRC1 (df/dt>) – Rate of Change of Frequency Protection Stage (81R) 59. DI01GGIO45 (Digital Input 1) 60. DI02GGIO46 (Digital Input 2) 61. DI03GGIO47 (Digital Input 3) 62. DI04GGIO48 (Digital Input 4) 63. DI05GGIO49 (Digital Input 5) 64. DI06GGIO50 (Digital Input 6) 65. DI07GGIO51 (Digital Input 7) 66. DI08GGIO52 (Digital Input 8) 67. DI09GGIO53 (Digital Input 9) 68. DI10GGIO54 (Digital Input 10) 69. DI11GGIO55 (Digital Input 11) 70. DI12GGIO56 (Digital Input 12) 71. DI13GGIO57 (Digital Input 13) 72. DI14GGIO58 (Digital Input 14) 73. DI15GGIO59 (Digital Input 15) 74. DI16GGIO60 (Digital Input 16) 75. DI17GGIO61 (Digital Input 17) 76. DI18GGIO62 (Digital Input 18) ANGEN.EN016 [Application note] 4 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 77. DI19GGIO63 (Digital Input 19) 78. DI20GGIO64 (Digital Input 20) 79. DI21GGIO65 (Digital Input 21) 80. DI22GGIO66 (Digital Input 22) 81. DI23GGIO67 (Digital Input 23) 82. DI24GGIO68 (Digital Input 24) 83. DI25GGIO69 (Digital Input 25) 84. DI26GGIO70 (Digital Input 26) 85. DI27GGIO71 (Digital Input 27) 86. DI28GGIO72 (Digital Input 28) 87. DI29GGIO73 (Digital Input 29) 88. DI30GGIO74 (Digital Input 30) 89. DI31GGIO75 (Digital Input 31) 90. DI32GGIO76 (Digital Input 32) 91. DOC1PTOC12 (IDir>) – Directional Overcurrent Protection Stage 1 (67) 92. DOC2PTOC13 (IDir>>) – Directional Overcurrent Protection Stage 2 (67) 93. DOC3PTOC14 (IDir>>>) – Directional Overcurrent Protection Stage 3 (67) 94. DOC4PTOC15 (IDir>>>>) – Directional Overcurrent Protection Stage 4 (67) 95. EF1PTOC4 (Io>) – Earth-Fault Protection Stage 1 (50N/51N) 96. EF2PTOC5 (Io>>) – Earth-Fault Protection Stage 2 (50N/51N) 97. EF3PTOC6 (Io>>>) – Earth-Fault Protection Stage 3 (50N/51N) 98. EF4PTOC7 (Io>>>>) – Earth-Fault Protection Stage 4 (50N/51N) 99. EnergyMMTR1 (Energy exported imported) 100. fdaMMXU9 (Frequency demand) 101. fMMXU8 (Frequency) 102. Har2PTOC11 (f2>) – Magnetizing Inrush Protection (68F2) 103. I3pdaMMXU3 (IL1, IL2, IL3 demand) 104. I3pMMXU1 (IL1, IL2, IL3) 105. I3prMMXU2 (IL1, IL2, IL3 RMS) 106. IArcPIOC1 (I Arc) – Arc Overcurrent Protection Stage (50AR) 107. Io1ArcPIOC2 (Io1 Arc) – Arc Earth-Fault Io1 Protection Stage (50NAR) 108. Io1MMXU11 (Io1) 109. Io2ArcPIOC3 (Io2 Arc) – Arc Earth-Fault Io2 Protection Stage (50NAR) 110. Io2MMXU12 (Io2) 111. IOC1GGIO142 (Fault current of I>) 112. IOC2GGIO143 (Fault current of I>>) 113. IOC3GGIO144 (Fault current of I>>>) 114. IoCMMXU13 (Io calculated) 115. L1fGGIO24 (Line 1 fault) 5 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 116. L2fGGIO25 (Line 2 fault) 117. L3fGGIO26 (Line 3 fault) 118. LdPDIF1 (87L) (LDP) – Line Differential Protection (87L) 119. LightSARC1 (Arc light on) 120. LO01GGIO77 (Logical output 1) 121. LO02GGIO78 (Logical output 2) 122. LO03GGIO79 (Logical output 3) 123. LO04GGIO80 (Logical output 4) 124. LO05GGIO81 (Logical output 5) 125. LO06GGIO82 (Logical output 6) 126. LO07GGIO83 (Logical output 7) 127. LO08GGIO84 (Logical output 8) 128. LO09GGIO85 (Logical output 9) 129. LO10GGIO86 (Logical output 10) 130. LO11GGIO87 (Logical output 11) 131. LO12GGIO88 (Logical output 12) 132. LO13GGIO89 (Logical output 13) 133. LO14GGIO90 (Logical output 14) 134. LO15GGIO91 (Logical output 15) 135. LO16GGIO92 (Logical output 16) 136. LO17GGIO93 (Logical output 17) 137. LO18GGIO94 (Logical output 18) 138. LO19GGIO95 (Logical output 19) 139. LO20GGIO96 (Logical output 20) 140. MotFStPMRI1 (Motor frequent start) 141. MotRnGGIO28 (Motor running) 142. MotStGGIO27 (Motor starting) 143. Obj1CSWI1 (Object 1) 144. Obj1RSYN1 (Synchrocheck object 1) 145. Obj2CSWI2 (Object 2) 146. Obj2RSYN2 (Synchrocheck object 2) 147. Obj3CSWI3 (Object 3) 148. Obj4CSWI4 (Object 4) 149. Obj5CSWI5 (Object 5) 150. Obj6CSWI6 (Object 6) 151. Obj7CSWI7 (Object 7) 152. Obj8CSWI8 (Object 8) 153. OC1PTOC1 (I>) – Overcurrent Protection Stage 1 (50/51) 154. OC2PTOC2 (I>>) – Overcurrent Protection Stage 2 (50/51) ANGEN.EN016 [Application note] 6 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 155. OC3PTOC3 (I>>>) – Overcurrent Protection Stage 3 (50/51) 156. OFUF1PTOF1 (f><) – Frequency Protection Stage 1 (81H/81L) 157. OFUF2PTOF2 (f>><<) – Frequency Protection Stage 2 (81H/81L) 158. OV1PTOV3 (U>) – Overvoltage Protection Stage 1 (59) 159. OV2PTOV4 (U>>) – Overvoltage Protection Stage 2 (59) 160. OV3PTOV5 (U>>>) – Overvoltage Protection Stage 3 (59) 161. PhRevPTOC16 (I2>>) – Reversal (Incorrect) Phase Sequence Protection (47) 162. PQSpdMMXU19 (P, Q, S, PF demand) 163. PQSpfMMXU18 (P, Q, S, PF) 164. PQSrdMMXU7 (P, Q, S, PF RMS demand) 165. PQSrMMXU6 (P, Q, S RMS) 166. PS1SGGIO29 (Programmable stage 1 start) 167. PS1TGGIO37 (Programmable stage 1 trip) 168. PS2SGGIO30 (Programmable stage 2 start) 169. PS2TGGIO38 (Programmable stage 2 trip) 170. PS3SGGIO31 (Programmable stage 3 start) 171. PS3TGGIO39 (Programmable stage 3 trip) 172. PS4SGGIO32 (Programmable stage 4 start) 173. PS4TGGIO40 (Programmable stage 4 trip) 174. PS5SGGIO33 (Programmable stage 5 start) 175. PS5TGGIO41 (Programmable stage 5 trip) 176. PS6SGGIO34 (Programmable stage 6 start) 177. PS6TGGIO42 (Programmable stage 6 trip) 178. PS7SGGIO35 (Programmable stage 7 start) 179. PS7TGGIO43 (Programmable stage 7 trip) 180. PS8SGGIO36 (Programmable stage 8 start) 181. PS8TGGIO44 (Programmable stage 8 trip) 182. ReLaGGIO141 (Release latches) 183. RevP1PDOP1 (P< reverse power) – Reverse (Dir.) Power Protection Stage 1 (32) 184. RevP2PDOP2 (P<< reverse power) – Reverse (Dir.) Power Protection Stage 2 (32) 185. SCfyMMXU14 (Synchrocheck fy) 186. SCfzMMXU15 (Synchrocheck fz) 187. SCUyMMXU16 (Synchrocheck Uy) 188. SCUzMMXU17 (Synchrocheck Uz) 189. SG1GGIO135 (Setting group 1) 190. SG2GGIO136 (Setting group 2) 191. StallPMSS1 (Ist>) – Stall Protection (48) 192. THDIMHAI1 (THD IL1, IL2, IL3) 193. THDUMHAI2 (THD Ua, Ub, Uc) 7 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 194. TOPTTR1 (T>) – Thermal Overload Protection (49) 195. U3pMMXU4 (UL1, UL2, UL3) 196. U3ppMMXU5 (U12, U23, U31) 197. UCPTUC1 (I<) – Undercurrent Protection (37) 198. UF1PTUF1 (f<) – Underfrequency Protection Stage 1 (81L) 199. UF2PTUF2 (f<<) – Underfrequency Protection Stage 2 (81L) 200. UIBCPTOC8 (I2> or I2/I1>) – Current Unbalance Protection Stage (46) 201. Uo1PTOV1 (Uo>) – Zero Sequence Voltage Protection Stage 1 (59N) 202. Uo2PTOV2 (Uo>>) – Zero Sequence Voltage Protection Stage 2 (59N) 203. UoMMXU10 (Uo) 204. UV1PTUV1 (U<) – Undervoltage Protection Stage 1 (27) 205. UV2PTUV2 (U<<) – Undervoltage Protection Stage 2 (27) 206. UV3PTUV3 (U<<<) – Undervoltage Protection Stage 3 (27) 207. VI1GGIO137 (Virtual input 1) 208. VI2GGIO138 (Virtual input 2) 209. VI3GGIO139 (Virtual input 3) 210. VI4GGIO140 (Virtual input 4) 211. VO1GGIO97 (Virtual output 1) 212. VO2GGIO98 (Virtual output 2) 213. VO3GGIO99 (Virtual output 3) 214. VO4GGIO100 (Virtual output 4) 215. VO5GGIO101 (Virtual output 5) 216. VO6GGIO102 (Virtual output 6) 217. VTAlmGGIO23 (VT alarm) 218. XGGIO145 (Fault reactance) 219. ZD1ePDIS6 (Z1e<) – Earth-fault Distance Protection Stage 1 (21N) 220. ZD1PDIS1 (Z1<) – Short Circuit Distance Protection Stage 1 (21) 221. ZD2ePDIS7 (Z2e<) – Earth-fault Distance Protection Stage 2 (21N) 222. ZD2PDIS2 (Z2<) – Short Circuit Distance Protection Stage 2 (21) 223. ZD3ePDIS8 (Z3e<) – Earth-fault Distance Protection Stage 3 (21N) 224. ZD3PDIS3 (Z3<) – Short Circuit Distance Protection Stage 3 (21) 225. ZD4ePDIS9 (Z4e<) – Earth-fault Distance Protection Stage 4 (21N) 226. ZD4PDIS4 (Z4<) – Short Circuit Distance Protection Stage 4 (21) 227. ZD5ePDIS10 (Z5e<) – Earth-fault Distance Protection Stage 5 (21N) 228. ZD5PDIS5 (Z5<) – Short Circuit Distance Protection Stage 5 (21) 229. EA01GGIO164 (External AI 1) 230. EA02GGIO165 (External AI 2) 231. EA03GGIO165 (External AI 3) 232. EA04GGIO166 (External AI 4) ANGEN.EN016 [Application note] 8 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 233. EA05GGIO167 (External AI 5) 234. EA06GGIO168 (External AI 6) 235. EA07GGIO169 (External AI 7) 236. EA08GGIO170 (External AI 8) 237. EA09GGIO171 (External AI 9) 238. EA10GGIO172 (External AI 10) 239. EA11GGIO173 (External AI 11) 240. EA12GGIO174 (External AI 12) 241. EA13GGIO175 (External AI 13) 242. EA14GGIO176 (External AI 14) 243. EA15GGIO177 (External AI 15) 244. EA16GGIO178 (External AI 16) 245. ED01GGIO146 (External DI 1) 246. ED02GGIO147 (External DI 2) 247. ED03GGIO148 (External DI 3) 248. ED04GGIO149 (External DI 4) 249. ED05GGIO150 (External DI 5) 250. ED06GGIO151 (External DI 6) 251. ED07GGIO152 (External DI 7) 252. ED08GGIO153 (External DI 8) 253. ED09GGIO154 (External DI 9) 254. ED10GGIO155 (External DI 10) 255. ED11GGIO156 (External DI 11) 256. ED12GGIO157 (External DI 12) 257. ED13GGIO158 (External DI 13) 258. ED14GGIO159 (External DI 14) 259. ED15GGIO160 (External DI 15) 260. ED16GGIO161 (External DI 16) 261. ED17GGIO162 (External DI 17) 262. ED18GGIO163 (External DI 18) 263. HIbMHAI6 (Harmonics IL1b, IL2b, IL3b) 264. HIMHAI3 (Harmonics IL1, IL2, IL3) 265. HUMHAI4 (Harmonics Ua, Ub, Uc) 266. I3pbMMXU20 (IL1b, IL2b, IL3b) 267. IL1b, IL2b, IL3b RMS (I3pbrMMXU22) 268. I3pDMMXU21 (IL1, IL2, IL3 Diff) 269. Id1PDIF2 (3dI>) – Differential Protection Stage 1 (87) 270. Id2PDIF3 (3dI>>) – Differential Protection Stage 2 (87) 271. ILbMSQI1 (ILb symmetrics) 9 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 272. ILbMSTA1 (ILb average) 273. ILbrMSTA2 (ILb RMS average) 274. IvPTOC20 (Iv>) – Voltage Restrained/Controlled Protection Stage (51V) 275. OC1bPTOC18 (Ib>) – Overcurrent Protection Stage 1 for Secondary Side (50/51) 276. OC2bPTOC19 (Ib>>) – Overcurrent Protection Stage 2 for Secondary Side (50/51) 277. OEPVPH1 (Uf>) – Volts/Hertz Overexcitation Protection Stage (24) 278. THDIbMHAI5 (THD IL1b, IL2b, IL3b) 279. UEPDUP1 (Q<) – Under Excitation Protection Stage (40) 280. UIBCbPTOC17 (I2b>) – Current Unb. Protection Stage for Secondary Side (46) 281. Uof3PTOC21 (Uof3<) – Stator Earth-fault Protection Stage (64F3) 282. UVPS1PTUV4 (U1<) – Positive Sequence Undervoltage Protection Stage 1 (27P) 283. UVPS2PTUV5 (U1<<) – Positive Sequence Undervoltage Protection Stage 2 (27P) 284. UX1PDUP2 (X<) – Underreactance Protection Stage 1 (21/40) 285. UX2PDUP3 (X<<) – Underreactance Protection Stage 2 (21/40) 286. UZ1PDIS11 (Z<) – Underimpedance Protection Stage 1 (21) 287. UZ2PDIS12 (Z<<) – Underimpedance Protection Stage 2 (21) 288. UssQVVR1 (Voltage Sag & Swell) 289. ARCIGGIO179 (L> inputs) 290. SILbMSQI2 (ILb symmetrics struct) 291. SIpbMMXU26 (IL1b-3b) 292. SIpbrMMXU28 (IL1b-3b RMS) 293. SIpdaMMXU25 (IL1-3 demand) 294. SIpDMMXU27 (IL1-3 Diff) 295. SIpMMXU23 (IL1-3) 296. SIprMMXU24 (IL1-3 RMS) 297. STHDIbMHAI8 (THD IL1b-3b) 298. STHDIMHAI7 (THD IL1-3) 299. STHDUMHAI9 (THD Uabc) 300. SUpMMXU29 (UL1-3) 301. SUppMMXU30 (U12-23-31) 302. ArcM1PIOC5 (Arc master stage 1) 303. ArcM2PIOC6 (Arc master stage 2) 304. ArcM3PIOC7 (Arc master stage 3) 305. ArcM4PIOC8 (Arc master stage 4) 306. ArcM5PIOC9 (Arc master stage 5) 307. ArcM6PIOC10 (Arc master stage 6) 308. ArcM7PIOC11 (Arc master stage 7) 309. ArcM8PIOC12 (Arc master stage 8) 310. IoIO1PTEF1 (IoInt>>) – Intermittent Transient Earth-fault Protection Stage (67NT) ANGEN.EN016 10 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 311. ZoneGGIO180 (Arc master Act Zones) 312. BiGGIO181 (Arc master Binary Inputs) 313. SensGGIO182 (Arc Master Sensors) 314. EvtGGIO183 (Generic events) 315. I3pGGIO184 (IL1, IL2, IL3 AI) 316. U3pGGIO185 (UL1, UL2, UL3 AI) 317. U3ppGGIO186 (U12, U23, U31 AI) 318. AMSTGGIO187 (Arc Sensors Info) 319. SPow3MMXU31 (3 phase P, Q, S, PF) 320. AlrmGGIO188 (Line alarm status) 321. LdI1PDIF4 (LdI>) – Line Differential Protection Stage 1 (87L) 322. LdI2PDIF5 (LdI>>) – Line Differential Protection Stage 2 (87L) 323. Har5PTOC22 (If5>) – Over Excitation Protection Stage (68F5) 324. NIStGGIO189 (GOOSE NI 1-16) 325. NIStGGIO190 (GOOSE NI 17-32) 326. NIStGGIO191 (GOOSE NI 33-48) 327. NIStGGIO192 (GOOSE NI 49-64) 328. NIGrGGIO193 (GOOSE Validity Groups) 329. GPubGGIO194 (GOOSE Publisher properties) 330. FTrpGGIO195 (Final TRIP for Objects) 331. DrRDRE1 (Disturbance recorder) 332. TmpGGIO196 (Temperature PT100) 333. SCRFLO1 (Incomer SC Fault Locator) 334. EFRFLO2 (Distance to Earth Fault) 335. VAIGGIO197 (GOOSE Virtual AI) 336. SCIGGIO198 (Current for Incomer SC) 337. DFLTGGIO199 (Fault distance indication) 338. FLRFLO3 (Feeder Fault Locator) 339. LED2GGIO200 (LEDs for 2xx and 5x series) 340. LED5GGIO201 (LEDs for 5x series) 341. ResGGIO202 (Remote Reset) 342. Stat1GGIO1 (OC Stages Ena/Grp Info) 343. Stat2GGIO1 (EF Stages Ena/Grp Info) 344. Stat3GGIO1 (OCb Stages Ena/Grp Info) 345. IFLTGGIO1 (Fault currents) 346. OCPTRC1 (OC trip) 347. CBAlmGGIO1 (CB Inactivity alarms) 348. EFPTRC2 (EF trip) 349. DrGGIO1 (Disturbance recorder) 11 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 350. CTGGIO1 (CT parameters) 351. CTIoGGIO1 (CT Io1 parameters) 352. SG3GGIO135 (Setting group 3) 353. SG4GGIO136 (Setting group 4) 354. Lnk1DnGGIO1 (Link 1 down) 355. Lnk2DnGGIO2 (Link 2 down) 356. ALLPTRC1 (Global trip) ANGEN.EN016 [Application note] 12 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 0. AR1ftGGIO16 (AR1 final trip) Data Object $ST$Ind Description Single point status for Final Trip of Auto-Reclosing Group 1 1. AR2ftGGIO17 (AR2 final trip) Data Object $ST$Ind Description Single point status for Final Trip of Auto-Reclosing Group 2 2. AR3ftGGIO18 (AR3 final trip) Data Object $ST$Ind Description Single point status for Final Trip of Auto-Reclosing Group 3 3. AR4ftGGIO19 (AR4 final trip) Data Object $ST$Ind Description Single point status for Final Trip of Auto-Reclosing Group 4 4. AR5RREC1 (Auto-reclose) (AR) Data Object $CO$BlkRec $ST$BlkRec $ST$Op $ST$AutoRecSt Description Controllable single point for enabling/disabling AutoReclosing Single point status for Auto-Reclosing (enabled/disabled) Single point status for Auto-Reclosing (running/not running) Double point status for Auto-Reclosing (Ready/In Progress/Successful) 5. ARcftGGIO15 (AR critical final trip) Data Object $ST$Ind Description Single point status for Auto-Reclosing Critical Final Trip 6. ARcreGGIO13 (AR critical request) Data Object $ST$Ind Description Single point status for Auto-Reclosing Critical Request 7. ARftGGIO14 (AR final trip) Data Object $ST$Ind Description Single point status for Auto-Reclosing Final Trip 8. ARlocGGIO2 (AR locked) Data Object $ST$Ind Description Single point status for Auto-Reclosing Locked 9. ARre1GGIO3 (AR request 1) Data Object $ST$Ind 13 Description Single point status for Auto-Reclosing Group 1 Request ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 10. ARre2GGIO4 (AR request 2) Data Object $ST$Ind Description Single point status for Auto-Reclosing Group 2 Request 11. ARre3GGIO5 (AR request 3) Data Object $ST$Ind Description Single point status for Auto-Reclosing Group 3 Request 12. ARre4GGIO6 (AR request 4) Data Object $ST$Ind Description Single point status for Auto-Reclosing Group 4 Request 13. ARre5GGIO7 (AR request 5) Data Object $ST$Ind Description Single point status for Auto-Reclosing Group 5 Request 14. ARrunGGIO1 (AR running) Data Object $ST$Ind Description Single point status for Auto-Reclosing (running/not running) 15. ARsh1GGIO8 (AR shot 1) Data Object $ST$Ind Description Single point status for Auto-Reclosing Shot 1 16. ARsh2GGIO9 (AR shot 2) Data Object $ST$Ind Description Single point status for Auto-Reclosing Shot 2 17. ARsh3GGIO10 (AR shot 3) Data Object $ST$Ind Description Single point status for Auto-Reclosing Shot 3 18. ARsh4GGIO11 (AR shot 4) Data Object $ST$Ind Description Single point status for Auto-Reclosing Shot 4 19. ARsh5GGIO12 (AR shot 5) Data Object $ST$Ind Description Single point status for Auto-Reclosing Shot 5 20. CBFPPIOC4 (CB failure protection) – Circuit Breaker Failure Protection (50BF) Data Object $ST$Str $ST$Op ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal 14 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 21. CBWA1GGIO20 (CB wear alarm 1) Data Object $ST$Ind Description Single point status for Circuit Breaker Wear Alarm 1 22. CBWA2GGIO21 (CB wear alarm 2) Data Object $ST$Ind Description Single point status for Circuit Breaker Wear Alarm 2 23. CN01GGIO103 (Counter 1) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 1 24. CN02GGIO104 (Counter 2) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 2 25. CN03GGIO105 (Counter 3) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 3 26. CN04GGIO106 (Counter 4) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 4 27. CN05GGIO107 (Counter 5) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 5 28. CN06GGIO108 (Counter 6) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 6 29. CN07GGIO109 (Counter 7) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 7 30. CN08GGIO110 (Counter 8) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 8 31. CN09GGIO111 (Counter 9) Data Object $ST$IntIn 15 Description Integer status for counter of State Change of Digital Input 9 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 32. CN10GGIO112 (Counter 10) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 10 33. CN11GGIO113 (Counter 11) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 11 34. CN12GGIO114 (Counter 12) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 12 35. CN13GGIO115 (Counter 13) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 13 36. CN14GGIO116 (Counter 14) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 14 37. CN15GGIO117 (Counter 15) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 15 38. CN16GGIO118 (Counter 16) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 16 39. CN17GGIO119 (Counter 17) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 17 40. CN18GGIO120 (Counter 18) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 18 41. CN19GGIO121 (Counter 19) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 19 42. CN20GGIO122 (Counter 20) Data Object $ST$IntIn ANGEN.EN016 Description Integer status for counter of State Change of Digital Input 20 16 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 43. CN21GGIO123 (Counter 21) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 21 44. CN22GGIO124 (Counter 22) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 22 45. CN23GGIO125 (Counter 23) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 23 46. CN24GGIO126 (Counter 24) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 24 47. CN25GGIO127 (Counter 25) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 25 48. CN26GGIO128 (Counter 26) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 26 49. CN27GGIO129 (Counter 27) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 27 50. CN28GGIO130 (Counter 28) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 28 51. CN29GGIO131 (Counter 29) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 29 52. CN30GGIO132 (Counter 30) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 30 53. CN31GGIO133 (Counter 31) Data Object $ST$IntIn 17 Description Integer status for counter of State Change of Digital Input 31 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 54. CN32GGIO134 (Counter 32) Data Object $ST$IntIn Description Integer status for counter of State Change of Digital Input 32 55. CTAlmGGIO22 (CT alarm) Data Object $ST$Ind Description Single point status for CT Alarm 56. DEF1PTOC9 (IoDir>) – Directional Earth-Fault Protection Stage 1 (67N) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 57. DEF2PTOC10 (IoDir>>) – Directional Earth-Fault Protection Stage 2 (67N) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 58. dfdtPFRC1 (df/dt>) – Rate of Change of Frequency Protection Stage (81R) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (Hz/s) Set point of type integer for Operation Delay 59. DI01GGIO45 (Digital Input 1) Data Object $ST$Ind Description Single point status for Digital Input 1 60. DI02GGIO46 (Digital Input 2) Data Object $ST$Ind ANGEN.EN016 Description Single point status for Digital Input 2 18 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 61. DI03GGIO47 (Digital Input 3) Data Object $ST$Ind Description Single point status for Digital Input 3 62. DI04GGIO48 (Digital Input 4) Data Object $ST$Ind Description Single point status for Digital Input 4 63. DI05GGIO49 (Digital Input 5) Data Object $ST$Ind Description Single point status for Digital Input 5 64. DI06GGIO50 (Digital Input 6) Data Object $ST$Ind Description Single point status for Digital Input 6 65. DI07GGIO51 (Digital Input 7) Data Object $ST$Ind Description Single point status for Digital Input 7 66. DI08GGIO52 (Digital Input 8) Data Object $ST$Ind Description Single point status for Digital Input 8 67. DI09GGIO53 (Digital Input 9) Data Object $ST$Ind Description Single point status for Digital Input 9 68. DI10GGIO54 (Digital Input 10) Data Object $ST$Ind Description Single point status for Digital Input 10 69. DI11GGIO55 (Digital Input 11) Data Object $ST$Ind Description Single point status for Digital Input 11 70. DI12GGIO56 (Digital Input 12) Data Object $ST$Ind Description Single point status for Digital Input 12 71. DI13GGIO57 (Digital Input 13) Data Object $ST$Ind 19 Description Single point status for Digital Input 13 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 72. DI14GGIO58 (Digital Input 14) Data Object $ST$Ind Description Single point status for Digital Input 14 73. DI15GGIO59 (Digital Input 15) Data Object $ST$Ind Description Single point status for Digital Input 15 74. DI16GGIO60 (Digital Input 16) Data Object $ST$Ind Description Single point status for Digital Input 16 75. DI17GGIO61 (Digital Input 17) Data Object $ST$Ind Description Single point status for Digital Input 17 76. DI18GGIO62 (Digital Input 18) Data Object $ST$Ind Description Single point status for Digital Input 18 77. DI19GGIO63 (Digital Input 19) Data Object $ST$Ind Description Single point status for Digital Input 19 78. DI20GGIO64 (Digital Input 20) Data Object $ST$Ind Description Single point status for Digital Input 20 79. DI21GGIO65 (Digital Input 21) Data Object $ST$Ind Description Single point status for Digital Input 21 80. DI22GGIO66 (Digital Input 22) Data Object $ST$Ind Description Single point status for Digital Input 22 81. DI23GGIO67 (Digital Input 23) Data Object $ST$Ind Description Single point status for Digital Input 23 82. DI24GGIO68 (Digital Input 24) Data Object $ST$Ind ANGEN.EN016 Description Single point status for Digital Input 24 20 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 83. DI25GGIO69 (Digital Input 25) Data Object $ST$Ind Description Single point status for Digital Input 25 84. DI26GGIO70 (Digital Input 26) Data Object $ST$Ind Description Single point status for Digital Input 26 85. DI27GGIO71 (Digital Input 27) Data Object $ST$Ind Description Single point status for Digital Input 27 86. DI28GGIO72 (Digital Input 28) Data Object $ST$Ind Description Single point status for Digital Input 28 87. DI29GGIO73 (Digital Input 29) Data Object $ST$Ind Description Single point status for Digital Input 29 88. DI30GGIO74 (Digital Input 30) Data Object $ST$Ind Description Single point status for Digital Input 30 89. DI31GGIO75 (Digital Input 31) Data Object $ST$Ind Description Single point status for Digital Input 31 90. DI32GGIO76 (Digital Input 32) Data Object $ST$Ind Description Single point status for Digital Input 32 91. DOC1PTOC12 (IDir>) – Directional Overcurrent Protection Stage 1 (67) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 21 Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] 92. DOC2PTOC13 (IDir>>) – Directional Overcurrent Protection Stage 2 (67) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 93. DOC3PTOC14 (IDir>>>) – Directional Overcurrent Protection Stage 3 (67) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 94. DOC4PTOC15 (IDir>>>>) – Directional Overcurrent Protection Stage 4 (67) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 95. EF1PTOC4 (Io>) – Earth-Fault Protection Stage 1 (50N/51N) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 96. EF2PTOC5 (Io>>) – Earth-Fault Protection Stage 2 (50N/51N) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 22 [Application note] Global Logical Node List for VAMP Protection Relays and Arc Protection Units 97. EF3PTOC6 (Io>>>) – Earth-Fault Protection Stage 3 (50N/51N) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 98. EF4PTOC7 (Io>>>>) – Earth-Fault Protection Stage 4 (50N/51N) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 99. EnergyMMTR1 (Energy exported imported) Data Object $ST$SupWh $ST$SupVArh $ST$DmdWh $ST$DmdVArh $CF$SupW$pulsQty $CF$SupVArh$pulsQty $CF$DmdWh$pulsQty $CF$DmdVArh$pulsQty $CF$SupWh$units$SIUnit $CF$SupVArh$units$SIUnit $CF$DmdWh$units$SIUnit $CF$DmdVArh$units$SIUnit $CF$SupWh$units$multiplier $CF$SupVArh$units$multiplier $CF$DmdWh$units$multiplier $CF$DmdVArh$units$multiplier 100. fdaMMXU9 (Frequency demand) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier 23 Description Integer status for Exported Energy Integer status for Exported Reactive Energy Integer status for Demand value of Exported Energy Integer status for Demand value of Exp. Reactive Energy Magnitude of the counted value per count for Exported Energy (1000) Magnitude of the counted value per count for Exported Reactive Energy (1000) Magnitude of the counted value per count for Demand value of Exported Energy. (1000) Magnitude of the counted value per count for Demand value of Exported Reactive Energy (1000) SI Unit for Exported Energy (Wh) SI Unit for Exported Reactive Energy (VArh) SI Unit for Demand value of Exported Energy (Wh) SI Unit for Demand value of Exported React. Energy (VArh) Unit multiplier value for Exported Energy Unit multiplier value for Exported Reactive Energy Unit multiplier value for Exported Energy Demand Unit multiplier value for Exported Reactive Energy Demand Description Measured value for Demand value of Frequency SI Unit for Demand value of Frequency (Hz) Unit multiplier value for Demand value of Frequency ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 101. fMMXU8 (Frequency) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier 102. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay I3pdaMMXU3 (IL1, IL2, IL3 demand) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 104. Description Measured value for Frequency SI Unit for Frequency (Hz) Unit multiplier value for Frequency Har2PTOC11 (f2>) – Magnetizing Inrush Protection (68F2) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $SP$StrVal$units$SIUnit $SP$OpDlTmms$setVal 103. [Application note] Description Measured value for Demand value of IL1 Measured value for Demand value of IL2 Measured value for Demand value of IL3 SI Unit for Demand value of IL1 (A) SI Unit for Demand value of IL2 (A) SI Unit for Demand value of IL3 (A) Unit multiplier value for Demand value of IL1 Unit multiplier value for Demand value of IL2 Unit multiplier value for Demand value of IL3 I3pMMXU1 (IL1, IL2, IL3) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier ANGEN.EN016 Description Measured value for IL1 Measured value for IL2 Measured value for IL3 SI Unit for IL1 (A) SI Unit for IL2 (A) SI Unit for IL3 (A) Unit multiplier value for IL1 Unit multiplier value for IL2 Unit multiplier value for IL3 24 [Application note] 105. I3prMMXU2 (IL1, IL2, IL3 RMS) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 106. Description Measured value for Io2 SI Unit for Io2 (A) Unit multiplier value for Io2 IOC1GGIO142 (Fault current of I>) Data Object $MX$AnIn 25 Description Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Io2MMXU12 (Io2) Data Object $MX$A$neut $CF$A$neut$units$SIUnit $CF$A$neut$units$multiplier 111. Description Measured value for Io1 SI Unit for Io1 (A) Unit multiplier value for Io1 Io2ArcPIOC3 (Io2 Arc) – Arc Earth-Fault Io2 Protection Stage (50NAR) Data Object $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit 110. Description Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Io1MMXU11 (Io1) Data Object $MX$A$neut $CF$A$neut$units$SIUnit $CF$A$neut$units$multiplier 109. Description Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Io1ArcPIOC2 (Io1 Arc) – Arc Earth-Fault Io1 Protection Stage (50NAR) Data Object $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit 108. Description Measured value for RMS value of IL1 Measured value for RMS value of IL2 Measured value for RMS value of IL3 SI Unit for RMS value of IL1 (A) SI Unit for RMS value of IL2 (A) SI Unit for RMS value of IL3 (A) Unit multiplier value for RMS value of IL1 Unit multiplier value for RMS value of IL2 Unit multiplier value for RMS value of IL3 IArcPIOC1 (I Arc) – Arc Overcurrent Protection Stage (50AR) Data Object $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit 107. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Fault Current of Overcurrent Stage 1 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 112. IOC2GGIO143 (Fault current of I>>) Data Object $MX$AnIn 113. Description Single point Status for Arc Light Detected LO01GGIO77 (Logical output 1) Data Object $ST$Ind 121. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Pick-up Setting Set point of type integer for Minimum Operation Delay LightSARC1 (Arc light on) Data Object $ST$FADet 120. Description Single point status for Line 3 fault LdPDIF1 (87L) (LDP) – Line Differential Protection (87L) Data Object $ST$Str $ST$Op $SP$LoSet$setVal $SP$MinOpTmms$setVal 119. Description Single point status for Line 2 fault L3fGGIO26 (Line 3 fault) Data Object $ST$Ind 118. Description Single point status for Line 1 fault L2fGGIO25 (Line 2 fault) Data Object $ST$Ind 117. Description Measured value for Io Calculated SI Unit for Io Calculated (A) Unit multiplier value for Io Calculated L1fGGIO24 (Line 1 fault) Data Object $ST$Ind 116. Description Measured value for Fault Current of Overcurrent Stage 3 IoCMMXU13 (Io calculated) Data Object $MX$A$res $CF$A$res$units$SIUnit $CF$A$res$units$multiplier 115. Description Measured value for Fault Current of Overcurrent Stage 2 IOC3GGIO144 (Fault current of I>>>) Data Object $MX$AnIn 114. [Application note] Description Single point status for Logic Output 1 state LO02GGIO78 (Logical output 2) Data Object $ST$Ind ANGEN.EN016 Description Single point status for Logic Output 2 state 26 [Application note] 122. LO03GGIO79 (Logical output 3) Data Object $ST$Ind 123. Description Single point status for Logic Output 12 state LO13GGIO89 (Logical output 13) Data Object $ST$Ind 27 Description Single point status for Logic Output 11 state LO12GGIO88 (Logical output 12) Data Object $ST$Ind 132. Description Single point status for Logic Output 10 state LO11GGIO87 (Logical output 11) Data Object $ST$Ind 131. Description Single point status for Logic Output 9 state LO10GGIO86 (Logical output 10) Data Object $ST$Ind 130. Description Single point status for Logic Output 8 state LO09GGIO85 (Logical output 9) Data Object $ST$Ind 129. Description Single point status for Logic Output 7 state LO08GGIO84 (Logical output 8) Data Object $ST$Ind 128. Description Single point status for Logic Output 6 state LO07GGIO83 (Logical output 7) Data Object $ST$Ind 127. Description Single point status for Logic Output 5 state LO06GGIO82 (Logical output 6) Data Object $ST$Ind 126. Description Single point status for Logic Output 4 state LO05GGIO81 (Logical output 5) Data Object $ST$Ind 125. Description Single point status for Logic Output 3 state LO04GGIO80 (Logical output 4) Data Object $ST$Ind 124. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Logic Output 13 state ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 133. LO14GGIO90 (Logical output 14) Data Object $ST$Ind 134. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Maximum Number of Starts MotRnGGIO28 (Motor running) Data Object $ST$Ind 142. Description Single point status for Logic Output 20 state MotFStPMRI1 (Motor frequent start) Data Object $ST$Op $ST$StrInh $SP$MaxNumStr$setVal 141. Description Single point status for Logic Output 19 state LO20GGIO96 (Logical output 20) Data Object $ST$Ind 140. Description Single point status for Logic Output 18 state LO19GGIO95 (Logical output 19) Data Object $ST$Ind 139. Description Single point status for Logic Output 17 state LO18GGIO94 (Logical output 18) Data Object $ST$Ind 138. Description Single point status for Logic Output 16 state LO17GGIO93 (Logical output 17) Data Object $ST$Ind 137. Description Single point status for Logic Output 15 state LO16GGIO92 (Logical output 16) Data Object $ST$Ind 136. Description Single point status for Logic Output 14 state LO15GGIO91 (Logical output 15) Data Object $ST$Ind 135. [Application note] Description Single point status for Motor Running MotStGGIO27 (Motor starting) Data Object $ST$Ind ANGEN.EN016 Description Single point status for Motor Starting 28 [Application note] 143. Obj1CSWI1 (Object 1) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 144. Description Controllable double point for position of Object 4 Double point status for position of Object 4 Single point status for Object 4 Open Blocked Single point status for Object 4 Closed Blocked Obj5CSWI5 (Object 5) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 29 Description Controllable double point for position of Object 3 Double point status for position of Object 3 Single point status for Object 3 Open Blocked Single point status for Object 3 Closed Blocked Obj4CSWI4 (Object 4) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 149. Description Single point status for Synchrocheck Status Single point status for Angle Difference Single point status for Synchronizing in Progress Obj3CSWI3 (Object 3) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 148. Description Controllable double point for position of Object 2 Double point status for position of Object 2 Single point status for Object 2 Open Blocked Single point status for Object 2 Closed Blocked Obj2RSYN2 (Synchrocheck object 2) Data Object $ST$Rel $ST$AngInd $ST$SynPrg 147. Description Single point status for Synchrocheck Status Single point status for Angle Difference Single point status for Synchronizing in Progress Obj2CSWI2 (Object 2) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 146. Description Controllable double point for position of Object 1 Double point status for position of Object 1 Single point status for Object 1 Open Blocked Single point status for Object 1 Closed Blocked Obj1RSYN1 (Synchrocheck object 1) Data Object $ST$Rel $ST$AngInd $ST$SynPrg 145. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Controllable double point for position of Object 5 Double point status for position of Object 5 Single point status for Object 5 Open Blocked Single point status for Object 5 Closed Blocked ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 150. Obj6CSWI6 (Object 6) Data Object $CO$Pos $ST$Pos $ST$BlkOpn $ST$BlkCls 151. $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Single point status for Start Signal OC2PTOC2 (I>>) – Overcurrent Protection Stage 2 (50/51) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 155. Description Double point status for position of Object 8 OC1PTOC1 (I>) – Overcurrent Protection Stage 1 (50/51) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact 154. Description Double point status for position of Object 7 Obj8CSWI8 (Object 8) Data Object $ST$Pos 153. Description Controllable double point for position of Object 6 Double point status for position of Object 6 Single point status for Object 6 Open Blocked Single point status for Object 6 Closed Blocked Obj7CSWI7 (Object 7) Data Object $ST$Pos 152. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay OC3PTOC3 (I>>>) – Overcurrent Protection Stage 3 (50/51) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 30 [Application note] 156. OFUF1PTOF1 (f><) – Frequency Protection Stage 1 (81H/81L) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 157. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay PhRevPTOC16 (I2>>) – Reversal (Incorrect) Phase Sequence Protection (47) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$Units$SIUnit $SP$OpDlTmms$setVal 31 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay OV3PTOV5 (U>>>) – Overvoltage Protection Stage 3 (59) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$Units$SIUnit $SP$OpDlTmms$setVal 161. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay OV2PTOV4 (U>>) – Overvoltage Protection Stage 2 (59) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $SP$StrVal$Units$SIUnit $SP$OpDlTmms$setVal 160. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (Hz) Set point of type integer for Operation Delay OV1PTOV3 (U>) – Overvoltage Protection Stage 1 (59) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$Units$SIUnit $SP$OpDlTmms$setVal 159. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (Hz) Set point of type integer for Operation Delay OFUF2PTOF2 (f>><<) – Frequency Protection Stage 2 (81H/81L) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 158. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 162. PQSpdMMXU19 (P, Q, S, PF demand) Data Object $MX$TotW $MX$TotVAr $MX$TotVA $MX$TotPF $CF$TotW$units$SIUnit $CF$TotVAr$units$SIUnit $CF$TotVA$units$SIUnit $CF$TotPF$units$SIUnit $CF$TotW$units$multiplier $CF$TotVAr$units$multiplier $CF$TotVA$units$multiplier $CF$TotPF$units$multiplier 163. Description Measured value for Demand value of Active Power Measured value for Demand value of Reactive Power Measured value for Demand value of Apparent Power Measured value for demand value of Power Factor SI Unit for Demand value of Active Power (W) SI Unit for Demand value of Reactive Power (Var) SI Unit for Demand value of Apparent Power (VA) SI Unit for Demand value of Power Factor (pu) Unit multiplier value for Demand value of Active Power Unit multiplier value for Demand value of Reactive Power Unit multiplier value for Demand value of Apparent Power Unit multiplier value for Demand value of Power Factor PQSpfMMXU18 (P, Q, S, PF) Data Object $MX$TotW $MX$TotVAr $MX$TotVA $MX$TotPF $CF$TotW$units$SIUnit $CF$TotVAr$units$SIUnit $CF$TotVA$units$SIUnit $CF$TotPF$units$SIUnit $CF$TotW$units$multiplier $CF$TotVAr$units$multiplier $CF$TotVA$units$multiplier $CF$TotPF$units$multiplier 164. [Application note] Description Measured value for Active Power Measured value for Reactive Power Measured value for Apparent Power Measured value for Power Factor SI Unit for Active Power (W) SI Unit for Reactive Power (Var) SI Unit for Apparent Power (VA) SI Unit for Power Factor (pu) Unit multiplier value for Active Power Unit multiplier value for Reactive Power Unit multiplier value for Apparent Power Unit multiplier value for Power Factor PQSrdMMXU7 (P, Q, S, PF RMS demand) Data Object $MX$TotW $MX$TotVAr $MX$TotVA $CF$TotW$units$SIUnit $CF$TotVAr$units$SIUnit $CF$TotVA$units$SIUnit $CF$TotW$units$multiplier $CF$TotVAr$units$multiplier $CF$TotVA$units$multiplier ANGEN.EN016 Description Measured value for RMS Demand value of Active Power Measured value for RMS Demand value of Reactive Power Measured value for RMS Demand value of Apparent Power SI Unit for RMS Demand value of Active Power (W) SI Unit for RMS Demand value of Reactive Power (Var) SI Unit for RMS Demand value of Apparent Power (VA) Unit multiplier value for RMS Demand value of Active Power Unit multiplier value for RMS Demand value of Reactive Power Unit multiplier value for RMS Demand value of Apparent Power 32 [Application note] 165. PQSrMMXU6 (P, Q, S RMS) Data Object $MX$TotW $MX$TotVAr $MX$TotVA $CF$TotW$units$SIUnit $CF$TotVAr$units$SIUnit $CF$TotVA$units$SIUnit $CF$TotW$units$multiplier $CF$TotVAr$units$multiplier $CF$TotVA$units$multiplier 166. Description Single point status for Trip Signal PS5SGGIO33 (Programmable stage 5 start) Data Object $ST$Ind 33 Description Single point status for Start Signal PS4TGGIO40 (Programmable stage 4 trip) Data Object $ST$Ind 174. Description Single point status for Trip Signal PS4SGGIO32 (Programmable stage 4 start) Data Object $ST$Ind 173. Description Single point status for Start Signal PS3TGGIO39 (Programmable stage 3 trip) Data Object $ST$Ind 172. Description Single point status for Trip Signal PS3SGGIO31 (Programmable stage 3 start) Data Object $ST$Ind 171. Description Single point status for Start Signal PS2TGGIO38 (Programmable stage 2 trip) Data Object $ST$Ind 170. Description Single point status for Trip Signal PS2SGGIO30 (Programmable stage 2 start) Data Object $ST$Ind 169. Description Single point status for Start Signal PS1TGGIO37 (Programmable stage 1 trip) Data Object $ST$Ind 168. Description Measured value for RMS value of Active Power Measured value for RMS value of Reactive Power Measured value for RMS value of Apparent Power SI Unit for RMS value of Active Power (W) SI Unit for RMS value of Reactive Power (VAr) SI Unit for RMS value of Apparent Power (VA) Unit multiplier value for RMS value of Active Power Unit multiplier value for RMS value of Reactive Power Unit multiplier value for RMS value of Apparent Power PS1SGGIO29 (Programmable stage 1 start) Data Object $ST$Ind 167. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Start Signal ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 175. PS5TGGIO41 (Programmable stage 5 trip) Data Object $ST$Ind 176. Description Single point status for Trip Signal ReLaGGIO141 (Release latches) Data Object $CO$SPCSO 183. Description Single point status for Start Signal PS8TGGIO44 (Programmable stage 8 trip) Data Object $ST$Ind 182. Description Single point status for Trip Signal PS8SGGIO36 (Programmable stage 8 start) Data Object $ST$Ind 181. Description Single point status for Start Signal PS7TGGIO43 (Programmable stage 7 trip) Data Object $ST$Ind 180. Description Single point status for Trip Signal PS7SGGIO35 (Programmable stage 7 start) Data Object $ST$Ind 179. Description Single point status for Start Signal PS6TGGIO42 (Programmable stage 6 trip) Data Object $ST$Ind 178. Description Single point status for Trip Signal PS6SGGIO34 (Programmable stage 6 start) Data Object $ST$Ind 177. [Application note] Description Controllable single point status for Releasing Latches RevP1PDOP1 (P< reverse power) – Reverse (Dir.) Power Protection Stage 1 (32) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay 34 [Application note] 184. RevP2PDOP2 (P<< reverse power) – Reverse (Dir.) Power Protection Stage 2 (32) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 185. Description Controllable single point status for Setting Group 1 Single point status for Setting Group 1 active SG2GGIO136 (Setting group 2) Data Object $CO$SPCSO $ST$SPCSO 35 Description Measured value for Synchrocheck Voltage 2 SI Unit for Synchrocheck Voltage 2 (V) Unit multiplier value for Synchrocheck Voltage 2 SG1GGIO135 (Setting group 1) Data Object $CO$SPCSO $ST$SPCSO 190. Description Measured value for Synchrocheck Voltage 1 SI Unit for Synchrocheck Voltage 1 (V) Unit multiplier value for Synchrocheck Voltage 1 SCUzMMXU17 (Synchrocheck Uz) Data Object $MX$PPV$phsAB $CF$PPV$phsAB$units$SIUnit $CF$PPV$phsAB$units$multiplier 189. Description Measured value for Synchrocheck Frequency 2 SI Unit for Synchrocheck Frequency 2 (Hz) Unit multiplier value for Synchrocheck Frequency 2 SCUyMMXU16 (Synchrocheck Uy) Data Object $MX$PPV$phsAB $CF$PPV$phsAB$units$SIUnit $CF$PPV$phsAB$units$multiplier 188. Description Measured value for Synchrocheck Frequency 1 SI Unit for Synchrocheck Frequency 1 (Hz) Unit multiplier value for Synchrocheck Frequency 1 SCfzMMXU15 (Synchrocheck fz) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier 187. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for the Pick-up Setting (%) Set point of type integer for Operation Delay SCfyMMXU14 (Synchrocheck fy) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier 186. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Controllable single point status for Setting Group 2 Single point status for Setting Group 2 active ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 191. StallPMSS1 (Ist>) – Stall Protection (48) Data Object $ST$Str $ST$Op $SP$SetA$setMag$f $CF$SetA$units$SIUnits $SP$SetTms$setVal 192. Description Measured value for Frequency Measured value for Total Harmonic Distortion of IL1 Measured value for Total Harmonic Distortion of IL2 Measured value for Total Harmonic Distortion of IL3 SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of IL1 (pu) SI Unit for Total Harmonic Distortion of IL2 (pu) SI Unit for Total Harmonic Distortion of IL3 (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of IL1 Unit multiplier value for Total Harmonic Distortion of IL2 Unit multiplier value for Total Harmonic Distortion of IL3 THDUMHAI2 (THD Ua, Ub, Uc) Data Object $MX$Hz $MX$ThdPhV$phsA $MX$ThdPhV$phsB $MX$ThdPhV$phsC $CF$Hz$units$SIUnit $CF$ThdPhV$phsA$units$SIUnit $CF$ThdPhV$phsB$units$SIUnit $CF$ThdPhV$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdPhV$phsA$units$multiplier $CF$ThdPhV$phsB$units$multiplier $CF$ThdPhV$phsC$units$multiplier 194. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Integer status setting for Operation Delay THDIMHAI1 (THD IL1, IL2, IL3) Data Object $MX$Hz $MX$ThdA$phsA $MX$ThdA$phsB $MX$ThdA$phsC $CF$Hz$units$SIUnit $CF$ThdA$phsA$units$SIUnit $CF$ThdA$phsB$units$SIUnit $CF$ThdA$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdA$phsA$units$multiplier $CF$ThdA$phsB$units$multiplier $CF$ThdA$phsC$units$multiplier 193. [Application note] Description Measured value for Frequency Measured value for Total Harmonic Distortion of Ua Measured value for Total Harmonic Distortion of Ub Measured value for Total Harmonic Distortion of Uc SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of Ua (pu) SI Unit for Total Harmonic Distortion of Ub (pu) SI Unit for Total Harmonic Distortion of Uc (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of Ua Unit multiplier value for Total Harmonic Distortion of Ub Unit multiplier value for Total Harmonic istortion of Uc TOPTTR1 (T>) – Thermal Overload Protection (49) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay 36 [Application note] 195. U3pMMXU4 (UL1, UL2, UL3) Data Object $MX$PhV$phsA $MX$PhV$phsB $MX$PhV$phsC $CF$PhV$phsA$units$SIUnit $CF$PhV$phsB$units$SIUnit $CF$PhV$phsC$units$SIUnit $CF$PhV$phsA$units$multiplier $CF$PhV$phsB$units$multiplier $CF$PhV$phsC$units$multiplier 196. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (Hz) Set point of type integer for Operation Delay UF2PTUF2 (f<<) – Underfrequency Protection Stage 2 (81L) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 37 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UF1PTUF1 (f<) – Underfrequency Protection Stage 1 (81L) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 199. Description Measured value for U12 Measured value for U23 Measured value for U31 SI Unit for U12 (V) SI Unit for U23 (V) SI Unit for U31 (V) Unit multiplier value for U12 Unit multiplier value for U23 Unit multiplier value for U31 UCPTUC1 (I<) – Undercurrent Protection (37) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 198. Description Measured value for UL1 Measured value for UL2 Measured value for UL3 SI Unit for UL1 (V) SI Unit for UL2 (V) SI Unit for UL3 (V) Unit multiplier value for UL1 Unit multiplier value for UL2 Unit multiplier value for UL3 U3ppMMXU5 (U12, U23, U31) Data Object $MX$PPV$phsAB $MX$PPV$phsBC $MX$PPV$phsCA $CF$PPV$phsAB$units$SIUnit $CF$PPV$phsBC$units$SIUnit $CF$PPV$phsCA$units$SIUnit $CF$PPV$phsAB$units$multiplier $CF$PPV$phsBC$units$multiplier $CF$PPV$phsCA$units$multiplier 197. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up setting (Hz) Set point of type integer for Operation Delay ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 200. UIBCPTOC8 (I2> or I2/I1>) – Current Unbalance Protection Stage (46) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 201. Description Measured value for Neutral Voltage SI Unit for Neutral Voltage (V) Unit multiplier value for Neutral Voltage UV1PTUV1 (U<) – Undervoltage Protection Stage 1 (27) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 205. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UoMMXU10 (Uo) Data Object $MX$PhV$neut $CF$PhV$neut$units$SIUnit $CF$PhV$neut$units$multiplier 204. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay Uo2PTOV2 (Uo>>) – Zero Sequence Voltage Protection Stage 2 (59N) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 203. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay Uo1PTOV1 (Uo>) – Zero Sequence Voltage Protection Stage 1 (59N) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$setMag$units$SIUnit $SP$OpDlTmms$setVal 202. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UV2PTUV2 (U<<) – Undervoltage Protection Stage 2 (27) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay 38 [Application note] 206. UV3PTUV3 (U<<<) – Undervoltage Protection Stage 3 (27) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $SP$StrVal$units$SIUnit $SP$OpDlTmms$setVal 207. Description Single point indication for Virtual Output 4 VO5GGIO101 (Virtual output 5) Data Object $ST$Ind 39 Description Single point indication for Virtual Output 3 VO4GGIO100 (Virtual output 4) Data Object $ST$Ind 215. Description Single point indication for Virtual Output 2 VO3GGIO99 (Virtual output 3) Data Object $ST$Ind 214. Description Single point indication for Virtual Output 1 VO2GGIO98 (Virtual output 2) Data Object $ST$Ind 213. Description Controllable single point status for Virtual Input 4 Single point indication for Virtual Input 4 VO1GGIO97 (Virtual output 1) Data Object $ST$Ind 212. Description Controllable single point status for Virtual Input 3 Single point indication for Virtual Input 3 VI4GGIO140 (Virtual input 4) Data Object $CO$SPCSO $ST$SPCSO 211. Description Controllable single point status for Virtual Input 2 Single point indication for Virtual Input 2 VI3GGIO139 (Virtual input 3) Data Object $CO$SPCSO $ST$SPCSO 210. Description Controllable single point status for Virtual Input 1 Single point indication for Virtual Input 1 VI2GGIO138 (Virtual input 2) Data Object $CO$SPCSO $ST$SPCSO 209. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay VI1GGIO137 (Virtual input 1) Data Object $CO$SPCSO $ST$SPCSO 208. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point indication for Virtual Output 5 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 216. VO6GGIO102 (Virtual output 6) Data Object $ST$Ind 217. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD2ePDIS7 (Z2e<) – Earth-fault Distance Protection Stage 2 (21N) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisGndRch$setMag$f 222. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD1PDIS1 (Z1<) – Short Circuit Distance Protection Stage 1 (21) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisPhRch$setMag$f 221. Description Measured value for Fault Reactance ZD1ePDIS6 (Z1e<) – Earth-fault Distance Protection Stage 1 (21N) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisGndRch$setMag$f 220. Description Single point status for VT Alarm XGGIO145 (Fault reactance) Data Object $MX$AnIn 219. Description Single point indication for Virtual Output 6 VTAlmGGIO23 (VT alarm) Data Object $ST$Ind 218. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD2PDIS2 (Z2<) – Short Circuit Distance Protection Stage 2 (21) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisPhRch$setMag$f ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter 40 [Application note] 223. ZD3ePDIS8 (Z3e<) – Earth-fault Distance Protection Stage 3 (21N) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisGndRch$setMag$f 224. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD5PDIS5 (Z5<) – Short Circuit Distance Protection Stage 5 (21) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisPhRch$setMag$f 41 Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD5ePDIS10 (Z5e<) – Earth-fault Distance Protection Stage 5 (21N) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisGndRch$setMag$f 228. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD4PDIS4 (Z4<) – Short Circuit Distance Protection Stage 4 (21) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisPhRch$setMag$f 227. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD4ePDIS9 (Z4e<) – Earth-fault Distance Protection Stage 4 (21N) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisGndRch$setMag$f 226. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ZD3PDIS3 (Z3<) – Short Circuit Distance Protection Stage 3 (21) Data Object $ST$Str $ST$Op $SP$OpDlTmms$setVal $SP$X1$setMag$f $SP$RisPhRch$setMag$f 225. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Operation Delay Set point of type floating point for X Setting Parameter Set point of type floating point for R Setting Parameter ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 229. EA01GGIO164 (External AI 1) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 230. Description Measured value for External Analog Input 6 SI Unit for External Analog Input 6 (pu) Unit multiplier value for External Analog Input 6 EA07GGIO169 (External AI 7) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 236. Description Measured value for External Analog Input 5 SI Unit for External Analog Input 5 (pu) Unit multiplier value for External Analog Input 5 EA06GGIO168 (External AI 6) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 235. Description Measured value for External Analog Input 4 SI Unit for External Analog Input 4 (pu) Unit multiplier value for External Analog Input 4 EA05GGIO167 (External AI 5) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 234. Description Measured value for External Analog Input 3 SI Unit for External Analog Input 3 (pu) Unit multiplier value for External Analog Input 3 EA04GGIO166 (External AI 4) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 233. Description Measured value for External Analog Input 2 SI Unit for External Analog Input 2 (pu) Unit multiplier value for External Analog Input 2 EA03GGIO165 (External AI 3) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 232. Description Measured value for External Analog Input 1 SI Unit for External Analog Input 1 (pu) Unit multiplier value for External Analog Input 1 EA02GGIO165 (External AI 2) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 231. [Application note] Description Measured value for External Analog Input 7 SI Unit for External Analog Input 7 (pu) Unit multiplier value for External Analog Input 7 EA08GGIO170 (External AI 8) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier ANGEN.EN016 Description Measured value for External Analog Input 8 SI Unit for External Analog Input 8 (pu) Unit multiplier value for External Analog Input 8 42 [Application note] 237. EA09GGIO171 (External AI 9) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 238. Description Measured value for External Analog Input 15 SI Unit for External Analog Input 15 (pu) Unit multiplier value for External Analog Input 15 EA16GGIO178 (External AI 16) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 43 Description Measured value for External Analog Input 14 SI Unit for External Analog Input 14 (pu) Unit multiplier value for External Analog Input 14 EA15GGIO177 (External AI 15) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 244. Description Measured value for External Analog Input 13 SI Unit for External Analog Input 13 (pu) Unit multiplier value for External Analog Input 13 EA14GGIO176 (External AI 14) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 243. Description Measured value for External Analog Input 12 SI Unit for External Analog Input 12 (pu) Unit multiplier value for External Analog Input 12 EA13GGIO175 (External AI 13) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 242. Description Measured value for External Analog Input 11 SI Unit for External Analog Input 11 (pu) Unit multiplier value for External Analog Input 11 EA12GGIO174 (External AI 12) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 241. Description Measured value for External Analog Input 10 SI Unit for External Analog Input 10 (pu) Unit multiplier value for External Analog Input 10 EA11GGIO173 (External AI 11) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 240. Description Measured value for External Analog Input 9 SI Unit for External Analog Input 9 (pu) Unit multiplier value for External Analog Input 9 EA10GGIO172 (External AI 10) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 239. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for External Analog Input 16 SI Unit for External Analog Input 16 (pu) Unit multiplier value for External Analog Input 16 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 245. ED01GGIO146 (External DI 1) Data Object $ST$Ind 246. Description Single point Indication for External Digital Input 9 ED10GGIO155 (External DI 10) Data Object $ST$Ind 255. Description Single point Indication for External Digital Input 8 ED09GGIO154 (External DI 9) Data Object $ST$Ind 254. Description Single point Indication for External Digital Input 7 ED08GGIO153 (External DI 8) Data Object $ST$Ind 253. Description Single point Indication for External Digital Input 6 ED07GGIO152 (External DI 7) Data Object $ST$Ind 252. Description Single point Indication for External Digital Input 5 ED06GGIO151 (External DI 6) Data Object $ST$Ind 251. Description Single point Indication for External Digital Input 4 ED05GGIO150 (External DI 5) Data Object $ST$Ind 250. Description Single point Indication for External Digital Input 3 ED04GGIO149 (External DI 4) Data Object $ST$Ind 249. Description Single point Indication for External Digital Input 2 ED03GGIO148 (External DI 3) Data Object $ST$Ind 248. Description Single point Indication for External Digital Input 1 ED02GGIO147 (External DI 2) Data Object $ST$Ind 247. [Application note] Description Single point Indication for External Digital Input 10 ED11GGIO156 (External DI 11) Data Object $ST$Ind ANGEN.EN016 Description Single point Indication for External Digital Input 11 44 [Application note] 256. ED12GGIO157 (External DI 12) Data Object $ST$Ind 257. Description Single point Indication for External Digital Input 18 HIbMHAI6 (Harmonics IL1b, IL2b, IL3b) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier $MX$HA$phsAHar[16] $MX$HA$phsBHar[16] $MX$HA$phsCHar[16] $CF$HA$evalTm $CF$HA$frequency $CF$HA$units$SIUnit $CF$HA$units$multiplier $CF$HA$numHar $CF$HA$numCyc 45 Description Single point Indication for External Digital Input 17 ED18GGIO163 (External DI 18) Data Object $ST$Ind 263. Description Single point Indication for External Digital Input 16 ED17GGIO162 (External DI 17) Data Object $ST$Ind 262. Description Single point Indication for External Digital Input 15 ED16GGIO161 (External DI 16) Data Object $ST$Ind 261. Description Single point Indication for External Digital Input 14 ED15GGIO160 (External DI 15) Data Object $ST$Ind 260. Description Single point Indication for External Digital Input 13 ED14GGIO159 (External DI 14) Data Object 9$ST$Ind 259. Description Single point Indication for External Digital Input 12 ED13GGIO158 (External DI 13) Data Object $ST$Ind 258. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Frequency SI Unit for Frequency Unit multiplier value for Frequency Measured values for Harmonics of Phase I’L1 Measured values for Harmonics of Phase I’L2 Measured values for Harmonics of Phase I’L3 Time Window (0) Nominal Frequency (50 Hz) SI Unit for Harmonics (pu) Unit multiplier value for Harmonics Number of Harmonics (15) Number of Cycles (1) ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 264. HIMHAI3 (Harmonics IL1, IL2, IL3) Data Object $MX$Hz $CF$Hz$units$SIUnit $CF$Hz$units$multiplier $MX$HA$phsAHar[16] $MX$HA$phsBHar[16] $MX$HA$phsCHar[16] $CF$HA$evalTm $CF$HA$frequency $CF$HA$units$SIUnit $CF$HA$units$multiplier $CF$HA$numHar $CF$HA$numCyc 265. Description Measured value for Frequency SI Unit for Frequency Unit multiplier value for Frequency Measured values for Harmonics of Phase IL1 Measured values for Harmonics of Phase IL2 Measured values for Harmonics of Phase IL3 Time Window (0) Nominal Frequency (50 Hz) SI Unit for Harmonics (pu) Unit multiplier value for Harmonics Number of Harmonics (15) Number of Cycles (1) HUMHAI4 (Harmonics Ua, Ub, Uc) Data Object $MX$Hz $CF$Hz$unit$SIUnit $CF$Hz$unit$multiplier $MX$HPhV$phsAHar[16] $MX$HPhV$phsBHar[16] $MX$HPhV$phsCHar[16] $CF$HA$evalTm $CF$HPhV$frequency $CF$HPhV$units$SIUnit $CF$HPhV$units$multiplier $CF$HPhV$numHar $CF$HPhV$numCyc 266. [Application note] Description Measured value for Frequency SI Unit for Frequency Unit multiplier value for Frequency Measured values for Harmonics of Phase Ua Measured values for Harmonics of Phase Ub Measured values for Harmonics of Phase Uc Time Window (0) Nominal Frequency (50 Hz) SI Unit for Harmonics (pu) Unit multiplier value for Harmonics Number of Harmonics (15) Number of Cycles (1) I3pbMMXU20 (IL1b, IL2b, IL3b) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier ANGEN.EN016 Description Measured value for I’L1 Measured value for I’L2 Measured value for I’L3 SI Unit for I’L1 (A) SI Unit for I’L2 (A) SI Unit for I’L3 (A) Unit multiplier value for I’L1 Unit multiplier value for I’L2 Unit multiplier value for I’L3 46 [Application note] 267. IL1b, IL2b, IL3b RMS (I3pbrMMXU22) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 268. Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Pick-up Setting ILbMSQI1 (ILb symmetrics) Data Object $MX$SeqA$c1 $MX$SeqA$c2 $MX$SeqA$c3 $CF$SeqA$c1$units$SIUnit $CF$SeqA$c2$units$SIUnit $CF$SeqA$c3$units$SIUnit $CF$SeqA$c1$units$multiplier $CF$SeqA$c2$units$multiplier $CF$SeqA$c3$units$multiplier 47 Description Single point status for Start Signal Single point status for Trip Signal Set point of type integer for Pick-up Setting Id2PDIF3 (3dI>>) – Differential Protection Stage 2 (87) Data Object $ST$Str $ST$Op $SP$LoSet$setVal 271. Description Measured value for IL1 and I’L1 Differential Measured value for IL2 and I’L2 Differential Measured value for IL3 and I’L3 Differential SI Unit for IL1 and I’L1 Differential (A) SI Unit for IL2 and I’L2 Differential (A) SI Unit for IL3 and I’L3 Differential (A) Unit multiplier value for IL1 and I’L1 Differential Unit multiplier value for IL2 and I’L2 Differential Unit multiplier value for IL3 and I’L3 Differential Id1PDIF2 (3dI>) – Differential Protection Stage 1 (87) Data Object $ST$Str $ST$Op $SP$LoSet$setVal 270. Description Measured value for RMS value of I’L1 Measured value for RMS value of I’L2 Measured value for RMS value of I’L3 SI Unit for RMS value of I’L1 (A) SI Unit for RMS value of I’L2 (A) SI Unit for RMS value of I’L3 (A) Unit multiplier value for RMS value of I’L1 Unit multiplier value for RMS value of I’L2 Unit multiplier value for RMS value of I’L3 I3pDMMXU21 (IL1, IL2, IL3 Diff) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 269. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Positive Sequence I’L Measured value for Negative Sequence I’L Measured value for Zero Sequence I’L SI Unit for Positive Sequence I’L (A) SI Unit for Negative Sequence I’L (A) SI Unit for Zero Sequence I’L (A) Unit multiplier value for Positive Sequence I’L Unit multiplier value for Negative Sequence I’L Unit multiplier value for Zero Sequence I’L ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 272. ILbMSTA1 (ILb average) Data Object $MX$AvAmps $MX$MaxAmps $MX$MinAmps $CF$AvAmps$units$SIUnit $CF$MaxAmps$units$SIUnit $CF$MinAmps$units$SIUnit $CF$AvAmps$units$multiplier $CF$MaxAmps$units$multiplier $CF$MinAmps$units$multiplier 273. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay OC1bPTOC18 (Ib>) – Overcurrent Protection Stage 1 for Secondary Side (50/51) Data Object $ST$Str $ST$Op $SP$TmACrv$setCharact $SP$TmACrv$setParA $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 276. Description Measured value for RMS average value of I’L SI Unit for RMS average value of I’L Unit multiplier value for RMS average value of I’L IvPTOC20 (Iv>) – Voltage Restrained/Controlled Protection Stage (51V) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 275. Description Measured value for I’L Average Measured value for I’L Maximum Measured value for I’L Minimum SI Unit for I’L Average (A) SI Unit for I’L Maximum (A) SI Unit for I’L Minimum (A) Unit multiplier value for I’L Average Unit multiplier value for I’L Maximum Unit multiplier value for I’L Minimum ILbrMSTA2 (ILb RMS average) Data Object $MX$AvAmps $CF$AvAmps$units$SIUnit $CF$AvAmps$units$multiplier 274. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of enumerated type for Operating Curve Type (combination of Delay Curve Family and Delay Type) Set point of type floating point for Inverse Time Coef. (k) Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay OC2bPTOC19 (Ib>>) – Overcurrent Protection Stage 2 for Secondary Side (50/51) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 48 [Application note] 277. OEPVPH1 (Uf>) – Volts/Hertz Overexcitation Protection Stage (24) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 278. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay Uof3PTOC21 (Uof3<) – Stator Earth-fault Protection Stage (64F3) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 49 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UIBCbPTOC17 (I2b>) – Current Unb. Protection Stage for Secondary Side (46) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 281. Description Measured value for Frequency Measured value for Total Harmonic Distortion of I’L1 Measured value for Total Harmonic Distortion of I’L2 Measured value for Total Harmonic Distortion of I’L3 SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of I’L1 (pu) SI Unit for Total Harmonic Distortion of I’L2 (pu) SI Unit for Total Harmonic Distortion of I’L3 (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of I’L1 Unit multiplier value for Total Harmonic Distortion of I’L2 Unit multiplier value for Total Harmonic Distortion of I’L3 UEPDUP1 (Q<) – Under Excitation Protection Stage (40) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 280. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay THDIbMHAI5 (THD IL1b, IL2b, IL3b) Data Object $MX$Hz $MX$ThdA$phsA $MX$ThdA$phsB $MX$ThdA$phsC $CF$Hz$units$SIUnit $CF$ThdA$phsA$units$SIUnit $CF$ThdA$phsB$units$SIUnit $CF$ThdA$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdA$phsA$units$multiplier $CF$ThdA$phsB$units$multiplier $CF$ThdA$phsC$units$multiplier 279. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 282. UVPS1PTUV4 (U1<) – Positive Sequence Undervoltage Protection Stage 1 (27P) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 283. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay UZ1PDIS11 (Z<) – Underimpedance Protection Stage 1 (21) Data Object $ST$Str $ST$Op $SP$PhStr$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 287. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay UX2PDUP3 (X<<) – Underreactance Protection Stage 2 (21/40) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 286. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UX1PDUP2 (X<) – Underreactance Protection Stage 1 (21/40) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 285. Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay UVPS2PTUV5 (U1<<) – Positive Sequence Undervoltage Protection Stage 2 (27P) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 284. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay UZ2PDIS12 (Z<<) – Underimpedance Protection Stage 2 (21) Data Object $ST$Str $ST$Op $SP$PhStr$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal ANGEN.EN016 Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (pu) Set point of type integer for Operation Delay 50 [Application note] 288. UssQVVR1 (Voltage Sag & Swell) Data Object $ST$VarStr$stVal $ST$DipStr$stVal $ST$SwlStr$stVal $ST$IntrStr$stVal $ST$VarEnd$stVal $MX$VVa1$mag$f $CF$VVa1$units$SIUnit $CF$VVa1$units$multiplier $MX$VVa2$mag$f $CF$VVa2$units$SIUnit $CF$VVa2$units$multiplier $MX$VVa3$mag$f $CF$VVa3$units$SIUnit $CF$VVa3$units$multiplier $MX$VVaTm$mag$f $CF$VVaTm$units$SIUnit $SP$DipStrVal$setMag$f $CF$DipStrVal$units$SIUnit $CF$DipStrVal$units$multiplier $SP$SwlStrVal$setMag$f $CF$SwlStrVal$units$SIUnit $SP$SwlStrVal$units$multiplier $SP$IntrStrVal$setMag$f $CF$IntrStrVal$units$SIUnit $CF$IntrStrVal$units$multiplier 289. Description Single point status for Arc Sensor 1 Single point status for Arc Sensor 2 Single point status for Arc BIO SILbMSQI2 (ILb symmetrics struct) Data Object $MX$SeqA$c1 $MX$SeqA$c2 $MX$SeqA$c3 $CF$SeqA$c1$units$SIUnit $CF$SeqA$c2$units$SIUnit $CF$SeqA$c3$units$SIUnit $CF$SeqA$c1$units$multiplier $CF$SeqA$c2$units$multiplier $CF$SeqA$c3$units$multiplier 51 Description Single point status for Voltage Variation in Progress Single point status for Voltage Sag (Active/Inactive) Single point status for Voltage Swell (Active/Inactive) Single point status for Voltage Interruption (Active/Inactive) Single point status for Voltage Variation Ended Measured value for Maximum Voltage Swell of Phase 1 SI Unit for Maximum Voltage Swell of Phase 1 Unit multiplier value for Maximum Voltage Swell of Phase 1 Measured value for Maximum Voltage Swell of Phase 2 SI Unit for Maximum Voltage Swell of Phase 2 Unit multiplier value for Maximum Voltage Swell of Phase 2 Measured value for Maximum Voltage Swell of Phase 3 SI Unit for Maximum Voltage Swell of Phase 3 Unit multiplier value for Maximum Voltage Swell of Phase 3 Measured value for Duration of Voltage Swell SI Unit for Duration of Voltage Swell Measured value for Voltage Sag Limit SI Unit for Voltage Sag Limit Unit multiplier value for Voltage Sag Limit Measured value for Voltage Swell Limit SI Unit for Voltage Swell Limit Unit multiplier value for Voltage Swell Limit Measured value for Low Limit of Voltage Interrupts SI Unit for Low Limit of Voltage Interrupts Unit multiplier value for Low Limit of Voltage Interrupts ARCIGGIO179 (L> inputs) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 290. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Positive Sequence I’L Measured value for Negative Sequence I’L Measured value for Zero Sequence IL SI Unit for Positive Sequence I’L (A) SI Unit for Negative Sequence I’L (A) SI Unit for Zero Sequence I’L (A) Unit multiplier value for Positive Sequence I’L Unit multiplier value for Negative Sequence I’L Unit multiplier value for Zero Sequence I’L ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 291. SIpbMMXU26 (IL1b-3b) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 292. Description Measured value for RMS value of I’L1 Measured value for RMS value of I’L2 Measured value for RMS value of I’L3 SI Unit for RMS value of I’L1 (A) SI Unit for RMS value of I’L2 (A) SI Unit for RMS value of I’L3 (A) Unit multiplier value for RMS value of I’L1 Unit multiplier value for RMS value of I’L2 Unit multiplier value for RMS value of I’L3 SIpdaMMXU25 (IL1-3 demand) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 294. Description Measured value for I’L1 Measured value for I’L2 Measured value for I’L3 SI Unit for I’L1 (A) SI Unit for I’L2 (A) SI Unit for I’L3 (A) Unit multiplier value for I’L1 Unit multiplier value for I’L2 Unit multiplier value for I’L3 SIpbrMMXU28 (IL1b-3b RMS) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 293. [Application note] Description Measured value for Demand value of IL1 Measured value for Demand value of IL2 Measured value for Demand value of IL3 SI Unit for Demand value of IL1 (A) SI Unit for Demand value of IL2 (A) SI Unit for Demand value of IL3 (A) Unit multiplier value for Demand value of IL1 Unit multiplier value for Demand value of IL2 Unit multiplier value for Demand value of IL3 SIpDMMXU27 (IL1-3 Diff) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier ANGEN.EN016 Description Measured value for IL1 and I’L1 Differential Measured value for IL2 and I’L2 Differential Measured value for IL3 and I’L3 Differential SI Unit for IL1 and I’L1 Differential (A) SI Unit for IL2 and I’L2 Differential (A) SI Unit for IL3 and I’L3 Differential (A) Unit multiplier value for IL1 and I’L1 Differential Unit multiplier value for IL2 and I’L2 Differential Unit multiplier value for IL3 and I’L3 Differential 52 [Application note] 295. SIpMMXU23 (IL1-3) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 296. Description Measured value for RMS value of IL1 Measured value for RMS value of IL2 Measured value for RMS value of IL3 SI Unit for RMS value of IL1 (A) SI Unit for RMS value of IL2 (A) SI Unit for RMS value of IL3 (A) Unit multiplier value for RMS value of IL1 Unit multiplier value for RMS value of IL2 Unit multiplier value for RMS value of IL3 STHDIbMHAI8 (THD IL1b-3b) Data Object $MX$Hz $MX$ThdA$phsA $MX$ThdA$phsB $MX$ThdA$phsC $CF$Hz$units$SIUnit $CF$ThdA$phsA$units$SIUnit $CF$ThdA$phsB$units$SIUnit $CF$ThdA$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdA$phsA$units$multiplier $CF$ThdA$phsB$units$multiplier $CF$ThdA$phsC$units$multiplier 53 Description Measured value for IL1 Measured value for IL2 Measured value for IL3 SI Unit for IL1 (A) SI Unit for IL2 (A) SI Unit for IL3 (A) Unit multiplier value for IL1 Unit multiplier value for IL2 Unit multiplier value for IL3 SIprMMXU24 (IL1-3 RMS) Data Object $MX$A$phsA $MX$A$phsB $MX$A$phsC $CF$A$phsA$units$SIUnit $CF$A$phsB$units$SIUnit $CF$A$phsC$units$SIUnit $CF$A$phsA$units$multiplier $CF$A$phsB$units$multiplier $CF$A$phsC$units$multiplier 297. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Frequency Measured value for Total Harmonic Distortion of I’L1 Measured value for Total Harmonic Distortion of I’L2 Measured value for Total Harmonic Distortion of I’L3 SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of I’L1 (pu) SI Unit for Total Harmonic Distortion of I’L2 (pu) SI Unit for Total Harmonic Distortion of I’L3 (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of I’L1 Unit multiplier value for Total Harmonic Distortion of I’L2 Unit multiplier value for Total Harmonic Distortion of I’L3 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 298. STHDIMHAI7 (THD IL1-3) Data Object $MX$Hz $MX$ThdA$phsA $MX$ThdA$phsB $MX$ThdA$phsC $CF$Hz$units$SIUnit $CF$ThdA$phsA$units$SIUnit $CF$ThdA$phsB$units$SIUnit $CF$ThdA$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdA$phsA$units$multiplier $CF$ThdA$phsB$units$multiplier $CF$ThdA$phsC$units$multiplier 299. Description Measured value for Frequency Measured value for Total Harmonic Distortion of IL1 Measured value for Total Harmonic Distortion of IL2 Measured value for Total Harmonic Distortion of IL3 SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of IL1 (pu) SI Unit for Total Harmonic Distortion of IL2 (pu) SI Unit for Total Harmonic Distortion of IL3 (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of IL1 Unit multiplier value for Total Harmonic Distortion of IL2 Unit multiplier value for Total Harmonic Distortion of IL3 STHDUMHAI9 (THD Uabc) Data Object $MX$Hz $MX$ThdPhV$phsA $MX$ThdPhV$phsB $MX$ThdPhV$phsC $CF$Hz$units$SIUnit $CF$ThdPhV$phsA$units$SIUnit $CF$ThdPhV$phsB$units$SIUnit $CF$ThdPhV$phsC$units$SIUnit $CF$Hz$units$multiplier $CF$ThdPhV$phsA$units$multiplier $CF$ThdPhV$phsB$units$multiplier $CF$ThdPhV$phsC$units$multiplier 300. [Application note] Description Measured value for Frequency Measured value for Total Harmonic Distortion of Ua Measured value for Total Harmonic Distortion of Ub Measured value for Total Harmonic Distortion of Uc SI Unit for Frequency (Hz) SI Unit for Total Harmonic Distortion of Ua (pu) SI Unit for Total Harmonic Distortion of Ub (pu) SI Unit for Total Harmonic Distortion of Uc (pu) Unit multiplier value for Frequency Unit multiplier value for Total Harmonic Distortion of Ua Unit multiplier value for Total Harmonic Distortion of Ub Unit multiplier value for Total Harmonic Distortion of Uc SUpMMXU29 (UL1-3) Data Object $MX$PhV$phsA $MX$PhV$phsB $MX$PhV$phsC $CF$PPV$phsAB$units$SIUnit $CF$PPV$phsBC$units$SIUnit $CF$PPV$phsCA$units$SIUnit $CF$PhV$phsA$units$multiplier $CF$PhV$phsB$units$multiplier $CF$PhV$phsC$units$multiplier ANGEN.EN016 Description Measured value for UL1 Measured value for UL2 Measured value for UL3 SI Unit for UL1 (V) SI Unit for UL2 (V) SI Unit for UL3 (V) Unit multiplier value for UL1 Unit multiplier value for UL2 Unit multiplier value for UL3 54 [Application note] 301. SUppMMXU30 (U12-23-31) Data Object $MX$PPV$phsAB $MX$PPV$phsBC $MX$PPV$phsCA $CF$PPV$phsAB$units$SIUnit $CF$PPV$phsBC$units$SIUnit $CF$PPV$phsCA$units$SIUnit $CF$PPV$phsAB$units$multiplier $CF$PPV$phsBC$units$multiplier $CF$PPV$phsCA$units$multiplier 302. Description Single point status for Trip Signal ArcM8PIOC12 (Arc master stage 8) Data Object $ST$Op 55 Description Single point status for Trip Signal ArcM7PIOC11 (Arc master stage 7) Data Object $ST$Op 309. Description Single point status for Trip Signal ArcM6PIOC10 (Arc master stage 6) Data Object $ST$Op 308. Description Single point status for Trip Signal ArcM5PIOC9 (Arc master stage 5) Data Object $ST$Op 307. Description Single point status for Trip Signal ArcM4PIOC8 (Arc master stage 4) Data Object $ST$Op 306. Description Single point status for Trip Signal ArcM3PIOC7 (Arc master stage 3) Data Object $ST$Op 305. Description Single point status for Trip Signal ArcM2PIOC6 (Arc master stage 2) Data Object $ST$Op 304. Description Measured value for U12 Measured value for U23 Measured value for U31 SI Unit for U12 (V) SI Unit for U23 (V) SI Unit for U31 (V) Unit multiplier value for U12 Unit multiplier value for U23 Unit multiplier value for U31 ArcM1PIOC5 (Arc master stage 1) Data Object $ST$Op 303. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Trip Signal ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 310. IoIO1PTEF1 (IoInt>>) – Intermittent Transient Earth-fault Protection Stage (67NT) Data Object $ST$Str $ST$Op 311. Description Single point status for Start Signal Single point status for Trip Signal ZoneGGIO180 (Arc master Act Zones) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 312. Description Single point status for Arc Master Binary Input 1 Single point status for Arc Master Binary Input 2 Single point status for Arc Master Binary Input 3 SensGGIO182 (Arc Master Sensors) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 314. Description Single point status for Arc Master Zone 1 Single point status for Arc Master Zone 2 Single point status for Arc Master Zone 3 Single point status for Arc Master Zone 4 Single point status for Arc Master Zone 5 BiGGIO181 (Arc master Binary Inputs) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 313. [Application note] Description Single point status for Arc Master Sensor 1 Single point status for Arc Master Sensor 2 Single point status for Arc Master Sensor 3 Single point status for Arc Master Sensor 4 Single point status for Arc Master Sensor 5 Single point status for Arc Master Sensor 6 Single point status for Arc Master Sensor 7 Single point status for Arc Master Sensor 8 Single point status for Arc Master Sensor 9 Single point status for Arc Master Sensor 10 EvtGGIO183 (Generic events) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 ANGEN.EN016 Description Single point status for Generic Event Index 1 Single point status for Generic Event Index 2 Single point status for Generic Event Index 3 Single point status for Generic Event Index 4 Single point status for Generic Event Index 5 Single point status for Generic Event Index 6 Single point status for Generic Event Index 7 Single point status for Generic Event Index 8 56 [Application note] 315. I3pGGIO184 (IL1, IL2, IL3 AI) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn1$units$multiplier $CF$AnIn2$units$multiplier $CF$AnIn3$units$multiplier 316. Description Measured value for UL1 Measured value for UL2 Measured value for UL3 SI Unit for UL1 (V) SI Unit for UL2 (V) SI Unit for UL3 (V) Unit multiplier value for UL1 Unit multiplier value for UL2 Unit multiplier value for UL3 U3ppGGIO186 (U12, U23, U31 AI) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn1$units$multiplier $CF$AnIn2$units$multiplier $CF$AnIn3$units$multiplier 57 Description Measured value for IL1 Measured value for IL2 Measured value for IL3 SI Unit for IL1 (A) SI Unit for IL2 (A) SI Unit for IL3 (A) Unit multiplier value for IL1 Unit multiplier value for IL2 Unit multiplier value for IL3 U3pGGIO185 (UL1, UL2, UL3 AI) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn1$units$multiplier $CF$AnIn2$units$multiplier $CF$AnIn3$units$multiplier 317. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for U12 Measured value for U23 Measured value for U31 SI Unit for U12 (V) SI Unit for U23 (V) SI Unit for U31 (V) Unit multiplier value for U12 Unit multiplier value for U23 Unit multiplier value for U31 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 318. [Application note] AMSTGGIO187 (Arc Sensors Info) Data Object $ST$IntIn1 $ST$IntIn2 $ST$IntIn3 $ST$IntIn4 $ST$IntIn5 $ST$IntIn6 $ST$IntIn7 $ST$IntIn8 $ST$IntIn9 $ST$IntIn10 $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 ANGEN.EN016 Description Integer Status for Number of Activated Light Sensor Input in I/O Unit Integer Status for Address of Activated Light Sensor Input in I/O Unit Integer Status for Number of Activated Current Sensor Input in I/O Unit Integer Status for Address of Activated Channel Sensor Input in I/O Unit Integer Status for Number of Malfunctioning Sensor Input in I/O Unit Integer Status for Address Number of Malfunctioning Sensor Input in I/O Unit Integer Status for Activated Sensor Input in I/O Unit Integer Status for Address of the I/O Unit Integer Status for Number of Activated Sensor Input in I/O Unit Integer Status for I/O Unit Address of the Unit Single point status for Light Detection of a Sensor in I/O Unit Single point status for Current Detection of a Sensor in I/O Unit Single point status for Malfunction/Disconnection of Sensor in I/O Unit Single point status for ArcI/O Communication Link Down Single point status for RS-485 Communication Link Down 58 [Application note] 319. SPow3MMXU31 (3 phase P, Q, S, PF) Data Object $MX$W$phsA $MX$W$phsB $MX$W$phsC $CF$W$phsA$units$SIUnit $CF$W$phsB$units$SIUnit $CF$W$phsC$units$SIUnit $CF$W$phsA$units$multiplier $CF$W$phsB$units$multiplier $CF$W$phsC$units$multiplier $MX$VAr$phsA $MX$VAr$phsB $MX$VAr$phsC $CF$VAr$phsA$units$SIUnit $CF$VAr$phsB$units$SIUnit $CF$VAr$phsC$units$SIUnit $CF$VAr$phsA$units$multiplier $CF$VAr$phsB$units$multiplier $CF$VAr$phsC$units$multiplier $MX$VA$phsA $MX$VA$phsB $MX$VA$phsC $CF$VA$phsA$units$SIUnit $CF$VA$phsB$units$SIUnit $CF$VA$phsC$units$SIUnit $CF$VA$phsA$units$multiplier $CF$VA$phsB$units$multiplier $CF$VA$phsC$units$multiplier $MX$PF$phsA $MX$PF$phsB $MX$PF$phsC $CF$PF$phsA$units$SIUnit $CF$PF$phsB$units$SIUnit $CF$PF$phsC$units$SIUnit $CF$PF$phsA$units$multiplier $CF$PF$phsB$units$multiplier $CF$PF$phsC$units$multiplier 320. Description Measured value for Active Power for Phase 1 Measured value for Active Power for Phase 2 Measured value for Active Power for Phase 3 SI Unit for Active Power for Phase 1 (W) SI Unit for Active Power for Phase 2 (W) SI Unit for Active Power for Phase 3 (W) Unit multiplier value for Active Power for Phase 1 Unit multiplier value for Active Power for Phase 2 Unit multiplier value for Active Power for Phase 3 Measured value for Reactive Power for Phase 1 Measured value for Reactive Power for Phase 2 Measured value for Reactive Power for Phase 3 SI Unit for Reactive Power for Phase 1 (VAr) SI Unit for Reactive Power for Phase 2 (VAr) SI Unit for Reactive Power for Phase 3 (VAr) Unit multiplier value for Reactive Power for Phase 1 Unit multiplier value for Reactive Power for Phase 2 Unit multiplier value for Reactive Power for Phase 3 Measured value for Apparent Power for Phase 1 Measured value for Apparent Power for Phase 2 Measured value for Apparent Power for Phase 3 SI Unit for Apparent Power for Phase 1 (VA) SI Unit for Apparent Power for Phase 2 (VA) SI Unit for Apparent Power for Phase 3 (VA) Unit multiplier value for Apparent Power for Phase 1 Unit multiplier value for Apparent Power for Phase 2 Unit multiplier value for Apparent Power for Phase 3 Measured value for Power Factor for Phase 1 Measured value for Power Factor for Phase 2 Measured value for Power Factor for Phase 3 SI Unit for Power Factor for Phase 1 (pu) SI Unit for Power Factor for Phase 2 (pu) SI Unit for Power Factor for Phase 3 (pu) Unit multiplier value for Power Factor for Phase 1 Unit multiplier value for Power Factor for Phase 2 Unit multiplier value for Power Factor for Phase 3 AlrmGGIO188 (Line alarm status) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 59 Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Alarm in Line 1 Single point status for Alarm in Line 2 Single point status for Alarm in Line 3 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 321. LdI1PDIF4 (LdI>) – Line Differential Protection Stage 1 (87L) Data Object $ST$Op1 $ST$Op2 $SP$LoSet$setVal 322. Description Single point status for Trip Signal Single point status for Sympathy Trip Signal Set point of type integer point for Pick-up Setting Har5PTOC22 (If5>) – Over Excitation Protection Stage (68F5) Data Object $ST$Str $ST$Op $SP$StrVal$setMag$f $CF$StrVal$units$SIUnit $SP$OpDlTmms$setVal 324. Description Single point status for Trip Signal Single point status for Sympathy Trip Signal Set point of type integer point for Pick-up Setting LdI2PDIF5 (LdI>>) – Line Differential Protection Stage 2 (87L) Data Object $ST$Op1 $ST$Op2 $SP$LoSet$setVal 323. [Application note] Description Single point status for Start Signal Single point status for Trip Signal Set point of type floating point for Pick-up Setting SI Unit for Pick-up Setting (%) Set point of type integer for Operation Delay NIStGGIO189 (GOOSE NI 1-16) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 $ST$Ind11 $ST$Ind12 $ST$Ind13 $ST$Ind14 $ST$Ind15 $ST$Ind16 ANGEN.EN016 Description Single point status for NI 1 Single point status for NI 2 Single point status for NI 3 Single point status for NI 4 Single point status for NI 5 Single point status for NI 6 Single point status for NI 7 Single point status for NI 8 Single point status for NI 9 Single point status for NI 10 Single point status for NI 11 Single point status for NI 12 Single point status for NI 13 Single point status for NI 14 Single point status for NI 15 Single point status for NI 16 60 [Application note] 325. NIStGGIO190 (GOOSE NI 17-32) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 $ST$Ind11 $ST$Ind12 $ST$Ind13 $ST$Ind14 $ST$Ind15 $ST$Ind16 326. Description Single point status for NI 17 Single point status for NI 18 Single point status for NI 19 Single point status for NI 20 Single point status for NI 21 Single point status for NI 22 Single point status for NI 23 Single point status for NI 24 Single point status for NI 25 Single point status for NI 26 Single point status for NI 27 Single point status for NI 28 Single point status for NI 29 Single point status for NI 30 Single point status for NI 31 Single point status for NI 32 NIStGGIO191 (GOOSE NI 33-48) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 $ST$Ind11 $ST$Ind12 $ST$Ind13 $ST$Ind14 $ST$Ind15 $ST$Ind16 61 Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for NI 33 Single point status for NI 34 Single point status for NI 35 Single point status for NI 36 Single point status for NI 37 Single point status for NI 38 Single point status for NI 39 Single point status for NI 40 Single point status for NI 41 Single point status for NI 42 Single point status for NI 43 Single point status for NI 44 Single point status for NI 45 Single point status for NI 46 Single point status for NI 47 Single point status for NI 48 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 327. NIStGGIO192 (GOOSE NI 49-64) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 $ST$Ind11 $ST$Ind12 $ST$Ind13 $ST$Ind14 $ST$Ind15 $ST$Ind16 328. Description Single point status for NI 49 Single point status for NI 50 Single point status for NI 51 Single point status for NI 52 Single point status for NI 53 Single point status for NI 54 Single point status for NI 55 Single point status for NI 56 Single point status for NI 57 Single point status for NI 58 Single point status for NI 59 Single point status for NI 60 Single point status for NI 61 Single point status for NI 62 Single point status for NI 63 Single point status for NI 64 NIGrGGIO193 (GOOSE Validity Groups) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 $ST$Ind7 $ST$Ind8 $ST$Ind9 $ST$Ind10 $ST$Ind11 $ST$Ind12 $ST$Ind13 $ST$Ind14 $ST$Ind15 $ST$Ind16 329. [Application note] Description Single point status for GOOSE Validity Group 1 Single point status for GOOSE Validity Group 2 Single point status for GOOSE Validity Group 3 Single point status for GOOSE Validity Group 4 Single point status for GOOSE Validity Group 5 Single point status for GOOSE Validity Group 6 Single point status for GOOSE Validity Group 7 Single point status for GOOSE Validity Group 8 Single point status for GOOSE Validity Group 9 Single point status for GOOSE Validity Group 10 Single point status for GOOSE Validity Group 11 Single point status for GOOSE Validity Group 12 Single point status for GOOSE Validity Group 13 Single point status for GOOSE Validity Group 14 Single point status for GOOSE Validity Group 15 Single point status for GOOSE Validity Group 16 GPubGGIO194 (GOOSE Publisher properties) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 ANGEN.EN016 Description Single point status for GCB1 Test Single point status for GCB1 Needs Commissioning Single point status for GCB2 Test Single point status for GCB2 Needs Commissioning 62 [Application note] 330. FTrpGGIO195 (Final TRIP for Objects) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 $ST$Ind6 331. Description Measured value for Impedance Measured value for Angle Measured value for Distance in km EFRFLO2 (Distance to Earth Fault) Data Object $MX$FltZ$cVal$mag$f $MX$FltZ$cVal$ang$f $MX$FltDiskm$mag$f 63 Description Measured value for Temperature of PT100 SI Unit for Temperature of PT100 (°C) Unit multiplier value for Temperature of PT100 SCRFLO1 (Incomer SC Fault Locator) Data Object $MX$FltZ$cVal$mag$f $MX$FltZ$cVal$ang$f $MX$FltDiskm$mag$f 334. Description Single point status for Record Made Integer status for Fault Number Integer status for Memory Used in % Controllable single point status for Trigger Recorder TmpGGIO196 (Temperature PT100) Data Object $MX$AnIn $CF$AnIn$units$SIUnit $CF$AnIn$units$multiplier 333. Description Single point status for Object 1 Final Trip Single point status for Object 2 Final Trip Single point status for Object 3 Final Trip Single point status for Object 4 Final Trip Single point status for Object 5 Final Trip Single point status for Object 6 Final Trip DrRDRE1 (Disturbance recorder) Data Object $ST$RcdMade $ST$FltNum $ST$MemUsed $CO$RcdTrg 332. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Measured value for Impedance Measured value for Angle Measured value for Distance in km ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 335. VAIGGIO197 (GOOSE Virtual AI) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $MX$AnIn4 $MX$AnIn5 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn4$units$SIUnit $CF$AnIn5$units$SIUnit $CF$AnIn1$units$multiplier $CF$AnIn2$units$multiplier $CF$AnIn3$units$multiplier $CF$AnIn4$units$multiplier $CF$AnIn5$units$multiplier 336. Description Measured value for Current for Incomer SC before fault Measured value for Current for Incomer SC during fault Measured value for Current for Incomer SC after fault SI Unit for Current for Incomer SC before fault SI Unit for Current for Incomer SC during fault SI Unit for Current for Incomer SC after fault Unit multiplier value for Current for Incomer SC before fault Unit multiplier value for Current for Incomer SC during fault Unit multiplier value for Current for Incomer SC after fault DFLTGGIO199 (Fault distance indication) Data Object $ST$Ind 338. Description Measured value for GOOSE Analog Input 1 Measured value for GOOSE Analog Input 2 Measured value for GOOSE Analog Input 3 Measured value for GOOSE Analog Input 4 Measured value for GOOSE Analog Input 5 SI Unit for GOOSE Analog Input 1 SI Unit for GOOSE Analog Input 2 SI Unit for GOOSE Analog Input 3 SI Unit for GOOSE Analog Input 4 SI Unit for GOOSE Analog Input 5 Unit multiplier value for GOOSE Analog Input 1 Unit multiplier value for GOOSE Analog Input 2 Unit multiplier value for GOOSE Analog Input 3 Unit multiplier value for GOOSE Analog Input 4 Unit multiplier value for GOOSE Analog Input 5 SCIGGIO198 (Current for Incomer SC) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn1$units$multiplier $CF$AnIn2$units$multiplier $CF$AnIn3$units$multiplier 337. [Application note] Description Single point status for Fault Distance Indication FLRFLO3 (Feeder Fault Locator) Data Object $MX$FltZ$cVal$mag$f $MX$FltZ$cVal$ang$f $MX$FltDiskm$mag$f ANGEN.EN016 Description Measured value for Impedance Measured value for Angle Measured value for Distance in km 64 [Application note] 339. LED2GGIO200 (LEDs for 2xx and 5x series) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 $ST$Ind4 $ST$Ind5 340. Description Controllable single point status for Remote Reset Stat1GGIO1 (OC Stages Ena/Grp Info) Data Object $ST$IntIn1 $ST$IntIn2 $ST$IntIn3 $ST$IntIn4 $ST$IntIn5 $ST$IntIn6 $ST$IntIn7 $ST$IntIn8 65 Description Single point status for LED F (5x Series) Single point status for LED G (5x Series) Single point status for LED H (5x Series) ResGGIO202 (Remote Reset) Data Object $CO$SPCSO 342. Description Single point status for Alarm LED (2xx Series) / LED A (5x Series) Single point status for Trip LED (2xx Series) / LED B (5x Series) Single point status for LED A (2xx Series) / LED C (5x Series) Single point status for LED B (2xx Series) / LED D (5x Series) Single point status for LED C (2xx Series) / LED E (5x Series) LED5GGIO201 (LEDs for 5x series) Data Object $ST$Ind1 $ST$Ind2 $ST$Ind3 341. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Integer status for Overcurrent Protection Stage 1 (enabled/disabled/blocked) Integer status for Setting Group of Overcurrent Protection Stage 1 Integer status for Overcurrent Protection Stage 2 (enabled/disabled/blocked) Integer status for Setting Group of Overcurrent Protection Stage 2 Integer status for Overcurrent Protection Stage 3 (enabled/disabled/blocked) Integer status for Setting Group of Overcurrent Protection Stage 3 Integer status for Current Unbalance Protection Stage 1 (enabled/disabled/blocked) Integer status for Setting Group of Current Unbalance Protection Stage 1 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 343. Stat2GGIO1 (EF Stages Ena/Grp Info) Data Object $ST$IntIn1 $ST$IntIn2 $ST$IntIn3 $ST$IntIn4 $ST$IntIn5 $ST$IntIn6 $ST$IntIn7 $ST$IntIn8 344. Description Integer status for Earth-fault Protection Stage 1 (enabled/disabled/blocked) Integer status for Setting Group of Earth-fault Protection Stage 1 Integer status for Earth-fault Protection Stage 2 (enabled/disabled/blocked) Integer status for Setting Group of Earth-fault Protection Stage 2 Integer status for Earth-fault Protection Stage 3 (enabled/disabled/blocked) Integer status for Setting Group of Earth-fault Protection Stage 3 Integer status for Earth-fault Protection Stage 4 (enabled/disabled/blocked) Integer status for Setting Group of Earth-fault Protection Stage 4 Stat3GGIO1 (OCb Stages Ena/Grp Info) Data Object $ST$IntIn1 $ST$IntIn2 $ST$IntIn3 $ST$IntIn4 $ST$IntIn5 $ST$IntIn6 345. [Application note] Description Integer status for Overcurrent Protection Stage 1 for Secondary Side (enabled/disabled/blocked) Integer status for Setting Group of Overcurrent Protection Stage 1 for Secondary Side Integer status for Overcurrent Protection Stage 2 for Secondary Side (enabled/disabled/blocked) Integer status for Setting Group of Overcurrent Protection Stage 2 for Secondary Side Integer status for Current Unbalance Protection Stage for Secondary Side (enabled/disabled/blocked) Integer status for Setting Group of Current Unbalance Protection Stage for Secondary Side IFLTGGIO1 (Fault currents) Data Object $MX$AnIn1 $MX$AnIn2 $MX$AnIn3 $MX$AnIn4 $MX$AnIn5 $MX$AnIn6 $CF$AnIn1$units$SIUnit $CF$AnIn2$units$SIUnit $CF$AnIn3$units$SIUnit $CF$AnIn4$units$SIUnit $CF$AnIn5$units$SIUnit $CF$AnIn6$units$SIUnit ANGEN.EN016 Description Measured value for IL1 Fault Current Measured value for IL2 Fault Current Measured value for IL3 Fault Current Measured value for Io1 Fault Current Measured value for Io2 Fault Current Measured value for Io Calculated Fault Current SI Unit for IL1 Fault Current (A) SI Unit for IL2 Fault Current (A) SI Unit for IL3 Fault Current (A) SI Unit for Io1 Fault Current (A) SI Unit for Io2 Fault Current (A) SI Unit for Io Calculated Fault Current (A) 66 [Application note] 346. OCPTRC1 (OC trip) Data Object $ST$Tr$general $ST$Tr$phsA $ST$Tr$phsB $ST$Tr$phsC $ST$Str$general $ST$Str$phsA $ST$Str$phsB $ST$Str$phsC 347. Description Single point status for Trip Signal of any Overcurrent Protection Stage Single point status for Trip Signal of any Overcurrent Protection Stage in Phase 1 Single point status for Trip Signal of any Overcurrent Protection Stage in Phase 2 Single point status for Trip Signal of any Overcurrent Protection Stage in Phase 3 Single point status for Start Signal of any Overcurrent Protection Stage Single point status for Start Signal of any Overcurrent Protection Stage in Phase 1 Single point status for Start Signal of any Overcurrent Protection Stage in Phase 2 Single point status for Start Signal of any Overcurrent Protection Stage in Phase 3 CBAlmGGIO1 (CB Inactivity alarms) Data Object $ST$Alm1 $ST$Alm2 $ST$Alm3 $ST$Alm4 $ST$Alm5 $ST$Alm6 67 Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Inactivity Alarm of Object 1 Single point status for Inactivity Alarm of Object 2 Single point status for Inactivity Alarm of Object 3 Single point status for Inactivity Alarm of Object 4 Single point status for Inactivity Alarm of Object 5 Single point status for Inactivity Alarm of Object 6 ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units 348. EFPTRC2 (EF trip) Data Object $ST$Tr$general $ST$Tr$phsA $ST$Tr$phsB $ST$Tr$phsC $ST$Tr$neut $ST$Str$general $ST$Str$phsA $ST$Str$phsB $ST$Str$phsC $ST$Str$neut 349. Description Set point of type integer for CT Primary SI Unit for CT Primary (A) Set point of type integer for CT Secondary SI Unit for CT Secondary (A) CTIoGGIO1 (CT Io1 parameters) Data Object $SP$Primary $CF$Primary$units$SIUnit $SP$Secondary $CF$Secondary$units$SIUnit 352. Description Single point status for Disturbance Recording Deleted Single point status for Disturbance Recording Overwritten CTGGIO1 (CT parameters) Data Object $SP$Primary $CF$Primary$units$SIUnit $SP$Secondary $CF$Secondary$units$SIUnit 351. Description Single point status for Trip Signal of any Earth-fault Protection Stage Single point status for Trip Signal of any Earth-fault Protection Stage in Phase 1 Single point status for Trip Signal of any Earth-fault Protection Stage in Phase 2 Single point status for Trip Signal of any Earth-fault Protection Stage in Phase 3 Single point status for Trip Signal of any Earth-fault Protection Stage Neutral Phase Single point status for Start Signal of any Earth-fault Protection Stage Single point status for Start Signal of any Earth-fault Protection Stage in Phase 1 Single point status for Start Signal of any Earth-fault Protection Stage in Phase 2 Single point status for Start Signal of any Earth-fault Protection Stage in Phase 2 Single point status for Start Signal of any Earth-fault Protection Stage Neutral Phase DrGGIO1 (Disturbance recorder) Data Object $ST$Ind1 $ST$Ind2 350. [Application note] Description Set point of type integer for Io1 CT Primary SI Unit for CT Io1 Primary (A) Set point of type integer for Io1 CT Secondary SI Unit for CT Io1 Secondary (A) SG3GGIO135 (Setting group 3) Data Object $CO$SPCSO $ST$SPCSO ANGEN.EN016 Description Controllable single point status for Setting Group 3 Single point status for Setting Group 3 active 68 [Application note] 353. SG4GGIO136 (Setting group 4) Data Object $CO$SPCSO $ST$SPCSO 354. Description Single point status for Ethernet Port 2 link down ALLPTRC1 (Global trip) Data Object $Op$general 69 Description Single point status for Ethernet Port 1 link down Lnk2DnGGIO2 (Link 2 down) Data Object $ST$Ind 356. Description Controllable single point status for Setting Group 4 Single point status for Setting Group 4 active Lnk1DnGGIO1 (Link 1 down) Data Object $ST$Ind 355. Global Logical Node List for VAMP Protection Relays and Arc Protection Units Description Single point status for Global Trip ANGEN.EN016 Global Logical Node List for VAMP Protection Relays and Arc Protection Units [Application note] Appendix 1 - LLN0 and LPHD in Data Sets In the IEC 61850 main config menu in Vampset, there is an option to add LLN0 and LPHD to Data Sets 1, 2 and 3: After this option has been set, the following relevant information will be available into the Data Sets: LLN0$ST$Loc$stVal Single Point Status information for Local / Remote state of the IED VampLPHD1$ST$PhyHealth Single Point Status information for Self Diagnosis of the IED ANGEN.EN016 70
© Copyright 2026 Paperzz